• 제목/요약/키워드: pumping water

검색결과 645건 처리시간 0.031초

경량골재를 사용한 경량콘크리트의 펌프압송 성능향상에 관한 실험적 연구 (The Experimental Study on improvement the pump sending of the light weight concrete using the light weight aggregate)

  • 박대오;서치호;지석원;이진우;신상태;지석원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.23-26
    • /
    • 2006
  • The study about the concrete to use recently a light weight aggregate, processed actively. And concrete pumping with a high pressure pump has been popularized, the mechanical development, such as high pressure pumps or pipes, is progressing rapidly. Concrete placing by pumping has the advantage of the reduction of the construction period with workability, easiness of work and the increase of placing, but the quality variation of concrete is caused by pumping is seldom considered, including the increase of the pipe length by high-rising and large-sizing, there by the loss of the unit quantity of water, with pumpability or workability deteriorated. In this research, we will compare and analyze before pumping and after pumping samples of ready-mixed light weight concrete. The result of study as follow. The case of a light weight concrete which the low slump is more decrement compared with high slump light weight concrete in after pumping samples. After pumping the water by pressure of a pump was absorbed to the aggregate inside, and it showed an increase of compression strength about $5{\sim}20%$.

  • PDF

먹는샘물 제조업체의 취수량 및 감시정 관리에 관한 고찰 (A Study on the Water Withdrawal Permit Rate and Monitoring Well Management of Bottled Water Manufacturers)

  • 손두기;박승혁;정교철
    • 지질공학
    • /
    • 제29권3호
    • /
    • pp.329-337
    • /
    • 2019
  • 샘물개발허가의 유효기간은 5년이며, 연장허가를 위하여 만료 6개월 전까지 샘물환경영향조사 보고서를 첨부하여 기간 연장을 신청하여야 한다. 제출된 보고서의 심사과정에서 가장 큰 관심은 샘물 취수에 따른 지하수위 강하, 원수 수질분석 및 감시정의 모니터링 결과에 집중된다. 중생대 백악기 지역과 선캠브리아기 변성암 지역에 각각 위치하는 먹는샘물 제조업체의 취수정에 대하여 수중모터펌프의 양수능력과 양수시간을 조절하는 방법으로 수위강하량과의 상관성을 조사하였다. 양수능력을 감소시키는 방법이 매시간 동일하게 양수시간과 회복시간을 조정하는 방법보다 수위강하량을 줄이는데 효과적이었다. 또한 변성암 지역에 설치한 감시정에 대하여 pH센서의 계측자료를 분석한 결과, 설치 후 경과시간에 따라 계속 증가하여 일정한 값에 수렴하는 것으로 조사되어 관리가 어려운 pH항목을 감시정에서 제외하거나 사용자 친화적인 계측방법으로 보완이 필요할 것으로 판단된다.

지하수 개발 및 양수기간에 따른 수위 변동특성 분석 (Analysis of Water Level Fluctuations according to Groundwater Development and Pumping Duration)

  • 김민철;양성기;이준호
    • 한국환경과학회지
    • /
    • 제25권1호
    • /
    • pp.135-146
    • /
    • 2016
  • This study analyzed fluctuations of ground water level of ground water wells developed in Seongsan watershed of Jeju Island until 2013 using MODFLOW, a numerical analysis model. Ground water level shows greater fluctuations from increase of pump capacity compared to the number of ground water wells. The development of ground water at the top of watershed was found to have direct influence on ground water level. Ground water wells developed until 2013 were used to continue pumping for 50 days, and ground water level of coastal region was reduced below 50% compared to the standard water level. In addition, the range of fluctuation of water level was large in the east coast region, which represents the direction of flow of ground water.

공업용수 공급시스템의 효율적인 운영을 위한 시스템다이내믹스 모형의 개발 (Development of a System Dynamics Computer Model for Efficient Operations of an Industrial Water Supply System)

  • 김봉재;박수완;김태영;전대훈
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.383-397
    • /
    • 2012
  • In this study, a System Dynamics (SD) simulation model for the efficient operations of an industrial water supply system was developed by investigating the feedback loop mechanisms involved in the operations of the system. The system was modeled so that as demand is determined the water supply quantity of intake pumping stations and dams are allocated. The main feedback loop showed that many variables such as the combinations of pump operation, unit electric power(kWh/$m^3$), unit electric power costs(won/$m^3$), water level of water way tunnel, suction pressure and discharge of pumping station, and tank and service reservoir water level had causal effects and produced results depending on their causal relationship. The configurations of the model included an intake pumping station model, water way tunnel model, pumping station model (including the tank and service reservoir water level control model), and unit electric power model. The model was verified using the data from the case study industrial water supply system that consisted of a water treatment plant, two pumping stations and four dams with an annual energy costs of 5 billion won. It was shown that the electric power costs could have been saved 7~26% during the past six years if the operations had been based on the findings of this study.

심층 강화학습을 이용한 지능형 빗물펌프장 운영 시스템 개발 (A Development of Intelligent Pumping Station Operation System Using Deep Reinforcement Learning)

  • 강승호;박정현;주진걸
    • 융합보안논문지
    • /
    • 제20권1호
    • /
    • pp.33-40
    • /
    • 2020
  • 하천 인근에 위치한 빗물펌프장은 유수지를 대상으로 적절한 규칙에 따라 펌프를 가동함으로써 도심지 및 농경지 침수 피해를 예방하는 기능을 수행한다. 현재 대부분의 빗물펌프장은 유수지의 수위를 기준으로 단순한 규칙 기반의 펌프운영 정책을 사용하고 있다. 최근 지구온난화로 인한 기후 변화가 예측하기 어려운 강우량의 변화를 발생시키고 있다. 따라서 단순한 펌프정책으로는 지구온난화로 인한 갑작스러운 유수지 변화에 적절하게 대처하기 어렵다. 본 논문은 강우량과 저수량, 유수지 수위 등의 정보를 이용해 시스템이 적정 유수지 수위을 유지할 수 있도록 펌프 가동을 선택할 수 있는 심층 강화학습 기반의 자동 빗물펌프 운용 방법을 제시한다. 제안한 방법의 타당성을 검증하기 위해 강우-유출 모의 모델인 Storm Water Management Model(SWMM)을 이용해 모의실험을 수행하고 현장에서 사용되고 있는 기존 펌프 정책과 성능을 비교하였다.

관정의 배열수 및 양수량의 상호관계에 관한 실험 (Experiment for the Relation Between Arrangement,Numbers and Pumping Rates of Well)

  • 권무남
    • 한국농공학회지
    • /
    • 제11권3호
    • /
    • pp.1707-1718
    • /
    • 1969
  • The purpose of this experiment is to determine the relations between numbers, arrangements and pumping rates of wells. In this experiment, well pipes were vertically set up in an artificial water-bearing sand layer of homogeneous quality. Wells were arranged in different ways and their number was varied in order to observe the variation of pumping rates. Sands were filled in a square tank, $183cm{\times}91.5cm{\times}91.5cm$ so as to secure a water-bearing layer. Water was constantly supplied from a supply tank located at an end of the tank. The number of well pipes was varied from one to four. Well pipes were connected by a horizontal header pipes were connected by a horizontal header pipe located above them and one pump was used. Pumping rates were measured, when they were arranged in longitudinal and lateral directions, They were also arranged in a square and triangle. The main results thus obtained are presented as follows: (1) When well pipes are laid out in a longitudinal line, i. e., in a flow direction, the ratios of pumping rates of one-pipe well and wells 2-, 3- and 4- pipe t, are 1.903, 2.506 and 2.66, respectively. (2) When well pipes are laid out in a lateral line, i.e., in a perpendicular direction to flow, the same ratios as (1) are 1.912, 2.527 and 2.88. (3) When four pipes are laid out in a square and three pipes are laid out in a triangle, pumping rates are deereased, Comparing with the cases when pipes are laid out in a straight line.

  • PDF

강변여과 취수정의 간섭효과와 하천수 비율에 대한 해석적 평가 (Analytical Evaluation of Interference and Ratio of River Water at Riverbank Filtration Pumping Wells)

  • 박남식
    • 한국수자원학회논문집
    • /
    • 제47권8호
    • /
    • pp.685-691
    • /
    • 2014
  • 강변여과는 하천 인근에 다수의 관정을 설치하여 하천수의 수질 개선을 추구하는 기술이다. 그런데 다수의 관정이 인접해 있는 경우 관정간의 상호간섭 현상으로 인하여 취수량에 영향을 미친다. 강변 여과 관정의 경우에는 관정이 관망으로 연결되기 때문에 간섭효과의 요인에는 지하수위 강하량 외에도 유량변화에 따른 관망 수두손실이 포함된다. 간섭효과는 취수정으로 유입되는 하천수와 배후 지하수의 비율에도 영향을 미친다. 본 연구에서는 강변여과시스템의 대수층과 관망흐름을 통합해석하는 기법을 이용하여 복수 관정의 간섭효과와 하천수 비율을 산정하는 방법을 제시하고 실제에 가까운 가상의 강변여과시스템에 적용하였다. 관정 가동 패턴에 따라 취수량은 5% 이상 차이가나고 배후지하수 유입비율도 30~40% 범위로 10% 이상 차이가 날 수 있는 것으로 나타났다.

Design of Micro Water Supply System Using Solar Energy

  • Sharma, Ekisha;Khatiwada, Nawa Raj;Ghimire, Anish
    • 적정기술학회지
    • /
    • 제5권1호
    • /
    • pp.8-17
    • /
    • 2019
  • Solar pumps, for water lift systems, is becoming popular in rural areas for supplying drinking water in dry seasons when its need is elevated. The development in technology has also made solar pumps readily available and cheap which has increased its demands. So, for scattered settlements having a limited budget for operation and maintenance costs, solar pump is preferred over grid connected electrical pumping systems. This primary objective of the study was to design a solar photovoltaic pumping drinking water supply system for a small health post which is about 45 km east from Kathmandu, the capital city of Nepal. The study also compared and verified the final design with the system's existing design prepared by a development agency. The water source for this study was a confined aquifer 115m below the surface. The water demand was calculated to be 11m3 per day. A 1500 kPa submersible pump attached to a motor was selected and installed. Along with that twelve solar panels, reservoir, transmission main and distribution main was designed. The outcomes conclude solar photovoltaic pumping water supply systems to be cost-effective with an estimated cost of only USD 0.84 million per MLD. Solar pumps require low maintenance and operation costs and its repairs can quickly be done by the local people. The study also shows that solar technology produces no sound, needs no fuel making it environmentally friendly.

지하수 양수량에 따른 지하수유동 및 포획구간 특성 변화 (Characteristics of Ground Water Capture Zone according to Pumping Rate)

  • 안승섭;박동일;오영훈
    • 한국환경과학회지
    • /
    • 제22권7호
    • /
    • pp.895-903
    • /
    • 2013
  • This study analyzed on characteristics of the ground-water capture zone in coastal areas and mid-mountainous area according to pumping rate. For this study, it targeted Jejudo island where is the volcanic island. To analyze, MODFLOW model and MODPATH model, which are the ground-water flow analysis models, were used. As a result of research, the following conclusions could be obtained. As a result of analyzing influence of a change in pumping time upon length of capture zone, the length of capture zone in coastal area was indicated to be greater in the changing ratio compared to the length of capture zone in mid-mountainous area. Next, in the coastal area, the pumping rate and the capture-zone length are changing similarly. However, in mid-mountainous area, the length of capture zone was indicated to grow when the pumping rate comes to exceed 1,500m3/day. As a result of analyzing influence of a change in pumping time upon capture area, the tendency of a change in the area was indicated similarly in coastal areas and mid-mountainous area. Especially, it could be known that the larger pumping rate leads to the more definite increase in tendency to a change in capture area. Based on this study, it was allowed to be possibly used in the suitable pumping rate in coastal areas and mid-mountainous area of the volcano island in the future. A follow-up research is judged to necessarily analyze the influence of tubular-well group upon capture zone by additionally analyzing a change in capture zone targeting the concentrated tubular well.