• Title/Summary/Keyword: quality deviation

Search Result 921, Processing Time 0.044 seconds

A Qualitative Study on Facilitating Factors of User-Created Contents: Based on Theories of Folklore (사용자 제작 콘텐츠의 활성화 요인에 대한 정성적 연구: 구비문학 이론을 중심으로)

  • Jung, Seung-Ki;Lee, Ki-Ho;Lee, In-Seong;Kim, Jin-Woo
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.43-72
    • /
    • 2009
  • Recently, user-created content (UCC) have emerged as popular medium of on-line participation among users. The Internet environment has been constantly evolving, attracting active participation and information sharing among common users. This tendency is a significant deviation from the earlier Internet use as an one-way information channel through which users passively received information or contents from contents providers. Thanks to UCCs online users can now more freely generate and exchange contents; therefore, identifying the critical factors that affect content-generating activities has increasingly become an important issue. This paper proposes a set of critical factors for stimulating contents generation and sharing activities by Internet users. These factors were derived from the theories of folklores such as tales and songs. Based on some shared traits of folklores and UCC content, we found four critical elements which should be heeded in constructing UCC contents, which are: context of culture, context of situation, skill of generator, and response of audience. In addition, we selected three major UCC websites: a specialized contents portal, a general internet portal, and an official contents service site, They have different use environments, user interfaces, and service policies, To identify critical factors for generating, sharing and transferring UCC, we traced user activities, interactions and flows of content in the three UCC websites. Moreover, we conducted extensive interviews with users and operators as well as policy makers in each site. Based on qualitative and quantitative analyses of the data, this research identifies nine critical factors that facilitate contents generation and sharing activities among users. In the context of culture, we suggest voluntary community norms, proactive use of copyrights, strong user relationships, and a fair monetary reward system as critical elements in facilitating the process of contents generation and sharing activities. Norms which were established by users themselves regulate user behavior and influence content format. Strong relationships of users stimulate content generation activities by enhancing collaborative content generation. Particularly, users generate contents through collaboration with others, based on their enhanced relationship and specialized skills. They send and receive contents by leaving messages on website or blogs, using instant messenger or SMS. It is an interesting and important phenomenon, because the quality of contents can be constantly improved and revised, depending on the specialized abilities of those engaged in a particular content. In this process, the reward system is an essential driving factor. Yet, monetary reward should be considered only after some fair criterion is established. In terms of the context of the situation, the quality of contents uploading system was proposed to have strong influence on the content generating activities. Among other influential factors on contents generation activities are generators' specialized skills and involvement of the users were proposed. In addition, the audience response, especially effective development of shared interests as well as feedback, was suggested to have significant influence on contents generation activities. Content generators usually reflect the shared interest of others. Shared interest is a distinct characteristic of UCC and observed in all the three websites, in which common interest is formed by the "threads" embedded with content. Through such threads of information and contents users discuss and share ideas while continuously extending and updating shared contents in the process. Evidently, UCC is a new paradigm representing the next generation of the Internet. In order to fully utilize this innovative paradigm, we need to understand how users take advantage of this medium in generating contents, and what affects their content generation activities. Based on these findings, UCC service providers should design their websites as common playground where users freely interact and share their common interests. As such this paper makes an important first step to gaining better understand about this new communication paradigm created by UCC.

Using Trophic State Index (TSI) Values to Draw Inferences Regarding Phytoplankton Limiting Factors and Seston Composition from Routine Water Quality Monitoring Data (영양상태지수 (trophic state index)를 이용한 수체 내 식물플랑크톤 제한요인 및 seston조성의 유추)

  • Havens, Karl E
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.3 s.91
    • /
    • pp.187-196
    • /
    • 2000
  • This paper describes a simple method that uses differences among Carlson's (1977) trophic state index (TSI) values based on total phosphorus (TP), chlorophyll a (CHL) and Secchi depth (SD) to draw inferences regarding the factors that are limiting to phytoplankton growth and the composition of lake seston. Examples are provided regarding seasonal and spatial patterns in a large subtropical lake (Lake Okeechobee, Florida, USA) and inter- and intra-lake variations from a multilake data set developed from published studies. Once an investigator has collected routine water quality data and established TSI values based on TP, CHL, and SD, a number of inferences can be made. Additional information can be provided where it also is possible to calculate a TSI based on total nitrogen (TN). Where TSI (CHL)<>TSI (SD), light attenuating particles are large (large filaments or colonies of algae), and the phytoplankton may be limited by zooplankton grazing. Other limiting conditions are inferred by different relationships between the TSI values. Results of this study indicate that the analysis is quite robust, and that it generally gives good agreement with conclusions based on more direct methods (e.g., nutrientaddition bioassays, zooplankton size data, zooplankton removal experiments). The TSI approach, when validated periodically with these more costly and time-intensive methods, provides an effective, low cost method for tracking long-term changes in pelagic structure and function with potential value in monitoring lake ecology and responses to management.

  • PDF

Community Structure of Benthic Macroinvertebrates and Water Quality in the Major Lakes (Lake Sayeon, Lake Daeam, Seonam Reservoir, Lake Hoeya) of Ulsansi (울산 지역 주요 호소(사연호, 대암호, 선암저수지, 회야호)의 수질 및 저서성대형무척추동물 군집구조 분석)

  • Lee, Mi-Jin;Kwon, Hyeok-Young;Lee, Hae-Jin;Seo, Jung-Kwan;Lee, Jae-Kwan;Lee, Jong-Eun
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.4
    • /
    • pp.396-406
    • /
    • 2011
  • To analyze between water quality and community structure of benthic macroinvertebrates, we selected four reservoirs (Lake Sayeon, Lake Daeam, Seonam reservoir and Lake Hoeya) in Ulsan-si and studied them from February 2010 to October 2010. The annual mean BOD (Biochemical Oxygen Demand) in the four lakes was $14.2mg\;L^{-1}$, and Seonam reservoir had the highest deviation in BOD. The maximum BOD for every lake was in February and their minimum in May, except for Lake Hoeya whose minimum was in July. The means of various nutrients were as follows: TN $0.051mg\;L^{-1}$, TP $0.100mg\;L^{-1}$, $NH_3-N\;0.606mg\;L^{-1}$, and $NO_3-N\;0.014mg\;L^{-1}$. The maximum TN was measured in June and the maximum and minimum TP were measured in March and in May respectively in the four lakes. Benthic macroinvertebrates were surveyed in April and October 2010. The number of benthic macroinvertebrates species was in the range of 16~36 and the average number of individuals were 58~208 inds. $m^{-2}$. Seonam reservoir, which has the highest mean TN ($0.082mg\;L^{-1}$) and $NO_3-N$($0.023mg\;L^{-1}$), had the largest number of species (36 species, 208 inds. $m^{-2}$). Pearson's correlation between the number of macro invertebrates species and TN was 0.962 (P<0.05), and between the species and $NO_3-N$ was 0.999 (P<0.05). These results show that the number of benthic macroinvertebrates species of the four lakes in Ulsan-si is significantly correlated with TN and $NO_3-N$.

Evaluation of confidence for measurement of VOCs in indoor air (실내공기질 VOCs 측정의 신뢰도 평가를 위한 연구)

  • Kim, Myoung Ock;Kim, Young Lan;Hong, Suk Young;Heo, Gwi Suk;Lim, Hyun Woo;Choe, Seoung Hun;Lee, Won Suk;Han, Jin Seok;Kim, Kum Hee
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • To establishment of PT Program for Indoor air quality field that manufacture of confidential development PTMs (proficiency testing materials) and examined of proficiency testing evaluation included sampling process whether or not that is valid. Confirmation of homogeneity and stability of PTMs prepared. PTMs were confirmed to be homogeneous enough to be used as proficiency testing materials since withinbottle homogeneities of the RMs were lower than 0.3 times of targeted standard deviation of proficiency testing. The result of this study showed that the Robust RSD of proficiency testing for VOCs (volatile organic compounds) appeared 23~43% in concentration of 50~320 ${\mu}g/m^3$ for Method A(Distribution by adsorption in Tenax-tube of VOCs), but less 13~42% in concentration of 200~1200 ${\mu}g/m^3$, 16~31% in concentration of 100~450 ${\mu}g/m^3$ for Method B (distribution by VOCs of gas phase in 10L Tedalr bag), C (directly sampling of cylinder with high pressure) respectively. The result of this study showed that method C with sampling is most adequate to the proficiency testing for VOCs in indoor air.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

Factors affecting the final adult height in survivors of childhood brain tumors (소아 뇌종양 환자의 최종 성인키에 영향을 미치는 인자)

  • Yun, Kyong-Ah;Lee, Young Ah;Shin, Choong Ho;Yang, Sei Won;Shin, Hee Young;Ahn, Hyo Seop;Kim, Il Han
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.1
    • /
    • pp.65-73
    • /
    • 2007
  • Purpose : Short stature is an important complication that impairs the quality of life in survivors of childhood brain tumors. We studied their final adult height (FAH) to evaluate risk factors for short stature. Methods : We reviewed the medical data of 95 survivors of childhood brain tumors (64 males and 31 females) who had been followed up from 1982 to 2006, reached FAH, and had a more than five year-disease-free survival. Results : Final adult height standard deviation score (FAHTSDS: $mean{\pm}SD$) of the patients was lower than those of general population ($-1.15{\pm}1.72$), HTSDS at diagnosis ($-0.13{\pm}1.57$), and target HTSDS ($-0.49{\pm}0.69$). FAHTSDS of craniopharyngioma patients did not decrease ($0.57{\pm}1.17$), but those of germ cell tumor and medulloblastoma patients were significantly reduced ($-1.20{\pm}1.45$, $-2.70{\pm}1.46$; P<0.05). The patients treated with craniospinal radiation or chemotherapy had lower FAHTSDS ($-1.93{\pm}1.58$, $-2.27{\pm}1.44$; P<0.01). In the spinal irradiation group, the younger the age at diagnosis was, the more the loss of FAH (r=0.442, P<0.01). Growth hormone replacement (GHR) didn't improve FAHTSDS, but starting GHR under 12 years was an independent factor for improving FAH once treatment methods were taken into account (P=0.01). Conclusion : The younger age at diagnosis, spinal radiation and chemotherapy were all important risk factors of height loss, and height gain was expected in patients who received GHR under the age of 12 years. Therefore, regular check-ups of growth and early intervention with growth hormones are needed for high risk groups to improve FAH.

Proficiency Testing for the HPLC Analysis of Azoxystrobin, Imidacloprid and Methabenzthiazuron Residues in Soil (HPLC를 이용한 아족시스트로빈과 이미다클로프리드, 메타벤즈티아주론의 토양 잔류분석 숙련도시험)

  • Kim, Chan-Sub;Son, Kyeong-Ae;Gil, Geun-Hwan;Im, Geon-Jae
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.218-229
    • /
    • 2015
  • The proficiency testing for the residue laboratories of pesticide registration was conducted in order to improve the reliability and the ability for pesticide residue analysis. On November 2012 the testing was carried out using the soil collected and kept as the moistened state for five years, which was expected to very low residue levels of pesticides. The soil was fortified with azoxystrobin, imidacloprid and methabenzthiazuron in a manner similar to prepare soil samples for indoor soil degradation test, and then sub-samples were prepared for the distribution to participants. Some of them were randomly selected for confirm of homogeneity and to ensure the stability of samples at room temperature. Samples were consisted of two soils treated as different levels, one of which was used to the assessment and another used to confirm. In addition, provided three standard solutions, respectively concentration of 10 mg/L, and untreated soil. Forty eight institutions submitted results. The medians of results were used as the assigned values for pesticide residues. Fitness for purpose standard deviation of proficiency test was calculated by applying 20% RSD as the coefficient of variation allowed in the soil residue test. Z-score was applied for evaluation of individual pesticides, and the average of the absolute value of the Z-score for the overall assessment of pesticides. Laboratories evaluated the absolute value of the Z-score less than 2 to fit the case of azoxystrobin were 48, imidacloprid and methabenzthiazuron 46.