• Title/Summary/Keyword: pump power

Search Result 1,421, Processing Time 0.032 seconds

A Study on the Application of the Solar Energy Seasonal Storage System Using Sea water Heat Source in the Buildings (해수냉열원을 이용한 태양열계간축열시스템의 건물냉방 적용에 관한 연구)

  • Kim, Myung-Rae;Yoon, Jae-Ock
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.56-61
    • /
    • 2009
  • Paradigm depending only on fossil fuel for building heat source is rapidly changing. Accelerating the change, as it has been known, is obligation for reducing green house gas coming from use of fossil fuel, i.e. reaction to United Nations Framework Convention on Climate Change. In addition, factors such as high oil price, unstable supply, weapon of petroleum and oil peak, by replacing fossil fuel, contributes to advance of environmental friendly renewable energy which can be continuously reusable. Therefore, current new energy policies, beyond enhancing effectiveness of heat using equipments, are to make best efforts for national competitiveness. Our country supports 11 areas for new renewable energy including sun light, solar heat and wind power. Among those areas, ocean thermal energy specifies tidal power generation using tide of sea, wave and temperature differences, wave power generation and thermal power generation. But heat use of heat source from sea water itself has been excluded as non-utilized energy. In the future, sea water heat source which has not been used so far will be required to be specified as new renewable energy. This research is to survey local heating system in Europe using sea water, central solar heating plants, seasonal thermal energy store and to analyze large scale central solar heating plants in German. Seasonal thermal energy store necessarily need to be equipped with large scale thermal energy store. Currently operating central solar heating system is a effective method which significantly enhances sharing rate of solar heat in a way that stores excessive heat generating in summer and then replenish insufficient heat for winter. Construction cost for this system is primarily dependent on large scale seasonal heat store and this high priced heat store merely plays its role once per year. Since our country is faced with 3 directional sea, active research and development for using sea water heat as cooling and heating heat source is required for seashore villages and building units. This research suggests how to utilize new energy in a way that stores cooling heat of sea water into seasonal thermal energy store when temperature of sea water is its lowest temperature in February based on West Sea and then uses it as cooling heat source when cooling is necessary. Since this method utilizes seasonal thermal energy store from existing central solar heating plant for heating and cooling purpose respectively twice per year maximizing energy efficiency by achieving 2 seasonal thermal energy store, active research and development is necessarily required for the future.

  • PDF

Research to Predict the Thermal Characteristics of Electro Hydrostatic Actuator for Aircraft (항공기용 전기-정유압식 작동기(Dual Redundant Asymmetric Tandem EHA)의 열특성 예측을 위한 연구)

  • Kim, Sang Seok;Park, Hyung Jun;Kim, Daeyeon;Kim, Dae Hyun;Kim, Sang Beom;Lee, Junwon;Choi, Jong Yoon
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.3
    • /
    • pp.84-92
    • /
    • 2022
  • The electro-hydrostatic actuator (EHA) recently has been used in flight control fields for aircraft because of its benefits of minimizing oil leakage and weight, improving safety, and etc. while independently operating the hydraulic power source and eliminating complex hydraulic piping. The aircraft of which EHA is installed inside, has the thermal management issue of EHA, because of its limited cooling source as compared with the aircraft which installs the traditional central hydraulic system. So, the thermal analysis model which predicts the thermal characteristics of EHA, is required to resolve this thermal management issue. In this study, an oil circulation circuit inside the hydraulic power module comprised of hydraulic pump and electrical motor for EHA was applied. This is for the purpose of developing the internal rotary group of hydraulic power module, which operates under the conditions of high rotation speed and hydraulic pressure. After formulating an appropriate thermal analysis model, the thermal analysis results with oil cooled or no oil cooled hydraulic control module were compared and reviewed, for the purpose of predicting the thermal characteristics of EHA.

Development of Dispenser System with Electrohydrodynamic and Voice Coil Motor for White Light Emitting Diode (백색 LED 제조를 위한 정전기력과 보이스코일모터를 이용한 디스펜서 시스템 개발)

  • Kang, Dong-Seong;Kim, Ki-Beom;Ha, Seok-Jae;Cho, Myeong-Woo;Lee, Woo-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6925-6931
    • /
    • 2015
  • LED(Light Emitting Diode) is used in various filed like a display because of low power consuming, long life span, high brightness, rapid response time and environmental-friendly characteristic. General fabrication method is combination blue light LED chip with yellow fluorescent substance. Because this way is suitable for industry field in terms of convenience, economic, efficiency. In white light LED packaging process, encapsulation process that is dispensing fluorescent substance with silicon to blue light LED chip is most important. So, in this paper we develop EHD pump system using voice coil motor and electrostatic pump for dispensing fluorescent substance. For these things we conduct basic test about liquid surface profiles by voltage and process time. Through this data we decide optimal process condition and verify the optimal condition using design of experiment method. And to confirm uniformity of the condition, we conduct repeat dispensing test.

Preparation of Pt Catalysts for 2-propanol Dehydrogenation using Sol-gel Method (솔-젤법을 이용한 2-propanol 탈수소화 반응 Pt 촉매의 제조)

  • Lee, Yeong-Kweon;Lee, Hwaung;Song, Hyung Keun;Na, Byung-Ki
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.328-334
    • /
    • 2007
  • Chemical heat pump system of 2-propanol/acetone/hydrogen is most suitable to the recovery of waste heat of power plant. various types of 5 wt% Pt-alumina catalysts were prepared for 2-propanol dehydrogenation using sol-gel method. The characteristics and the dehydrogenation reaction rate of each catalyst were investigated. Pt-alumina xerogel catalyst has excellent reaction rate and good durability in comparison with the existing alumina supported Pt catalysts. Pt-alumina aerogel catalyst had the highest reaction rate in all prepared catalysts, but sufficient aging time was necessary to maintain its reaction rate. A potential advantage of the aerogel catalyst is the fact that the high temperature heat treatment is not required. Without heat treatment or with low temperature heat treatment, the Pt-alumina aerogel catalyst has excellent reaction rate as well as durability and this gives us the economic advantage. Alumina xerogel supported Pt catalyst prepared by incipient wetness method showed good reaction rate, and had good mechanical strength. Blank alumina xerogel prepared by sol-gel method can be used for the support of metal catalysts.

Performance Test of a 7 tonf Liquid Rocket Engine Turbopump (7톤급 액체로켓엔진용 터보펌프 조립체 성능시험)

  • Kwak, Hyun Duck;Kim, Dae-Jin;Kim, Jin-Sun;Kim, Jinhan;Noh, Jun-Gu;Park, Pyun-Goo;Bae, Jun-Hwan;Shin, Ju-Hyun;Yoon, Suck-Hwan;Lee, Hanggi;Jeon, Seong-Min;Jeong, Eunhwan;Choi, Chang-Ho;Hong, Soon-Sam;Kim, Seong-Lyong;Kim, Seung-Han;Han, Yeong-Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.65-72
    • /
    • 2015
  • Performance tests of a turbopump for the developing 7-tonf liquid rocket engine were conducted. The performance of turbopump components and their power matching were measured and examined firstly under the LN2 and water environment. In the real propellant(LOX and kerosene) environment tests, design and off-design performances of turbopump were fully verified. During the off-design tests, turbopump running time was set the same as engine operating time and pump inlet pressure were set lower than nominal operating value in order to investigate pump suction capability. It have been verified that subject turbopump satisfies required performance - flow rate, head, suction performance and operational time - in the operating regime of developing liquid rocket engine.

Simulation Implementation of Fossil Power Plant Condensate Pumps' Rotation Operation Logic Using MATLAB/Simulink (MATLAB/Simulink를 이용한 화력발전소 복수펌프 순환기동로직 시뮬레이션 구현)

  • Yoon, Chang-Sun;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.693-699
    • /
    • 2016
  • The simulators for pump operation developed by domestic or overseas research have been developed for dynamic analysis or operator training purposes. However, previous developed simulators focused on the operators so they are unsuitable for logic designers or commissioning engineers who need to change the operation conditions or logics arbitrarily. In addition, the simulator for two or more condensate pumps' operation, which can be used easily by plant designers or operators, has not been developed. Accordingly, this paper suggests a simulation method that can be used easily for plant designers or operators using MATLAB Simulink. This suggestion helps users who can use MATLAB to implement ANSI/ISA S5.2, which is applied mainly for DCS (Distributed Control System). In addition, to implement the logics specified in the CODE, Sub-Systems were created for the block and evaluated to determine if they can be used in the simulator. In the working level stage using the suggested method, all error possibilities that might occur during the three pumps' rotation operation could be verified with the suggested simulator during the design stage or before operation.

Combined Inland-River Operation Technique for Reducing Inundation in Urban Area: The Case of Mokgam Drainage Watershed (도시지역의 침수저감을 위한 내외수 연계 운영 기법 개발: 목감천 유역을 중심으로)

  • Kwon, Soon Ho;Jung, Hyun Woo;Hwang, Yoon Kwon;Lee, Eui Hoon;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.257-266
    • /
    • 2021
  • Urban areas can often suffer flood damage because of the more frequent catastrophic rainfall events from climate change. Flood mitigation measures consist of (1) structural and (2) non-structural measures. In this study, the proposed method focused on operating an urban drainage system among non-structural measures. The combined inland-river operation technique estimates the inflow of pump stations based on the water level obtained from a preselected monitoring point, and the pump station expels the stored rainwater to the riverside based on those estimates. In this study, the proposed method was applied to the Mokgam drainage watershed, where catastrophic rainfall events occurred (i.e., 2010- and 2011-years), and severe flood damage was recorded in Seoul. Using the proposed method, the efficiency of flood reduction from the two rainfall events was reduced by 34.9 % and 54.4 %, respectively, compared to the current operation method. Thus, the proposed method can minimize the flood damage in the Mokgam drainage watershed by reserving the additional storage space of a reservoir. In addition, flooding from catastrophic rainfall can be prevented, and citizens' lives and property in urban areas can be protected.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

A Case Study of Different Configurations for the Performance Analysis of Solid Oxide Fuel Cells with External Reformers (외부 개질형 평판형 고체 산화물 연료전지 시스템 구성법에 따른 효율특성)

  • Lee, Kang-Hun;Woo, Hyun-Tak;Lee, Sang-Min;Lee, Young-Duk;Kang, Sang-Gyu;Ahn, Kook-Young;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.343-350
    • /
    • 2012
  • A planar solid oxide fuel cell (PSOFC) is studied in its application in a high-temperature stationary power plant. Even though PSOFCs with external reformers are designed for application from the distributed power source to the central power plant, such PSOFCs may sacrifice more system efficiency than internally reformed SOFCs. In this study, modeling of the PSOFC with an external reformer was developed to analyze the feasibility of thermal energy utilization for the external reformer. The PSOFC system model includes the stack, reformer, burner, heat exchanger, blower, pump, PID controller, 3-way valve, reactor, mixer, and steam separator. The model was developed under the Matlab/Simulink environment with Thermolib$^{(R)}$ modules. The model was used to study the system performance according to its configuration. Three configurations of the SOFC system were selected for the comparison of the system performance. The system configuration considered the cathode recirculation, thermal sources for the external reformer, heat-up of operating gases, and condensate anode off-gas for the enhancement of the fuel concentration. The simulation results show that the magnitude of the electric efficiency of the PSOFC system for Case 2 is 12.13% higher than that for Case 1 (reference case), and the thermal efficiency of the PSOFC system for Case 3 is 76.12%, which is the highest of all the cases investigated.

Development of the Automatic Fishing System for the Anchovy Scoop nets (I) - The hydraulic winder device for the boom control - (멸치초망 어업의 조업자동화 시스템 개발 (I) -챗대 조작용 유압 권양기 개발-)

  • 박성욱;배봉성;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.166-174
    • /
    • 2000
  • Anchovy, EngrauEis japonica scoop nets are used in the coastal of Southern and Cheju of Korea. Especially in the Cheju, the fishing gear of scoop nets consists of upper boom, lower boom, pressing stick and bag net. They are operated by fishing boats of 6 to 10 ton class and 8 persons on board. The booms are controlled by side drum, and the net and pressing stick are hauled by only human power in operating. Therefore this fishery needs to large labor and heavy human power and has much risk. Three kinds of hydraulic winding device which controls two booms was designed and manufactured to reduce heavy labor force of scoop nets, and trial in the sea was carried out to test their performances using the commercial fishing boats of 6 ton class. The proper capacity of hydraulic pump and motor were determined by model test of boom 1/5 scale. The results obtained are as follows, 1. Tension of boom which is being drawn was the strongest and 187.5kgf when the boom's end is in the depth of 4m under the water. 2. The hydraulic motor of the fittest kind of winder has the least leakage per time than the other kinds. 3. In the best type of several winder devices, when the pressure difference was fixed $130kg/^2$ for the safe fishery, the winding velocity of boom line was 2m/sec, is faster 0.48/sec than traditional fishing method and this winder can catch the anchovy of 1.6 tonnage. 4. As a result, the crew were decreased from 8 to 6 and the problem of heavy human power and risk on fishing operation were solved by using the this winder.