• 제목/요약/키워드: pulse pattern

Search Result 426, Processing Time 0.036 seconds

Development of Low Frequency Pulse MIG Welding Process for AL and its alloy (AL 및 AL합금의 저주파 PULSE MIG 용접법의 개발)

  • 최병길;이사영;이승학;천성진
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.45-48
    • /
    • 1997
  • The low frequency pulsed MIG welding process of new current waveform control to switch over unit pulse conditions (pulse current, pulse duration) in the fixed cycle was developed and its effect were investigated for aluminium and its alloy. By using this new welding process, the bead appearance having clear ripple pattern, such as TIG welding bead can be obtained and the gap tolerance of lap and butt welding joint can be expanded.

  • PDF

A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels (5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구)

  • Kown, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

Cold-Heat and Excess-Deficiency Pattern Identification Based on Questionnaire, Pulse, and Tongue in Cancer Patients: A Feasibility Study (암 환자 대상 설문지, 맥진기, 설진기 결과를 활용한 한열허실변증에 대한 예비 연구)

  • Choi, Yujin;Kim, Soo-Dam;Kwon, Ojin;Park, Hyo-Ju;Kim, JiHye;Choi, Woosu;Ko, Myung-Hyun;Ha, Su-Jeung;Song, Si-Yeon;Park, So-Jung;Yoo, Hwa-Seung;Jeong, Mi-Kyung
    • The Journal of Korean Medicine
    • /
    • v.42 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • Objectives: This pilot study aimed to evaluate the agreement between traditional face-to-face Korean medicine (KM) pattern identification and non-face-to-face KM pattern identification using the data from related questionnaires, tongue image, and pulse features in patients with cancer. Methods: From January to June 2020, 16 participants with a cancer diagnosis were recruited at the one Korean medicine hospital. Three experienced Korean medicine doctors independently diagnosed the participants whether they belong to the cold pattern or not, heat pattern or not, deficiency pattern or not, and excess pattern or not. Another researcher collected KM pattern related data using questionnaires including Cold-Heat Pattern Identification (CHPI), tongue image analysis system, and pulse analyzer. Collected KM pattern related data without participants' identifier was provided for the three Korean medicine doctors in random order, and non-face-to-face KM pattern identification was carried out. The kappa value between face-to-face and non-face-to-face pattern identification was calculated. Results: From the face-to-face pattern identification, there were 13/3 cold/non-cold pattern, 4/12 heat/non-heat pattern, 14/2 deficiency/non-deficiency pattern, and 0/16 excess/non-excess pattern participants. In cold/non-cold pattern, kappa value was 0.455 (sensitivity: 0.85, specificity: 0.67, accuracy: 0.81). In heat/non-heat pattern, the kappa value was 0.429 (sensitivity: 0.75, specificity: 0.72, accuracy: 0.75). The kappa value of deficiency/non-deficiency and excess/non-excess pattern was not calculated because of the few participants of non-deficiency, and excess pattern. Conclusions: The agreement between traditional face-to-face pattern identification and non-face-to-face pattern identification seems to be moderate. The non-face-to-face pattern identification using questionnaires, tongue, and pulse features may feasible for the large clinical study.

A clinical study of atopic dermatitis patients as measured by Pulse diagnostic apparatus (맥진기(脈診器)를 이용한 아토피 피부염 환자의 임상적 고찰)

  • Shin, Yoon-Jin;Kim, Yoon-Bum;Yoon, Sang-Heub
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.21 no.2
    • /
    • pp.112-119
    • /
    • 2008
  • Objective : The quantification of pulse diagnosis is an important subject utilizing as a modernization of Oriental medical diagnosis and as a basic data for collaborative access between East and West Medicine. This study was to observe the tendency of pulse diagnosis in atopic dermatitis patients as measured by pulse diagnostic apparatus. Methods : We did pulse diagnostic test about 11 new outpatients who had visited the department of ophthalmology, otolaryngology, dermatology in Kyunghee oriental medical center from March 1, 2007 to October 31, 2007 and had atopic dermatitis. Results : The results were as follows. 1. Among the 11 outpatients, the total number of male patients were 5 and female patients were 6, and the age distribution, the most frequently visited age groups were 10-19 years old and 20-29 years old(each 4 patients). 2. The most common period of onset to first examination were 3 years${\leq}$ (7 patients). 3. There were 8 patients who had emphasized T-wave. 4. There were 7 patients who had repeated pulse wave pattern. Conclusion : In 11 cases who had atopic dermatitis, 8 patients had emphasized T-wave and 7 patients had repeated pulse wave pattern.

  • PDF

A Detection Algorithm for Pulse Repetition Interval Sequence of Radar Signals based on Finite State Machine (유한 상태 머신 기반 레이더 신호의 펄스 반복 주기 검출 알고리즘)

  • Park, Sang-Hwan;Ju, Young-Kwan;Kim, Kwan-Tae;Jeon, Joongnam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.85-91
    • /
    • 2016
  • Typically, radar systems change the pulse repetition interval of their modulated signal in order to avoid detection. On the other hand the radar-signal detection system tries to detect the modulation pattern. The histogram or auto-correlation methods are usually used to detect the PRI pattern of the radar signal. However these methods tend to lost the sequence information of the PRI pulses. This paper proposes a PRI-sequence detection algorithm based on the finite-state machine that could detect not only the PRI pattern but also their sequence.

The Diagnosis of Treeing Breakdown Using Simultaneous Detection of Electrical Charge and Acoustic Emission Pulse of Partial Discharge (부분 방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단)

  • 김성홍;박재준;김재환
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.247-254
    • /
    • 1997
  • Internal voids in insulators give rise to partial discharge, which causes a local breakdown and even entire insulation breakdown. Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with an artificial needle shaped void by the charge of discharge and acoustic emission pulse in each phase angle area at the same time. We analyzed the .PHI.-QA-t pattern and .PHI.-AEA-t pattern using statistic operators such as pulse magnitude, pulse number, skewness, kurtosis. Therefore, the relation between the charge of discharge and acoustic emission pulse will be helpful to predict the breakdown just before the breakdown occur.

  • PDF

Auxiliary Address Pulse Driving Scheme for Improving Luminance and Luminous Efficiency in 42-inch WVGA Plasma Display Panel

  • Park, Ki-Hyung;Lee, Eun-Cheol;Cho, Ki-Duck;Tae, Heung-Sik
    • Journal of Information Display
    • /
    • v.5 no.1
    • /
    • pp.16-21
    • /
    • 2004
  • The effects of an auxiliary address pulse driving scheme, in which an auxiliary short pulse is applied to the address electrode during a sustain-period, were examined under the various image patterns of the 42-inch WVGA ac-PDP. When the auxiliary address pulse driving scheme was applied, the luminance of the red, green and blue cells were measured respectively. And the luminance, luminous efficiency, and current were measured under the full-white pattern of the 42-inch ac-PDP. As a result, the luminance of blue cells was improved approximately by 17 %, whereas the luminous efficiency of the full-white pattern was improved approximately by 34 % without a misfiring discharge in comparison with conventional driving scheme.

A Study On PIN Pulse Pattern Optimization In The Space Vector Notation Using Pulse Frequency Modulation (펄스 주파수 변조 방법을 이용한 공간 벡터 PWM 펄스 패턴최적화 기법에 관한 연구)

  • Jeon, Hi-Jong;Son, Jin-Geun;Kim, Dong-Joon;Lee, Suck-Tae;Choi, Woo-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.307-312
    • /
    • 1994
  • In this investigation the PFM(Pulse Frequency Modulation} will be used for optimizing PWM inverter pulse pattern. In traditional the pulse frequency of PWM is kept const. But modulated PWM's frequency in this study, the sinusoidal inverter's performance should be improved. The PWM pulsepatterns are definitely controlled so that the time-integral function of the voltage vectors in the space vector notation may show a circular locus. Further, performance index will be minimized because of minimizing distortion of output current. Finally, we will implement itusingsingle-chip microprocessor.

  • PDF

Study on Cold-Heat Pattern Identification in Hypertensive Patients with Antihypertensive Agents (항고혈압제제를 복용 중인 성인 고혈압 환자의 한열 특성에 관한 연구)

  • Yang, Na-Rae;Han, Chang-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.3
    • /
    • pp.267-277
    • /
    • 2013
  • Objectives : The aim of this study was to investigate the correlation between Cold-Heat pattern tendency and demographic traits, physical character, and vital signs in hypertensive patients taking anti-hypertensive agents. Methods : 28 hypertensive patients 30 to 69 years old were recruited. We assessed their general characteristics, physical characteristics (height, weight, waist circumference, etc.), vital signs without respiratory rate (blood pressure, pulse rate, temperature) and administered a Cold-Heat pattern questionnaire. After that, we analyzed statistical data on separate groups according to Cold-Heat characteristics or other criteria. Results : 1. Heat group patients had statistically higher scores in waist, body mass index (BMI), waist circumference and pulse rate. 2. Over weighted group patients had statistically lower scores in cold Pattern Identification. 3. Higher BMI group (above 23/25) patients had statistically significantly higher Heat scores and lower Cold scores, higher waist circumference group patients had lower Cold scores. Conclusions : From the above result in hypertensive patients taking hypertensive agents, Heat group had a obesity tendency and the inverse is also valid. Later, progressed study based on more samples and varied data will contribute to diagnosis the Cold-heat Pattern identification in hypertensive patients.

Development of Clinical Protocol on the Correlation Between Disease Cause Pattern Identification and Pulse Wave Variables (병인변증과 요골동맥 맥상파의 특성 파악을 위한 탐색적 관찰 연구 : 임상시험 프로토콜 개발)

  • Kim, Jihye;Yu, Hana;Ku, Boncho;Kim, Hyunho;Kim, Jongyeol;Jeon, Youngju
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.662-667
    • /
    • 2014
  • The purpose of this clinical study is to develop structured clinical trial protocol and guideline for improvement of safety, useful and effective of pulse diagnosis devices. As a first step, papers on pulse diagnosis and pulse diagnosis devices from 2001 and 2013 were systematically reviewed. In the next step, we have collected the opinions from the specialists, companies, and statistician in pulse diagnosis to evaluate the current condition, the state and problem of domestic clinical trial cases of pulse diagnosis device. And we have to created protocol and case report form (CRF) in regards to site condition and characteristics of pulse diagnosis devices, and showed the guideline of eligibility criteria, operation process, investigation items, evaluation items and so on. This clinical protocol will become a basic information for a researcher in designing or performing a clinical study of pulse diagnosis devices, and be used as a useful material during acquisition of good clinical data. Furthermore, we hope to enhance the invigoration of pulse diagnosis clinical trials and the performance improvement of pulse diagnosis devices.