• Title/Summary/Keyword: pulse-like

Search Result 295, Processing Time 0.032 seconds

Study on Compass, Carpenter's square, The Beam of Balance and the Weight of balance[規矩權衡] in "Somun(素問).Maekyojeongmiron(脈要精微論)" ("소문(素問).맥요정미론(脈要精微論)"의 규구충권(規矩衡權)에 대한 연구)

  • Lee, Hye-Yeon;Kang, Jung-Soo
    • Journal of Korean Medical classics
    • /
    • v.23 no.1
    • /
    • pp.101-114
    • /
    • 2010
  • In the perspective of the correspondence of heaven and man[天人相應], people live through Gi of heaven and earth[天地之氣], and the human body which is a small universe[小宇宙] itself receives influence while sympathizing with the Gi and heaven[天氣]. So with unexpected incident of the Eum and Yang, four season[陰陽四時], ups and downs of warmth of cold and chilliness of warm[寒熱溫涼] differs, and the position of Gi of human[人氣] changes, regimen and application of acupuncture, and images[象] of the pulse changes. In "Maekyojeongmiron(脈要精微論)", ups and downs of Eum and Yang changes by four season[四時], and correspondence of ups and downs of pulse law is explained with compass, carpenter's square, the beam of balance and the weight of balance[規矩權衡]. Compass[規] is a measure of instrument that can draw a circle, like regulating the measure and differing the center of the circle and diameter and drawing a circle, compass is a image of Gi of Yang[陽氣] that was staying deep inside the body in winter stretching out by big fault[太過不及] of year and energy[元氣] of human in spring. Carpenter's square[矩] is a instrument that draws direction, which is a image of Gi of Yang flourishing in summer and when it gets highly flourished, again the Gi of Eum[陰氣] comes alive and falls. The beam of balance[衡] is a scale, like a scale that tilts at once when one side is slightly heavy, the beam of balance is a image Gi of yang that is fully flourished in summer and about to descent again, which is just about to fall but not going down yet. The weight of balance [權] is a image of gi of yang which as descent to the bottom and staying in the deepest place. compass, carpenter's square, the beam of balance and the weight of balance is not a direct pulse image[脈象], but standard image of pulse of pulse corresponding to the Gi of human[人氣] that changes by four season, and the explanation includes the pulse image of four season like the taut, full, floating, deeply gather[弦鉤浮營] of "Okgijinjangron(玉機眞藏論)" or taut, full, skip, float, deep [弦鉤代毛石] of "Pyeong-ingisangron(平人氣象論)". So with compass, carpenter's square, the beam of balance and the weight of balance, can judge is human correspond in Eum and Yang, four seasons, this is importantly used in examination of pulse[診脈] with existence and nonexistence, and prognosis of illness.

Study on Physiological Character of Stomach, and Correlation of Stomach Qi(胃氣) and True Visceral Pulse(眞藏脈) (위(胃)의 생리특성 및 위기(胃氣)와 진장맥(眞藏脈)과의 상관관계에 대한 연구)

  • Lee, Hye-Yeon;Kang, Jung-Soo
    • Journal of Korean Medical classics
    • /
    • v.24 no.4
    • /
    • pp.143-155
    • /
    • 2011
  • By examining the relationship between physiological character of stomach and true viscera pulse(眞臟脈) with "Huangdinejing(黃帝內經)", the study shows these fallowing results. Stomach is not only one of the six bowels(六腑), it represents them. It is called as yang brightness of foot(足陽明) because it has relation with function of earth among five phases(五行), great storage(倉廩) and root of five visceras and six bowels(五臟六腑), has close relationship with triple energizers(三焦). Stomach is an important organ that feeds acquired qi(後天之氣) based on food and stomach qi (胃氣) which is a transformed form by going through digestion, is significant for life conservation. In human body, the activation of stomach qi can be known by pulse. The true viscera pulse is a pulse which predicts the period of death. If stomach qi exsits, viscera qi can be led to greater yin of hand(手太陰), however, when it does not exist, five viscera qi can not be led to greater yin of hand and this kind of situation appears the true viscera pulse. Hence, by knowing the relation between stomach qi and five viscera qi, the condition of normality, disease, and death can be known. In "Hwangdineijing" it says, stomach qi, shortly string like pulse(微弦), shortly surging pulse(微鉤), shortly floating pulse(微毛), and shortly sunken pulse(微毛) shown in four seasons are normal pulse. And also it emphasizes, normal pulse is made when four seasons, five viscera pulse, and stomach qi are in harmony. In conclusion, stomach qi is based on food for well being, and a standard of judging people whether they are living in a healthy life or not.

Development of Ozone Generating System Applying Forward Type High Voltage Pulse Power Supply (Forward형 고압펄스 전원장치를 적용한 오존발생 시스템 의 개발)

  • 김동희;원재선;김경식;이광식;정도영;오승훈
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.7
    • /
    • pp.335-342
    • /
    • 2003
  • This paper presents a forward type high voltage pulse power supply for high voltage small current, which can be designed as a simple circuit configuration and managed easily using Power-MOSFET in the view of commercialization. According to the switching frequency, coupling factor(k) and duty ratio(D), the Principle of basic operation and the characteristics of the proposed pulse power supply are estimated. Simulation results have demonstrated the feasibility of the proposed pulse power supply. Also experimental results are presented to verify theoretical discussion with a lamp type ozonizer as a load. For studying the application at the part of environment of water, When ozonizer gas reacts with a colon bacillus, the sterilization characteristics of a colon bacillus according to the ozone concentration and response time have been investigated. This proposed pulse power supply will be able to be practically used as a pulse power supply in various environment improvement facilities like sterilization of colon bacillus, deodorization, and Nox gas elimination.

Fabrication and Properties of Ni and Ni-W Electroplated Molds Using LIGA-like Process for Replication of Micro Components (LIGA-like 공정을 이용한 마이크로 부품 복제용 Ni과 Ni-W 금형 제조 및 특성)

  • Hwang, W.S.;Park, J.S.;Kang, Y.C.;Cho, J.W.;Park, S.S.;Lee, I.G.;Kang, S.G.
    • Korean Journal of Materials Research
    • /
    • v.13 no.1
    • /
    • pp.6-10
    • /
    • 2003
  • Electroplated Ni and Ni-W micro-molds using LIGA-like process for replication of micro-components such as microfluidic parts and micro optical parts have been investigated. In general, it is hard to produce micro-parts using conventional mechanical processes. Micro-mold formed by LIGA-like process could fabricate micro-parts with high aspect ratio. In this paper, fabrication and properties of electroplated Ni molds with varying applied current types as well as those of Ni-W molds were investigated. Ni molds fabricated under pulse-reverse current showed the highest hardness value of about 160 Hv. Ni-W molds showed the hardness of about 500 Hv which was much harder than that of Ni electroplated molds. The above results suggested that high quality micro-molds could be fabricated by using Ni electroplating of pulse-reverse type for core molds and sequential Ni-W alloys coating.

Effect of Laser Acupuncture on Arterial Pulse

  • Cho, Jaekyong;Kang, Dong Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.191-197
    • /
    • 2015
  • Laser acupuncture is defined as the stimulation of traditional acupuncture points with low-intensity, nonthermal laser irradiation. Possible advantages in using laser acupuncture are the noninvasive, painless and low risks of infection treatment. The purpose of this study is to assess the effect of laser acupuncture on the quality and waveform of arterial pulses. Ten acupuncture points were stimulated repeatedly three times in 30 individuals by laser with emission in the near infrared spectral region (808 nm) using an out power and power density of 45 mW and $143W/cm^2$. The analysis of pulse quality and waveform was performed based on the measurement of arterial pressure of the left and right wrist, using a 3-dimensional blood pressure pulse analyzer. Excess-like pulse quality of subjects before laser acupuncture changed significantly to balanced pulse quality after 10, 20, and 30 minutes of laser acupuncture; coefficient of deficient or excess, $C_{DE}$, decreased significantly from 0.68 before acupuncture to 0.61, 0.55, and 0.55 after 10, 20, 30 minutes of laser acupuncture ($$p{\leq_-}0.006$$), respectively. Other pulse qualities, floating or sinking, slow or rapid, choppy or slippery did not change significantly by laser acupuncture (p > 0.05). Pulse waveform analysis showed that amplitude of main peak (systolic function or aortic compliance, $h_1$) of left and right artery pulse waves decreased significantly after 10, 20, and 30 minutes of laser acupuncture (p < 0.05). Other parameters, duration of one cardiac cycle (T), duration of rapid systolic ejection ($T_1$), duration of the systolic phase ($T_4$), and duration of the diastolic phase ($T_5$) of left and right artery pulses did not change significantly after laser acupuncture (p > 0.05).

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

Study on the new development of combined electrochemical processes using pulse current (마이크로 펄스 전해 복합가공에 관한 연구)

  • 박정우;이은상;문영훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.918-921
    • /
    • 2002
  • Some investigators who have tried to achieve the highly smooth surface finish using electrochemical processes have reported that high current density produced lustrous surfaces while the opposite conditions produced a passive layer and had a tendency to produce a black surface. However, processing at a low current density may produce a non-lustrous surface but the improvement of dimensional accuracy of the surface is significant. The surface with pulse process was a bit more lustrous than with continuous current but the black passive layer still could be found at grooved surface. There are two ways to achieve highly smooth surface finish. One is brushing it with a brush the other is electrochemical machining (ECM) with high current. The former method is the most common polishing practice, but not only may the surface obtained differ from operator to operator, but precision smooth surface on micro grooves are difficult to obtain. The latter one recently has been used to produce a highly smooth surface after EDM process. However, the material removal rate in ECM with high current is relatively high. Hence the original shape of the micro grooves, which was formed by electrochemical micro-machining (EMM) process, may be destroyed. In this study, an electrochemical polishing process using pulse current is adopted as a possible alternative process when micro grooves formed by EMM process should be polished. Mirror-like micro grooves with lustrous and smooth surface can be produced electrochemically with pulse current because the voltage and current used can be lower than the case of continuous current. This study will discuss the accurate control of physical and electrical conditions so as to achieve mirror-like micro grooves with lustrous and smooth surface without destroying the original shape of micro grooves.

  • PDF

The Characteristics of the Output Voltage Ferroelectrics for High Voltages Pulse Generators (고전압 펄스 발생기를 위한 강유전체의 전압 출력 특성)

  • Jang, Dong-Gwan;Choi, Sun-Ho;Hwang, Sunl-Mook;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1408-1412
    • /
    • 2013
  • High power pulse generating technology is to accumulate the energy for relatively long and then to create a strong force by emitting the energy very fast. High power pulse generating technology has recently been using in various fields like environments, industry, research, military and so on. Numerous studies about high power pulse generators have already been performed and commercialized in various conditions. However, in aspect of their size and weight, it is hard to carry the generators which currently have been developed. For these reasons, din nations like America or Russia, the researches have been performed for Ferroelectric Generators(FEG), which have relatively simple structure and are economical. To realize the ferroelectric generator, in this study, we selected the PZTs which have different physical properties respectively, and then shocked them using explosives. The PZT samples with volumes of $0.31{\sim}0.94cm^3$ were depolarized by shocked and produced the waveform that have peak voltages of 4.28 ~ 15kV. The lowest relative permittivity sample generated much higher peak voltage. And sudden voltage drops which seem to be caused by dielectric breakdown were observed in some experiments using low young's modulus samples. Also, increase in thickness led to increase in peak voltage, but the ratio of the voltage rise did not reach the ration of the thickness increase.

Time variation characteristic of pulse-modulated high frequency plasma (펄스 모듈레이션된 고주파 플라즈마의 시변 특성)

  • Lee, S.H.;Lee, D.S.;Jo, Y.S.;Kim, D.H.;Lee, H.J.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1817-1819
    • /
    • 2004
  • From the plasma application point of view, electron temperature and density are one of the most important parameters for plasma process. But it is only available to control plasma by adjusting external factors like gas pressure and input power. In this paper, pulse-modulated plasma is generated by modulating 13.56GHz RF power with 1, 5, 10kHz pulse. And Langmuir probe technique is used to study the distribution of electron temperature and density. When modulated pulse is off, electron temperature decreases gradually in form of exponential decay. The value t of exponential decay slope is 33.619, 13.834, 10.803 in 1kHz. 5kHz. 10kHz. This implies that this method can be used to control electron temperature and density.

  • PDF

Performance Characteristics of Hydrogen Peroxide Mono Propellant PDE (Pulse Detonation Engine) (과산화수소 단일 추진제 PDE의 성능 특성에 관한 수치적 연구)

  • Cho, Heung-Sik;Jeung, In-Seuck;Choi, Jeong-Yeol
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.153-157
    • /
    • 2003
  • Supersonic and hypersonic aircrafts must pass wide range of speed to reach high speed region. But for existing engines the most efficient operating speed ranges are decided according to their flying speed, so an engine which mixes several engines like TRJ (Turbo Ramjet) and ARJ (Air Turbo Ramjet) has been planed. This mixed type engine has inefficiency that more than two engines must be installed simultaneously, but the pulse detonation engine (PDE) that uses detonation wave has a strong point that it can operate in all speed range with single engine. This paper deals with the simulation of the pulse detonation engine which uses hydrogen peroxide $(H_2O_2)$ mono propellant. Hydrogen peroxide is low-cost propellant, and it is reacted without oxidizer. Comparison between $H_2-O_2$ mixture with $H_2O_2$ mono propellant about thrust, pressure, temperature and velocity shows that $H_2O_2$ is a very useful propellant.

  • PDF