• Title/Summary/Keyword: quality evaluation prototype

Search Result 71, Processing Time 0.025 seconds

Site Quality Evaluation Prototype for Building Deck-plate Construction

  • Shim, Young-Bo;Cho, Dong-Hyun;Koo, Kyo-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.1
    • /
    • pp.90-100
    • /
    • 2013
  • Deck-plates are widely used on construction sites, and have the advantage of enabling contractors to achieve a relatively uniform quality. But nevertheless, quality deviation in deck-plate construction can occur as the result of differences in site conditions and the experience of crew workers. In this study, the authors present a site quality evaluation prototype for building deck-plate construction. Through analyses of case studies and interviews with experts, standard quality check sheets and a quality management index were developed by estimating the importance of quality check items based on a Failure Mode and Effects Analysis (FMEA) method. The applicability and effectiveness of the prototype was evaluated through a case study and interviews with case participants. It was found that the prototype promoted an active quality management as a way of continuously improving quality management in deck-plate construction instead of passive quality inspection practice.

Development of Rotating Cone Type Garlic Clove Separator (III) - Design and Performance Evaluation of Final Protype - (회전 원추형 마늘 쪽분리기 개발에 관한 연구 (III) - 최종기 설계 및 성능평가 -)

  • Lee, J.S.;Kim, K.B.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.2 s.121
    • /
    • pp.84-90
    • /
    • 2007
  • This study was conducted to design and manufacture a final prototype of garlic separator and to evaluate its performance. The performance of garlic separation was compared with manual separation. The final prototype for garlic separation consists of bucked-elevator device for automatic feed of garlic, rotating cone typed device, blower, and power transmission device. The optimal condition of outlet clearance was 19 mm and in this clearance, the proportions of fragment garlic separated in the large quality of Namdo garlic and all quality of Uiseong garlic were above 95% and above 85%, respectively. All proportion of damaged garlic was below 5% for all variety and quality. The garlic separation capacities of this developed machine were 310 kg/h for Namdo garlic and 293.6 kg/h for Uiseong garlic in the large quality. Capacities of final prototype compared with human being were $12.9{\sim}19.6$ times for Namdo and $24.2{\sim}31.7$ times Uiseong garlic, respectively.

Design and Implementation of LGPFID System (수산시책 평가시스템 설계 및 구현)

  • 어윤양;황현숙;김갑수
    • The Journal of Fisheries Business Administration
    • /
    • v.32 no.1
    • /
    • pp.81-97
    • /
    • 2001
  • The main objective of this research is to identify the evaluation criteria of the local governments' projects for the fisheries industry development (LGPFID) and to develop the evaluation software prototype applicable to LGPFID. This research does not try to develop the whole evaluation processes and programs for LGPFID, but just to outline the approach to managing LGPFID. The evaluation processes and programs developed in this study is based on the group decision support systems(GDSS), which is a collaborative, system-oriented, and objective system useful in evaluating LGPFID. Specifically the goals of the programs are to : (1) enhance the quality of evaluation process for LGPFID; (2) provide the local government decision makers' and interest groups' access to comprehensive evaluation information; (3) support private-public collaboration in government's decision making. We used analytic hierarchy process model as a group decision making model and programmed the application software prototype with Visual Basic language.

  • PDF

Development of Nondestructive Evaluation System for Internal Quality of Watermelon using Acoustic Wave (음파를 이용한 비파괴 수박 내부품질 판정 시스템 개발)

  • Choi, Dong-Soo;Lee, Young-Hee;Choi, Seung-Ryul;Kim, Gi-Young;Park, Jong-Min
    • Food Science and Preservation
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Watermelons (Citrulus vulgaris Schrad) are usually sorted manually by weight, appearance, and acoustic impulse, so grading of maturity and internal quality is subject to inaccuracies. It was necessary to develop a nondestructive evaluation technique of internal watermelon quality to reduce human error. Thus, acoustic characteristics related to internal quality factors were analyzed. Among these factors, three (ripeness, presence of an internal cavity, and blood-colored flesh) were selected for evaluation. The number of peaks and the sum of peak amplitudes for watermelons with blood-colored flesh were lower than for normal fruits. The portable evaluation system has an impact mechanism, a microphone sensor, a signal processing board, an LCD panel, and a battery. A performance test was conducted in the field. The internal quality evaluation model showed 87% prediction accuracy. Validation was conducted on 72 samples. The accuracy of quality evaluation was 83%. The quality of samples was evaluated by an inspector using conventional methods (hitting the watermelon and listening to the sounds), and then compared with prototype results. The quality evaluation accuracy of the prototype was better than that of the inspector. This nondestructive quality evaluation system could be useful in the field, warehouse, and supermarket

Crosstalk evaluation in multiview autostereoscopic three-dimensional displays with an optimized diaphragm applied

  • Peng, Yi-Fan;Li, Hai-Feng;Zheng, Zhen-Rong;Xia, Xin-Xing;Yao, Zhi;Liu, Xu
    • Journal of Information Display
    • /
    • v.13 no.2
    • /
    • pp.83-89
    • /
    • 2012
  • The crosstalk evaluation of multiview autostereoscopic three-dimensional (3D) displays is discussed, with both the human and technical factors investigated via image quality assessment. In the imaging performance measurements and analysis for a multiview autostereoscopic display prototype equipment, it was inferred that crosstalk would have both a positive and a negative effect on the imaging performance of the equipment. The importance of the attached diaphragm in the crosstalk evaluation was proposed and then experimentally verified, using the developed prototype equipment. The luminance distribution and crosstalk situation were given, with two different diaphragm arrays applied. The analysis results showed that the imaging performance of this 3D display system can be improved with minimum changes to the system structure.

Application of the Rapid Prototyping Instructional Systems Design in Meridianology Laboratory (경혈학실습 체제적 교수설계를 위한 RPISD 모형 적용 연구)

  • Cho, Eunbyul;Kim, Jae-Hyo;Hong, Jiseong
    • Korean Journal of Acupuncture
    • /
    • v.39 no.3
    • /
    • pp.71-83
    • /
    • 2022
  • Objectives : Instructional design is the systematic approach to the Analysis, Design, Development, Implementation, and Evaluation of learning materials and activities. We aimed to apply the rapid prototyping to instructional systems design (RPISD) in meridianology laboratory, a subject in which students train acupuncture to develop lesson plan. Methods : The needs of the stakeholders including client, subject matter expert and students were analyzed using the performance needs analysis model. Task analysis was implemented by observation and interview. First prototype was drafted and implemented in meridianology laboratory class once. The second prototype was modified from the first, by usability evaluation of the stakeholders. Results : The client requested an electronically documented manual to improve the quality of acupuncture training. The learner requested an extension of practice time and detailed practice guidelines. The main problems of students' performance were some cases of violation of clean needle technique, the lack of communication between the operator and recipient in direct, and lack of confidence in their own performance. Stakeholders were generally satisfied with the proposed first prototype. Second prototype of lesson plan was produced by modifying some contents. Conclusions : A lesson plan was developed by applying the systematic RPISD model. It is expected that the developed instructional design may contribute to the quality improvement of meridianology laboratory education.

Development of On-line Quality Sorting System for Dried Oak Mushroom - 3rd Prototype-

  • 김철수;김기동;조기현;이정택;김진현
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.1
    • /
    • pp.8-15
    • /
    • 2003
  • In Korea, quality evaluation of dried oak mushrooms are done first by classifying them into more than 10 different categories based on the state of opening of the cap, surface pattern, and colors. And mushrooms of each category are further classified into 3 or 4 groups based on its shape and size, resulting into total 30 to 40 different grades. Quality evaluation and sorting based on the external visual features are usually done manually. Since visual features of mushroom affecting quality grades are distributed over the entire surface of the mushroom, both front (cap) and back (stem and gill) surfaces should be inspected thoroughly. In fact, it is almost impossible for human to inspect every mushroom, especially when they are fed continuously via conveyor. In this paper, considering real time on-line system implementation, image processing algorithms utilizing artificial neural network have been developed for the quality grading of a mushroom. The neural network based image processing utilized the raw gray value image of fed mushrooms captured by the camera without any complex image processing such as feature enhancement and extraction to identify the feeding state and to grade the quality of a mushroom. Developed algorithms were implemented to the prototype on-line grading and sorting system. The prototype was developed to simplify the system requirement and the overall mechanism. The system was composed of automatic devices for mushroom feeding and handling, a set of computer vision system with lighting chamber, one chip microprocessor based controller, and pneumatic actuators. The proposed grading scheme was tested using the prototype. Network training for the feeding state recognition and grading was done using static images. 200 samples (20 grade levels and 10 per each grade) were used for training. 300 samples (20 grade levels and 15 per each grade) were used to validate the trained network. By changing orientation of each sample, 600 data sets were made for the test and the trained network showed around 91 % of the grading accuracy. Though image processing itself required approximately less than 0.3 second depending on a mushroom, because of the actuating device and control response, average 0.6 to 0.7 second was required for grading and sorting of a mushroom resulting into the processing capability of 5,000/hr to 6,000/hr.

  • PDF

A Study on Quality Improvement and Advancement of Negative Pressure Isolation Stretcher: Using FOCUS-PDCA (음압격리들것의 품질개선과 고도화 연구: FOCUS-PDCA 모형을 활용하여)

  • Choi, Hyunchul;Seo, Seul-Ki;Byun, Sungkwan;Chang, Hyejung;Park, Sangchan
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.4
    • /
    • pp.715-734
    • /
    • 2023
  • Purpose: Authors suggest a new alternative of preparedness capabilities for health care institutes to react to the new types of communicable diseases and the pandemic situations through the quality improvement and advancement of Negative Pressure Isolation Stretcher (NPIS). Methods: We employed FOCUS-PDCA, a representative quality improvement model. First, we identified and materialized necessary components of existing NPIS to be improved. Second, we fabricated an advanced NPIS prototype. Third, we carried out a performance test by the accreditation institute and an empirical evaluation at the communicable diseases trauma center, to locate the improvement pain points of the prototype. Finally, we draw a conclusion on quality improvement points to be considered during the production stage. Results: The suggested, NPIS outperforms the existing one in terms of communicable disease controls, patient treatments and the safety during the patient transfer, and the ease of use. Additionally, the suggested NPIS turns out to be a proper alternative to satisfy the requirements of long range transfer of patients with communicable disease. Conclusion: Authors developed a quality improved, NPIS prototype. There are several points that still remain to be improved. Additionally, we expect that the concurrent use of the suggested NPIS with the existing one will fortify the preparedness capabilities on reacting to the communicable diseases.

Performance Evaluation of Domestic Prototype Dose Area Product Meter SFT-1 (국산 프로토타입 면적선량계 SFT-1의 성능평가)

  • Lee, Ho-Sun;Han, Seong-Gyu;Roh, Young-Hoon;Lim, Hyun-Jong;Kim, Jung-Min;Kim, Jong-Uk;Chae, Hyun-Sik;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.435-441
    • /
    • 2016
  • The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R&BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatability coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria.

Development of an All-in-one Attachment-based PHC Pile Head Cutting Robot Prototype (All-in-one 어태치먼트 기반 PHC 파일 원커팅 두부정리 자동화 로봇의 프로토타입 개발)

  • Yeom, Dong-Jun;Park, Ye seul;Kim, Jun Sang;Kim, Young Suk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.2
    • /
    • pp.37-44
    • /
    • 2019
  • The primary objective of this study is to develop a prototype of all-in-one attachment-based PHC pile head cutting robot that improves the conventional work in safety, productivity, and quality. For this, the following research works are conducted sequentially; 1)literature review, 2)development of an all-in-one attachment-based PHC pile head cutting robot prototype, 3)performance evaluation of each device, 4)economic analysis of an automated method. As a result, PHC pile cutting level sensing device, PHC pile cutting device, PHC pile handling device are developed. Futhermore, working process of an automated method is developed based on result of performance evaluation. According to the economic analysis result, the cost of the automated method was 21.37% less than that of the conventional method, and the economic efficiency was also superior(ROR 215.44%, Break-even Point 5.52month). It is expected that conclusions for future improvements are used in the development of the all-in-one attachment-based PHC pile head cutting robot to practical use.