• Title/Summary/Keyword: pump control

Search Result 1,135, Processing Time 0.026 seconds

A Performance Analysis on a Heat pump with Thermal Storage Adopting Load Response Control Method (부하 대응 제어방식을 적용한 축열식 히트펌프시스템의 성능 해석)

  • Kim, Dong Jun;Kang, Byung Ha;Chang, Young Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.130-142
    • /
    • 2018
  • We use heat pumps with thermal storage system to reduce peak usage of electric power during winters and summers. A heat pump stores thermal energy in a thermal storage tank during the night, to meet load requirements during the day. This system stabilizes the supply and demand of electric power; moreover by utilizing the inexpensive midnight electric power, thus making it cost effective. In this study, we propose a system wherein the thermal storage tank and heat pump are modeled using the TRNSYS, whereas the control simulations are performed by (i) conventional control methods (i.e., thermal storage priority method and heat pump priority method); (ii) region control method, which operates at the optimal part load ratio of the heat pump; (iii) load response control method, which minimizes operating cost responding to load; and (iv) dynamic programming method, which runs the system by following the minimum cost path. We observed that the electricity cost using the region control method, load response control approach, and dynamic programing method was lower compared to using conventional control techniques. According to the annual simulation results, the electricity cost utilizing the load response control method is 43% and 4.4% lower than those obtained by the conventional techniques. We can note that the result related to the power cost was similar to that obtained by the dynamic programming method based on the load prediction. We can, therefore, conclude that the load response control method turned out to be more advantageous when compared to the conventional techniques regarding power consumption and electricity costs.

Experimental Study on the MIMO Control Algorithm of a Multi-Heat Pump Based on PRBS Identification Scheme (PRBS 시스템 규명 기법 적용 멀티 열펌프의 다중입출력 제어특성에 관한 실험적 연구)

  • Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.2
    • /
    • pp.16-24
    • /
    • 2013
  • A multi-heat pump provides the benefits of comfort, energy conservation and easy maintenance. Recently, the multi-heat pump has been widely employed in small and medium-sized buildings. However, the control algorithm of the multi-heat pump are limited in the open literature due to complicated operating conditions. In this study, the MIMO control algorithm using integral optimum regulator was designed and the control performance of it was analyzed. In addition, system model of the control plant was developed by PRBS system identification scheme. The MIMO controller adopting the integral optimum regulator yielded satisfactory control performance results.

A Study on Design and Control of Electro-Hydraulic Pump System (전기.유압펌프 시스템의 설계 및 제어에 관한 연구)

  • 박성환;하석홍;이진걸
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.1062-1070
    • /
    • 1995
  • The study deals with controlling the velocity of hydraulic motor with PI controller through the control of displacement pump which has higher efficiency than valve-controlled system. This was done as follows. First, we modified original displacement pump and designed this electrohydraulic puma system. Second, after experimenting static and dynamic characteristics, we identified system parameter of approximated model. Lastly, to control the velocity of hydraulic motor we controlled the angle of the swash plate of displacement pump. Test carried out in the laboratory shows that transient and steady state response could be improved by PI controller reducing power loss.

Waterhammer for the Intake Pumping Station with the Pump Control Valve (펌프제어밸브를 사용한 취수펌프장에서의 수격현상)

  • Kim, Kyung-Yup;Oh, Sang-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.16-21
    • /
    • 2001
  • The field tests on the waterhammer were carried out for PalDang intake pumping station of the metropolitan water supply 5th stage project. The pumping station was equipped with the pump control valve as the main surge suppression device and the surge relief valve as auxiliary. However, the pump control valve had not been early controlled in the planned closing mode, and the slamming occurred to the valve which abruptly closed during the large reverse flow. Because the pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the shaft of the valve was damaged. It was desirable that the surge relief valve was installed in the pumping station or near the pump exit for the delay of response. After reforming the oil dashpot of the pump control valve, the sliming disappeared and the measured pressure was in fairly good agreement with the results of simulation. In case of three pumps for ${\phi}2,600$ pipeline being simultaneously tripped, the pressure head in the pumping station increased to 95.6 m, and the upsurge caused by the emergency stop of four pumps for ${\phi}2,800$ pipeline was 89.6m. We concluded that the pumping station acquired the safety and reliability for the pressure surge.

  • PDF

A Study on the Optimal Performance Control of Heat Pump System for Heating Mode Operation (열펌프 시스템의 난방 운전 시 최적 성능 제어에 관한 연구)

  • Yoo, Keun-Joong;Lee, Il-Hwan;Lee, Gil-Bong;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.669-674
    • /
    • 2006
  • The optimal control of heat pump performance for heating mode operation was investigated. Fuzzy logic was applied to control the heating performance of heat pump system and superheat at compressor discharge was taken as a control variable. Regression model was adapted to determine the optimal points where COP is maximized. Optimization of fuzzy rule table was investigated to improve operation performance of heat pump system. Experiments were carried out using original fuzzy table and the modified fuzzy rule table for heating mode operation of heat pump system. The results show that control performance of heat pump system with the modified fuzzy rule table was better than that with the original rule table.

  • PDF

Indoor Temperature Control of a Heat Pump Based on Model Predictive Control Considering Energy Efficiency (에너지효율을 고려한 모델예측제어에 기초한 열펌프의 실내온도 제어)

  • 조항철;변경석;송재복;장효환;최영돈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2001
  • In indoor temperature control of a heat pump, a reduction in energy consumption is very important. However, most control schemes for heat pumps have focused only on control performance such s settling time and steady-state error. In this paper, the model predictive control (MPC) which includes the energy-related variable in this cost function is proposed. By computing the control signal minimizing this cost function, the trade-off between energy reduction and temperature control performance can be obtained. Since the MPC required the process model, the dynamic mode of a heat pump is also obtained by the system identification technique. Performance of the proposed MPC considering energy efficiency is compared with the two other control schemes. It si shown that the proposed scheme can consume less energy thant hte others in achieving similar control performance.

  • PDF

Multi-function Control of Hydraulic Variable Displacement Pump with EPPR Valve (전자비례감압밸브를 이용한 가변용량형 유압펌프의 다기능 제어)

  • Jung, Dong-Soo;Kim, Hyong-Eui;Kang, E-Sok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.160-170
    • /
    • 2006
  • If hydraulic pump controlled by mechanical type regulator has more than one control function, the construction of regulator will be very complicated and control performance falls drastically. It is difficult to have more than one control function for hydraulic pump controlled by electronic type hydraulic valve due to the inconsistency of controllers. This paper proposes a multi-function control technique which controls continuously flow, pressure and power by using EPPR(Electronic Proportional Pressure Reducing) valve in swash plate type axial piston pump. Nonlinear mathematical model is developed from the continuity equation for the pressurized control volume and the torque balance for the swash plate motion. To simplify the model we make the linear state equation by differentiating the nonlinear model. A reaction spring is installed in servo cylinder to secure the stability of the control system. We analyze the stability and disturbance by using the state variable model. Finally, we review the control performances of flow, pressure and power by tests using PID controller.

Estimation of Physiological Variables for LVAS Control Using an Axial Flow Blood Pump Model (축류혈액펌프 모델을 이용한 좌심실보조장치 제어를 위한 생리학적 변수의 추정)

  • 최성진
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.12
    • /
    • pp.1061-1065
    • /
    • 2002
  • Sensors need to be implanted to obtain necessary information for LVAS (Left Ventricular Assist System) operations. Size of the sensors can prevent them from being implanted in a patient and reliabilities of the sensors are questionable for a long term use. In this wort we utilize a developed pump model to estimate flow and pressure difference across the pump without implanted sensors and present a method to obtain the physiological variables as aorta pressure and left ventricle pressure from the pump model and pulsatility of flow estimate or pressure difference estimate. These estimated variables can be used for LVAS control as an index or indices.

Path Control with Energy-Saving Load-Sensing for a Cylinder-Load System Using Speed-Controlled Fixed Displacement Pump (속도제어-정용량 펌프를 사용하는 실린더-부하계의 에너지절약-부하감지형 경로제어)

  • Cho, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.3
    • /
    • pp.16-22
    • /
    • 2009
  • This paper deals with the issue of robust position tracking control and energy-saving control for a valve-controlled cylinder system using speed-controlled fixed displacement pump. The whole feedback control system is composed of a pair of interconnected subsystems, that is, valve-controlled cylinder system and load-sensing control system. From experiments it is shown that position tracking control in the load sensing control system can accomplish significant reduction in input energy to pump comparing to a conventional valve-controlled cylinder system, while exhibiting the same position tracking control accuracy.

  • PDF

Simulation on Hydraulic Control Characteristics of Regulator System in Bent-Axis Type Piston Pump

  • Kim, Jong Ki;Oh, Seok Hyung;Jung, Jae Youn
    • KSTLE International Journal
    • /
    • v.1 no.2
    • /
    • pp.101-106
    • /
    • 2000
  • Variable displacement axial piston pumps are widely used for raising the energy level of the fluid in hydraulic systems. And the regulator is the device which regulates the discharge flow of the piston pump by controlling the swivel angle. The regulator receives the hydraulic pilot pressure and controls the pump output flow depending on the machine load and engine speed. This work deals with constant power control (horsepower control) in the design of a regulator by using a bent-axis type piston pump. In order to effectively use engine power, we must keep the horsepower from the engine to the pump constant. Therefore the regulator operates the constant power control. As a result, optimum power usage is obtained by accurately following the power hyperbola. This study focused on developing a simulation model of a regulator. First, the governing equations of the regulator are derived, and analysis is performed by computer simulation, which can identify significant parameters of regulator. As a result, the variation of the swivel angle, flow rate, hyperbolic curve, inner leakage and responsibility are simulated, and significant parameters of a regulator are identified.

  • PDF