• 제목/요약/키워드: pump energy

검색결과 1,441건 처리시간 0.029초

서보모터를 이용한 유압 하이브리드식 사출성형기의 공정시간 및 절전효과에 관한 연구 (A Study on Cycle Time and Power Saving Effect of a Hydraulic Hybrid Injection Molding Machine using a Servo Motor)

  • 윤홍식;김성동
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권3호
    • /
    • pp.15-25
    • /
    • 2020
  • The cycle time and power saving effect of a hydraulic hybrid injection molding machine using a servo motor are considered in this paper. In order to verify control characteristics, such as pressure and speed, experiments were performed with the hydraulic hybrid injection molding machine, clamping force of 110 ton. The power consumption and production cycle time of a conventional hydraulic injection molding machine were measured to compare its performances with the hydraulic hybrid injection molding machine. An injection molding machine with a clamping force of 1300 ton was used as the conventional machine, the hybrid machine was implemented by replacing its induction motors with servo motors. In the remodeled hybrid machine, experiments were performed to investigate how the displacement of the mold clamping pump affects the power consumption and production cycle time. The results showed that the production cycle time of the hybrid injection molding is similar to a conventional hydraulic injection molding machine but with a significant energy saving of about 40%.

극저온 유체내에서 운행하는 물체 주위의 공동현상 해석에 관한 연구 (Numerical Study of Cavitating flow around Axysimmetric and 2D Body in Cryogenic Fluid)

  • 이세영;유정민;이창진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.309-312
    • /
    • 2007
  • 액체 로켓의 추진제로 이용되는 극저온 유체는 발사체의 경량화를 위한 터보 펌프의 고속화로 인해 공동현상이 발생하게 된다. 그러나 극저온 유체는 등온 유체인 물과는 달리 낮은 액상/증기 밀도 비율을 가지며 온도에 민감한 잠열변화율을 갖게 된다. 이에 따라 극저온 유체에서 공동 현상이 발생하게 되면, 증발 냉각 현상이 발생하게 되어 공동 내부와 주 유체 사이의 온도 차이가 발생하게 된다. 따라서 이러한 극저온 유체의 특징을 반영해 주기 위해 기존의 경험적 공동 현상 모델을 수정하여 새로운 모델을 적용하였다. 또한 온도 변화에 따른 효과를 반영해 주기 에너지 방정식을 첨가 하였다.

  • PDF

무인 항공기용 연료 전지 동력 시스템 개발 (Development of Fuel Cell Power System for Unmanned Aerial Vehicle)

  • 김태규;심현철;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.87-90
    • /
    • 2007
  • 장기 체공 무인 항공기를 위한 연료 전지 동력 시스템을 개발하였다. 기존의 고압 수소 저장 방식의 문제점을 해결하기 위해 높은 에너지 밀도를 갖는 액상의 화학 수소화물을 연료로 사용하였다. 수소화물을 전환하여 수소를 발생하는 연료 공급 장치는 촉매 반응기, 펌프, 연료 카트리지, 분리기, 제어기로 구성되어 있으며, 전력을 발생하기 위한 연료전지 스택과 함께 연료 전지 동력 시스템을 무인 항공기에 탑재하였다. 연료 전지 동력 시스템을 무인 항공기에 적용하기 위한 성능 검증을 수행하였다.

  • PDF

Exergy analysis of R717 high-efficiency OTEC power cycle for the efficiency and pressure drop in main components

  • Yoon, Jung-In;Son, Chang-Hyo;Yang, Dong-Il;Kim, Hyeon-Uk;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • 동력기계공학회지
    • /
    • 제17권5호
    • /
    • pp.52-57
    • /
    • 2013
  • In this paper, an analysis on exergy efficiency of high-efficiency R717 OTEC power system for the efficiency and pressure drop in main components were investigated theoretically in order to optimize the design for the operating parameters of this system. The operating parameters considered in this study include turbine and pump efficiency, and pressure drop in a condenser and evaporator, respectively. As the turbine efficiency of R717 OTEC power system increases, the exergy efficiency of this system increases. But pressure drop in the evaporator of R717 OTEC power system increases, the exergy efficiency of this system decreases, respectively. And, in case of exergy efficiency of this OTEC system, the turbine efficiency and pressure drop in a condenser on R717 OTEC power system is the largest and the lowest among operation parameters, respectively.

Characteristics of joint resistance with different kinds of HTS tapes for heater trigger switch

  • Lee, Jeyull;Park, Young Gun;Lee, Woo Seung;Jo, Hyun Chul;Yoon, Yong Soo;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권1호
    • /
    • pp.32-35
    • /
    • 2014
  • Recently, many researches on the system of superconducting power supply and superconducting magnetic energy storage (SMES) using high temperature superconducting (HTS) tapes has been progressed. Those kinds of superconducting devices use the heater trigger switches that have a control delay problem at moments of heating up and cooling down. One way to reduce the time delay is using a different HTS tape at trigger part. For example, HTS tape having lower critical temperature can reduce time delay of heating up and heating down stage for heater trigger operation. This paper deals with resistances joint with different kinds of HTS tapes which have different properties to verify usefulness of the suggested method. Three kinds of commercial HTS tapes with different specifications are selected as samples and two kinds of solders are used for comparison. Joint is performed with temperature and pressure controllable joint machine and the joint characteristics are analyzed under the repeatable conditions.

무선 전자식 장비를 이용한 지중열전도도 측정 기술 (Ground Thermal Conductivity Test with A Wireless Probe)

  • 김지영;이의준;장기창;강은철;고건혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2381-2384
    • /
    • 2008
  • The heat exchange between the Borehole Heat Exchanger(BHE) and the surrounding ground depends directly on ground thermal conductivity k at the certain site. The k is thus a key parameter in designing BHE and coupled geothermal heat pump systems. Currently, although a thermal hydraulic Response Test(TRT) is mostly used in practice, the thermal hydraulic TRT needs additional power and is generally time-consuming. A new, simple wireless probe for hi-speed k determination was introduced in this paper. This technique using a wireless probe is less time-consuming and requires no external source of energy for measurement and predicts local thermal properties by measuring soil temperatures along the depth. Measured temperature data along the depth was analyzed. As a result, the electronic wireless probe can replace the conventional hydraulic TRT method after carrying out the additional research on a lot of local heat flow, etc.

  • PDF

공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션 (Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House)

  • 김주용;민만기;최영돈
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

오메프라졸과 베타-시클로덱스트린과의 포접화합물 형성에 따른 특성 (Studies on the Formation of Inclusion Complex between Omeprazole and $\beta$-cyclodextrin)

  • 소재일;이창현;이계주
    • 약학회지
    • /
    • 제35권5호
    • /
    • pp.372-378
    • /
    • 1991
  • To increase the stability and bioavailability of Omeprazole(OMP), which is used newly as a proton-pump inhibitor, inclusion complex of OMP with $\beta$-cyclodextrin($\beta$-CD) was prepared by coprecipitation method and its characteristics were ascertained by means of solubility test, DSC, IR, and the accelerated stability analysis. The type of OMP inclusion complex is classified as Bs-type on phase solubility diagram, and the stoichiometric ratio of OMP: $\beta$-CD complex is 1:2 and formation constant is 80.82/mole. The solubility of the complex could be increased remarkably by complexation compare with OMP. Degradation process of both OMP and OMP complex followed apparent first-order kinetics, of which degradation rate constants and activation energies are k$_{25}$=8.1$\times$10$^{-4}$/day, E$_{a}$=22 Kcal/mole (OMP), and k$_{25}$=4.65$\times$10$^{-6}$/day, E$_{a}$=35 Kcal/mole (complex), respectively. These results show the increase of the stability and solubility of OMP markedly, therefore it is believed that the improvement of stabilization for OMP by inclusion complexation might be practically available.

  • PDF

주유소 조명 실태와 조도패턴 분석 (Survey on the Current Lighting Level at the Gas Stations and its Analysis on the Illuminance Pattern)

  • 주윤석;임종국;여인선
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.1-6
    • /
    • 1999
  • 이 논문에서는 주유소 조명시설의 실태를 조사하고 주유소의 각 영역별 조도를 측정하여 그 결과를 KS와 IESNA의 기준과 비교하고 주유소의 전체적인 조명패턴을 분석하였다. 주유지역에 있어서 조도는 KS에 제시된 값보다 상당히 높은 반면 IESNA의 기준보다는 대체로 낮음을 알 수 있었다. 그 외의 지역 또한 조도값에 있어서 서로 많은 차이가 발생함을 확인하였다. 이러한 결과로부터 주유소 조명시설의 적절한 유지·보수에 의해 불필요한 에너지 낭비를 줄일 수 있고, 이러한 점을 고려한 설계과정의 필요함을 알 수 있었다. 또한 KS규격에 있어서 다른 나라의 기준과 비교하여 각 영역별 작업특성을 고려한 철저한 평가와 기준설정이 이루어져야 하겠다.

  • PDF

Offshore Plant용 발라스트 제어 시스템에 관한 연구 (A Study on the Ballast Control System for Offshore Plant)

  • 오진석
    • 한국정보통신학회논문지
    • /
    • 제17권12호
    • /
    • pp.2944-2951
    • /
    • 2013
  • 최근 유가 상승과 에너지 소비 확대로 인하여 해양 플랜트가 재조명되고 있다. 이러한 해양 플랜트는 외부 환경에 많은 영향을 받기 때문에 발라스트 시스템을 이용한 자세 제어가 필수적이다. 기존 해양 플랜트의 발라스트 시스템은 펌프 6개와 발라스트 탱크 4개를 이용하여 자세 제어를 수행하였다. 그러나 이러한 시스템은 많은 장비가 설치되어야 함으로 고장에 취약하다. 본 논문에서는 새로운 발라스트 시스템과 그에 따른 IT 기반의 제어 알고리즘을 제안한다. 제안한 시스템과 알고리즘은 시뮬레이터를 제작하여 실험을 진행하였으며, 그 결과 시뮬레이터가 안정적으로 제어됨을 확인하였다.