• Title/Summary/Keyword: pulse-like

Search Result 295, Processing Time 0.032 seconds

Antidepressant Effects of Gammakdaejo-Tang on Repeated Immobilization Stress in the Ovariectomized Female Rats

  • Park, Hyun-Jung;Shim, Hyun-Soo;Lee, Hye-Jung;Yun, Young-Ju;Shim, In-Sop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.5
    • /
    • pp.876-880
    • /
    • 2011
  • Gammakdaejo-Tang (GMT) is a traditional oriental medicinal formula, a mixture of 3 crude drugs, and it has been clinically used for treating mild depressive disorders. The purpose of the study was to examine the effect of Gammakdaejo-Tang (GMT) on repeated stress-induced alterations of learning and memory on a passive avoidance test (PAT) test and also the anxiety-related behavior on the elevated pulse maze (EPM) in ovariectomized female rats. We assessed the changes in the reactivity of the cholinergic system by measuring the immunoreactive neurons of choline acetyltransferase (ChAT) in the hippocampus after behavioral testing. The rats were exposed to the immobilization (IMO) stress for 14 days (2hours/day), and Gammakdaejo-Tang (400 mg/kg, p.o.) was administered 30 min before IMO stress. Treatments with GMT caused significant reversals of the stress-induced deficits in learning and memory on a working memory test, and it also produced an anxiolytic-like effect on the EPM, and increased the ChAT reactivities (p<0.001, respectively). These results suggest that Gammakdaejo-Tang might prove to be an effective antidepressant agent.

A New Zero-Current-Transition Buck Converter (새로운 영전류 천이형 벅 컨버터)

  • 최현칠
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.556-563
    • /
    • 2001
  • In this paper a new zero current transition pulse width modulation (ZCT-PWM) buck converter is proposed to combine the desirable feature of both the conventional buck converter and resonant converters. In this proposed scheme an auxiliary circuit is added to the conventional buck converter and used to achieve soft-switching for both the main switch and the freewheeling diode while not incurring any additional losses due to auxiliary circuit And this converter operates exactly like the conventional PWM converter except for a short particular time interval. The operation of the proposed converter is explained and analyzed. and design guidelines are presented. To validate the feasibility of the proposed converter, a 100KHz 180-W prototype is built and tested.

  • PDF

The Effect of Yangganhwadam-tang(YHT) on Hypertension (양간화담탕(凉肝化痰湯)이 고혈압에 마치는 영향)

  • Oh, Yong-Sung;An, Joung-Jo;Jo, Hyun-Kyung;Yoo, Ho-Rhyong;Seol, In-Chan;Kim, Yoon-Sik
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.4
    • /
    • pp.657-673
    • /
    • 2009
  • This experiment was performed to determine the antihypertensive effect of Yangganhwadam-tang(YHT) on hypertension in spontaneously hypertensive rat. The results obtained were as follows : 1. YHT showed scavenging activity on DPPH free radical and SOD-like activity. 2. YHT significantly decreased heart weight. 3. YHT significantly decreased blood pressure and pulse. 4. YHT significantly decreased the level of plasma aldosterone. 5. YHT significantly decreased the level of norepinephrine. 6. YHT significantly decreased the levels of potassium and calcium. 7. YHT significantly decreased the level of BUN. 8. YHT decreased eosinophilic changes in the heart cells, and dilated renal arterioles stenosis. These results suggest that YHT might be effective in treatment and prevention of hypertension.

  • PDF

Characteristics of 1.9 GHz On-Glass Antenna for Automobil Telephone (차량전화용 1.9 GHz On-Glass 안테나의 특성)

  • 김태원;이원용;김정기
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.3
    • /
    • pp.211-218
    • /
    • 1996
  • Theorectical and experimental studies of On-Glass antenna in the 1.9GHz bandare performed. In this paper, the structure of designed On-Glass antenna consists of a 5/8-wavelength upper segment and quarter-wavelength lower segment separated by phasing coil. On-Glass antenna may be resonated by the use of suitably spaced phasing coil in series with the antenna wire. This tuning structure leads to an improvement in antenna efficiency. And then, this can be very useful for installation where limited space like automobil is available. The analytical method is based on collocation method with pulse function. The results obtained from numerical method are presented and compared with an experimental evaluation. From this, the VSWR, gain, radiation pattern, and bandwidth of the On-Glass antenna are analyzed.

  • PDF

Characteristics of Acoustic Impulse Response of Submerged Cylindrical Objects as Elements of Target-Scattered Echo (표적신호 시뮬레이션 요소로서 원통형 몰수체의 충격응답의 특성)

  • Kim, Jae-Soo;Seong, Nak-Jin;Lee, Sang-Young;Kim, Kang;Yu, Myong-Jong;Cho, Woon-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2E
    • /
    • pp.5-13
    • /
    • 1994
  • Simulation of the target-scattered echo requires the understanding of scattering mechanism at the highlight points. In this paper, the basic assumption of Highlight Model is reviewed through the analyzed data obtained in the acoustic water tank experiment. The analysis shows that the scattering mechanism involves pulse elongation and frequency shift as elements of target-scattered echo, and that the internal structures affect the temporal response of the target-scattered echo significantly. The band-limited impulse response or Green's function due to the diffraction from highlight points of internal structures is not mere delta function, but acts like a filter, which causes frequency shift and is elongated in time.

  • PDF

The Effects of Jibeakjihwanghwangami(JJHG) on Monocrotaline-induced Hypertensive Rats (지백지황환가미(知柏地黃丸加味)가 monocrotaline으로 유발된 흰쥐의 고혈압 병태모델에 미치는 영향)

  • Kim, Jong-Won;An, Joung-Jo;Jo, Hyun-Kyung;Yoo, Ho-Ryong;Seol, In-Chan;Kim, Yoon-Sik
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.3
    • /
    • pp.684-702
    • /
    • 2008
  • This experiment was performed to determine the effect of Jibeakjihwanghwangami(JJHG) on hypertension in monocrotaline-induced hypertensive rats. The results obtained were as follows : 1. JJHG showed a safety in cytotoxicity and toxicity of liver. 2. JJHG showed scavenging activity on DPPH free radicals and SOD-like activity. 3. JJHG showed an inhibitory effect on ACE. 4. JJHG significantly decreased blood pressure and pulse in monocrotaline-induced hypertensive rats. 5. JJHG significantly decreased the levels of plasma aldosterone in monocrotaline-induced hypertensive rats. 6. JJHG significantly decreased the levels of potassium in monocrotaline-induced hypertensive rats. 7. JJHG significantly decreased the levels of uric acid. BUN, and creatinine in monocrotaline-induced hypertensive rats. These results suggest that JJHG might be effective in treatment and prevention of hypertension.

  • PDF

Development and Applications of TOF-MEIS (Time-of-Flight - Medium Energy Ion Scattering Spectrometry)

  • Yu, K.S.;Kim, Wansup;Park, Kyungsu;Min, Won Ja;Moon, DaeWon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.107.1-107.1
    • /
    • 2014
  • We have developed and commercialize a time-of-flight - medium energy ion scattering spectrometry (TOF-MEIS) system (model MEIS-K120). MEIS-K120 adapted a large solid acceptance angle detector that results in high collection efficiency, minimized ion beam damage while maintaining a similar energy resolution. In addition, TOF analyzer regards neutrals same to ions which removes the ion neutralization problems in absolute quantitative analysis. A TOF-MEIS system achieves $7{\times}10^{-3}$ energy resolution by utilizing a pulsed ion beam with a pulse width 350 ps and a TOF delay-line-detector with a time resolution of about 85 ps. TOF-MEIS spectra were obtained using 100 keV $He^+$ ions with an ion beam diameter of $10{\mu}m$ with ion dose $1{\times}10^{16}$ in ordinary experimental condition. Among TOF-MEIS applications, we report the quantitative compositional profiling of 3~5 nm CdSe/ZnS QDs, As depth profile and substitutional As ratio of As implanted/annealed Si, Ionic Critical Dimension (CD) for FinFET, Direct Recoil (DR) analysis of hydrogen in diamond like carbon (DLC) and InxGayZnzOn on glass substrate.

  • PDF

Improvement of ESD (Electrostatic Discharge) Protection Performance of NEDSCR (N-Type Extended Drain Silicon Controlled Rectifier) Device using CPS (Counter Pocket Source) Ion Implantation (CPS 이온주입을 통한 NEDSCR 소자의 정전기 보호 성능 개선)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.1
    • /
    • pp.45-53
    • /
    • 2013
  • An electrostatic discharge (ESD) protection device, so called, N-type extended drain silicon controlled rectifier (NEDSCR) device, was analyzed for high voltage I/O applications. A conventional NEDSCR device shows typical SCR-like characteristics with extremely low snapback holding voltage. This may cause latch-up problem during normal operation. However, a modified NEDSCR device with proper junction/channel engineering using counter pocket source (CPS) ion implantation demonstrates itself with both the excellent ESD protection performance and the high latch-up immunity. Since the CPS implant technique does not change avalanche breakdown voltage, this methodology does not reduce available operation voltage and is applicable regardless of the operation voltage.

3D RECONSTRUCTION OF LANDSCAPE FEATURES USING LiDAR DATAAND DIGITAL AERIAL PHOTOGRAPH FOR 3D BASED VISIBILITY ANALYSIS

  • Song, Chul-Chul;Lee, Woo-Kyun;Jeong, Hoe-Seong;Lee, Kwan-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.548-551
    • /
    • 2007
  • Among components of digital topographic maps used officially in Korea, only contours have 3D values except buildings and trees that are demanded in landscape planning. This study presented a series of processes for 3Dreconstructing landscape features such as terrain, buildings and standing trees using LiDAR (Light Detection And Ranging) data and aerial digital photo graphs. The 3D reconstructing processes contain 1) building terrain model, 2) delineating outline of landscape features, 3) extracting height values, and 4) shaping and coloring landscape features using aerial photograph and 3-D virtual data base. LiDAR data and aerial photograph was taken in November 2006 for $50km^{2}$ area in Sorak National Park located in eastern part of Korea. The average scanning density of LiDAR pulse was 1.32 points per square meter, and the aerial photograph with RGB bands has $0.35m{\times}0.35m$ spatial resolution. Using reconstructed 3D landscape features, visibility with the growing trees with time and at different viewpoints was analyzed. Visible area from viewpoint could be effectively estimated considering 3D information of landscape features. This process could be applied for landscape planning like building scale with the consideration of surrounding landscape features.

  • PDF

Evaluation of Radiation Entrance Surface Dose Rates for Interventional Radiology Equipment (인터벤션 방사선발생장치에서 입사표면선량률 평가)

  • Kang, Byung-Sam;Chang, Kwang-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.353-357
    • /
    • 2020
  • IVR procedures are on the rise, and patient doses are on the rise. It is necessary to evaluate fluoroscopy dose in IVR procedure. Evaluate ESD on IVR equipment as a reference to DRL settings, I would like to present the direction of improvement in the ESD rate test criteria for fluoroscopy dose. The experimental method is measured with 6cc ionization chamber under the 20cm PMMA Phantom. Radiation is subject to abdominal procedure. The average dose rate of the incident surface was 21.6 ± 11.4 mGy/min. The highest dose equipment was 58.5 mGy/min, and there was no equipment exceeding the domestic standard of 100 mGy/min. However, there were five units above 50 mGy/min. To reduce fluoroscopy dose, it is recommended to reduce pulse rate, The dose increases as the image receptor ages. It is recommended to modify the domestic inspection criteria to 50 mGy/min.