• Title/Summary/Keyword: pumping tests

Search Result 128, Processing Time 0.026 seconds

A Study on the Simple Piped Water Supply System in a Rural Area (일부 농촌지역의 간이 상수도 운영실태와 개선 방안에 관한 조사연구)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.57-66
    • /
    • 1991
  • This study was carried out for 5 years between 1984 and 1986 and 1989 and 1990. This interviewers visited 292 households to evaluate the perception of the residents using .the. Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 42 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are surmnarized as follows: 1) Approximately 55% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 16 sites and valley water in 26 sites. 3) Considering the type of distribution of the SPWS, there are 28 natural gravity systems and 14 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 74% of the SPWS facilities were used more than ten years. In addition, 40% of residents expressed the need for repairs of old facilities. 5) 48% of the SPWS facilities are neighbored with pollution source. 6) 50% of the maintenance crews were not committed totheir job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 85% of the residents answered that SPWS was convenient and helpful. 8) About 57% of the residents complaind that the amount of daily water supply is not adequate. 9) About 74% of the residents felt that the water quality is high for dringking water and therefore, 52% of the facilities were not properly chlorinated. But in contrast, the biochemical tests indicated that only 28% of the SPWS met the dringking water quality standards. 10) Maintenance cost per a household ranges form 500 to 2, 000Won (1 $ = 700 Won) a month. Most of the cost was to cover the power electric charge. For the effective maintenance and arrangement of the facilities, gorvermental financial support for the maintenance is strongly recommended.

  • PDF

A Study on the Drinking Water Quality and Problem of Simple Piped Water Supply System in a Rural Area (일부 농촌지역 간이상수도의 운영실태와 수질에 관한 조사연구)

  • 김영규
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.39-51
    • /
    • 1992
  • This study was carried out for 1 year between 1990 and 1991. The interviewers visited 513 households to evaluate the perception of the residents using the Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 48 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are summarized as follows: 1) Approximately 44.0% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 8 sites and valley water in 40 sites. 3) Considering the type of distribution of the SPWS, there are 40 natural gravity systems and 8 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 73.9% of the SPWS facilities %'ere used more than ten years. 5) 47.4% of the SPWS facilities are neighbored with pollution source. 6) 42.4% of the maintenance crews were not committed to their job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 36.9% of the residents complaind that the amount of daily water supply is not adequate. 8) About 55.6% of the residents felt that the water quality is good for drinking water and therefore, But in contrast, the biochemical tests indicated that most of the SPWS met the drinking water quality standards. 9) Under the present water analysis system, The method of sampling and analysis are not effective, so that analysis system shoud be done by local health center.

  • PDF

Design and Performance Test of a Cryogenic Blower for Space Thermal Environment Simulation (우주 열환경 모사용 소형 극저온 블로워 설계 및 성능평가)

  • Seo, Heejun;Ahn, Sungmin;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.833-839
    • /
    • 2013
  • Thermal vacuum test should be performed prior to launch to verify satellites' functionality in a harsh space environment which is represented by extremely cold temperatures and vacuum conditions. A thermal vacuum chamber which consists of a vacuum vessel, a pumping system, and a thermal control system are used to perform thermal vacuum tests of a satellite system and its components. A cryogenic blower is a core component of the closed loop thermal control system for thermal vacuum chambers. This paper describes the fan design of the cryogenic blower, the design of the thermal protection interface between the driving part and the fluid part, which were verified by thermal and structural analyses. The performance of the cryogenic blower is confirmed by similarity test on the test bench.

A Study on Significant Parameters for Efficient Design of Open-loop Groundwater Heat Pump (GWHP) Systems (개방형 지열시스템의 효율적 설계를 위한 영향인자에 대한 연구)

  • Park, Byeong-Hak;Joun, Won-Tak;Lee, Bo-Hyun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.41-50
    • /
    • 2015
  • Open-loop groundwater heat pump (GWHP) system generally has benefits such as a higher coefficient of performance (COP), lower initial cost, and flexible system size. The hydrogeological conditions in Korea have the potential to facilitate the use of the GWHP system because a large number of monitoring wells show stable groundwater temperatures, shallow water levels, and high well yields. However, few studies have been performed in Korea regarding the GWHP system and the most studies among them dealt with Standing Column Well (SCW). Because the properties of the aquifer have an influence on designing open-loop systems, it is necessary to perform studies on various hydrogeological settings. In this study, the hydrogeological and thermal properties were estimated through various tests in the riverside alluvial layer where a GWHP system was installed. Under different groundwater flow velocities and pumping and injection rates, a sensitivity analysis was performed to evaluate the effect of such properties on the design of open-loop systems. The results showed that hydraulic conductivity and thermal dispersivity of the aquifer are the most sensitive parameters in terms of performance and environmental aspects, and sensitivities of the properties depend on conditions.

Feasibility and Filtering Efficiency of Geotextile Tube Structure with Polymer Material (지오텍스타일 재질에 따른 필터성능 및 튜브구조물 적용성 분석)

  • Oh, Young-In;Shin, Eun-Chul;Kim, Sung-Yoon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.1
    • /
    • pp.7-15
    • /
    • 2005
  • In recent years, the geotextile tubes filled with dredged material have been used in dike and breakwater construction for a number of projects around the world, and their use in this field is growing very fast. One of the most attractive advantages of geotextile tube technology is can be use the in-situ filling materials by hydraulic pumping, it can be also established lower costs and fast construction than other technology. Geotextiles form one of the two largest groups of geosynthetics and it is commonly made by two major types of polymer material(Polypropylene, Polyester). The objective of this paper is to examine several issues associated with drainage function and feasibility of geotextile tube structure such as filtering efficiency, dewatering efficiency, and filling process with polymer materials. Based on the laboratory filtering test and in-situ tests, polypropylene goetextile is more effective for drainage function of geotextile tube technology.

  • PDF

Investigation on the Penetration Resistance of Suction Bucket Foundation in Sand using Model Test (모형실험을 통한 모래지반에서 석션버켓기초의 관입저항력 평가)

  • Kim, Keunsoo;Kwon, Osoon;Oh, Myounghak;Jang, Insung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.6
    • /
    • pp.75-83
    • /
    • 2014
  • Suction bucket foundation is installed with the differential pressure created by pumping water out of bucket. Bucket foundation has usually been utilized in mooring anchor for offshore platform or floating oil and gas production facilities in the open sea. After suction bucket foundation successfully was applied as the foundation for offshore wind turbines in Europe, it recently attracts much attention in Korea, too. To estimate the penetration resistance of the suction bucket foundation is one of the important matters that should be considered during its installation. This study carried out a series of model tests to investigate the penetration resistance of suction bucket foundation. And the mobilized soil strength factor was reviewed through comparing the experimental results by two installation ways (e.g., push-in-load and suction) and the results calculated by the conventional equation.

Performance of HFC32/HFC125 Mixtures for Heat Pumps (HFC32/HFC125 혼합냉매의 히트펌프 성능 평가)

  • Kim, Wook-Jin;Kang, Dong-Gyu;Lee, Yo-Han;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.791-798
    • /
    • 2011
  • In this study, performance of R410A(50%R32/50%R125) and HFC32/HFC125 mixture is measured to examine the effect of composition shift of R410A used for various air-conditioners and heat pumps. The composition of HFC32/HFC125 mixture varies from the reference composition of R410A ${\pm}10%$ with 5% interval. Tests carried out in a heat pump bench tester at the evaporation and condensation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ for summer and winter conditions, respectively. Test results show that both the coefficient of performance (COP) and compressor power of the HFC32/HFC125 mixture have the maximum difference of 2.0% as compared to those of R410A. Compressor discharge temperatures of HFC32/HFC125 mixture are increased up to $6.7^{\circ}C$ as compared to that of R410A. The amount of charge for HFC32/HFC125 mixture vary within 5.6% as compared to that of R410A. Overall, performance of R410A is not appreciably affected by the composition shift of ${\pm}10%$ of R32 under both air-conditioning and heat pumping conditions.

Water-hammer in the Pump Pipeline System with and without an Air-Chamber (에어챔버 설치에 따른 펌프관로계의 수격현상)

  • Lee, Sun-Kon;Yang, Cheol-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • When the pumps stopped in the operation by the power failure, the hydraulic transients take place in the sudden change of a velocity of pipe line. Each and every water hammer problem shows the critical stage to be greatly affected the facts of safety and reliability in case of power failure. The field tests of the water hammer executed at Cheong-Yang booster pump station having an air chamber. The effects were studied by both the practical experiments and the CFD(Computational Fluid Dynamics : Surge 2008). The result states that the system with water hammering protection equipment was much safer when power failure happens. The following data by a computational fluid dynamic analysis are to be shown below, securing the system stability and integrity. (1) With water hammering protection equipment. (1) Change of pressure : Up to $15.5\;kg/cm^2$ in contrary to estimating $16.88\;kg/cm^2$. (2) Change rate of water level : 52~33% in contrary to estimating 55~27%. (3) Note that the operational pressure of pump runs approx. 145 m, lowering 155 m of the regularity head of pump. (4) Note that the cycle of water hammering delays from 80 second to 100 second, together with easing the function of air value at the pneumatic lines. (2) Change of pressure without water hammering protection equipment : Approximate $22.86\;kg/cm^2$. The comprehensive result says that the computational fluid dynamics analysis would match well with the practical field-test. It was able to predict Max. or Min. water hammering time in a piping system. This study aims effectively to alleviate water hammering in a pipe line to be installed with air chamber at the pumping station and results in making the stability of pump system in the end.

Performance of R290 and R1270 as Alternative Refrigerants of R22 According to Temperature Variations of Evaporator and Condenser (증발기와 응축기 온도변화에 따른 R22 대체냉매 R290 및 R1270의 성능평가)

  • Baek In-Cheol;Park Ki-Jung;Shim Yun-Bo;Jung Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.761-767
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons R290 and R1270 was measured in an attempt to substitute R22 under 3 different temperature conditions. They were tested in a refrigerating bench tester with a hermetic rotary compressor. The test bench provided about 3.5 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ and $-21/28^{\circ}C$ in the evaporator and condenser, respectively. Test results show that the coefficient of performance (COP) of these refrigerants is up to 11.54% higher than that of R22 in all temperature conditions. Compressor discharge temperatures were reduced by $14{\sim}31^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 58% as compared to R22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for residential air-conditioning and heat pumping application.

Performance Evaluation of R22 Alternative Refrigerants According to Temperature Variations of Evaporator and Condenser (증발기와 응축기 온도변화에 따른 R22 대체냉매의 성능평가)

  • Baek, In-Cheol;Shim, Yun-Bo;Jung, Dong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.58-63
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons and 3 mixtures was measured in an attempt to substitute R22 under 3 different temperature conditions. The mixtures were composed of R1270(propylene), R290(propane) and R152a. They were tested in a refrigerating bench tester with a hermetic rotary compressor The test bench provided about 3.5 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of $7^{\circ}C/45^{\circ}C$ and $-7^{\circ}C/41^{\circ}C$ and $-21^{\circ}C/28^{\circ}C$ in the evaporator and condenser, respectively. Test results show that the coefficient of performance (COP) of these refrigerants is up to 11.54% higher than that of R22 in all temperature conditions. Compressor discharge temperatures were reduced by $14{\sim}31^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 58% as compared to R22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for residential air-conditioning and heat pumping application.

  • PDF