• 제목/요약/키워드: quality assurance (QA)

검색결과 224건 처리시간 0.03초

ISO 9000 시리즈에 의한 품질보증(品質保證) 시스템이 우리 나라 기업경영(企業經營)에 미치는 영향(影響) (Study on the Effects of ISO 9000 Quality Assurance Systems in Korean Industry)

  • 임남진;김능진
    • 품질경영학회지
    • /
    • 제24권2호
    • /
    • pp.87-101
    • /
    • 1996
  • To investigate the impacts of ISO 9000 QA systems to the Korean industry quality improvement as well as quality consciousness, QA related data has been surveyed from quality assurance engineers who have worked on ISO 9000 certification activities and has been analyzed using relevant tabulations of five(5) scale or x2-homogeneity test method. Hypotheses to the unchange in the quality consciousness are tested in terms of x2-homogeneity in order to compare the consciousness of pre-certification with that of post-certification. The level of quality management of Korean manufacturing industry has been high-lighted by use of quality maturity grid.

  • PDF

세기조절방사선치료(IMRT) 환자의 QA (Quality Assurance of Patients for Intensity Modulated Radiation Therapy)

  • 윤상민;이병용;최은경;김종훈;안승도;이상욱
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.81-90
    • /
    • 2002
  • 목적 : 세기조절 방사선치료(IMRT) 환자에 적합한 Quality Assurance (QA) 항목을 찾아내고 평가 항목의 유용성 및 타당성을 검토하였다. 대상 및 방법 : 3단계, 16항목으로 구성된 IMRT 환자 QA program을 만들어 9환자 12예의 다양한 IMRT 환자에 대해 적용하고 그 방법의 타당성을 검토하였다. 3단계 OA 항목은 전산화치료계획시스템(RTP) QA, 치료 정보의 전달 QA, 치료 전달 과정 OA 등으로 구성되었다. RTP QA는 다시 organ constraint의 검토, 그리고 점선량 및 선량 분포의 타당성 평가 등으로 세분화하였다. 치료 정보의 전달 QA에서는 leaf sequence pattern 작성, 치료 전달용 MLC file 생성 프로그램에서 작성된 IMRT field 용 MLC file의 정확성의 평가와 이 file로 만든 치료 조사면의 dry run 결과를 MLC simulation image와 비교하였다. 치료 전달 과정 QA는 환자의 set-up QA와 IMRT field delivery의 확인, Record and Verify 시스템의 확인 등으로 나누어 실시하였다. 결과 : 점선량 평가 결과, 총 12예 중 10예에서 측정값과 RTP 계산값이 $3\%$ 이내의 일치를 보였고, $3\%$ 이상 및 $5\%$ 이상이 각각 1예씩 발견되었다. RTP에서 설계한 MLC leaf 위치와 Dry run에서 나타난 실제 MLC leaf 위치를 비교하였을 때 2 mm 이상의 차이를 보이는 예는 없었다. 필름에 의한 선량 분포는 치료 계획 선량 분포와 정성적으로 일치함을 알 수 있었으나, 필름의 특성상 정량적인 비교를 할 수는 없었다. Leaf sequence에서 MLC file을 생성하는 프로그램은 오차 없이 구동하였다. 결론 : 본원에서 실시한 IMRT 환자 QA program이 유용하고 필요한 항목임을 보일 수 있었다. 특히 처음 IMRT를 시작할 때는 제시된 모든 항목에 대한 QA를 실시하여야 하나 계속 이 program을 유지하기에는 절차가 복잡하고 긴 시간이 소요되는 과정이라는 문제가 있다. 지속적으로 IMRT를 실시하는 기관을 위해 실용적이며 필수적인 QA 항목을 제시할 수 있었다.

의료 질 관리 활동에 대한 병원종사자들의 태도와 인식 (Quality Improvement Activity in Hospitals and Its Acceptance among Hospital Personnels)

  • 황정해;조성현;김창엽;서정돈;한만청;이정예
    • 한국의료질향상학회지
    • /
    • 제3권2호
    • /
    • pp.86-97
    • /
    • 1997
  • Background : It is a primary goal for hospital personnel to improve the quality of patient care. In Korea the concept of quality assurance has been spread over the last five years. Many hospitals have implemented quality assurance programs that fit their own philosophy and needs. As a result, they are supposed to have different experiences and attitudes toward quality assurance. To investigate their diversity will be helpful to have a direction to the future and to enhance the quality assurance activities in Korean hospitals. Objectives : The aim of this study is to obtain information about hospital personnel's attitude and opinion toward quality assurance in hospitals. Methods : A questionnaire was developed which consisted of five parts; the general characteristics of respondent, the concepts of quality assurance, need for quality assurance program, current status of quality improvement activities, and participation in programs. Using the registry of Korean hospitals, 102 hospitals with more than 400 beds were selected. Questionnaires were mailed to hospital staffs of each hospital; top managers, clinical department heads, registered nurses, medical recorders, and administrators. Results : Of 2038 questionnaires sent, 877 were returned, giving response rate of 44%. Most respondents(70%) regarded quality assurance as efforts to provide patient with care in highest quality and to improve effectiveness or resource utilization. Ninety-nine percent of respondents agreed to need for quality assurance in their hospitals. There were current quality improvement programs implemented in the department of 553 respondents(62%), and most of the(85%) have participated in at least one program. Lack of motivation was pointed out as a barrier to implement the programs. Conclusion : Although most respondents have known of the concept and need for quality assurance, this study suggests that education and motivation of hospital personnel be needed to activate the quality assurance programs in hospitals.

  • PDF

Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy : a retrospective study

  • Oh, Se An;Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon
    • Journal of Yeungnam Medical Science
    • /
    • 제39권2호
    • /
    • pp.108-115
    • /
    • 2022
  • Background: This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device. Portal dosimetry is extensively used for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Methods: The study includes 29 patients who underwent IMRT on a Novalis-Tx linear accelerator (Varian Medical System and Brain-LAB) between June 2019 and March 2021. We analyzed the multileaf collimator DynaLog files generated after portal dosimetry to evaluate the same condition using FractionLab. The results of the recently launched FractionLab at various gamma indices (0.1%/0.1 mm-1%/1 mm) are analyzed and compared with those of portal dosimetry (3%/3 mm). Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and FractionLab are 98.1% (95.5%-100%) and 97.5% (92.3%-99.7%) at 0.6%/0.6 mm, respectively. The results of portal dosimetry (3%/3 mm) are statistically comparable with the QA results of FractionLab (0.6%/0.6 mm-0.9%/0.9 mm). Conclusion: This paper presents the clinical performance of FractionLab by the comparison of the QA results of FractionLab using portal dosimetry with various gamma indexes when performing patient-specific QA in IMRT treatment. Further, the appropriate gamma index when performing patient-specific QA with FractionLab is provided.

고선량율 근접치료의 정도관리 (Quality Assurance for High Dose Rate Brachytherapy)

  • 방동완;조정희;박재일
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.30-44
    • /
    • 1998
  • Accurate delivery of doses using a high dose rate(HDR) brachytherapy, remote afterloading system(RALS) depends on knowing the strength of the radioactive source at the time of treatment, the precision and consistency of the timer, and the ability of the unit to position the source at the proper dwell location along the applicator. Periodic Quality Assurance(QA) on HDR machines is a part of the standard protocol of any user. The safety of the patient & staff, positional accuracy, temporal accuracy, and dose delivery accuracy are periodically(weekly, quarterly, monthly) estimated using HDR source(Ir-192), treatment planning devices, measurement devices, and overall treatment devices with regard to treatment delivery. The overall measurement results are estimated successfully and assessed its clinical significance. As a result, our HDR brachytherapy units has been very accurate until now. The QA program protocol permits routine clinical use and provides a high confidence level in the accurate operation of HDR units. Therefore, regular QA of HDR brachytherapy is essential for successful treatment.

  • PDF

판독용 모니터 정도관리 항목 및 시행기준안 개발 연구 (A Study on Quality Assurance(QA) Guideline for Diagnostic Monitor)

  • 손기경;성동욱;정해조;정재호;강희두;신진호;이순근;김용환
    • 대한디지털의료영상학회논문지
    • /
    • 제9권1호
    • /
    • pp.53-65
    • /
    • 2007
  • PACS has been run at the Kyung Hee University Medical Center(KHMC) since 2001, and the installation and operation of PACS have contributed to automation and quantification of KHMC's medical environment During these five years our greatest concern is how to make our own guiding principle of diagnostic monitor QA which is adapted to international standards. In accordance with the terms of 'KHMC QA Guideline', 'AAPM TG18', 'SMPTE RP133', 'DICOM Part14', 'DIN V 6868-57', 'JESRA X-0093', 'JIS Z4752-2-5' and 'KCARE', concern about quality assurance of medical images are on the increase. With the investigation of acceptance testing and quality control of international standards for medical display devices, and data collection and analysis for recommended guideline, it is reported that acceptance testing(quality control), including geometrical distortion, display reflection, luminance response, luminance uniformity, display resolution, display noise, veiling glare and color chromaticity being adequate and effective to domestic hospital environments for medical display devices and assessment methods according to each performance. Accordingly, KHMC classified the checkpoint items by period, at the time of monitor setting, monthly, quarterly, half-yearly and annually. Periodic classification of checkpoint items for monitor QA makes a good guideline for image QA/QC and useful guideline for persistent good quality of monitor.

  • PDF

국내 선형가속기의 포괄적인 품질관리체계에 대한 제언 (Suggestion for Comprehensive Quality Assurance of Medical Linear Accelerator in Korea)

  • 최상현;박동욱;김금배;김동욱;이재기;신동오
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.294-303
    • /
    • 2015
  • 미국의학물리학회는 포괄적인 방사선치료기기의 품질관리를 위한 작업그룹(Task Group: TG) 40 보고서를 1994년 발표한 이후로 세기조절방사선치료, 정위적방사선치료, 및 영상유도방사선치료 등의 고정밀 방사선치료를 포함한 선형가속기에 대한 품질관리를 권고하기 위해 2010년에 AAPM TG-142를 발간하였다. 그리고 최근 국내에서도 최신 치료기법에 대한 품질관리의 필요성에 따라 원자력안전위원회는 원자력안전위원회고시 제2015-005호 "의료분야의 방사선안전관리에 관한 기술기준"을 발표하였다. 원자력안전위원회고시에는 각 의료기관에서 품질관리전문인력을 두어 품질관리 조직 및 직무, 품질관리에 필요한 장비, 품질관리 방법/주기/관리오차 및 관리오차 초과 시 조치방법 등에 대한 내용이 포함된 품질관리절차서를 수립하고 품질관리를 수행하도록 규정되어 있다. 이에 따라 의료기관에서는 3차원 입체조형방사선치료, 세기조절방사선치료, 정위적방사선치료 등과 같은 방사선치료유형별(Non-IMRT, IMRT, SRS/SBRT)로 방사선치료기기에 맞는 품질관리 항목, 주기 및 관리오차를 설정하고, 적절한 품질관리 장비 등을 사용하여 기관의 실정에 맞게 품질관리를 수행하여야 한다. 그러나 국내에는 선형가속기의 체계적인 품질관리를 구축할 수 있는 지침서나 학회 보고서 등이 미비하여 현재 각 의료기관별로 각기 다른 품질관리의 항목, 주기 및 관리오차를 설정하여 품질관리를 수행하고 있는 실정이다. 그러므로 본 논문에서는 방사선치료의 안전성 및 정확성을 확보하기 위해 원자력안전위원회 고시 및 TG-142에 기반한 국내 실정에 적합한 선형가속기에 대한 품질관리체계 구축 방안 등을 제안하였다. 제안된 선형가속기에 대한 품질관리 체계는 다른 고정밀 방사선치료기기 등의 품질관리 체계 구축에도 도움이 될 것으로 사료된다.

전자포탈영상을 이용한 다엽시준기의 정도관리 (Quality Assurance of Multileaf Collimator Using Electronic Portal Imaging)

  • 진호상;;최보영;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.151-160
    • /
    • 2003
  • 삼차원 입체조형방사선치료나 세기조절방사선치료와 같은 다엽시준기(Multileaf Collmator, MLC)를 이용하는 보다 복잡한 방사선 치료 기술은 다엽시준기의 위치 및 운동의 검증의 중요성을 증가시키고 있다. 이러한 다엽시준기의 검증은 신뢰성과 그동안 축척된 경험적 검증능력으로 인하여 주로 필름을 가지고 수행되어왔다. 그러나 전자포탈영상장치(Electornic Portal Imaging Device, EPID)의 사용의 편이성과 디지털 영상 제공 능력은 낮은 임상편이성, 효율성, 비용대 수익률에도 불구하고 정기적인 정도확립(Quality Assurance, QA)에 현실적인 필름의 대체재로 관심을 모아왔다. 본 연구에서는 EPI를 활용한 다엽시준기의 정기적인, 특히 일간 정도확립법을 개발하였다. 정기적 정도확립을 위한 전자포탈영상(Electronic Portal Imaing, EPI)의 적용가능성에 대한 검증은 방사선 조사시 동시에 획득된 필름과 다엽시준기의 제어장치에 입력한 다엽시준기의 처방과의 비교를 통해 수행되었다. 특별히 설계된 두가지 형태의 시험형(test pattern)이 영상 획득 및 비교에 적용되었다. 정성적인 온라인 육안 검증과 함께 윤곽 검출 알고리듬을 이용한 정량적인 오프라인 분석이 검증 절차에 이용되었다. 결론적으로, 본 연구에서 개발된 EPI를 이용한 다엽시준기의 일간 정도확립법은 필름의 정확도를 가지고 편리하게 수행될 수 있었다.

  • PDF

소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가 (Evaluation of the Utility of a Volumetric Modulated Arc Therapy Specific Patient Quality Assurance using Software-based Quality Assurance System)

  • 강동진;정재용;신영주;민정환;김연래;권경태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.39-45
    • /
    • 2018
  • The purpose of this study is to evaluate the usefulness of a software-based quality assurance system based on Volumetric Modulated Arc Therapy treatment plan. Evaluate treatment plan through the D VH analysis, PTV mean dose ($D_{mean}$) and PTV 95% dose($D_{95}$) compare the MFX based on original treatment plan, Average error rate was $0.9{\pm}0.6%$, $1.0{\pm}0.8%$, respectively. Measuring point dose using phantom and ion chamber, the average error rate between the ionization chamber and MFX was $0.9{\pm}0.7%$, $1.1{\pm}0.7%$ (high dose region), $1.1{\pm}0.9%$, $1.2{\pm}0.7%$ (low dose region). The average gamma though of MFX and $Delta^{4PT}$ is $98.7{\pm}1.2%$, $98.4{\pm}.3%$, respectively. Through this study, A software based QA system that simplifies hardware based QA procedures that involve a lot of time and effort. It can be used as a simple and useful tool in clinical practice.