• 제목/요약/키워드: pulse sensor

검색결과 541건 처리시간 0.03초

한방용(韓方用) 맥파 검출시스템 (Radial Pulse Wave Detection system for the Korean Medicine)

  • 이호재;김진우;김흥오;박영배;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.66-69
    • /
    • 1991
  • This paper describes a design of transducer for non-invasively detecting pressure radial pulse wave in aterial system and a recording system that for the studing the aterial pulse diagnosis of korean traditional medicine. The mechanism of transducer is composed of sensing mechanism, pressure sensor, conditioning amplifier. The variation of radial pulse pressure in the sensing mechanism is converted to the electric signal by piezo-resistive pressure sensor and it converted to the digital signal after preprocessing via A/D converter. The converted signals inputed to the computer as data files and then it display to the monitor for waveform watching and this datas can be used as the aterial pulse diagnosis data. This system effectively detect non-differential radial pulse wave and we conside that if analizing the recorded radial pulse wave, compared each other, it can be helpful in quantify radial pulse wave diagonosis of the Korean traditional medicine.

  • PDF

어레이 압저항 센서를 활용한 체질맥 임상연구 (Clinical Study on the Sasang Constitutional Pulse Using Array Piezoresistive Sensor)

  • 이시우;주종천;김경요;김종열
    • 사상체질의학회지
    • /
    • 제18권1호
    • /
    • pp.118-131
    • /
    • 2006
  • 1. Objective Pulse diagnosis is generally applied to Traditional Oriental Medicine but not to Sasang Constitution diagnosis. Recently new pulse analyzer using array piezoresistive sensor and multi-channel robot arm developed. It reflects Oriental Medical Doctors' diagnostic processes, and its reproducibility test was done at Korea Institute of Oriental Medicine. We performed this study to set parameters diagnosing Sasang Constitution. 2. Methods One hundred thirty three subjects participated in this study. They are healty and approved this study. Before being tested with pulse analyzer, they had interview with Sasang Constitution Specialist to diagnose their Sasang Constitution. We established some useful parameters from parameters of pulse analyzer according to the Original Texts of Oriental Medicine and clinical experiences to analyze with clinical data of this study. 3. Results (I) There is a significant difference in pre-dicrotic notch time among all parameters of pulse analyzer in Sasang Constitution groups(P=0.047). (2) There is a significant difference in maximum pulse pressure in 33 to 48 year Sasang Constitution groups(P=0.010). (3) There is a significant difference in frequency width in 17 to 32 year Sasang Constitution groups(P=0.002). (4) There is a significant difference in CFS value in groups which OMD diagnoses; Floating & Sinking pulse(P=0.020). (5) There is a significant difference in pulse rate in groups which OMD diagnoses; Rapid & Slow pulse(P=0.000). (6) There is a significant difference in maximum pulse pressure in groups which OMD diagnoses; Deficient & Solid pulse(P=0.000). 4. Conclusions Analyzing parameters in each Sasang Constitution group, we found it shows significant difference in maximum pulse pressure and corresponding tendency in coefficient of floating & sinking pulse with theories of Sasang Consti-tutional Medicine. As we accumulate more clinical data, we will establish algorithm to diagnose Sasang Constitution using a pulse analyzer.

  • PDF

FBG를 이용한 맥진 시스템 개발 (Development of the pulse analyzing system using FBG)

  • 전영주;이전;유현희;이재훈;이시우;김종열
    • 한국한의학연구원논문집
    • /
    • 제13권3호
    • /
    • pp.105-110
    • /
    • 2007
  • This work reports the pulse diagnosis system using FBG sensors which can display pulse signals detected while oriental medical doctors are conducting pulse diagnoses and simultaneously pressing the sensors by three fingers. Each optical fiber has five FBG sensing units fabricated in 2 mm width and 2 mm inter-sensor spacing. Three optical fibers with the FBG units in the parallel line configuration are then placed on each finger-pressing region and thus overall 9 fibers are used for the pulse measurements on the so-called "chon", "gwan", and "ch대k". A fixture holding the optical fiber arrays is able to adjust the height of the FBG sensing units while placing the fibers on the wrist. The pulse signals detected by the FBG sensors from chon, kwan, and chuk have been analyzed using 4 channel spectrum analyzer connected to the optical fibers. The measured pulse signals exhibit variations due to the nonuniform pressure distributions applied. resulting in the differences in the detected pulse signals between fiber lines. However. this work is the first step towards objective and quantitative analyses of the pulse diagnosis in oriental medicine which has traditionally been performed on subjective basis. Future works will be devoted to improving sensor stability, developing the way applying pressure and algorithms reporting the objective classification of the pulse status from systemic measurements using the sensors instead of relying on the clinicians' diagnoses subjectively performed. A successful pulse diagnosis system emerging in the future is expected to contribute to education as well as promoting pulse diagnosis in oriental medicine to the scientific research area.

  • PDF

PDMS(Polydimethylsiloxane)의 열경화조건에 따른 크랙 이용 센서 감도 최적화 (Optimization of Crack Based Sensor Sensitivity According to Thermal Curing Conditions of PDMS (Polydimethylsiloxane))

  • 황인주;윤상석;최용환
    • 열처리공학회지
    • /
    • 제36권4호
    • /
    • pp.237-241
    • /
    • 2023
  • Recently, research on flexible sensors for personal health management has been gaining attention. In this study, we fabricated a crack-based flexible sensor in thin film form to measure the pulse on the wrist. We evaluated the characteristics of the sensor based on the curing conditions of the PDMS (Polydimethylsiloxane) film to optimize the sensor's gauge factor. The modulus of PDMS varies depending on the curing conditions. In this case, the modulus of PDMS has a significant influence on crack formation, leading to changes in the sensitivity of the sensor. This study examined the changes in the gauge factor associated with these variations.

Design of Digital Systems for Web -based Pulse Diagnosis Database

  • Lee, Junyoung;Lee, Sungjae;Lee, Myoungho;Kim, Jeonghoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.181.4-181
    • /
    • 2001
  • In this study, we have developed the digital hardware system which performs signal processing necessary for the filtering to eliminate noises by inputting pulse wave signals from the sensor group. With a view to obtain clinically effective information, we analyzed structural elements of pulse waveform and, thus, conducted a systematic classification. What is more, this study has conducted researches in the web-based diagnosis data management system of pulse waveform as well as the method of transmitting the data of pulse waveform. In order to set the standard for the documents of the pulse ...

  • PDF

맥박센서를 이용한 졸음방지운전시스템에 관한 연구 (A Study on the Drowsy Driving Prevention System using the Pulse Sensor)

  • 박춘명
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.577-578
    • /
    • 2016
  • 본 논문에서는 차량운행 시 일어날 수 있는 졸음운전 사고를 예방하기 위해 맥박 센서를 이용하여 차량 안전시스템 구성을 제안하였다. 제안한 차량 안전시스템은 운전자의 졸음운전 상태를 판단하여 경보를 알리고, 이를 이용하여 운전자는 돌발적인 상황이나 위험상황을 미리 인지하여 직접적인 사고 및 2차 사고를 예방 할 수 있다.

  • PDF

이중 입구형 맥동관 냉동기에서의 압력 파형 측정 (Pressure Measurement in Double Inlet Pulse Tube Refrigerator)

  • 정제헌;남관우;정상권;정은수
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.390-396
    • /
    • 2004
  • A double-inlet pulse tube refrigerator was fabricated as a U-shape with $\Phi$19.0 mm${\times}$125 mm regenerator packed by #200 stainless steel mesh and $\Phi$12.7 mm${\times}$125 mm pulse tube. A pressure sensor was installed at the inlet of the regenerator and a differential pressure sensor was installed across the bypass. Amplitude of the pulsating pressure was independent of the opening of the orifice and the bypass valves. Helium flow through the orifice and the bypass was calculated based on the measured pressure. Energy loss through the orifice and the bypass was evaluated with the measured pressure and the calculated helium flow rate. The energy loss, which is equivalent to the refrigeration capacity at the cold end of the ideal pulse tube refrigerator, was mainly generated through the orifice. It was proportional to the opening of the orifice valve, but the real refrigerator displayed the best performance at the optimized opening of the orifice valve. This optimized performance of the tested pulse tube refrigerator can be explained by additional refrigeration losses. As an example, the shuttle heat transfer loss of the pulse tube was calculated from the measured experimental data.

Compact and versatile range-finding speedometer with wide dynamic range

  • Shinohara, Shigenobu;Pan, Derong;Kosaka, Nozomu;Ikeda, Hiroaki;Yoshida, Hirofumi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.158-161
    • /
    • 1995
  • A new laser diode range-finding speedometer is proposed, which is modulated by a pair of positive and negative triangular pulse current superimposed on a dc current. Since a target velocity is directly obtained form a pure Doppler beat frequency measured during the non-modulation period, the new sensor is free from the difficulties due to the critical velocity encountered in the previous sensor. Furthermore, the different amplitude of the two triangular pluses are so adjusted that the measurable range using only one laser head is greatly expanded to 10cm through 150cm, which is about two times that of the previous sensor. The measurement accuracy for velocity of .+-.6mm/s through .+-.20mm/s and for range is about 1%, and 2%, respectively. Because the new sensor can be operated automatically using a microcomputer, it will be useful for application of a 3-D range image measurement of a slowly moving object.

  • PDF

인영(人迎)·기구비교맥법(氣口比較脈法)의 정량화(定量化)에 관(關)한 연구(硏究) (The quantitative study on the Renying·Qi mouth comparison pulse diagnosis)

  • 조명래;김무신;유충렬;최찬헌;장경선;소철호;박영배
    • Journal of Acupuncture Research
    • /
    • 제19권2호
    • /
    • pp.149-163
    • /
    • 2002
  • Objective : We have studied literatures of Renying Qi mouth comparison pulse diagnosis theory and distinguished the excess, deficiency and quick-temper of pulse as the measurement parameter of Renying Qi mouth pulse diagnosis. Methods : We have acquired pulse signals of Renying Qi mouth by using diagnostic equipment of Renying Qi mouth pulsation and estimated reappearance of pulse signals. Results : 1. The measurement parameter of Renying Qi mouth pulse diagnosis distinguishes the excess, deficiency and quick-temper of pulse through relative comparison of Renying Qi mouth. 2. When we acquired the pulse singals of Renying Qi mouth by using diagnostic equipment, the property, measuring area, bias pressure, contact or adhesion state of the sensor are considered. 3. As getting the pulse signal of Renying Qi mouth, the sensor of a sound detective mode is effective. 4. The diagnostic equipment of Renying Qi mouth pulse is assessed as being significant reappearance.

  • PDF

심전도와 맥파 신호 검출을 위한 일체형 센서 시스템의 구현 (The Development of Integrated Sensor System for Measuring Simultaneously ECG, PPG and PPW)

  • 전계록;정동근;김기련;신범주
    • 한국산학기술학회논문지
    • /
    • 제10권5호
    • /
    • pp.992-999
    • /
    • 2009
  • 심전도와 맥파를 측정함으로써 구해질 수 있는 맥파전달시간은 심혈관계의 상태를 진단하기 위한 의미 있는 지표가 된다. 그러나 맥파를 측정하는 동안 움직이거나, 측정 시에 가해지는 압력이 부정확할 경우, 잘못된 측정 결과를 얻을 수 있다. 이를 해결하기 위하여 본 논문에서는 심전도, 압력맥파 및 광전용적맥파를 동시에 측정할 수 있는 일체형 센서 시스템과 심전도를 지속적으로 측정할 수 있는 금속 전극을 개발하였으며, 실험을 통해 일체형 센서시스템 및 금속 전극의 유용성을 입증하였다.