• Title/Summary/Keyword: pulsed Nd:YAG laser

Search Result 276, Processing Time 0.022 seconds

Wavelength tuning at a pulsed Ti:sapphire laser with a birefringent filter (복굴절 필터를 사용한 펄스동작 Ti:sapphire 레이저의 파장 가변특성)

  • 김병태;이형권
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.6
    • /
    • pp.450-455
    • /
    • 1997
  • A pulsed Ti:sapphire laser with a Z-folded cavity, which was pumped by a freqeuncy-doubled Nd:YAG laser, was developed. It shows 120 nm wavelength tuning range from 740 nm to 860 nm with 90 nm FWHM under a pumping energy of 3 mJ with 18% output coupler. Using a birefringent filter, the effective efficiency was improved about 10 times compare to without a birefringent filter. The output energy obtained was $\365mu$Jwith 4 nm FWHM. And the wavelength tuning range was broadened to about 160 nm within an output energy fluctuation of $\pm$10%.

  • PDF

Selective nucleation of copper on fluorocarbon-resin surface by Nd:YAG laser-induced chemical reaction (레이저 유도 화학반응을 이용한 fluorocarbon 수지표면 위의 선택적 구리핵의 형성)

  • Lee, Hong-Kyu;Lee, Kyoung-Cheol;Ahn, Min-Young;Lee, Cheon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1535-1537
    • /
    • 1999
  • Photochemical defluorination and substitution of fluorocarbon-resin surfaces using a pulsed Nd:YAG laser(266 nm) and copper-sulfate$(CuSO_4)$ aqueous solution were discussed. Interface of copper nuclei and fluorocabon-resin was chemically bonded through oxygen which was photodissociated from water in copper-sulfate aqueous solution under the laser irradiation. The reaction mechanism for chemical surface modification is discussed on the basis of x-ray photoelectron spectroscopy and atomic force microscope analyses.

  • PDF

Effect of a Pulsed Nd:YAG laser irradiation on human gingival tissues (파동형 Nd:YAG 레이저조사가 인체 치은조직에 미치는 영향)

  • Kang, Kyung-Dong;Kim, Chun-Suk;Kim, Hyung-Soo;Kim, Hyun-Seop;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.4
    • /
    • pp.989-1002
    • /
    • 1996
  • The purpose of this study was to determine the effect of a pulsed Nd:YAG laser irradiation on human gingival tissues. The patients, who were planned to be treated by clinical crown lengthening procedure and gingivectomy, were selected. All the patients received oral hygiene instruction, scaling and root planing at preoperation. The crest of gingival tissue on upper and lower anterior teeth was irradiated by a pulsed Nd:YAG laser(El. EN. EN060, Italy) with a fiber optic of 300 m in contact mode for 20 seconds. Gingival tissues were divided into 4 groups according to the laser power of 1.0W(10Hz, 100mJ), 2.0W(20Hz, 100mJ), 3.0W(30Hz, 100mJ) and 4.0W(40Hz, 100mJ). Immediately after the laser irradiation, the specimens were excised, fixed 10% neutral formalin, sectioned $4-6{\mu}m$ thick, stained by Hematoxylin-Eosin and Periodic Acid Schiff stain and observed under light microscope. The removed tissue depth and the coagulated layer depth due to a laser irradiation by a laser irradiation were measured on the microphotographs. The difference of measurements according to the different laser power was statistical1y analyzed by Kruskal Wallis Test with SAS program. The results were as follows : 1. In histologic findings of irradiated gingival tissues; a. In the irradiated gingival specimen with 1.0W laser power, some vesicles were observed in limited superficial layer of gingival epithelium. b. In the irradiated gingival specimen with 2.0W and 3.0W laser power, the epithelium was almost removed except for the traces of viable basal cell remnants at ret peg, and coagulation necrosis related with the thermal effect of laser was noted. c. In the irradiated gingival specimen with 4.0W laser power, complete removal of epithelium, partial removal of underlying connective tissue, and the coagulation necrosis of subjacent gingival tissue were shown. 2. The removed tissue depth was deeper in the irradiated specimens with higher power. There was a statistical significance in the difference of removed tissue depth between 1.0W group ($44.54{\pm}6.99um$) and 3.0W group ($99.75{\pm}6.64{\mu}m$), and between 1.0W group($44.54{\pm}6.99{\mu}m$) and 4.0W group($111.36{\pm}4.50{\mu}m$), and between 2.0W group($98.01{\pm}4.53{\mu}m$) and 4.0W group($111.36{\pm}4.50{\mu}m$)(P<0.05). 3. The coagulated layer depth was deeper in the irradiated specimens with higher power. There was a statistical significance in the difference of coagulated layer depth between 1.0W group($31.82{\pm}8.99{\mu}m$) and 3.0W group($55.99{\pm}20.94{\mu}m$), and between 1.0W group($31.82{\pm}8.99{\mu}m$) and 4.0W group($83.68{\pm}10.34{\mu}m$)(P<0.05). From this study, the results demonstrated that the effects of a pulsed Nd:YAG laser irradiation on gingival tissues seemed to depend on the laser power and that the irradiation with high power could be harmful to adjacent healthy tissue.

  • PDF

Enhancement of Pulsed-Laser Ablation by Phase Explosion of Liquid (액체의 상폭발 과정에 의한 펄스 레이저 용발률의 증진)

  • Kim, Dong-Sik;Lee, Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1483-1491
    • /
    • 2001
  • Enhancement of pulsed-laser ablation by an artificially deposited liquid film is presented. Measurements of ablation rate, ablation threshold, and surface topography arc performed. Correlation between material ablation and photoacoustic effect is examined by the optical beam deflection method. The dependence of ablation rate on liquid-film thickness and chemical composition is also examined. The results indicate that photomechanical effect in the phase explosion of liquid is responsible for the enhanced ablation. The low critical temperature of liquid induces explosive vaporization with localized photoacoustic excitation in the superheat limit and increases the ablation efficiency. Experiments were carried out utilizing a Q-swiched Nd:YAG laser at near-threshold laser fluences with negligible plasma effect (up to ∼100 MW/cm$^2$).

Correlation Between Deposition Parameters and Photoluminescence of ZnO Semiconducting Thin Films by Pulsed laser Deposition (PLD증착 변수에 따른 II-VI족 화합물 ZnO 반도체 박막의 발광 특성 연구)

  • 배상혁;윤일구;서대식;명재민;이상렬
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.3
    • /
    • pp.246-250
    • /
    • 2001
  • ZnO thin films for light emission device have been deposited on sapphire and silicon substrates by pulsed laser deposition technique(PLD). A Nd:YAG laser was used with the wavelength of355 nm. In order to investigate the emission properties of ZnO thin films, Pl measurements with an Ar ion laser a light source using an excitation wavelength of 351 nm and a power of 100 mW are used. All spectra were taken at room temperature by using a grating spectrometer and a photomultiplier detector. ZnO exhibited Pl bands centers around 390, 510 and 640 nm, labeled near ultra-violet(UV), green and orange bands. Structural properties of ZnO thin films are analyzed with X-ray diffraction(XRD).

  • PDF

Light emission properties of ZnO thin films grown by pulsed laser deposition (펄스 레이저 증착법으로 제작한 ZnO 박막의 발광 특성)

  • 배상혁;이상렬
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.539-542
    • /
    • 2000
  • ZnO thin films for light emission device have been deposited on sapphire and silicon substrates by pulsed laser deposition technique(PLD). A Nd:YAG laser was used with the wavelength of 355 nm. In order to investigate the emission properties of ZnO thin films, PL measurements with an Ar ion laser as a light source using an excitation wavelength of 351 nm and a power of 100 mW are used. All spectra were taken at room temperature by using a grating spectrometer and a photomultiplier detector. ZnO exhibited PL bands centered around 390, 510 and 640 nm, labeled near ultra-violet (UV), green and orange bands. Structural properties of ZnO thin films are analized with X-ray diffraction (XRD).

  • PDF

Histological Changes of the Wound in the Tongue Mucosa of White Rats by Pulsed Nd:YAG Laser - A Comparative Experiment with the Scalpel Incision (Pulsed Nd:YAG 레이저로 유발된 백서 설점막 창상의 조직학적 변화-수술칼에 의해 형성된 창상과의 비교 실험)

  • 박준상;박미희;박봉수
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.125-135
    • /
    • 1997
  • The Author examined the clinical and histological changes on the dorsal tongue mucosa of the adult rats after lasing by pulsed Nd:YAG laser and incising with scalpel. The dorsal tongue was lased through 320$\mu\textrm{m}$optic fiber moving 2.5mm/second to make linear incision 5mm. The five conditions of lasing were three application with 1.0W, 1.75W, 3.0W and 3.0W under saline cooling, and single application with 3.0W at 20Hz. With scalpel, linear incisions through the surface epithelium were performed to 5mm in length. After observing the clinical changes of the incised wounds, the animals were sacrified and the tissues were excised to make the tissue specimens. The stained microscopic tissue slide were observed histologically under the microscope. The following results were obtained : 1. While incision with scalpel causes severe bleeding, lasing does not cause bleeding. 2. In three applications with 1.75W and 20Hz, tissue ablation was limited to areas contacted with optic fiber. 3. In three applications with 3.0W and 20Hz, deep incised wound, extensive destruction of the adjacent epithelium and charring were observed. 4. In three applications with 3.0W and 20Hz under saline cooling, tissue ablation was limite to the superficial mucosa and charring was not observed. 5. In single application with 3.0W and 20Hz, the shape of the incised wound was similar to that of the scalpel incision.

  • PDF

Magnetic Properties of SmCo Thin Films Grown by Using a Nd-YAG Pulsed Laser Ablation Method (Nd-YAG Pulsed Laser Ablation법으로 제작한 SmCo계 박막의 자기특성)

  • 김상원;양충진
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 2000
  • SmCo films were deposited on Si(100) substrate by a Nd-YAG pulsed laser ablation of the targets of Sm$\_$100-x/Co$\_$x/ (73$\leq$x$\leq$93) at the substrate temperature of 600∼700$\^{C}$ and the laser beam energy density of Q switching mode or fixed Q mode. The magnetic properties of the films obtained from the Q switching mode exhibited a 4 $\pi$ Ms of 5200∼7700 Gauss, iHc of 190-250 Oe, and 4$\pi$M$\_$r//4$\pi$M$\_$s/ of 0.4∼0.74, respectively, while the fixed Q mode gave the magnetic properties of corresponding films of a 4$\pi$M$\_$r//4$\pi$M$\_$s/ = 0.32∼0.91 and iHc of 430-6290 Oe, respectively. The fixed Q mode gave the better magnetic properties of the SmCo films which seems to be due to a formation of magnetically hard minor phases in droplet of Sm-rich intermetallics. However, the resultant rough surface of the SmCo films is a problem to be solved by a continued study.

  • PDF

Characteristics of Laser-Guided DC Discharge by Nd: YAG Laser at Low Pressure

  • Lee, Dong-Hoon;Kim, Hee-Je
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.3
    • /
    • pp.316-321
    • /
    • 1998
  • In recent years, concern has been raised about the technique of controlling electrical breakdown by using laser in many fields. Especially, laser has attracted much attention in the Electro-Discharge Macining(EDM) because of its many merits. Therefore, this research has been performed to obtain fundamental data relevant to discharge processing by using a pulsed Nd:YAG laser. The experiments of laser-guided dc discharge by laser radiation have been carried out at low air pressure ranging from 0.2 to 20 torr. The minimum laser-guided dc discharge voltage V\ulcorner at the given pressures P and distances D between an anode and a cathode was measured. It is found that the minimum laser-guided dc discharge voltage is much lower than the natural discharge voltage V\ulcorner\ulcorner, and the values of V\ulcorner and V\ulcorner as a function of P.D has a similar tendency. The laser output energy Eout decreases with input pulse duration tp increasing, and the more the value of tp increases, the higher that of V\ulcorner is obtained because the number of photons during the discharge time N decreases with t\ulcorner increasing. There is the time lag frequently when the discharge by laser radiation is misguided under the condition of the applied voltage less than V_G.min.

  • PDF

An Operational Characteristic of a Trigger-Gap Switch induced by Pulsed Nd:YAG Laser (펄스형 Nd:YAG레이저에 의한 트리거 갭 스위치의 동작특성)

  • Nahm, G.H.;Chung, H.J.;Lee, D.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1693-1695
    • /
    • 1998
  • 콘덴서에 고압으로 축적된 에너지를 부하로 전달해주는 스위칭기술은 고전압 펄스 파워 분야에서 아주 필수적이다. 이러한 관점에서 볼 때, 트리거 갭 스위치는 흔히 연구실에서 용이하게 사용할 수 있고, 갭 간격을 조정함에 의해 방전전압을 가변할 수 있는 장점이 있다. 그러나, 트리거 갭 스위치는 트리거 방전없이 생기는 자가방전이 발생하거나 트리거 방전이 생겨도 주방전이 일어나지 않는 경우가 있다. 본 연구에서는 이러한 일반 트리거 갭의 단점을 보완하고 확실하게 동작하는 갭 스위치의 제작에 필요한 데이터 확보를 위해 Nd:YAG 레이저를 트리거 갭 스위치 음극에 조사해 전극사이의 거리 g와 압력에 따른 최소트리거전압 $V_{T.min}$의 특성을 파악하였다.

  • PDF