• 제목/요약/키워드: purity analysis

검색결과 496건 처리시간 0.03초

프라이자흐 모델과 유한요소법을 이용한 C.P.M의 착자 특성 해석 (Magnetizing Analysis of a Convergence Purity Magnet using Preisach model and Finite Element Method)

  • 윤태호;권병일;박승찬;우경일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권11호
    • /
    • pp.729-736
    • /
    • 2000
  • This paper deals with the characteristic analysis of magnetizer for convergence purity magnet by the finite element method. The analysis utilizes combined method of the time-stepped finite element analysis and the Preisach model with hysteresis phenomena. In the finite element analysis, the non-linearity and the eddy current of the magnetizing fixure and permanent-magnet are taken account. The magnetization distribution in the permanent magnet is determined by using Preisach model which are composed of Everett function table and the first order transition curves is obtained by the Vibrating Sample Magnetometer. The calculated flux density values on the surface of the permanent magnet are led to the approximated gauss density values measured by the gauss meter. As a result, winding current, copper loss, eddy current loss of the magnetizing yoke, flux plot, surface gauss plot, temperature rise of the coil and resistor variation, vector diagram of magnetization distribution are shown.

  • PDF

키랄 크로마토그래피와 NMR 분광법에 의한 N-acetyl-1-naphthylethylamine의 광학순도 측정 (1Determination of optical purity of N-acetyl-1-naphthylethylamine by chiral chromatography and NMR spectroscopy)

  • 정영한;류재정
    • 분석과학
    • /
    • 제23권1호
    • /
    • pp.97-101
    • /
    • 2010
  • (R)-N-3,5-dinitrobenzoyl (DNB) phenylglycinol로 부터 만들어진 키랄 선택제가 라세미 Nacylnaphthylalkylamines의 분리에 HPLC 키랄 정지상으로 이용된 바 있다. 본 연구에서는 (R)-phenylglycinol 유도체 키랄 선택제를 이용하여 키랄 크로마토그래피와 NMR 분광법에 의한 광학순도를 측정하였다. NMR과 HPLC 실험결과를 참값과 비교하여 각 광학순도 측정값의 정확도와 정밀도를 계산하였다. NMR 방법의 오차는 +2.2%, 평균 RSD는 4.54% 이었고, HPLC 방법의 오차는 -3.5%, 평균 상대표준편차는 3.23% 이었다.

가수분해 방지제 제조용 Phospholene Oxide 촉매의 합성 (Synthesis of Phospholene Oxide Catalysts for Hydrolysis Stabilizers)

  • 이진하;이창용
    • 공업화학
    • /
    • 제26권1호
    • /
    • pp.86-91
    • /
    • 2015
  • BHT (2,6-di-tert-butyl-4-methylphenol), TBC (4-tert-butylcatechol), 스테아린산구리 등 여러 가지 중합방지제를 사용하여 MPPO (3-methyl-1-phenyl-2-phospholene-1-oxide)를 제조하였다. 제조한 시료에 대해 FTIR, $^1H$-NMR, GC/MS 등을 이용하여 분석한 결과 중합방지제의 종류에 관계없이 MPPO 합성이 확인되었다. 반응 시간이 증가하면 MPPO의 수율은 증가하지만, 순도는 약간 저하하는 경향을 보였다. 합성 온도가 높아지면 MPPO의 수율과 순도가 증가하였지만, 스테아린산구리를 사용한 경우 MPPO의 순도 변화는 나타나지 않았다. 중합방지제 양이 증가하면 MPPO의 수율은 변화가 나타나지 않았다. 순도는 중합방지제 양이 증가하면 증가하였지만, BHT를 사용한 경우에는 중합방지제 양에 따른 MPPO의 순도 변화가 없었다. Diphenylcarbodiimide 합성에 대한 MPPO의 촉매 활성은 스테아린산구리를 사용하여 제조한 MPPO가 가장 높았다.

Purity Assessment of Organic Reference Materials with a Mass Balance Method: A Case Study of Endosulfan-II

  • Kim, Seung-Hyun;Lee, Joonhee;Ahn, Seonghee;Song, Young-Sin;Kim, Dong-Kyum;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권2호
    • /
    • pp.531-538
    • /
    • 2013
  • A mass balance method established in this laboratory was applied to determine the purity of an endosulfan-II pure substance. Gas chromatography-flame ionization detector (GC-FID) was used to measure organic impurities. Total of 10 structurally related organic impurities were detected by GC-FID in the material. Water content was determined to be 0.187% by Karl-Fischer (K-F) coulometry with an oven-drying method. Non-volatile residual impurities was not detected by Thermal gravimetric analysis (TGA) within the detection limit of 0.04% (0.7 ${\mu}g$ in absolute amount). Residual solvents within the substance were determined to be 0.007% in the Endosulfan-II pure substance by running GC-FID after dissolving it with two solvents. The purity of the endosulfan-II was finally assigned to be ($99.17{\pm}0.14$)%. Details of the mass balance method including interpretation and evaluating uncertainties of results from each individual methods and the finally assayed purity were also described.

암모늄 디나이트라마이드염의 합성 및 액상연료화 연구 (Preparation of High Purity Ammonium Dinitramide and Its Liquid Mono-propellant)

  • 김우람;박미정;김소희;전종기;조영민
    • 공업화학
    • /
    • 제30권5호
    • /
    • pp.591-596
    • /
    • 2019
  • 친환경 대체연료물질로서 ammonium dinitramide (ADN, $NH_4N(NO_2)_2$)는 상온에서 안전하고, 안정하지만 실제 적용을 위해서는 고순도가 요구된다. 소량의 불순물은 단일계 액상연료용 추력기 내 촉매의 분해반응을 억제하며, 비추력을 저하시키고, 노즐 막힘과 같은 부작용을 초래한다. 따라서 본 연구는 반복추출, 활성탄에 의한 흡착, 그리고 저온추출방법을 적용하여 합성한 ADN을 정제하였고, FT-IR, UV-Vis 및 IC 분석을 통하여 화학적인 순도를 평가하였으며, 최종 순도로서 IC 분석기준으로 99.82%를 획득하였다. 또한, ADN을 주 산화제로 활용하는 액상연료를 제조하였으며, 최소 $148^{\circ}C$에서 분해되는 단일계 추진제를 합성하였다. 그러나 상안정화를 위하여 우레아를 연료물질로 추가하였을 경우, 분해온도는 $188^{\circ}C$까지 상승하였다.

A pilot study of half-value layer measurements using a semiconductor dosimeter for intraoral radiography

  • Shun Nouchi;Hidenori Yoshida;Yusaku Miki;Yasuhito Tezuka;Ruri Ogawa;Ichiro Ogura
    • Imaging Science in Dentistry
    • /
    • 제53권3호
    • /
    • pp.217-220
    • /
    • 2023
  • Purpose: This pilot study was conducted to evaluate half-value layer (HVL) measurements obtained using a semiconductor dosimeter for intraoral radiography. Materials and Methods: This study included 8 aluminum plates, 4 of which were low-purity (less than 99.9%) and 4 high-purity (greater than 99.9%). Intraoral radiography was performed using an intraoral X-ray unit in accordance with the dental protocol at the authors' affiliated hospital: tube voltage, 60 kVp and 70 kVp; tube current, 7 mA; and exposure time, 0.10 s. The accuracy of HVL measurements for intraoral radiography was assessed using a semiconductor dosimeter. A simple regression analysis was performed to compare the aluminum plate thickness and HVL in relation to the tube voltage (60 kVp and 70 kVp) and aluminum purity (low and high). Results: For the low-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the thickness of the aluminum plate (X), with Y=1.708+0.415X (r=0.999, P<0.05) and Y=1.980+0.484X (r=0.999, P<0.05), respectively. Similarly, for the high-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the plate thickness(X), with Y=1.696+0.454X (r=0.999, P<0.05) and Y=1.968+0.515X (r=0.998, P<0.05), respectively. Conclusion: This pilot study examined the relationship between aluminum plate thickness and HVL measurements using a semiconductor dosimeter for intraoral radiography. Semiconductor dosimeters may prove useful in HVL measurement for purposes such as quality assurance in dental X-ray imaging.

Spinel Pigment의 생성반응에 관한 연구 (A Study on the Formation of Spinel Pigment(Green Pigment based on Magnesium-Chrome))

  • 이응상;박철원;황성연
    • 한국세라믹학회지
    • /
    • 제12권1호
    • /
    • pp.29-36
    • /
    • 1975
  • This study was conducted to research the formation, color development and application for colored glazes of the spinel solid solutions of the green pigment. On specimens prepared by calcining the oxide and basic carbonate mixture at 1250℃ for 1.5 hour, the x-ray analysis, measurement of reflectance and the test of their stabiality as a glaze pigment were carried out. The results are summarized as follows 1) Each sample is composed of single spinel and not of mixture of spinel. 2) Formation of continuous soild solution, except for a few instances, pertaining to Vegard's law was confirmed by means of the x-ray analysis. 3) The more difference between absorption and reflectance lies, the lighter colors are. When the absorption occurs at the high-reflectance, the excitation purity becomes low. On the contrary when the absorption takes place at the low-reflectance, the excitation purity becomes low. On the contrary when the absorption takes place at the low-reflectance, the excitation purity is higher. 4) Colors obtained in the CdO-MgO-Cr2O3-Al2O3 system, as the amounts of Al3+ increased, change from green through brown to pink, and the absorption peak shifts towards violet region. 5) An increase in Co2+ in the CoO-MgO-Cr2O3-Al2O3 system, changes the color from blue green to dark blue. The excitation purity is higher, and the absorption peak shifts toward regions. 6) Colors are green in the NiO-MgO-Cr2O3 and CdO-MgO-Cr2O3 systems in general, but in the ZnO-MgO-Cr2O3 system brillant hue is not obtained. 70 According to the results of the colored glaze test, the spinels turn outto be stable as brilliant glaze pigment in the calcium-magnesia glaze.

  • PDF

Tandem laser-induced breakdown spectroscopy laser-ablation inductively-coupled plasma mass spectrometry analysis of high-purity alumina powder

  • Lee, Yonghoon;Kim, Hyang
    • 분석과학
    • /
    • 제32권4호
    • /
    • pp.121-130
    • /
    • 2019
  • Alumina is one of the most important ceramic materials because of its useful physical and chemical properties. Recently, high-purity alumina has been used in various industrial fields. This leads to increasing demand for reliable elemental analysis of impurities in alumina samples. However, the chemical inertness of alumina makes the sample preparation for conventional elemental analysis a tremendously difficult task. Herein, we demonstrated the feasibility of laser ablation for effective sampling of alumina powder. Laser ablation performs sampling rapidly without any chemical reagents and also allows simultaneous optical emission spectroscopy and mass spectrometry analyses. For six alumina samples including certified reference materials and commercial products, laser-induced breakdown spectroscopy (LIBS) and laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) analyses were performed simultaneously based on a common laser ablation sampling. LIBS was found to be useful to quantify alkali and alkaline earth metals with limits-of-detection (LODs) around 1 ppm. LA-ICP-MS could quantify transition metals such as Ti, Cu, Zn, and Zr with LODs in the range from a few tens to hundreds ppb.

고순도 수소가스내에 존재하는 불순물의 분석 연구: 대기압 이온화 질량분석기의 이용 (An impurity analysis study in ultra high purity Hydrogen stream: The utilization of Atmosperic Pressure Ionization Mass Spectrometer)

  • 이효석;이택홍
    • 한국수소및신에너지학회논문집
    • /
    • 제16권3호
    • /
    • pp.290-295
    • /
    • 2005
  • For the application of fuel cell, the content and concentration of impurities in hydrogen stream must be classified. The purpose of this study is to provide analysis tool for the determination of impurities in hydrogen with ultra high purity. To produce UHT hydrogen, we purified hydrogen gas by both getter-based catridge and liquid-nitrogen soaked catridge. We compare two methods and propose new method to know about what is in hydrogen stream.

Nutritional Flexibility of Oligotrophic and Copiotrophic Bacteria Isolated from Deionzed-ultrapure Water Made by High-purity Water Manufacturing System in A Semiconductor Manufacturing Company

  • Kim, In-Seop;Kim, Seung-Eun;Hwang, Jung-Sung
    • Journal of Microbiology and Biotechnology
    • /
    • 제7권3호
    • /
    • pp.200-203
    • /
    • 1997
  • Bacteria isolated from ultrapure water made by a high-purity water manufacturing system in a semiconductor manufacturing plant were classified into two groups which either grew in diluted nutrient broth medium (oligotrophic bacteria) or could not grow (copiotrophic bacteria). The nutritional flexibility of oligotrophic and copiotrophic bacteria was investigated. The oligotrophic bacteria were shown to be able to utilize a significantly broader range of organic substrates than the copiotrophic bateria. This finding substantiates the hypothesis that nutritional flexibility is adaptive for oligotrophic bacteria.

  • PDF