• 제목/요약/키워드: pulse wave detection system

검색결과 59건 처리시간 0.031초

맥율진단을 위한 데이터베이스에 관한 연구 (A study on database for pulse rate diagnosis)

  • 한순천;김현규;이용동;박영배;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.569-572
    • /
    • 1998
  • In this paper, we devised pulse rate diagnosis for provide basic index of cold-hot diagnosis. The system consist of database part and pulse rate detection part for detection pulse wave, respiration and ECG. The database is constructed windwos95 platform using DAO(data access object). Search algorithm used ISAM algorithm. The database consist of one's information and medical report for a subject and detected pulse wave.

  • PDF

새로운 맥파 인식 알고리즘을 적용한 자동 맥파 시스템에 관한 연구 (A Study on the Auto-diagnosis Plethysmograph by Novel Algorithm for Radial Pulse Detection)

  • 박승환;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.241-246
    • /
    • 1996
  • This paper describes a new system that detects radial pulse wave and allows the diagnosis of malfunctions of cardiovascular system by analyzing the waveforms with the newly proposed algorithm. The system consists of a sensor part and a data processing part within which a new detection algorithm is incorporated In acquiring radial pulse signal noninvasively, the sensor used in this system is a new combinational fiber-optic sensor which has a detecting Part and a transmitting Part. Also, In order to analyze the characteristics of pulsation quantitatively, the algorithm proposed in this paper is a method that runs in parallel with both the data of ECG and differential pulse simultaneously. these concepts are based upon the idea that thfee Q points of ECG give obious discrimination of one entire period of pulse in any abnormal cases, and newly defined feature lines at the differential counterpart can be used to recogrlize sDme significant points in one period of pulses.

  • PDF

4 채널의 Photo-plethysmogram 시스템 구현에 관한 연구(I) (Implementation of 4 Channel Photo-Plethysmogram System(I))

  • 김형태;한순천;김정국;허웅;박영배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.253-256
    • /
    • 2002
  • In this paper, we implement the volume pulse detection system which can quantitatively represent an artery elasticity. The system consists of transducer which has IRLED-photodiode detecter, temperature sensor, filters, preprocessing circuits, A/D converter, serial communication part and computer system. In order to presume the artery elasticity information we measure the volume pulse at four points and then evaluate the transition time, distance and the correlation coefficient of the pulse wave between the points. We test the system with 10 subjects during the week for basic experiment and obtain the data at four points. As the result of experiment, we can detect normalized volume pulse wave and evaluated parameter with effectively.

  • PDF

U-헬스케어를 위한 퍼지추론과 다중 하위대역 필터를 기반한 맥파 최대치 검출 (Peak Detection of Pulse Wave Based on Fuzzy Inference and Multi Sub-Band Filters for U-Healthcare)

  • 이주원;이병로
    • 한국정보통신학회논문지
    • /
    • 제12권12호
    • /
    • pp.2159-2164
    • /
    • 2008
  • 유비쿼터스 헬스케어 시스템은 사용자의 건강 정보를 감독하고 관리하는 시스템이며, 이 헬스케어 시스템에서 가장 중요한 점은 측정된 건강 데이터의 정확성이다. 그러나 실생활에서는 사용자의 움직임 에 따라 그 정확성이 현저하게 달라진다. 따라서 건강 정보 정확성을 향상시키기 위해 본 연구에서는 심박수 추출에 있어 새로운 맥파 최대점 검출 알고리즘을 제안하였고, 제안된 알고리즘은 다중 하위 대역 필터와 퍼지 추론기를 이용하여 동잡음이 포함된 PPG 신호에서 맥파의 최대점을 검출하기 위한 것이다. 제안된 알고리즘에 대한 성능평가 실험에서 복잡한 동잡음에서도 맥파 최대점 추출이 가능함을 보였다.

펄스파 자왜 센서를 이용한 고정밀 액위 센서 시스템의 실현에 관한 연구 (Implementation of High Accurate Level Sensor System using Pulse Wave Type Magnetostriction Sensor)

  • 최우진;이준탁
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.395-400
    • /
    • 2013
  • In this paper, we introduce the implementation of high accurate level sensor system using the pulse wave type magnetostriction sensor. When a current pulse flows along the waveguide, the magnetic field also propagates towards the end of waveguide. When this magnetic field just passes the position of the magnet for level detection, the resultant magnetic field by these two magnetic fields makes a torsional reflected signal. This is used to calculate the time difference between a interrogation pulse wave and this torsional reflected signal. The key elements and characteristics were investigated to implement level sensor system based on this principle. We introduce a method to calculate the speed of ultrasonic reflected signal and how to make a model of sensing coil. In particular, we experiment with the characteristics of the torsional reflected signal according to the changes of the interrogation voltage and displacement. To make high accurate level sensor system, two methods were compared. One is to use the comparator and time counter, the other is STFT(Short Time FFT) which is capable of the time-frequency analysis.

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.

조합형 광섬유 트랜스듀서에 의한 요골맥파의 검출 (Detection of Radial Pulse by Combinational Fiber-optic Transducer)

  • 박승환;홍승홍
    • 센서학회지
    • /
    • 제7권3호
    • /
    • pp.197-202
    • /
    • 1998
  • 맥파신호는 심장과 심혈관계에 관련된 중요한 정보를 포함하고 있는 중요한 생체신호이다. 본 연구에서는 맥파신호를 비관혈적으로 검출하기 위해 기존의 기계적 변환방식의 개념에 근거하여 광섬유를 이용하는 맥파 검출용 트랜스듀서를 새로이 개발하여 사용하였다. 기계적 변환방식에서 발생될 수 있는 맥동전달 효율을 개선시키기 위해 본 연구에서는 맥동하는 피부와 접촉하여 센서에 전달하는 검출부(detecting part)와, 전달받은 변위운동을 광 출력 변화에 따른 전기 신호로 변환하는 감지부(sensing part)의 두 부분이 조합된 구조를 갖는 설계방식을 제안하였다. 우리는 이러한 조합형 구조의 설계방식을 이용한 결과로 기존의 트랜스듀서로 검출이 어려운 맥파의 C점(절흔)과 T파를 검출할 수 있음을 확인하였다.

  • PDF

A Study on Database for Pulse Rate Diagnosis

  • S. C. Han;Kim, H. K.;Lee, Y. D.;W. Huh;Park, Y. B.
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.539-542
    • /
    • 1998
  • In this paper, we devised pulse rate diagnosis database system for provide basic index of Cold-Hot diagnosis. The system consist of database part and pulse rate detection part that for detection pulse wave, respiration and ECG. The database is constructed windows95 platform using DAO(Data Access Object). Search algorithm used ISAM algorithm. The database consist of patient information and medical report for a subject and detected biological signals.

  • PDF

한방 맥 진단에 관한 연구 (A study on Radial pulse diagnosis of the korean medicine)

  • 이호재;김진우;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.71-74
    • /
    • 1992
  • This paper describes research about the realization of computerized radial pulse diagnosis system in order to remove the subjectivity of a diagnostician, when diagnostician diagnoses a sickness using tactile percept ion in korean traditional medicine. Using radial pulse wave detection system, we effectively measured pressure radial pulse rave and after analyzing it, we detected the characteristic parameters and also quantified it and then we objectified more or less the judgement standard of radial pulse diagnosis by the aids of a clinical expert. on this base, we confirmed the possibility for realizing of automatic radial pulse diagnosis by radial pulse diagnosis system.

  • PDF

초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출 (Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography)

  • 조재완;서용칠;정승호;김승호;정현규
    • 한국세라믹학회지
    • /
    • 제43권4호
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.