• 제목/요약/키워드: pulsed Nd:YAG laser

검색결과 276건 처리시간 0.026초

Nd:YAG-PLD법에 의해 제작된 ZnO:AI 박막의 구조적, 광학적, 전기적 특성 (Structural, Optical and Electrical Properties of AI Doped ZnO Thin Films Prepared by Nd:YAG-PLD Technology)

  • 노임준;임재성;이천;신백균
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1596-1601
    • /
    • 2007
  • Aluminum doped zinc oxide (AZO) thin films were deposited on coming glass substrates using an Nd:YAG pulsed laser deposition technology. The AZO thin films were deposited with various growth conditions such as the substrate temperature and oxygen partial pressure. In this work, we used various measurement technologies in order to investigate the electrical, structural, and optical properties of the AZO thin films. Among the AZO thin films, the one prepared at the substrate temperature of $300^{\circ}C$ and oxygen partial pressure of 5 mTorr showed the best properties of an electrical resistivity of $4.63{\times}10^{-4}{\Omega}{\cdot}cm$, a carrier concentration of $9.25{\times}10^{20}cm^{-3}$, and a carrier mobility of $31.33cm^2/V{\cdot}s$. All the AZO thin films showed an high average optical transmittance over 90 % in visible region.

Nd : YAG, HO : YAG, Er : YAG 레이저 조사에 의한 상아질의 물리적 변형 및 절제(切除)역치에 관한 연구 (PHYSICAL MODIFICATION AND ABLATION THRESHOLDS OF DENTIN INDUCED BY ND : YAG, HO : YAG, AND ER : YAG LASERS)

  • 이상호
    • 대한소아치과학회지
    • /
    • 제23권4호
    • /
    • pp.954-967
    • /
    • 1996
  • Laser application to modify healthy permanent dentin to improve microhardness and caries resistence has been previously reported but the physical modification and ablation thresholds of carious and sclerotic dentin has yet to be identified. This study determined the energy density required by modify (physical modification threshold, PMT) and remove (ablation threshold, AT) infected carious, affected and selerotic dentin compared to healthy permanent dentin. $1{\pm}0.25mm$ thick dentin sections(n=272) from extracted human teeth were used. Smear layer was removed 0.5M EDTA for 2 minutes. Utilizing three pulsed fiberopitc delivered contact lasers with different emission wavelengths($1.06{\mu}m$=Nd : YAG, $2.10{\mu}m$=Ho : YAG and $2.94{\mu}mEr$ : YAG). The energy density($J/cm^2$) was incrementally increased and the resulting tissue interaction classified on a scale from 0-6. A minimum of 5 repetitions/energy density were completed. Light microscopy(10-25X) was used to verify the physical modification(scale=3) and ablation thresholds(scale=4) of the various forms of dentin and the data were analyzed by logistic regression at the 95 % confidence interval. PMT and AT by the laser and the dentin types were: PMT and AT was lower in infected dentin than in sound dentin for all lasers. PMT and AT induced by Nd : YAG>Ho : YAG>Er : YAG for all forms of dentin. Microhardness was increased in sound dentin at PMT. Morphology of crater examined by light microscopy showed Nd : YAG was safe and effective for removing carious dentin and Er: YAG was effective for removing sound dentin. The PMT and AT for YAG lasers are different as a function of dentin type which may be utilized for selective modification and removal of dentin.

  • PDF

신장이식 환자에 있어서 Cyclosporin-A에 의한 치은비대의 치험례 (A Case Report on the Treatment of Cyclosporin-A Induced Gingival Enlargement in Renal Transplant Patient)

  • 장성용
    • Journal of Oral Medicine and Pain
    • /
    • 제23권2호
    • /
    • pp.119-125
    • /
    • 1998
  • The authors treated a 58-year old female patient who had come to the Department of Oral Medicine, KNUH due to the chief complaints of gingival enlargement and bleeding on the upper and lower jaw. The lesions were diagnosed as cyclosporin-A induced gingival enlargement by patient's history and clinical examination. The patient was treated with gingivectomy using pulsed Nd:YAG laser. After gingivectomy the wound was compressed with 0.1% chlorhexidine-soaked gauze to prevent relapse of the lesion. Good healing process was observed and there were no recurrences until 3-month follow-up visit. From the results of this clinical trial it was suggested that a pulsed Nd:YAG laser gingivectomy would be helpful for the treatment of cyclosporin-A induced gingival enlargement in renal transplant patients.

  • PDF

The effects of EDTA and pulsed Nd:YAG laser on apical leakage of canal obturation

  • Kwon, Jin-Soo;Lee, Hee-Joo;Hur, Bock
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.563.1-563
    • /
    • 2001
  • The purpose of this study was to evaluate the effects of EDTA and pulsed Nd:YAG laser on apical of canal obturation. Forty-eight single-rooted teeth were used in thes study. The teeth were instrumented up to a size 40 K-file and irrigated with 2.5% NaOCl between each file size. And the teeth were divided into 4 groups. In group A, the root canals were irrigated with a final flush of 5ml 2.5% NaOCl as a control group.(omitted)

  • PDF

A Design and Implement of the Medical Nd:YAG Laser Firmware under in ZCC method

  • Kim, Whi-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.40.3-40
    • /
    • 2001
  • The pulsed Nd:YAG laser is the most commonly used type of solid-state laser in many fields. In material processing and medical treatment, the power density control of a laser beam Considered to be significant, which depends on the flashlamp current pulse width and pulse repetition rate. For general laser power supply to control the laser power density, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is applied to a switching element in the secondary of the transformer. So power supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition rate, charged energy of energy-storage capacitor bank is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this study, we have ...

  • PDF

PLD로 제작한 Si 박막에서의 광학적 특성분석 (Optical properties of Si thin films grown by PLD)

  • 배상혁;이상렬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.532-534
    • /
    • 2000
  • Si thin films on p-type (100) Si substrate have been fabricated by pulsed laser deposition technique using a Nd:YAG laser. The pressure of the environmental gas during deposition was varied from 1 to 3 Torr. After deposition, Si thin film has been annealed again at nitrogen ambient. Strong violet-indigo photoluminescence have been observed from Si thin film annealed in nitrogen ambient gas. As increasing environmental gas pressure, weak green and red emissions from annealed Si thin films also observed by photoluminescence.

  • PDF

Pulsed Nd:YAG 레이저 조사와 불소화합물 도포가 치아 내산성에 미치는 영향 (Effects of Pulsed Nd:YAG Laser Irradiation and Fluoride Compound Applicatin on Acid Resistance of Bovine Teeth)

  • An-Hee Lee;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • 제20권2호
    • /
    • pp.429-447
    • /
    • 1995
  • This study was designed to determine the most effective concentration of fluoride and levels of laser irradiation for the remineralization of decayed teeth. After irradiation with a pulsed Nd:YAG laser and the topical application of fluoride, phosphate and fluoride concentration in enamel were measured. And then the changes on surface enamel using an scanning electron microscope were observed. Samples by extraction healthy, permanent, mandibular bovine teeth with no caries were obtained. Among them 371 healthy samples were selected and artificial carious lesions were made. 20 samples were assigned to each experimental group. After irradiation with a pulsed Nd:YAG laser with total energy densities of 10J/$\textrm{cm}^2$, 20J/$\textrm{cm}^2$ for each group. On the teeth, 2% NaF, 1.9% NH4F, 1.6% TiF4 Elmex gel(amine fluoride) and 1.23% APF gel were applied. After pH circulatory procedures, concentrations of fluoride with and Ionalyzer (Orion Research, Model 901, USA) and phosphates with an Uv/V is spectrophotometer (Uvikon 860, Kontrom Co, Switzerland) were measured. By etching the teeth in layers and measuring fluoride concentrations, a profile of fluoride penetration according to depth could be developed. And also the changes on the surface of the enamel using an electron scanning microscope were observed. The comparative analysis yielded the following results : 1. Phosphate concentration was low in all groups compared with the control group except for teeth treated Elmex gel, irradiated with 10J/$\textrm{cm}^2$ and 30J/$\textrm{cm}^2$ energy densities. Teeth treated with APF gel and 30J/$\textrm{cm}^2$ irradiation gad the lowest phosphate concentration. 2. Among all groups, fluoride concentrations in tooth enamel were highest in APF gel and NaF groups irradiated at 30J/$\textrm{cm}^2$. The APF gel group had the highest fluoride concentrations across all energy densities. 3. In the APF gel group, and the NaF group, the greater the energy density of the laser, the higher the fluoride concentrations in the enamel. 4. In all groups, the concentration of fluoride in the enamel by depth tended to decrease with depth. 5. Under the scanning electron microscope, under the condition of irradiation with 20J/$\textrm{cm}^2$, enamel crack was detected for the first time. In the NH4F group, spherical deposits were found on the surface of the enamel, and in the TiF4 group the surface of enamel was covered with an irregular, thin membranous mass in places. In the APF gel and NaF groups irradiated with 10J/$\textrm{cm}^2$, spherical and irregular particles covered the teeth. When these groups were irradiated at 20J/cm2, they were covered with amorphous crystals. These results suggest that one could obtain more effective anticariogenic effects without damage to teeth when less than 20J/$\textrm{cm}^2$ energy densities and APF gel are used.

  • PDF

Nd:YAG Laser를 위한 포켓셀 Q-스위치특성 연구 (A study on the characteristic of Pockel cell Q-switch for Nd:YAG laser)

  • 김휘영
    • 디지털콘텐츠학회 논문지
    • /
    • 제10권2호
    • /
    • pp.199-207
    • /
    • 2009
  • Q-스위칭은 셔터나 다른 광학소자를 레이저 광 공진기 내에 넣어 광이 공진기 내에서 발진하는데 손실을 유발하고, 충분한 반전분포가 활성 매질 내에서 생성되면 순간적으로 셔터를 열어 공진기 내에 축적된 에너지가 매우 강한 빛으로 방출되게 하는 것이다. 이와 같이 Q-스위칭은 레이저 공진기의 Q--factor를 감소시켰다가 갑자기 증가시키는 것이다. 레이저 Q-스위칭의 방법에는 mechanical switching 방법, electro-optic switching 방법, switching by saturable absorber 방법, acousto-optic switching 방법 등 크게 4가지가 쓰이고 있다. 이들 중 전기광학적인 효과에 의한 전기적인 전환은 짧은 펄스폭의 Q-스위칭 펄스를 생성할 수 있기 때문에 널리 사용되고 있다. 따라서, 전기광학효과의 특성을 가진 Pockel cell은 Q--switch로 사용하기 적합한 것으로 알려져 있다. 본 연구에서는 포켈스 셀 Q-스위치용 구동 장치를 스위칭 소자인 FET와 PIC 마이크로프로세서 및 펄스 트랜스로 설계, 제작하고, 펄스형 Nd:YAG 레이저 시스템에 적용하여 Q-스위치의 동작 특성을 조사, 연구하였다. 또한, 이 Q-스위치를 통하여 출력된 Nd:YAG 레이저 빔의 측정치를 이론적 계산에 의해 구해진 예상치와 비교하여 Q-스위칭 된 레이저 빔의 특성을 분석하였다.

  • PDF

Nd : YAG layer 조사가 치근면의 미세경도에 미치는 영향 (AN EFFECT OF Nd : VAG LASER IRRADIATION ON THE MICROHARDNESS OF ROOT SURFACE)

  • 안재현;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제25권3호
    • /
    • pp.614-622
    • /
    • 1995
  • Root caries is very frequently developed on exposed root surface after periodontal surgical treatment. In order to determine the anti-caries effect of Nd : YAG laser irradiation on periodontally exposed root surface, 40 mandibular molar teeth that had been extracted due to excessive periodontal destruction were used as the experimental teeth. All teeth were treated by the same procedure as conventional periodontal root treatment, ie thorough scaling, root planing and root conditioning with tetracycline HCl(100mg/ml, 5min.). Within middle one third of root, mesial half surface(20) or distal half surface(20) was randomly irradiated at various power of 1.0W, 2.0W, 3.0W and 4.0W for 60 seconds by non-contact(5mm) delivery of a pulsed Nd : YAG laser(EN.EL.EN060, Italy). The microhardness was measured by Vikers microhardness tester(Wilson, USA) at 2mm/second of jog speed under 100gm load. The difference of microhardness between irradiated side and non-irradiated side was statistically analyzed ANOVA and Duncan's method. Following results were obtained ; 1. The microhardness(Knoop hardness number) was significantly higher in laser irradiated surface than non-irradiated surface(p<0.05). 2. There was no significant difference in microhardness between experimental groups classified by different laser power(p>0.1). The results suggest that Nd : YAG laser irradiation on exposed root suface after periodontal therapy may inhibit the root caries development by enhancing surface microhardness.

  • PDF