• 제목/요약/키워드: pulsed jet

검색결과 48건 처리시간 0.026초

Supersonic Free Jet and Ab initio Studies of Electronic-Vibrational Structures of Fluorene

  • 부봉현;최영식;김택수;강성권;김재룡
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권4호
    • /
    • pp.341-344
    • /
    • 1995
  • Laser-induced fluorescence (LIF) excitation spectra were measured for fluorene (FR) cooled in pulsed supersonic expansions of He in the range 283.7-296.7 nm. Ab initio studies of FR have also been carried out for determining the electronic and vibrational structures by using the standard 3-21G basis sets. In the LIF excitation spectra of FR, highly resolved vibronic bands are observed having the band origin of 33,791 cm-1. The vibrational bands above the electronic origin were assigned on the basis of the well-characterized electronic vibrational bands reported previously and of normal modes of vibrations derived by our HF/3-21G calculations.

헬륨 가스 플로우와 가스 펄스 젯에서 할로겐족 원소들의 레이저유도 플라즈마 방출 스펙트럼 (Laser-induced plasma emission spectra of halogens in the helium gas flow and pulsed jet)

  • 이용훈;최대웅;공용득;남상호;나창운
    • 분석과학
    • /
    • 제26권4호
    • /
    • pp.235-244
    • /
    • 2013
  • 할로겐족 원소들의 강한 원자 방출선들은 진공자외선 영역에 존재하여, 공기 중에서 레이저 펄스를 시료에 집속하여 플라즈마 방출 스펙트럼을 얻어 원소 분석을 수행하기 매우 어렵다. 또한 근적외선 영역에 할로겐족 원소들의 들뜬 전자 상태들 사이의 전이에 의한 원자 방출선들이 존재하는데, 이들은 스타크 효과에 의한 선폭 넓어짐 현상이 매우 커서, 공기 중에서 원소 분석에 충분한 신호 대 잡음비를 얻기 어렵다. 헬륨 가스 플로우를 이용하여 근적외선 영역의 할로겐족 원소들의 원자 방출선들은 레이저유도 플라즈마로부터 관측하였다. 특히, 804.374 nm와 905.833 nm의 아이오딘 원자 방출선들은 레이저유도 플라즈마에서 처음으로 관찰된 것이다. 헬륨 분위기에서 스타크 효과에 의한 선폭 넓어짐 현상과 연속 배경복사의 세기는 현저히 억제되었다. 헬륨 가스 플로우의 유량에 따른 원자 방출선의 세기, 플라즈마 온도, 전자 밀도의 변화를 조사하였다. 이 방법을 이용하여 고무의 난연제 성분에 포함된 염소와 불소를 레이저유도 플라즈마 분광법을 이용하여 검출하였다. 마지막으로 레이저유도 플라즈마 분광법을 이용하여 할로젠 원소들을 검출하는데 헬륨 가스 소모량을 줄일 수 있는 가스 펄스 젯 장치를 제안한다.

수직분사제트에서 다양한 분사각도의 분무궤적 특성에 대한 실험적 연구 (An Experimental Study on the Trajectory Characteristics of Liquid Jet with Canted Injection Angles in Crossflow)

  • 김민기;송진관;황정재;윤영빈
    • 한국추진공학회지
    • /
    • 제12권6호
    • /
    • pp.38-47
    • /
    • 2008
  • 횡방향으로 유입되는 공기유동에서 연료 제트의 액주 및 액적영역의 궤적에 관한 연구를 수행하였다. 실험방법으로는 직접사진촬영방법과 평면레이저유도형광 기법을 사용하여 분석하였다. 본 연구의 목적은 공기유동 방향에 수직으로 분사되는 분무와 분사각도의 분무에서 궤적에 대한 경험식을 도출하여 기존 연구결과와 비교분석하고, 대향분사에서의 궤적에 대한 경험식을 도출하는데 있다. 실험을 통하여 액주 및 액적 영역의 궤적은 연료분사차압, 공기의 유속, 분사기 지름 크기, 분사각도에 의하여 결정되며, 정방향의 분무와 대향분사 결과에 있어서는 실험식 상수의 차이가 있음을 확인하였다.

아음속 수직분사제트에서 액적크기 특성에 대한 실험적 연구 (An Experimental Study on Droplet Size Characteristics of Liquid Jets in Subsonic Crossflow)

  • 김민기;손진관;김진기;황용석;윤영빈
    • 한국분무공학회지
    • /
    • 제12권2호
    • /
    • pp.115-122
    • /
    • 2007
  • The spray characteristics and drop size measurements have been experimentally studied in liquid jets injected into subsonic crossflow. With water as fuel injection velocity, injection angle and atomize. internal flows were varied to provide of jet operation conditions. The injector internal flow was classified as three modes such as a non-cavitation flow, cavitation, and hydraulic flip flows. Pulsed Shadowgraph Photography measurement was used to determine the spatial distribution of the spray droplet diameter in a subsonic crossflow of air. And this study also obtains the SMD (Sauter Mean Diameters) distribution by using Planar Liquid Laser Induced Fluorescence technique. The objectives of this research are get a droplet distributions and drop size measurements of each condition and compare with the other flow effects. As the result, This research has been showned that droplet size were spatially dependent on air-stream velocity, fuel injection velocity, injection angle effects, and normalized distance from the injector exit length(x/d, y/d). There are also different droplet size characteristics between cavitation, hydraulic flip and the non-cavitation flows.

  • PDF

정전분무를 이용한 패턴화된 생물현탁액 액적의 유량에 따른 변화 연구 (Variation of Nutrient Broth Droplets Patterned by Electrospray System with Flow Rates)

  • 정상빈;장경수;이건웅;정의석;허기준;이병욱
    • 한국입자에어로졸학회지
    • /
    • 제11권4호
    • /
    • pp.115-118
    • /
    • 2015
  • An electrospray patterning method has been considered as a new and effective way for controlling very fine droplets. Drop-on-demand patterning for unstained nutrient broth on wafers was newly conducted with an electrospray pulsed jet. The patterns had been made under varying experimental conditions including flow rate, vibration frequency, and translational speed of the electrospray patterning system. In this experiment, especially, variation of nutrient broth droplet was measured under varying flow rate conditions. This new technique has a potential to be applied in biology experiments and hormone medical industry.

An Experimental Study on Angled Injection and Droplet Size Characteristics of Liquid Jets in Subsonic Crossflow

  • Kim, Min-Ki;Song, Jin-Kwan;Hwang, Jeong-Jae;Yoon, Young-Bin
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.486-491
    • /
    • 2008
  • The spray characteristics and drop size measurements have been experimentally studied in liquid jets injected into subsonic crossflow. With water as fuel injection velocity, injection angle and atomizer internal flows were varied to provide of jet operation conditions. The injector internal flow was classified as three modes such as a non-cavitation flow, cavitation, and hydraulic flip flows. Pulsed Shadowgraph Photography measurement was used to determine the spatial distribution of the spray droplet diameter in a subsonic crossflow of air. And this study also obtains the SMD(Sauter Mean Diameters) distribution by using PLLIF(Planar Liquid Laser Induced Fluorescence) technique. The objectives of this research are getting a droplet distribution and drop size measurement of each condition and compare with the other flows effect. As the result, This research have been showed the droplet size were spatially dependent on air-stream velocity, fuel injection velocity, injection angle effects and normalized distance from the injector exit length.(x/d, y/d)There are also different droplet size characteristics between cavitation, hydraulic flip and the non-cavitation flows.

  • PDF

Thermomechanical Effect on the Water Wet Dental Hard Tissue by the Q-switched Er : YAG Laser

  • Y. H. Kwon;Ky0-han Kim
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권2호
    • /
    • pp.231-236
    • /
    • 1999
  • Q-switch된 Er:YAG 레이저를 이용해서 치아표면에 뿜어준 외부의 물로 인해 유도된 열 및 역학적인 효과를 이해하는 것은 free-running Er:YAG 레이저에 의한 절삭효과를 이해하는데 대단히 중요하다. 이는 (파장 하나의 길이가 250 $\mu\textrm{s}$인) free-running 레이저에 의한 한 거 대효과가 본 실험에서 이용한 (파장 하나의 길이가 1 $\mu\textrm{s}$인) Q-switch된 레이저에 의한 미소효과들의 축적이기 때문이다. 치아표면에 물이 있을 때 Q-Switch된 레이저에 의한 절삭률은 그렇치 않은 때에 비해 증가되었다. 치아표면에 물을 뿜어주는 횟수는 절삭률에 영향을 미쳐서 저에너지에서는 더디게 물을 뿜어줄때 놀은 절삭률을 얻었다. 반동압력의 세기는 치아표면 조건에 의존하는데. 표면이 젖을수록 그리고 뿜어준 물의 양이 증가 할 수록, 반동압력의 세기 또한 증가하였다. 이 연구로부터 우리는 1-$\mu\textrm{s}$-길이의 pulsed 레이저에 의해 유도된 열 및 역학적인 효과가 외부에 물이 있을 때 free-running Er:YAG 레이저에 의한 절삭을 이해하는데 중요한 정보를 제공해 준다는 것을 알았다.

  • PDF

열플라즈마에 의한 TiO2-xNx의 합성 및 광촉매 특성 비교 (Synthesis of TiO2-xNx Using Thermal Plasma and Comparison of Photocatalytic Characteristics)

  • 김민희;박동화
    • 공업화학
    • /
    • 제19권3호
    • /
    • pp.270-276
    • /
    • 2008
  • $TiO_2$의 가장 큰 특징은 광촉매적 특성을 들 수 있으나 순수한 $TiO_2$는 자외선 영역에서만 활성을 보이는 단점이 있다. 단점을 보완하고자 본 연구에서는 초고온, 고활성을 이용한 열플라즈마 공정으로 질소가 도핑된 $TiO_2$를 합성하여 $TiO_2$의 광촉매적 특성을 높이고자 하였다. 직류 플라즈마 제트를 이용하여 비금속이온인 질소와 반응 가스인 산소를 $TiCl_4$와 함께 플라즈마 반응기 안에서 반응시켜 질소가 도핑된 $TiO_2$ 나노 분말을 합성하였다. 합성 조건으로 질소의 유량을 변화하였다. 합성 변수에 따른 입자의 상조성, 크기를 분석하였고 아세트알데히드와 곰팡이를 광분해하는 실험을 통해 광촉매 활성을 살펴보았다. 한편 $TiO_2$의 분말 상태와 코팅된 상태의 광촉매 특성을 비교하고자 합성한 분말의 스핀 코팅과 PLD (Pulsed Laser Deposition)을 통해 $TiO_2$를 코팅하였다. 아세트알데히드 분해 실험의 결과 질소가 도핑된 $TiO_2$ 분말의 경우가 순수한 $TiO_2$ 분말에 비해 가시영역에서의 광촉매 활성이 두 배 이상 뛰어난 것을 확인하였으며, 곰팡이 분해 실험 결과 역시 질소가 도핑된 $TiO_2$ 분말에 곰팡이가 분해되는 것을 확인하였다. 분말과 필름을 제조하여 메틸렌블루 광분해 실험한 결과 분말의 경우 100% $TiO_2$입자가 메틸렌블루 분해에 이용되며, 반면 스핀 코팅의 경우 바인더의 함량 때문에 20~30%의 $TiO_2$만이 분해에 이용되기 때문에, 분말의 경우 초기 30 mL 메틸렌블루를 한번에 분해할 수 있었다.