• 제목/요약/키워드: pulse transfer time

검색결과 106건 처리시간 0.025초

Critical earthquake input energy to connected building structures using impulse input

  • Fukumoto, Yoshiyuki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제9권6호
    • /
    • pp.1133-1152
    • /
    • 2015
  • A frequency-domain method is developed for evaluating the earthquake input energy to two building structures connected by viscous dampers. It is shown that the earthquake input energies to respective building structures and viscous connecting dampers can be defined as works done by the boundary forces between the subsystems on their corresponding displacements. It is demonstrated that the proposed energy transfer function is very useful for clear understanding of dependence of energy consumption ratios in respective buildings and connecting viscous dampers on their properties. It can be shown that the area of the energy transfer function for the total system is constant regardless of natural period and damping ratio because the constant Fourier amplitude of the input acceleration, relating directly the area of the energy transfer function to the input energy, indicates the Dirac delta function and only an initial velocity (kinetic energy) is given in this case. Owing to the constant area property of the energy transfer functions, the total input energy to the overall system including both buildings and connecting viscous dampers is approximately constant regardless of the quantity of connecting viscous dampers. This property leads to an advantageous feature that, if the energy consumption in the connecting viscous dampers increases, the input energies to the buildings can be reduced drastically. For the worst case analysis, critical excitation problems with respect to the impulse interval for double impulse (simplification of pulse-type impulsive ground motion) and multiple impulses (simplification of long-duration ground motion) are considered and their solutions are provided.

인공위성 궤도전이 및 자세제어용 이원추진제 로켓엔진의 개발현황 (A Development Trend Study of Bipropellant Rocket Engine for Orbit Transfer and Attitude Control of Satellite)

  • 장요한;이균호
    • 한국추진공학회지
    • /
    • 제19권1호
    • /
    • pp.50-60
    • /
    • 2015
  • 인공위성의 추진시스템은 위성이 발사체로부터 분리된 후 최종 궤도로 도달할 때까지 궤도를 이동하는데 필요한 추력을 제공한다. 또한 임무궤도에서는 궤도 유지와 자세제어를 위한 펄스 모멘트를 발생하는 역할을 한다. 본 연구에서는 향후 인공위성 궤도전이 및 자세제어용 이원추진제 로켓엔진을 국내에서 개발시 관련 연구에 필요한 규격을 도출하기 위한 목적으로서 모노메틸하이드라진과 하이드라진을 연료로, 사산화이질소 산화제를 이용하는 인공위성용 이원추진제 로켓엔진에 대한 현재 개발동향 및 주요 성능 특성에 대해 조사하였다.

Efficiency calibration and coincidence summing correction for a NaI(Tl) spherical detector

  • Noureddine, Salam F.;Abbas, Mahmoud I.;Badawi, Mohamed S.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3421-3430
    • /
    • 2021
  • Spherical NaI(Tl) detectors are used in gamma-ray spectrometry, where the gamma emissions come from the nuclei with energies in the range from a few keV up to 10 MeV. A spherical detector is aimed to give a good response to photons, which depends on their direction of travel concerning the detector center. Some distortions in the response of a gamma-ray detector with a different geometry can occur because of the non-uniform position of the source from the detector surface. The present work describes the calibration of a NaI(Tl) spherical detector using both an experimental technique and a numerical simulation method (NSM). The NSM is based on an efficiency transfer method (ETM, calculating the effective solid angle, the total efficiency, and the full-energy peak efficiency). Besides, there is a high probability for a source-to-detector distance less than 15 cm to have pulse coincidence summing (CS), which may occur when two successive photons of different energies from the same source are detected within a very short response time. Therefore, γ-γ ray CS factors are calculated numerically for a 152Eu radioactive cylindrical source. The CS factors obtained are applied to correct the measured efficiency values for the radioactive volumetric source at different energies. The results show a good agreement between the NSM and the experimental values (after correction with the CS factors).

Reinforcing effect of CFRP bar on concrete splitting behavior of headed stud shear connectors

  • Huawen Ye;Wenchao Wang;Ao Huang;Zhengyuan Wang
    • Steel and Composite Structures
    • /
    • 제48권2호
    • /
    • pp.131-143
    • /
    • 2023
  • The CFRP bar was used to achieve more ductile and durable headed-stud shear connectors in composite components. Three series of push-out tests were firstly conducted, including specimens reinforced with pure steel fibers, steel and CFRP bars. The distributed stress was measured by the commercial PPP-BOTDA (Pre-Pump-Pulse Brillouin optical time domain analysis) optical fiber sensor with high spatial resolution. A series of numerical analyses using non-linear FE models were also made to study the shear force transfer mechanism and crack response based on the test results. Test results show that the CFRP bar increases the shear strength and stiffness of the large diameter headed-stud shear connection, and it has equivalent reinforcing effects on the stud shear capacity as the commonly used steel bar. The embedded CFRP bar can also largely improve the shear force transfer mechanism and decrease the tensile stress in the transverse direction. The parametric study shows that low content steel fibers could delay the crack initiation of slab around the large diameter stud, and the CFRP bar with normal elastic modulus and the standard reinforcement ratio has good resistance to splitting crack growth in headed stud shear connectors.

Analysis of a Symmetric Active Cell Balancer with a Multi-winding Transformer

  • Jeon, Seonwoo;Kim, Myungchin;Bae, Sungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1812-1820
    • /
    • 2017
  • This paper analyzes a symmetric active cell balancer for a battery management system. The considered cell balancer uses a forward converter in which the circuit structure is symmetric. This cell-balancing method uses fewer switches and is simpler than the previously proposed active cell-balancing circuits. Active power switches of this cell-balancing circuit operate simultaneously with the same pulse width modulation signals. Therefore, this cell-balancing circuit requires less time to be balanced than a previous bidirectional-forward-converter-based cell balancer. This paper analyzes the operational principles and modes of this cell balancer with computer-based circuit simulation results as well as experimental results in which each unbalanced cell is equalized with this cell balancer. The maximum power transfer efficiency of the investigated cell balancer was 87.5% from the experimental results. In addition to the experimental and analytical results, this paper presents the performance of this symmetric active cell-balancing method.

KSTAR 중성빔 입사(NBI) 장치 배기계통 설계 (Design of the vacuum pumping system for the KSTAR NBI device)

  • 오병훈;인상렬;조용섭;김계령;최병호
    • 한국진공학회지
    • /
    • 제8권4B호
    • /
    • pp.548-555
    • /
    • 1999
  • The NBI (Neutral BGeam Injection) System for the Korea Superconducting Tokamak Advanced Research (KSTAR) is composed of ion sources, neutralizers, bending magnets, ion dumps, and calorimeter. The vacuum chamber, in which all of the beam line components are enclosed, is composed of differential pumping system for the effective transfer of the neutral beams. The needed pumping speeds of each of the divided vacuum chamber and the optimized gas flow rate ot the neutralizer were calculated with the help of the particle balance equations. The minimum gas flow rate to the ion sources for producing needed beam current (120kV, 65A, 78MW), the pressure distributions in the vacuum chamber for minimizing re-ionization loss, and the beam loss rate on the beam line components were used as the input in the calculation. Also the scenario for short pulse operation was determined by analysing the time dependent equations. It showed that beam extraction during less than 0.5 sec could be made only with TMP.

  • PDF

GA를 이용한 오일쿨러시스템의 최적 PI제어기 설계 (Optimum PI Controller Design for an Oil Cooler System Using GA)

  • 정영미;정석권
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.28-34
    • /
    • 2014
  • This paper deals with optimum PI controller design using genetic algorithm to improve control performance and robustness for an oil cooler system. The optimum PI gain was found to minimize an object function, integrated absolute error, and to satisfy control design specifications such as overshoot and settling time based on practical transfer function of the oil cooler system. The control performance and robustness were investigated by comparing indicial responses and Bode diagram analysis with respect to three kinds of PI gains obtained from different gain decision manners. Moreover, the robustness against to input disturbances, sinusoidal wave form and abrupt single pulse, was evaluated. The computer simulation results showed that the suggested optimum gain can establish desirable control performance and strong robustness with easy design process.

22.9 KV-y 배전선로 통신 유도장해전압(RIV)감소 대책에 관한 연구 (A study on radio interference voltage(RIV) reduction of 22-9 KV-y distribution line)

  • 전영갑;선종호;조국희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1670-1674
    • /
    • 1998
  • Now and then there are many electrical accidents between cable and line post insulator which is degraded by long time using, causing leakage current on the surface of insulator. In this paper it is denied that the 22.9 KV-y distribution lines are protected by binding cover which is needed from fog or rainy moisture, surges occurring by swiching or lightening pulse. It is analyzed to investgate the unballanced transfer characteristics and reflection coefficient by using bidding cover and non-cover. It was tested the radio interference voltage in the test room. In the factory it was tested the amount of leakage current causing on the surface of insulator in the state of no load and 70(%) load.

  • PDF

22.9 KV-y 배전선로용 전선보호관 전계강도 비교실험 연구 (A study on the electric field strength of the insulation cover using 22.9 kV-y distribution line)

  • 전영갑;서길수;차기식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1871-1873
    • /
    • 2000
  • There are many electrical accidents between bare wire and line post insulator which is degraded by long time using, causing leakage current on the surface of insulator. In this paper it is presented that the 22.9 Kv-y distribution lines are protected by binding cover which is needed from fog or rainy moisture, surges occurring by switching or lightening pulse. It is analyzed to investigate the unbalanced transfer characteristics and reflection coefficient by using binding cover and non-cover. It was tested the radio interference voltage in the test room and electric field strength by calculation between binding cover and non-cover. In the factory the leakage current causing on the surface of insulator was tested in the state of light load and heavy load.

  • PDF

ERA 부분방전 측정시스템의 측정불확도개선 (Measurement uncertainty Improvement of ERA PD measuring system in teat laboratory)

  • 허종철;김위영;김석수;오창수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1509-1510
    • /
    • 2006
  • ERA PD measuring system has been using for partial discharge evaluation of power appratus in test laboratories. So, the measurement uncertainty of PD measuring system (ERA), such as PD pulse calibrator rise and fall time, sacle factor(k) and linearity, transfer impedance etc, is very important factor of test result in test laboratory. In this paper, we describe tracebility and uncertainty improvement of PD measuring system in test laboratory based on IEC 60270.

  • PDF