• Title/Summary/Keyword: quality variation

Search Result 2,652, Processing Time 0.034 seconds

Characteristics of Indoor Air Quality and Local Supply Index with a Variation of Supply ${\cdot}$ Exhaust Airflow rate (환기량 변화에 따른 실내공기질과 국소급기지수 특성)

  • Han, Chang-Woo;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.21-26
    • /
    • 2005
  • We performed the numerical analysis on the characteristics of indoor air quality and local supply index with a variation of supply · exhaust airflow rate. We analyzed the local supply index and carbon dioxide concentration at the room and breathing zone with respect to the variation of the supply · exhaust airflow rate. From the numerical results, we found that local supply index was affected but carbon dioxide concentration was hardly affected by the variation of the airflow rate in the room. And we also knew that carbon dioxide concentration was raised in despite of the increment of the supply airflow rate in the breathing zone. After this study it is necessary to analyze the local exhaust index when we evaluate the state of the ventilation in the room.

  • PDF

Objectively Predicting Ultimate Quality of Post-Rigor Pork Musculature: I. Initial Comparison of Techniques

  • Joo, S.T.;Kauffman, R.G.;Warner, R.D.;Borggaard, C.;Stevenson-Barry, J.M.;Lee, S.;Park, G.B.;Kim, B.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.1
    • /
    • pp.68-76
    • /
    • 2000
  • A total of 290 pork loins were selected to include a wide variation of quality to investigate the quality categories into which most pork falls, selection criteria for these categories and methods to objectively assess ultimate pork quality. They were probed at 24 h postmortem (PM) for the following: A) light reflectance by Danish Meat Quality Marbling (MQM), Hennessy Grading Probe (HGP) and Sensoptic Invasive Probe (SIP); B) electrical properties by NWK LT-K21 conductivity (NLT) and Sensoptic Resistance Probe (SRP): and C) pH by NWK pH-K21 (NpH). Also, measurements of % drip loss (PDL) and filter paper wetness (FPW), color brightness (L*), ultimate pH (pHu), lipid content, subjective color (SC), firmness/wetness (SF) and marbling scores (SM) were assessed. Each loin was categorized as either pale, soft and exudative (PSE), reddish-pink, soft and exudative (RSE), reddish-pink, firm and non-exudative (RFN) or dark, firm and dry (DFD). Statistically comparing coefficients of determination (CD), the results indicated that overall, the HGP predicted quality groups slightly better than MQM (CD=71 and 62% respectively), NpH and SRP were less effective (CD= 56 and 44% respectively), and SIP and NLT had the lowest values (CD=36 and 5% respectively). Combining various independent variable did not greatly improve the variation accounted for. When the data was sorted into marbling groups based on lipid content, this was not accurately predicted by any of the probe measurements. The MQM probe remained the best predictor for marbling class and accounted for about 25% of the lipid content variation. This was slightly improved to 33% when pHu was combined with MQM.

Temporal Variation of Indoor Air Quality in Daycare Centers (어린이집에서 이산화탄소와 미세먼지의 장기간 시간적인 변이를 활용한 실내환경수준 평가)

  • Kim, Yoonjee;Lee, Sewon;Ban, Hyunkyung;Cha, Sangmin;Kim, Geunbae;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.267-272
    • /
    • 2017
  • Objectives: The purposes of the study were to analyze the temporal variation of carbon dioxide ($CO_2$) and particulate matter (PM) in daycare centers and evaluate the appropriateness of the official test method of one-time measurement. Methods: Indoor air quality in 46 daycare centers in the Seoul Metropolitan Area was measured as specified in the official test method of Indoor Air Quality Management law. In addition, indoor air quality in the 46 daycare centers was measured over 37 days using a real-time monitor (AirGuard K). Results: The daily means of $CO_2$ and PM in the 46 daycare centers were $1042.74{\pm}134.45ppm$ and $67.60{\pm}18.25{\mu}g/m^3$, respectively. Indoor air quality in the daycare centers showed significant temporal fluctuation. Measurements for single days were significantly different from the 37-day average exposure. Relative error of short term exposure decreased with an increase in the number of sampling days. The noncompliance rate for $CO_2$ using the official testing method was 2.17%, and none exceeded the $PM_{10}$ standard of $100{\mu}g/m^3$. With monitoring over 37 days, the daily noncompliance rate for $CO_2$ was 50.4% and the daily noncompliance rate for PM was 13.8%. Conclusions: When the official test method evaluates the indoor air at daycare centers one day per year, the results may not represent actual indoor air quality over a longer period of time. Real-time monitoring devices could be an alternative for managing indoor air quality.

The Evaluation of Water Quality in Coastal Sea of Incheon Using a Multivariate Analysis (다변량 해석기법을 이용한 인천연안해역의 수질평가)

  • Kim, Jong-Gu
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1017-1025
    • /
    • 2006
  • This study was conducted to evaluate characteristic of water duality in coastal sea of Incheon using a multivariate analysis. The analysis data in coastal sea of Incheon was aquired by the NFRDI data which was surveyed from March 1997 to November 2003. Eleven water quality parameters were determined on each survey The results were summarized as follow : Water quality in Incheon coastal sea could be explained up to 64.62% by three factors which were included in loading of fresh water and nutrients by the land(36.98%), seasonal variation(16.19%), and internal metabolism (11.24%). The results of time series analysis by factor score, in case of factor 1, station 1 influenced by Han river was shown to high factor score and station 3 located by outer sea was shown to low factor score. In case of factor 2, station 1 was appeared to high variation and station 3 was appeared to low variation. The result of cluster analysis by station was classified into three group that has different water quality characteristics. Especially, station 1 which affected by Han river and station 4 which affected by sewage treatment plant was appeared to considerable water quality characteristics against other station. In yearly cluster analysis, three group was classified and water quality in 2003 years due to high precipitation was different to another year. It could be suggested from these results that it is important to control discharge of fresh water by Han rivet and sewage treatment plant for water quality management of coastal sea of Incheon.

Alternative Methods for Simultaneous Optimization of Multi-Responses in Parameter Design (파라미터 설계에 대한 다중 반응 동시 최적화 대체 방안)

  • Park Byung-Jun;Cho Byung-Yup;Kwon Yong-Man
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.123-132
    • /
    • 1998
  • Robust design is an approach to reducing performance variation of quality characteristic values in quality engineering. Taguchi has an idea that mean and variation are handled simultaneously to reduce the expected loss in products. Taguchi parameter design has a great deal of advantages but it also has some disadvantages. The various research efforts aimed at developing alternative methods.

  • PDF

A Study on the Properties of High Flowing Concrete with Quality Variation of Crushed Sand (부순모래의 품질변화에 따른 고유공콘크리트의 특성에 관한 연구)

  • Choi, Il-Ho;Jung, Yang-Hee;Yum, Jun-Hwan;Choi, Jin-Man;Lee, Seong-Yeon;Hong, Kuung-Seon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.81-84
    • /
    • 2006
  • Currently, natural aggregates of good quality are hard to use because of continuous decrease of internal aggregate resource and regulation of gathering. So, use of crushed sand was being increased. On the other hand, skyscraper projects with 100 stories are being planned within the country and high strength concrete must be used to construct a skyscraper with 100 stories. High strength concrete is necessary to use crushed sand too because we are still unable to secure natural aggregates of good quality. So, This study indicated basic data necessary for mix design of high strength concrete through valuation of concrete property by quality variation of crushed sand.

  • PDF

Comparative assessment of surface and ground water quality using geoinformatics

  • Giridhar, M.V.S.S.;Mohan, Shyama;Kumar, D. Ajay
    • Advances in environmental research
    • /
    • v.9 no.3
    • /
    • pp.151-160
    • /
    • 2020
  • Water quality demonstrates physical, chemical and biological characteristics of water. The quality of surface and groundwater is currently an important concern with population growth and industrialization. Over exploitation of water resources due to demand is causing the deterioration of surface water and ground water. Periodic water quality testing must be carried out to protect our water resources. The present research analyses the spatial variation of surface water and groundwater in and around the lakes of Hyderabad. Twenty-Seven lakes and their neighboring bore water samples are obtained for water quality monitoring. Samples are evaluated for specific physico-chemical parameters such as pH, Total Dissolved Solids (TDS), Cl, SO4, Na, K, Ca, Mg, and Total Hardness (TH). The spatial variation of water quality parameters for the 27 lakes and groundwater were analysed. Correlation and multiple regression analysis were carried out to determine comparative study of lake and ground water. The study found that most of the lakes were polluted and this had an impact on surrounding ground water.

An Objective No-Reference Perceptual Quality Assessment Metric based on Temporal Complexity and Disparity for Stereoscopic Video

  • Ha, Kwangsung;Bae, Sung-Ho;Kim, Munchurl
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.5
    • /
    • pp.255-265
    • /
    • 2013
  • 3DTV is expected to be a promising next-generation broadcasting service. On the other hand, the visual discomfort/fatigue problems caused by viewing 3D videos have become an important issue. This paper proposes a perceptual quality assessment metric for a stereoscopic video (SV-PQAM). To model the SV-PQAM, this paper presents the following features: temporal variance, disparity variation in intra-frames, disparity variation in inter-frames and disparity distribution of frame boundary areas, which affect the human perception of depth and visual discomfort for stereoscopic views. The four features were combined into the SV-PQAM, which then becomes a no-reference stereoscopic video quality perception model, as an objective quality assessment metric. The proposed SV-PQAM does not require a depth map but instead uses the disparity information by a simple estimation. The model parameters were estimated based on linear regression from the mean score opinion values obtained from the subjective perception quality assessments. The experimental results showed that the proposed SV-PQAM exhibits high consistency with subjective perception quality assessment results in terms of the Pearson correlation coefficient value of 0.808, and the prediction performance exhibited good consistency with a zero outlier ratio value.

  • PDF

An Adaptive Binarization of Camera Document Image by Image Quality Estimation (화질 분석을 통한 카메라 문서 영상의 적응적 이진화)

  • Kim, In-Jung
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.9
    • /
    • pp.797-803
    • /
    • 2007
  • Adaptive binarization is very important for the camera-based document recognition. This paper proposes a binarization method which can effectively adapt to the variation of image Qualify. Firstly, it analyzes the effect of binarization parameters to the result and proposes a method to measure the image quality. Then, it statistically analyzes the relationship between the image quality and the binarization parameter. Finally, it proposes a binarization method that automatically adapts to the quality of the input image, using the analysis result. The experiment results show that there is a meaningful relationship between the image quality and the binarization parameter, and therefore, the proposed method can effectively adapt to the variation of image quality.

Prediction of Water Quality Variation Caused by Dredging Urban River-bed (도시하천의 하상퇴적토 준설에 따른 수질변화 예측)

  • Jo, Hong-Je;Lee, Byeong-Ho;Kim, Jeong-Sik;Lee, Geun-Bae
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.137-148
    • /
    • 2002
  • The purpose of this study was to examine the effect of water quality improvement due to dredging the bottom deposit at the downstream of a urban river. The finite difference method was used to analyze the water quality variations caused by the depths of dredging and intercepting ratios of the goal years. 21 boring points were selected along the 11.2km river reach running through a metropolitan city. The pollution levels of the deposits from the bored Points were examined by the leaching test. The improvement effect of the water quality, measured as changes of COD, were carried at under drought, minimal, and normal flow. The result indicates that the dredging of the contaminated sludge contributes the improvement of the water quality.