• Title/Summary/Keyword: pulse input method

Search Result 242, Processing Time 0.03 seconds

A Pulse Frequency Control of Single-switch Three-phase ZCS Buck Rectifiers (단일 스위치 3상 ZCS 강압형 정류기의 펄스 주파수 제어)

  • 송중호;김용덕;이동윤;최익;최주엽;유지윤
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.82-90
    • /
    • 1999
  • A pulse frequency control method for single-switch three-phase buck rectifiers is comprehensively studied in this paper. The proposed pulse frequency control method leads the three-phase buck rectifier to a high performance system that can draw the nearly sinusoidal input-line currents. The simulated and experimental results demonstrate that the system provides low total harmonic distortion of the input-line currents, high-power factor, and good output voltage regulation against load change.

Static Characteristics Investigation of LPM According to Input Current Waveforms (입력 전류 파형에 따른 LPM의 정특성 고찰)

  • 허두석;조윤현
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.409-416
    • /
    • 2004
  • This paper presents the selection method o( the input current wave forms for the thrust force ripple of linear pulse motor (LPM). We have developed and tested a prototype 2-phase 4-poles LPM with the permanent magnet and its control driver. To obtain the thrust performance curve of LPM, the performance curve at the air gap and the thrust are calculated and estimated by the analytical method on the base of the magnetic equivalent circuit and the finite element method. And, the thrust characteristics at the static operation state are analyzed and experimented with the respect to the input wave forms such as the rectangular, the triangular micro-step and the sine micro-step wave forms to investigate the thrust ripple and the vibration effects of LPM.

A Resonant Type Inverter Power Conversion Equipment for Plasma Generator (플라즈마 발생장치용 공진형 인버터 전력변환장치)

  • Kim, Ju-Yong;Suh, Ki-Young;Mun, Sang-Pil;Jung, Jang-Gun;Kim, Young-Mun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.162-165
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

The output characteristics of resonant type inverter for ozone generator (오존 발생기용 공진형 인버터의 출력특성)

  • Kang, W.J.;Lee, H.W.;Suh, K.Y.;Kwon, S.K.;Mun, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.139-142
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for Ozone Generator are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

A study on power system for plasma sterilization (플라즈마 살균용 전원장치에 관한 연구)

  • Kang, W.J.;Kim, Y.M.;Mun, S.P.;Kwon, S.K.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.52-54
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described, For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc.. PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Resonance inverter power system for plasma sterilization effective improvement (플라즈마 살균 효과 개선을 위한 공진용 인버터 전원 시스템)

  • Kim, J.Y.;Mun, S.P.;Kim, J.S.;Kim, Y.M.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1172-1174
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Resonance Inverter Power System for Sterilization Effective Improvement of Plasma (플라즈마 살균 효과 향상을 위한 공전형 전원 시스템)

  • 김주용;문상필;정장근;이현우;서기영
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Determination of Loxoprofen Adsorption Isotherms by Frontal Analysis and Pulse Input Method (Frontal Analysis와 Pulse Input Method를 이용한 Loxoprofen의 등온흡착식 결정)

  • Lee, Eun;Park, Joon-Sub;Kim, In-Ho
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.371-375
    • /
    • 2006
  • Frontal analysis(FA) and Pulsed input method(PIM) have been frequently utilized to measure isotherm of single solute, as well as non-competitive isotherms of two solutes in chromatography(1). FA and PIM were used in this study as complementary methods to measure adsorption isotherms of loxoprofen racemate in HPLC. Prior to FA and PIM experiments, measurements of loxoprofen solubility were made at hexane/ethanol=50/50, 80/20, 95/5(v/v) with acetic acid(0.5%) for adjusting pH. The last composition(95/5) of hexane/ethanol allows us to separate loxoprofen racemate into two forms(retentate, extract). PIM and FA were used to determine the isotherms of re-and ex-loxoprofen.

The Static Characteristics Investigation of Lineal Pulse Motor According to Input Current Waveforms (입력 전류 파형에 따른 Linear Pulse Motor의 정특성 고찰)

  • Heo, Du-Suk;Kim, Kyung-Ho;Hwang, Dong-Won;Cho, Yoon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.747-749
    • /
    • 2003
  • When the input current wave forms of Linear Pulse Motor(LPM) is excited as three difference type such as the square, the rectangular and the micro sinusoidal wave, this paper is proposed the calculation of thrust on the base of magnetic equivalent circuit of LPM. The thrust is analyzed and compared by the analytical method, the F.E.M. and the experimental values. Also, to decide the input current wave for optimal operation condition, the vibration of LPM is experimented and estimated.

  • PDF

Residual Vibration Suppression of a Beam-Mass-Cart System by Input Reshaping with a Robust Inernal-loop Compensator (강인한 내부 루프 보상기를 입력성형법에 의한 유연보-부하-대차 시스템의 잔류진동 억제)

  • Park, Sangdeok;Kim, Bong-Keun;Chung, Wan-Kyun;Yeom, Yeong-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.3
    • /
    • pp.198-208
    • /
    • 2001
  • In this paper, vibration suppression of an elastic beam fixed on a moving cart and carrying a fixed or moving mass is considered. A modified pulse sequence method with RIC(Robust Internal-loop Compensator) is proposed to suppress the single model residual vibration and to get accurate positioning of the beam-mass-cart system. The performance of the proposed input preshaping method is compared with that of the previous ones through simulations and experiments. Using the proposed method, it is able to suppress the initial vibration of the beam-mass-cart system carrying a concentrated mass. Accurate PTP(point-to-point) positioning of the moving mass without residual vibration is also obtained experimentally by modifying the proposed pulse sequence method. Finally, the proposed input preshaping method is applied successfully to the system to follow square trajectories of the moving mass without residual vibration.

  • PDF