• 제목/요약/키워드: pulse-wave sensor

검색결과 107건 처리시간 0.026초

3채널 맥파 측정 시스템 개발 (Development of 3-channel Pulse Wave Measurement System)

  • 김은근;허현;남기창;강희정;허영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1049-1050
    • /
    • 2008
  • It is difficult to measure the pulse wave in a short time because radial artery position and located depth are different depending on the person. In this paper, the pulse wave measurement system was developed using 3 channel piezoresistive sensor array to detect the most significant pulse wave. Augmentation Index(AI) and Heart Rate(HR) analysis are also available for predicting cardiovascular risks. The developed system is small and easy to use. And it is promising to be used as home healthcare device.

  • PDF

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권4호
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.

맥진기를 위한 동잡음 검출 시스템 (Moving Artefacts Detection System for a Pulse Diagnosis System)

  • 이전;우영재;전영주;이유정;김종열
    • 전자공학회논문지SC
    • /
    • 제45권5호
    • /
    • pp.21-27
    • /
    • 2008
  • 최근까지 맥진기에 대한 연구 및 상용화 요구가 지속되고 있으나 재현성 확보에 어려움을 겪고 있다. 이러한 재현성을 평가하는 중요 파라미터 중 하나는 맥압의 크기이다. 그러나 맥안은 동잡음에 매우 취약한 특성을 갖고 있다. 본 논문에서는 동잡음에 강한 맥진기 개발을 위하여 동잡음을 자동으로 검출하고 맥 측정구간에서 동잡음이 있는 구간을 제외함으로써 맥진기의 신뢰도를 높일 수 있는 방법을 제안하고자 한다. 동잡음 검출 시스템은 3축 가속도 센서, 근전도, 2축 기울기 센서로 구성하였으며, 시스템의 적합성을 평가하기 위하여 신장, 굴곡, 회전의 세 가지 동작에 대한 센서별 출력 신호 특성을 살펴보았다. 또한 맥진 센서를 맥진 위치에 적용한 상태에서 고주파 동잡음 및 저주파 동잡음을 유발하여 각 센서별 출력 신호 특성을 살펴보았다. 그 결과 저주파 동잡음은 근전도, 가속도 신호, 기울기 신호 순으로 동잡음 발생을 확인할 수 있었으며, 안정된 맥파 신호는 고주파 동잡음과 비슷하게 근 수축이 중단된 뒤 약 2초가 경과한 후에 얻어지는 것을 확인할 수 있었다. 이러한 사실을 근거로 동잡음 검출 규칙을 설정하였으며, 이를 구현한 동잡음 검출 알고리즘을 제안하였다.

영구자석과 홀소자를 이용한 무선 집게형 맥진기 특성 연구 (Property of Wireless Clip-type Pulsimeter by Using a Hall Device and a Permanent Magnet)

  • 윤우성;지종옥;이상석
    • 한국자기학회지
    • /
    • 제24권6호
    • /
    • pp.179-185
    • /
    • 2014
  • 영구자석과 홀소자가 구비된 집게형 맥진기의 USB 연결방식은 맥파의 측정과 분석함에 있어서 어떤 오작동이 없이 우수한 재현성을 갖고 있었다. 맥파 데이터를 송수신하는 USB 연결 방식 대신 이더넷(Ethernet) 무선 랜(LAN) 방식을 이용한 맥파 데이터의 무선 네트워킹 시스템의 특성을 집게형 맥진기에 적용하였다. 영구자석과 홀센서를 이용한 집게형 맥진기의 기존 USB 연결방식을 이더넷과 무선 LAN(Wi-Fi) 방식을 접목시켜, 맥파 데이터를 무선 통신으로 송수신하는 네트워킹 시스템을 구현하였다. 무선송수신 모니터링 시스템은 근거리에서도 안정된 자세로 맥진을 하게 되어 환자의 정확한 맥파 데이터를 전달받는데 많은 도움이 될 것으로 기대된다.

A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices

  • Lee, Sang-Suk;An, Myoung-Chone;Ahn, Sung-Hoon
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.132-136
    • /
    • 2009
  • This study investigated the radial pulse waveform obtained by a medical pulsimeter sensor. A pulse-sensing part array consisting of multiple Hall devices was located over a skin-contacting part with a hard magnetic material. The periodic movement of the magnetic material of the skin-contacting part affected the magnetic field in the pulse-sensing part array and was detected by multiple Hall devices. The analysis of a radial pulse waveform that is measured noninvasively by detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of oriental medical apparatus.

Design of Digital Systems for Web -based Pulse Diagnosis Database

  • Lee, Junyoung;Lee, Sungjae;Lee, Myoungho;Kim, Jeonghoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.181.4-181
    • /
    • 2001
  • In this study, we have developed the digital hardware system which performs signal processing necessary for the filtering to eliminate noises by inputting pulse wave signals from the sensor group. With a view to obtain clinically effective information, we analyzed structural elements of pulse waveform and, thus, conducted a systematic classification. What is more, this study has conducted researches in the web-based diagnosis data management system of pulse waveform as well as the method of transmitting the data of pulse waveform. In order to set the standard for the documents of the pulse ...

  • PDF

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.

PWM을 이용한 화재 감지를 위한 자외선 센서의 구동 방법 (Driving Method of Ultraviolet Sensor for Fire alarms using Pulse Width Modulation)

  • 임병현;고낙용;황종선;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집
    • /
    • pp.31-35
    • /
    • 2004
  • We propose driving method of Ultraviolet sensor for fire alarms using pulse width modulation that used to fire detector with sensor of private-use detectable light energy as ultraviolet in energy of electromagnetic-wave type radiate from flame, when combustible burn with contain carbon,. Ultraviolet sensor is UV Tron using gas multiplication effect to current discharge and photoelectric effect of metal. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research designed driving circuit with UV sensors and proposed method of false alarm reduced to resemble fire. the result propers the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

SS-OCT용 정현파 및 트리거 펄스 발생기 (Sine-wave and Trigger Pulse Generator for SS-OCT)

  • 엄진섭
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.398-403
    • /
    • 2015
  • In this paper, the sine-wave and trigger pulse generator with capability of frequency high-resolution and time-variable trigger edge has implemented. It fulfills well the requirements for SS-OCT with frequency resolution of 1 Hz, frequency stability of ${\leq}{\pm}0.03Hz$ and time-variable trigger edge. Through its performance test applied to the wavelength swept laser, 90 nm, sweeping range and 10mW average optical power were obtained. This showes that the realized generator can replace the commercial high cost and high performance signal generators employed by current SS-OCT systems.

4 채널의 Photo-plethysmogram 시스템 구현에 관한 연구(I) (Implementation of 4 Channel Photo-Plethysmogram System(I))

  • 김형태;한순천;김정국;허웅;박영배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.253-256
    • /
    • 2002
  • In this paper, we implement the volume pulse detection system which can quantitatively represent an artery elasticity. The system consists of transducer which has IRLED-photodiode detecter, temperature sensor, filters, preprocessing circuits, A/D converter, serial communication part and computer system. In order to presume the artery elasticity information we measure the volume pulse at four points and then evaluate the transition time, distance and the correlation coefficient of the pulse wave between the points. We test the system with 10 subjects during the week for basic experiment and obtain the data at four points. As the result of experiment, we can detect normalized volume pulse wave and evaluated parameter with effectively.

  • PDF