• 제목/요약/키워드: pulsed corona

검색결과 42건 처리시간 0.019초

수중 펄스코로나 방전에 의한 메틸오렌지 제거 특성 (Degradation of methyl orange by pulsed corona discharges in aqueous solution)

  • 이현돈;김종오;김형갑;정재우
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.69-76
    • /
    • 2012
  • A laboratory experiment on methyl orange degradation in pulsed corona discharges was carried out. Effects of operating parameters such as applied voltage, pH, conductivity and initial concentration on methyl orange degradation were investigated. The pulsed corona discharges decreased the pH of solution and increased conductivity, probably due to products generated from methyl orange degradation by corona discharges. The decrease of initial pH enhanced the methyl orange degradation. The methyl orange degradation was fastest in $100{\mu}S/cm$ conductivity solution, followed by 50 and $200{\mu}S/cm$, indicating that $100{\mu}S/cm$ is the most favorable in the aspect of radical generation among the experimented conditions. The methyl orange of initial concentration from 20 to 60mg/L was effectively degraded in pulsed corona discharges. The lower initial concentration of methyl orange, the faster degradation was observed.

상온 펄스 코로나 방전 공정에 의한 NO 제거 효율 (NO Removal Efficiency by Pulsed Corona Discharge Process at Room Temperature)

  • 김동주;박정환;김교선
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.337-344
    • /
    • 2002
  • In this study, we analyzed the NO removal efficiency by the pulsed corona discharge process and investigated the effects of several process variables such as initial concentrations of NO, $H_2O$, and NH$_3$, applied voltage, pulse frequency, diameter of the discharge electrode, and residence time. The removal efficiency of NO increased by the addition of $H_2O$ or NH$_3$, but the changes of initial NH$_3$ and $H_2O$ concentrations did not affect the removal efficiency of NO significantly. With the increases of the applied voltage or the residence time, the removal efficiency of NO increased. In addition, with the increases of the pulse frequency of applied voltage, or the diameter of the discharge electrode, the removal efficiency of NO increased. The experimental results can be used as a basis to design the pulsed corona discharge process to remove NO$_{x}$, SO$_{x}$ and VOCs.OCs.

Transesterification of Vegetable Oils in Pulsed-Corona Plasma Discharge Process

  • Hyun, Young-Jin;Mok, Young-Sun;Jang, Doo-Il
    • 한국응용과학기술학회지
    • /
    • 제29권1호
    • /
    • pp.81-87
    • /
    • 2012
  • The biodiesel production characteristics in a pulsed-corona plasma reactor has been investigated through parametric tests. Transesterification of rapeseed oil together with camelina oil was done with the change of such variables as voltage of power, molar ratio, KOH catalyst and temperature. The energetic electrons emitted from pulsed-corona plasma has contributed to the enhancement of yield on rapeseed oil in short time (15 min). The higher yield on camelina oil was observed in 5 min. The optimal parameters were shown as the voltage of 23 kV, the molar ratio of 5/1, the content of KOH catalyst of 0.6 wt% and the temperature of $28^{\circ}C$ under the rotating rate of spark gap of 900 rpm.

펄스 코로나 농약산포장치의 분무대전 특성 (Pulsed Corona Charging Characteristics of Aqueous Pesticide Spray)

  • 문재덕;이운태;배창환;권남열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.388-394
    • /
    • 2003
  • Many toxic pesticides as aqueous-base sprays are dispensed for protection of food crops from pests into farm fields. When dispensed with conventional nozzles, a large portion of the spray is often lost by airborne drifts of droplets away and lack of deposition onto the plants due to rapid gravitational settling of droplets to the soil beneath. And target deposition efficiencies poorer than 20% are often encountered in agricultural pesticides. An electrostatic spraying technology offers a very favorable means to increasing pesticides droplets deposition onto biological surfaces of living crops. In this paper a corona type spray nozzle, utilizing a set of corona charging devices and a pulsed droplet-charging voltage applied, has been proposed and tested its potential experimentally. As a result, it exhibits a large current deposition of aqueous pesticide sprays on the sensing target, which, however, promise to be as one of the effective electrostatic spraying nozzle.

$N_{2}/O_{2}$ 혼합가스에서 펄스코로나 방전을 이용한 NOx 제거 모델링에 관한 연구 (DeNOx modeling in $N_{2}/O_{2}$ gas by pulsed corona discharge)

  • 박광서;이형상;전배혁;신현호;윤웅섭;전광민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.117-128
    • /
    • 1999
  • The removal of nitrogen oxides(NOx) from $N_{2}/O_{2}$ gas using a pulsed corona discharge was investigated as a function of the reduced electric field(E/N) and the energy density(J/L). A kinetic model was developed to characterize the chemical reactions taking place in a pulsed corona discharge reactor. The model calculates the fractional concentrations of radical species at each pulse-on period and utilizes the radicals to remove NOx for the subsequent pulse-off period. Electron collision reaction data are calculated using ELENDIF program to solve Boltzmann equation for electron energy distribution function, and the subsequent chemical reactions are calculated using CHEMKIN-II program to solve stiff ODE(ordinary differential equation) problems for species concentrations. The corona discharge energy per pulse and the time-space averaged E/N were obtained by fitting the model to experimental data. The model calculation shows good agreement with the experimental data, and predicts the formation of other species such as $NO_{2}$, $O_{3}$ and $N_{2}O$.

  • PDF

펄스 코로나 방전 공정에서 탈질, 탈황 효율의 실험적 분석 (Experimental Analysis on the Desulfurizarion and Denitrification Efficiencies in Pulsed Corona Discharge Process)

  • 김성민;김교선
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.181-186
    • /
    • 2003
  • In this study, we analyzed $NO_x$ and $SO_x$ removal efficiencies by a pulsed corona discharge process and investigated the effect of several process variables. The removal efficiencies of NO and $SO_2$ were measured changing the process variables of initial concentrations of NO, $H_2O$, and $NH_3$, $SO_2$, applied voltage, pulse frequency and residence time. As the applied voltage or the frequency of applied voltage or the residence time increases, the NO and $SO_2$ removal efficiencies increase. The NO and $SO_2$ removal efficiencies also increase by the addition of $O_2$ or $H_2O$, or by using the large diameter of the discharge electrode. The experimental results can be used as a basis to design the pulsed corona discharge process to remove $NO_x$, $SO_x$ and VOCs.

  • PDF

펄스 corona 배향된 비선형광학 고분자박막의 제2 고조파발생 (Second harmonic generation of pulsed corona - poled nonlinear optical polymer films)

  • 김준수;이종하;이황운;김상열;원영희
    • 한국광학회지
    • /
    • 제13권4호
    • /
    • pp.356-362
    • /
    • 2002
  • 비선형광학(NLO) 곁가지형 고분자계 N-(4-nitrophenul)-(L)-prolinol-poly (p-phenylene terephthalates)로 제작된 박막의 분자 배향거동을 제2 고조파발생(SHG)의 비선형광응답을 사용하여 연구하였다. 새로운 펄스 corona 배향 방법으로 NLO 발색단과 고분자 줄기를 비중심대칭 구조로 배향시켜 SHG 신호를 발생시켰다. 유리전이온도 70$^{\circ}C$를 중심으로 25$^{\circ}C$에서 80$^{\circ}C$까지 온도영역에서 반복율을 0.5 ㎑에서 10 ㎑까지 변화시키면서 인가한 펄스 고압으로 corona 배향한 결과로 곁가지 발색단과 고분자 주사슬이 스스로 재 정렬하여 형성한 구역구조를 원자간력 현미경(AFM)으로 관측하였다. 펄스 corona 전압 인가로 NLO 발색단 배향도가 증가되고, 동시에 고분자박막의 가시적손상을 획기적으로 줄이면서 SHG 신호가 증대되었으며 배향 후 이완거동도 개선되었다. 이 새로운 펄스 corona 배향 실험으로 NLO 발색단 및 고분자 주사슬이 배향과정에서 비등방으로 재배열하는 현상을 in situ로 입증할 수 있었다.

DeSOx/DeNOx 효율 개선을 위한 펄스 코로나 방전하에서 기체미립자 전환반응의 적용 (Application of Gas to Particle Conversion Reaction to increase the DeSOx/DeNOx Efficiency under Pulsed Corona Discharge)

  • 최유리;김동주;김교선
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.249-258
    • /
    • 1998
  • In this paper, we investigated the post-combustion removal of nitrogen oxide($NO_x$) and sulfur oxide($SO_x$) which is based on the gas to particle conversion process by the pulsed corona discharge. Under normal pressure, the pulsed corona discharge produces the energetic free electrons which dissociate gas molecules to form the active radicals. These radicals cause the chemical reactions that convert $SO_x$ and $NO_x$ into acid mists and these mists react with $NH_3$ to form solid particles. Those particles can be removed from the gas stream by conventional devices such as electrostatic precipitator or bag filter. The reactor geometry was coaxial with an inner wire discharge electrode and an outer ground electrode wrapped on a glass tube. The simulated flue gas with $SO_x$ and $NO_x$ was used in the experiment. The corona discharge reactor was more efficient in removing $SO_x$ and $NO_x$ by adding $NH_3$ and $H_2O$ in the gas stream. We also measured the removal efficiency of $SO_x$ and $NO_x$ in a cylinder type corona discharge reactor and obtained more than 90 % of removal efficiency in these experimental conditions. The effects of process variables such as the inlet concentrations of $SO_x$, $NH_3$ and $H_2O$, residence time, pulse frequencies and applied voltages were investigated.

  • PDF

펄스 코로나 방전 반응기를 이용한 NOX 제거 효율 및 입자 성장 분석 (Analysis on NOX Removal Efficiencies and Particle Growth Using Pulsed Corona Discharge Reactor)

  • 박정환;김동주;김교선
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.155-161
    • /
    • 2001
  • In this study, we analyzed the $NO_X$ removal efficiency and particle size distribution by the pulsed corona discharge process and investigated the effect of several process variables. The NO removal efficiencies and the particle characteristics were measured and analyzed as the function of initial concentrations of NO, $H_2O$, and $NH_3$, applied voltage, pulse frequency and residence time. As the frequency of applied voltage increases, or as the applied voltage increases or as the residence time increases, the NO removal efficiency increases. The change of initial $NH_3$ and $H_2O$ concentrations do not affect the NO removal efficiency significantly. The particle concentration and size increases with the increases of initial NO concentration, residence time and applied voltage.

  • PDF

펄스 코로나 반응기에서 방전극의 배열에 따른 탈질율 연구 (A Study on the NOx Removal Rate by Arrangement of Discharge Electrode in Pulsed Corona Discharge Reactor)

  • 최민;박소진;위영호
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.315-323
    • /
    • 2003
  • The goal of this study if the optimization of discharge electrode for pulsed corona discharge reactor located in thermal power plant. For this purpose, we have performed experiments of NO$_{x}$ removal rate by exchange of discharge electrode diameter and arrangement of discharge electrode in the non -thermal plasma reaction facility using a ethylene as additive. If the diameter and numbers of discharge electrode were larger, the NO$_{x}$ removal rate was higher. From these results, if we optimized the shape and installed numbers of discharge electrode at the pilot plant, we could increase the NO$_{x}$ removal rate with less amount of additive than current amount.mount.