• 제목/요약/키워드: pulse transit time

검색결과 66건 처리시간 0.033초

Radial Electrical Impedance: A Potential Indicator for Noninvasive Cuffless Blood Pressure Measurement

  • Huynh, Toan Huu;Chung, Wan-Young
    • 센서학회지
    • /
    • 제26권4호
    • /
    • pp.239-244
    • /
    • 2017
  • Noninvasive, cuffless, and continuous blood pressure (BP) monitoring is essential to prevent and control hypertension. A well-known existing method for this measurement is pulse transit time (PTT), which has been investigated by many researchers as a promising approach. However, the fundamental principle of the PTT method is based on the time interval taken by a pulse wave to propagate between the proximal and distal arterial sites. Consequently, this method needs an independent system with two devices placed at two different sites, which is a problem. Even though some studies attempted to synchronize the system, it is bulky and inconvenient by contemporary standards. To find a more sensitive method to be used in a BP measurement device, this study used radial electrical bioimpedance (REB) as a potential indicator for BP determination. Only one impedance plethysmography channel at the wrist is performed for demonstrating a ubiquitous BP wearable device. The experiment was evaluated on eight healthy subjects with the ambulatory BP monitor on the upper arm as a reference. The results demonstrated the potential of the proposed method by the correlation of estimated systolic (SBP) and diastolic (DBP) BP against the reference at $0.84{\pm}0.05$ and $0.83{\pm}0.05$, respectively. REB also tracked the DBP well with a root-mean-squared-error of $7.5{\pm}1.35mmHg$.

The transport property of direct conversion material a-Se:As film for digital radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.343-344
    • /
    • 2007
  • Carrier mobility was measured using time-of-flight (TOF) measurements to investigate the transport properties of holes and electrons in stabilized a-Se film. A laser beam with pulse duration of 5 ns and wavelength of 350 nm was illuminated on the surface of a-Se with thickness of $400\;{\mu}m$. The measured transit times of hole and electron were about $8.73\;{\mu}s\;and\;229.17\;{\mu}s$, respectively. The experimental results showed that the hole and electron drifting mobility were $0.04584\;cm^2V^{-1}S^{-1}\;and\;0.00174\;cm^2V^{-1}s^{-1}\;at\;10\;V/{\mu}m$.

  • PDF

Measurement of Drifting Mobility and Transit Time of Holes and Electrons in Stabilized a-Se Film

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.362-363
    • /
    • 2007
  • The transport property of stabilized amorphous selenium typical of the material used in direct conversion x-ray imaging devices was studied using the moving photo-carrier grating (MPG) technique and time-of-flight (TOF) measurements. For MPG measurement, the electron and hole mobility, and recombination lifetime of a-Se films with arsenic (As) additions have been obtained. For TOF measurement, a laser beam with pulse duration of 5ns and wavelength of 350 nm was illuminated on the surface of a-Se with thickness of $400{\mu}m$.

  • PDF

놀람 자극에 대한 심혈관 반응 (Cardiovascular response to surprise stimulus)

  • 엄진섭;박혜준;노지혜;손진훈
    • 감성과학
    • /
    • 제14권1호
    • /
    • pp.147-156
    • /
    • 2011
  • 여러 연구자들이 정서특정적 자율신경계 활동을 밝히기 위하여 행복, 슬픔, 분노, 공포 및 혐오를 포함한 기본 정서들을 사용하여왔지만, Ekman 등(1983)의 기본정서들 중 놀람 정서에 대한 연구는 많지 않다. 본 연구의 목적은 ECG와 PPG를 이용하여 놀람 자극에 대한 심혈관 반응을 밝히는 것이다. 76명의 대학생에게 놀람자극을 제시하기 전과 후에 ECG와 PPG를 기록하였으며, ECG와 PPG 신호로부터 심박률(HR), R-R 간격의 표준편차(SD-RR), 연속된 R-R 간격 차이의 제곱평균제곱근(RMSSD-RR), 호흡성 부정맥(RSA), 손가락 혈류량 파형의 진폭(FBVPA), 손가락 맥파 전달시간(FPTT)을 산출하였다. HR과 SD-RR, RMSSD-RR은 놀람자극 제시 전에 비하여 놀람자극이 제시된 후에 유의하게 증가하였으며, FBVPA는 유의하게 감소하였고, FPTT는 유의하게 짧아졌다. 놀람 자극은 말초혈관을 수축시키고, 심박률을 증가시키는 교감신경계 반응특성을 가지는 것으로 볼 수 있으며, 심박률 변산성을 증가시키는 부교감신경계도 동시에 활성화될 가능성이 있는 것으로 나타났다. 이러한 연구 결과는 정서이론의 발전과, 인간정서를 탐지하는 컴퓨터 시스템의 기초를 확립하는데 기여하는 바가 있을 것이다.

  • PDF

인지과제 수행시 배경 소음의 크기에 따른 생리적 반응차 (The role background noise intensity on Physiological activity during performance of mental task)

  • 손진훈;;민윤기;이경화;최상섭
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.269-273
    • /
    • 1999
  • Combination of mental stress task with noise background is a traditional tool employed in psychophysiology. However, intensity of background noise is a factor affecting both performance on test and psychophysiological responses associated with stress evoked by mental load in noisy environment. In the current study on 7 subjects we analyzed the influence of white noise (WN) intensity (55, 70, and 85 dB[A] ) on psychophysiological responses during word recognition test performed on noise background. There were recorded following physiological variables: electrodermal activity (EDA) , namely, skin conductance level (SCL), skin conductance response (SCR) amplitude (SCR-A), rise time and total number of SCRs (N-SCR); cardiovascular activity, e.g., heart rate (HR), respiratory sinus arrhythmia (RSA) index, pulse transit time (PTT), finger pulse volume (PV), skin temperature (SKT) and respiratory activity, such as respiration rate (RESP-R) and inspiration wane amplitude (RESP-A) during baseline resting state and 40 s long performance on 3 similar Korean word recognition tests with different WN intensity (55, 70, and 85 dB). Electrodermal responses (SCR-A, SCL, N-SCR) demonstrated gradual increment with increased intensity of noise, and this increase of response magnitude with higher intensity of noise was typical also for r skin temperature (phasic SKT decrease) and pulse volume (phasic and tonic PV decrease). However, some cardiovascular and respiratory responses did not exhibit same tendency of gradual increase of reactivity , namely HR, as well as RESP-R and RESP-A showed decrement of response magnitudes. Important finding in terms of cardiovascular reactivity was that 55 and 70dB evoked similar profiles, while 85dB WN resulted in significantly different profile of reactions, suggesting that there exists a threshold level after which intensive auditory stimulation elicits psychophyslological responses pattern of different quality. There are discussed potential autonomic mechanism involved in mediation of observed physiological responses.

  • PDF

Transport Properties of Conversion Materials for Digital Radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권6호
    • /
    • pp.250-254
    • /
    • 2007
  • Applying the moving photo-carrier grating(MPG) technique and time-of-flight(TOF) measurements, we studied the transport properties of stabilized amorphous selenium typical of the material used in direct conversion X-ray imaging devices. For MPG measurement, we obtained electron and hole mobility and the recombination lifetime of $\alpha-Se$ films with arsenic(As) additions. We found an apparent increase in hole drift mobility and recombination lifetime, especially when 0.3 % As was added into $\alpha-Se$ film, whereas electron mobility decreased with the addition of As due to the defect density. For TOF measurement, a laser beam with pulse duration of 5 ns and wavelength of 350 nm was illuminated on the surface of $\alpha-Se$ with a thickness of 400 ${\mu}m$. The measured hole and electron transit times were about 8.73 ${\mu}s$ and 229.17 ${\mu}s$, respectively.

두 개의 광전용적맥파 기반의 수축기 혈압과 이완기 혈압 추정 융합 알고리즘 모델 분석 (Analysis of the Convergence Algorithm Model for Estimating Systolic and Diastolic Blood Pressure Based on Two Photoplethysmography)

  • 김선칠;조성현
    • 한국융합학회논문지
    • /
    • 제10권8호
    • /
    • pp.53-58
    • /
    • 2019
  • 최근 만성질환자 건강관리의 목적으로 혈압측정에 대한 접근성을 높이는 제품 연구가 지속적으로 이루어지고 있다. 기존 연구에서는 심전도(ECG)와 광전용전맥파(PPG)를 분석하여 수축기혈압과 이완기 혈압을 산출하는 방식을 사용하고 있다. 주 과제는 정확도와 재현성을 위한 분석 알고리즘 개발이다. 본 연구에서는 초소형 혈압측정장치를 개발하는 단계에서 장치의 크기를 줄이고 측정방법도 간단히 하는 동시에 알고리즘도 두 개의 PPG만을 이용하여 최고혈압(SBP)을 추출하고 이에 따른 최저혈압(DBP)을 구하고자 하였다. 이를 위해 두 개의 PPG에서 얻은 측정값과 SBP, DBP 관계를 통계적으로 추적하여 상호관계를 분석하였다. PPG의 차이 값인 DF_P는 SBP와 반비례 관계가 있으며, DBP와는 비례적 관계가 성립되어 알고리즘에 의해 혈압값을 유추할 수 있으며, SBP를 통해 DBP를 추적할 수 있다.

PTT를 이용한 수축기 혈압의 측정에 관한 연구 (A Study on Estimation of Systolic Blood Pressure using PTT)

  • 박은경;이상민;한영호;이종연;권세윤;김인영;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.605-609
    • /
    • 2004
  • 혈압은 심혈관계 질환을 비침습적인 방법으로 진단할 때 사용하는 중요한 생리적 지표 중 하나이다. 보통 동맥 혈압을 측정하기 위해 사용되는 기존의 비침습적인 방법들은 커프를 사용해야 하며. 연속적 혈압 측정이 어렵다. 수축기 혈압과 맥파전달시간은 서로 반비례 관계를 가지고 있다. 실험은 피검자로부터 휴식을 통한 평온한 상태와 운동을 통한 격한 상태로부터 수축기 혈압과 맥파전달시간 데이터를 얻었다. 얻어진 데이터를 이용하여 각 피검자용 회귀식과 전체 피검자용 회귀식을 만들기 위해 선형회귀분석을 하였다. 만들어진 회귀식의 정확도를 검증하기 위해 측정한 수축기 혈압값과 예측한 수축기 혈압값을 비교하였다. 비교 결과, 각 피검자용 회귀식이 혈압계는 오차의 평균과 표준편차가 각각 ±5mmHg, 8 mmHg를 가져야 된다고 규정한 American National Standards Institute of the Association of the Advancement of Medical Instrument (ANSI/AAMI)에 적합하였다. 그러나 전체 피검자용 회귀식은 ANSI/AAMI의 규정에 적합하지 않았다. 이 결과는 맥파전달시간과 각 피검자에 맞는 초기 보정을 통해서 커프를 사용하지 않고, 연속적으로 수축기 혈압을 측정할 수 있음을 의미한다.

자세변화에 따른 PWV 변화량의 평가 (Estimation of the Variation of Quantity in PWV in Accordance with the Changes of Position in Human)

  • 전석환;정인철;정상오;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권2호
    • /
    • pp.129-134
    • /
    • 2009
  • The ideal method which measures a blood vessel of senility and degree of arteriosclerosis is to measure compliance of arterial and condition of blood circulation at the periphery. In these days vascular stiffness have been assessed by analyzing PTT (pulse transit time) from ECG and PPG. PTT is that between toe and finger each subject estimated through ECG and PPG signals. Two parameters, which are related to PWV, were tested with the time delay between the finger and toe. PWV is a variation of quantity which is associated with vascular stiffness. These researches which use PTT and PWV don't consider the blood vessel characteristic of an individual. In this current research, we have used with the blood vessel characteristic of an individual. That is an assessment of vascular stiffness using the variation of quantity in PWV with the changes of position in the subject. PWV variation increased as functions of the subject's age. The increase of the PWV variation parameters with age is attributed to the direct decrease of the blood vessel compliance with different position. The quantity of variation estimated by experimental results is that old age's (75.78${\pm}$7.75) case is 113.68% and young age's (26.47${\pm}$2.04) case is 85.69%. We proved and presented about estimation of vascular stiffness of possibility by this result.

웨어러블 초소형 혈압계 개발을 위한 혈압 추정 융합 알고리즘 분석 (Blood Pressure Estimation for Development of Wearable small Blood Pressure Monitor Fusion Algorithm Analysis)

  • 김선칠;권찬회;박유림
    • 한국융합학회논문지
    • /
    • 제10권11호
    • /
    • pp.209-215
    • /
    • 2019
  • 디지털헬스케어에서 가장 중요한 개인 건강관리는 주로 만성질환자에게 매우 중요한 문제이다. 따라서 실시간 건강관리를 위한 간단한 웨어러블 디바이스 개발이 중요하다. 기존 혈압 추정 웨어러블 디바이스는 PPG 특성을 통해 PTT를 분석하여 혈압 추정 알고리즘을 제안하고 있다. 그러나 PPG의 재현성과 여러 가지 PTT의 적용여부와 측정자의 신체적 차이에서 발생되는 변수 등 알고리즘의 영향인자가 사실 매우 복잡하다. 따라서 본 연구에서는 PTT와 SBP, DBP의 상관관계를 분석하고, 다바이스 소형화를 위해 PPG센서만을 사용하게 설계하였다. 제안된 혈압 추정 알고리즘은 PPG간의 차이와 심박수, 개인적인 변수 등을 고려하였다. 또한 기존 의료기관에서 사용하는 공기가압방식의 결과값과 개발된 알고리즘을 통해 추정된 혈압값과 비교를 통해 확인하였다.