• Title/Summary/Keyword: pulse test

Search Result 1,177, Processing Time 0.025 seconds

The Healing Effects of Concentration Meditation(CM) on Mind-Body - Focusing on Meditation of Dhammakaya Temple - (집중명상(Concentration Meditation:CM)이 심신치유(心身治癒)효과에 미치는 영향 -태국 담마까야(Dhammakaya)사원 명상법 중심으로-)

  • Seo, Byung-Chan
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.2
    • /
    • pp.534-546
    • /
    • 2020
  • The purpose of this study is to prove the positive effect of mind and body healing through the modified meditation method of Southern Buddhism as a systematic practice to concentrate or empty consciousness of the Buddhist temple in Dhammakaya, Thailand. To investigate the effects of the program on the participants, the experimental measurement tools in this study include the Immeasurable scale, spirituality scale, simple mental test scale, and blood pressure scale, pulse meter, thermometer, and recorder. When the measured values were compared with the corresponding t-test, there were some differences before and after the measurements based on the significance probability p <0.05. As a result, there was a significant correlation between spiritual support scale and the Immeasurable scale. In addition, the results of analyzing the data through interviews showed that the body and physiologically effective concentration was well after the meditation experience, and the intention to actively utilize this meditation method was confirmed. In this study, it was confirmed that there was a positive effect of the Samata practice method of Concentration meditation(CM), and thus the theoretical and experimental effects of intensive meditation were presented. I hope that these studies will accumulate and follow-up studies will be conducted through intensive meditation as a healing effect.

Experimental study for removing silver sulfide from silver objects by Nd:YAG laser cleaning (은제품의 황화은 부식층 제거를 위한 Nd:YAG 레이저클리닝 실험 연구)

  • Lee, Hyeyoun;Cho, Namchul
    • Journal of Conservation Science
    • /
    • v.30 no.1
    • /
    • pp.95-101
    • /
    • 2014
  • Silver objects tarnish with black from reaction with sulfurous acid or hydrogen sulfide of atmospheric. Blackening of silver objects results from formation of silver sulfide($Ag_2O$) on the surface. Silver sulfide usually is usually removed by conservation treatment. There are several cleaning methods such as chemical, electrochemical and micro-abrasion cleaning, but all of them consume silver. This study investigated the safe and effective parameter of laser cleaning by test on silver coupons. Laser cleaning is a selective process for the removal of specific substances. At first, laser cleaning applied to plain silver coupons, which were not corroded, to find out the safe range of laser energy density. From results, plain silver coupons were not changed at 1064nm below $4.00J/cm^2$ and at 532nm below $2.39J/cm^2$. The corrosion layer(silver sulfide) of artifical corroded silver coupons was removed at 1064nm with $2.39J/cm^2$ by 5~10 pulses and at 532nm with $1.19J/cm^2$ by 5~10 pulses. The removal thickness of corrosion layer was about 13-25nm per a laser pulse using AES analysis. In addition, laser cleaning tested the tarnish silver rings based on the results of silver coupons. As a result of test, the black surface were clean successfully and gave luster of silver, which showed the application possibility of laser cleaning for silver objects.

Comparison of Motor Fitness of Cerebral Palsy Chidren with normal throug Phyisical Fitness Diagnosis Evaluation (체력진단 평가를 통한 뇌성마비 아동과 정상아동의 운동능력 비교연구)

  • Lee Kang-Jun;Park Rae-Joon;Kim Jong-Yul
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.101-112
    • /
    • 2000
  • The aim of this study is to compared the cerebral palsy children with normal children in the exercise and cardio vascular ability after this study as the fundamental data fer mating programs for the cerebral palsy children. The test of this study is about twenty girls, the control group of the normal children(n=10) and the experiment group of cerebral palsy children(n=10). They were studied in four aspects which were the anthropometry, the medical check in the rest, the physical fitness or exercise roads test and the change of the target heart rate during exercise. The result were as follows : 1. The characteristic of the physical type : The control group is higher than the experiment group in the standing height and the body weight but their's little difference between them (p<0.05). The control group is lower than the experiment group in the body fat. 2. The characteristic of the medical check in the rest : The control group is higher than the experiment group in the vital capacity and flood expiratoryvolume one second. The control group is higher that the experiment group in the blood pressure of systolic and Diastolic. There's little difference between them(p<0.01). The control is lower than the experiment group in the heart pulse rate. There's little difference between them(p<0.005). 3. The characteristic of basic physical strength evaluation : The experiment group is the lowest dynamic muscular endurance, balance, agility and endurance which need to move the body with weight. The control group is much higher than the experiment group in the flexibility and muscle strength(Back strength). There's no difference between them(p<0.05). 4. The characteristics of the exercise stress last : The control group is higher than the experiment group in the endurance, the maximum of oxygen intake, endurance level and the out take of calory. There's little difference between them(p<0.01). 5. The characteristic of the change of the target heart rate during exercise : The control group is lower than the experiment group exchange of target heart rate, There's no difference them.

  • PDF

A Parametric Study of Pulsed Gamma-ray Detectors Based on Si Epi-Wafer (실리콘 에피-웨이퍼 기반의 펄스감마선 검출센서 최적화 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Jeong, Sang-Hun;Kim, Jong-Yeol;Cho, Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1777-1783
    • /
    • 2014
  • In this paper, we designed and fabricated a high-speed semiconductor sensor for use in power control devices and analyzed the characteristics with pulsed radiation tests. At first, radiation sensitive circular Si PIN diodes with various diameters(0.1 mm ~5.0 mm) were designed and fabricated using Si epitaxial wafer, which has a $42{\mu}m$ thick intrinsic layer. The reverse leakage current of the diode with a radius of 2 mm at a reverse bias of 30 V was about 20.4 nA. To investigate the characteristic responses of the developed diodes, the pulsed gamma-radiation tests were performed with the intensity of 4.88E8 rad(Si)/sec. From the test results showing that the output currents and the rising speeds have a linear relationship with the area of the sensors, we decided that the optimal condition took place at a 2 mm diameter. Next, for the selected 2 mm diodes, dose rate tests with a range of 2.47E8 rad(Si)/sec to 6.21E8 rad(Si)/sec were performed. From the results, which showed linear characteristics with the radiation intensity, a large amount of photocurrent over 60mA, and a high speed response under 350ns without saturation, we can conclude that the our developed PIN diode can be a good candidate for the sensor of power control devices.

A Study on the Effect which the Method of Deep Breathing with the Use of Incentive Spirometer has on the function of pulmonary Ventilation - In Upper Abdominal Operation Patients - (Incentive Spirometer를 사용한 심호흡 방법이 폐환기 기능에 미치는 효과에 관한 연구 -상복부 수술 환자를 대상으로-)

  • 김종혜;변영순
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.268-280
    • /
    • 1991
  • The nursing intervention for the prevention of the pulmonary complication and of the function lowering of pulmonary ventilation which emerge with high generation frequency during the nursing of operation patient is necessary for performing the qualitative nursing for operation patient. So, this researcher tried this study so as to obtain the data which can be utilized for the trial of nursing intervention, by grasping the effect that the deep breathing with Incentive Spirometer has on the function of pulmonary ventilation, analysing the factor to have influence on the function of pulmonary ventilation, and applying the effective method of deep breathing to the clinic. By making 42 patients who underwent the operation of upper abdomen after admitting G Hospital in Seoul from Mar. 7, 1991 to Apr.30, 1991 as the object, they were classified into the experiment group that the deep breathing was made with the use of Incentive Spiromenter and the comparison group that the deep breathing exercise was made without the use of Incentive Spirometer. And then, by measuring Tidal Volume and Forced Vital Capacity with Respirometer and $O_2$ Saturation with Pulse Oximeter at preoperation postoperation 24 hours, 72 hours, and 120 hours data were collected. The collected data were analyzed with of, average, standard deviation, x$^2$-test, t-test and ANOVA by SPSS. The result of this study is as follows : 1. As for the hypothesis that the function of pulmonary ventilation at postoperation 24 hours, 72 hours and 120 hours will be better in the experiment group that the deep breathing was made with the use of Incentive Spirometer, in comparison with the comparison group that deep breathing was made without the use of Incentive Spirometer, experiment group and comparison group didn't show the significant difference in Tidal Volume, Foreced Vital Capacity and $O_2$ Saturation at postoperation 24 hours and 72 hours. But experiment group and comparison group showed the significant difference in Tidal Volume at postoperation 120 hours (p<0.01). So, this hypothesis was supported partially. 2. The variables that there were the significant differences about the function of pulmonary ventilation in experiment group at postoperation 24 hours stastically were smoking existence (p<0.05), and the variables that there were not significant differences about the function of pulmonary ventilation were distinction of sex, age, anesthetic duration, smoking extent, body weight, surface area of body, existence of narcotic use, regular exercise existence, and past experience existence of respiratory disease. As above result, it appeared that the method of deep breathing with the use of the Incentive Spirometer is more effective for the function recovery of pulmonary ventilation, in comparison with the deep breathing without use of Incentive Spirometer and that smoking existence was the factor to have influence on the function of pulmonary ventilation. In the aspect of clinic, the trial of nursing intervention of deep breathing with use of Incentive Spirometer is expected. And, in the aspect of study, the study through various operative site patients about the effect of Incentive Spirometer use at the clinic will have to be confirmed.

  • PDF

Anodic Stripping Voltammetric Determinations of Zinc, Cadmium, Lead and Copper in Freshwater and Sediment (담수 및 퇴적물에 함유된 아연, 카드뮴, 납 및 구리의 산화전극 벗김 전압전류법 정량)

  • Hahn, Young Hee;Yoo, Jeong Yeon
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.4
    • /
    • pp.180-185
    • /
    • 1997
  • Zinc, cadmium, lead and copper were simultaneously determined by depositing metals at - 1.200 V vs. a Ag/AgCl(sat. KCl) reference electrode for 150 seconds on a hanging mercury drop electrode(HMDE) or a thin mercury film electrode(TMFE), followed by scanning towards anodic direction using differential pulse voltammetric(DPASV) and square wave voltammetric(SWASV) techniques. The linear calibration curves were obtained for four metal ions simultaneously determined by DPASV with a HMDE in the concentration range between 20 and 100 ppb. However, the linear calibration plots were obtained only for $Cd^{2+}$ and $Pb^{2+}$ in the simultaneous determinations with a TMFE in the concentration range up to 100 ppb using DPASV and up to 10 ppb using SWASV. DPASV with a TMFE was about 15 times more sensitive than DPASV with a HMDE for simultaneous determinations of $Cd^{2+}$ and $Pb^{2+}$. SWASV was about 5 times more sensitive than DPASV at a TMFE. Concentrations of zinc in seven different sediment samples determined by DPASV with a HMDE and inductively coupled plasma-mass spectrometry were compared, resulting with an excellent correlation coefficient of 0.9993 and with no significant difference between two methods after t-test.

  • PDF

Comparative Evaluation of Concrete Compressive Strength According to the Type of Apartment Building Finishing Materials Using Nondestructive Testing (비파괴검사법을 이용한 공동주택 마감재 종류에 따른 콘크리트 압축강도 비교평가)

  • Seong-Uk Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.32-38
    • /
    • 2024
  • In the case of apartment building, it is difficult to conduct non-destructive testing due to the actual presence of people and the dust and noise generated during the core test, so inspections are performed each time in the common area and underground parking lot, and the tests are conducted on the finishing material rather than on the concrete surface due to low-cost orders. As the process progresses, poor inspection is inevitable. In addition, the proposed formulas for strength estimation have large fluctuations depending on the differences in test conditions and environments, and even if they show the same measured value, the deviation between each proposed formula is large, making it difficult to accurately estimate strength, making it difficult to use. Accordingly, we would like to select finishing materials mainly used in apartment complexes and compare and evaluate the compressive strength of concrete according to the type of finishing material by using non-destructive testing methods directly on the finishing materials without removing the finishing materials. The reliability evaluation results of the estimated compressive strength of concrete using the ultrasonic velocity method according to the type of finishing material are as follows. The error rate between the estimated compressive strength and compressive strength derived through the ultrasonic velocity method shows a wide range of variation, ranging from 21.83% to 58.89%. The effect of the presence or absence of finishing materials on the estimated compressive strength was found to be insignificant. Accordingly, it is necessary to select more types of finishing materials and study ultrasonic velocity methods according to the presence or absence of finishing materials, and to study estimation techniques that can increase reliability.

Early Response of Cardiopulmonary Exercise Test(CPET) in Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Radiation (방사선 치료 후 폐암환자의 운동부하 심.폐 기능의 초기변화)

  • Shin, Kyeong-Cheol;Lee, Deok-Hee;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • Background : Patients with locally advanced non-small cell lung cancer are often treated with radiation alone or in combination with chemotherapy. Both modalities have a potentially damaging effect on pulmonary function. In order to examine changes in the cardiopulmonary exercise function of patients with locally advanced non-small cell lung cancer before and after conventional radiotherapy, we conducted a prospective study involving patients with such cancer, that had received radiation therapy. Method : Resting pulmonary function test, thoracic radiographic finding and cardiopulmonary exercise test(CPET) were assessed prior to and 4 weeks following radiation therapy in 11 male patients with locally advanced non-small cell lung cancer. Patient with endobronchial mass were excluded. Results : The forces vital capacity (FVC), forced expiratory volume in 1 second ($FEV_1$ and maximal voluntary ventilation (MVV) did not decreased between before and 4 weeks after radiation but the diffusing capacity (DLCO) had decreased by 11% 4 weeks after radiation, which was not statistically significant. No changes in maximal oxygen consumption ($VO_2$max), carbon dioxide production ($VCO_2$), exercise time and work load were attributed to radiation therapy. Follow up cardiopulmonary exercise testing revealed unchanged cardiovascular function, ventilatory function and gas exchange. No difference in cardiopulmonary exercise test performance was observed between pre- and post-radiation. Conclusion : Cardiopulmonary exercise function did not decrease within the short-term after the radiation of patients with locally advanced non-small cell lung cancer.

  • PDF

The Effect of Aerobic Exercise on Body Composition, Cardiopulmonary Function, Serum Lipid and Antioxidants of Obese College Female Students (에어로빅운동이 비만여대생의 신체조성, 심폐기능, 혈청지질 및 항산화물질에 미치는 영향)

  • Jung Eun-Sook;Park Hyeong-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.1
    • /
    • pp.125-141
    • /
    • 1998
  • The purpose of this research is to analyze the effects of aerobic exercise on body composition, cardiopulmonary function, serum lipid level and antioxidants of obese and normal college female students. The subject group was made up of 13 normal students (below 30% body fat ratio) and 12 obese students (above 30% body fat ratio). After a pretest, the subjects were given an 8-week aerobic program. Then the subjects were given a posttest and analyzed of body composition, serum lipid level, antioxidants and cardiopulmonary function after the 6th and the 8th week of the program. The program schedule was made up of 4 days per week, 60 minutes per day. Test includes B.W., subscapular and triceps subcutaneous fat thickness, change of respiratory gas, and two blood sampling before treadmill exercise and post all out state, which analyzed serum lipid and antioxidants. The subjects performed treadmill exercise starting with 4km/hr of walking and then gradually increase the speed of 1km/hr per minute until all out state. The obtained data were analyzed using SAS program. The statistical methods employed here were one-way ANOVA with repeated measure, Duncan Multiple range test, paired-t test and t-test. The test results and conclusion of this research were as follows. 1. The effects of aerobic exercise on body composition were as follows ; Percent body fat was significantly reduced 6 weeks after the program and lean body mass was significantly increased 8 weeks after the program in both groups(obese group: F=3.44 P=.044, normal group: F=3.30 P=.048). subscapular skinfold of the obese group showed a remarkable decrease after the 6th week(F=4.33 P=.021) triceps skinfold of the normal group showed a remarkable decrease after the 6th and the 8th week(F=4.55 P=.017) compared with readings before the aerobic program, the aerobic program made a bigger difference concerning body fat, lean body mass, subscapular skinfold in the obese group than in the normal group(t=2.41 P=.024, t=2.40 p=.025, t=2.43 p=.028). 2. The effects of aerobic exercise on cardiopulmonary function were as follows ; Maximal $O_2$ uptake/kg was significantly increased 6 weeks after the program in the obese group(F=3.20 P=.054), but not much difference was observed in the normal group. Maximal pulse rate was significantly reduced in both groups after 6 weeks of the program(obese group: F=2.77 P=.087, normal group: F=7.17 P=.001). 3. The effects of aerobic exercise on serum lipid level were as follows ; In a resting period, total cholesterol, Triglyceride, and LDL-cholesterol were slightly higher in the obese group than in the normal group, but HDL-cholesterol was higher in the normal group. But, with the aerobic program, total-cholesterol, Triglyceride, LDL-cholesterol were reduced gradually and HDL-choleterol got increased in both groups, but not much change was noticed in the normal group. However, in the obese group, serum HDL-cholesterol level got increased significantly(F=5.12 P=.012). 4. The effects of aerobic exercise in serum antioxidants were as follows ; In a resting period, the obese group's serum Free Radical and GSSG content were higher than the normal group's and the normal group's serum GSH content was higher than the obese group's. After 6 weeks of the aerobic program, Free Radical was reduced significantly in both groups(obese group: F=13.87 P=.000, normal group: F=18.60 P=.000) In the obese group, 8 weeks after the program, GSH was increased significantly(F=13.78, P=.000). In the normal group, 6 weeks after the program, GSH was reduced but increased again after 8 weeks(F=6.07 P=.005). Plasma GSSG was significantly increased after 8 weeks of exercise in both groups(obese group: F=19.75 P=.000, normal group: F=22.42 P=.000,) Compared with readings before the aerobic program, the aerobic program made a bigger difference serum GSH in the normal group than in the obese group(t=3.37 p=.003). As this result shows, it is known that the regular aerobic exercise improves cardiopulmonary function, body composition, serum lipid effectively and through the serum Free Radical reduction and antioxidant system activation, oxidant stress was suppressed. This effect was higher in the obese group than in the normal one. At least 6weeks exercise period need for improvement of body composition, cardiopulmonary function and activation of antioxidant system. This result suggest that improvement of serum lipid profile was needed longer than 8weeks exercise period.

  • PDF

Female External Genitalia and Urethra on MR Imaging: Optimal Pulse Sequence and Comparison of Anatomy in Premenopausal and Postmenopausal Women (여성 외부 생식기와 요도의 자기공명영상 소견: 적합한 영상기법과 폐경 전후의 해부학적 변화 비교)

  • Whang, Shin-Young;Ahn, Kyung-Sik;Sung, Deuk-Jae;Park, Beom-Jin;Kim, Min-Ju;Cho, Sung-Bum;Lee, Nam-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.146-153
    • /
    • 2011
  • Purpose : To describe normal anatomy and compare the differences of external genital organs and urethra on MR imaging in pre- and postmenopausal women. Materials and Methods : A total of 19 pre- and 18 postmenopausal healthy women underwent pelvis MR imaging at 1.5 T. Two radiologists retrospectively scored and compared the image quality of female external genitalia and urethra on axial T2-weighted images (T2WI) and axial fat-suppressed contrast-enhanced T1-weighted images (FSCE-T1WI) by using Wilcoxon signed ranks test. The radiologists compared the wall thickness or size of external genital organs and urethra on FSCE-T1WI between two groups by using Student t test. Results : Image quality was better with FSCE-T1WI than with T2WI in all subjects (p < 0.05). The vestibular bulb, clitoris and labium minor were more clearly visualized on FSCE-T1WI in premenopausal subjects rather than in postmenopausal subjects (p < 0.05). The urethra had a target-like appearance with three layers in premenopausal and postmenopausal subjects. Postmenopausal subjects were observed to have significantly smaller vaginal wall thickness, urethral wall thickness and vestibular bulb width than premenopausal subjects (p < 0.05). Conclusion : The anatomy and morphologic changes of female external genital organs and urethra were well discernible on FSCE-T1WI.