• Title/Summary/Keyword: pulse analysis

Search Result 2,086, Processing Time 0.036 seconds

A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels (5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구)

  • Kown, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

Modern Medical Scientific Study on the String Pulse (현맥의 특징에 대한 현대 의학적 고찰)

  • Ryu, Hyun-Hee;Lee, Jeon;Jeon, Young-Ju;Lee, Yu-Jung;Lee, Si-Woo;Kim, Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.535-539
    • /
    • 2008
  • Pulse diagnosis is one of the typical examination methods in traditional oriental medicine. Pulse type classification is a major element of this diagnosis. There are more than 20 pulse types which have each clinical significance. However, pulse type's indications are implicative and obscure. In this study, we reviewed string pulse which is often diagnosed in Traditional Korean Medicine by analysis of Traditional Oriental Medical Literatures and modern medical papers. String pulse is taut and stiff pulse with high tension and low softness. It appears in 'blood vessel endothelial dysfunction', 'autonomic imbalance', 'arteriosclerosis'. Persistent string pulse can bring about cardiovascular or central nervous disease.

A Pilot Study on Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer in Women with Mild Hyperemesis Gravidarum (임신오조 환자의 맥파 분석 예비 연구)

  • Bae, Ju-Eun;Yoon, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.4
    • /
    • pp.21-30
    • /
    • 2015
  • Objectives : The purpose of this study was to analyze the characteristics of the pulse energy in women who complained mild hyperemesis gravidarum. Methods : We analyzed the values of pulse energy on 14 patients who suffered mild hyperemesis gravidarum. The patients’ symptoms were assessed by PUQE (Pregnancy-Unique Quantification of Emesis scale). Statistical analysis was performed using SPSS 18.0 for window program, one way ANOVA, pearson correlation coefficient. Results : The results were as follows. 1. There were no statistically significant pulse energy differences. 2. The Chon pulse energy showed negative correlations with each Kwan and Cheok. 3. PUQE score showed positive correlations with right Chon pulse energy and negative correlations with right Kwan pulse energy. Conclusions : The result suggested that PUQE score changes be positive related with spleen pulse energy and negative related with lung pulse energy.

Measurement and Analysis of Pulse Wave using Clip Type Pulsimeter Equipped with a Permanent Magnet and a Hall Device (영구자석과 홀소자로 구비된 집게형 맥진기를 이용한 맥진파형 측정과 분석)

  • Son, Il-Ho;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.3
    • /
    • pp.104-107
    • /
    • 2011
  • We measured signals at the "Guan" region of a radially arterial pulse using the prototype of a clamping pulsimeter equipped with a Hall effect device, which is passed signals through the voltage detecting hard ware system. The important four different measuring times of the period, systolic, reflective, and notch peaks for a temporally pulse signal are obtained and compared each other from the analysis for an arbitrary pulse wave of one position of small size permanent magnet. It is possible to measure the reproducible pulse rate and blood pressure by using the cuffless clip type pulsimeter without an unpleasant oppressive feeling due to the use of pressurization.

Analysis of Effective Optical Pulse Stream Generation using Loop Scheme (루프구조를 이용한 효율적인 광펄스 스트림 발생에 관한 분석)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1580-1584
    • /
    • 2010
  • In this paper, we made an analysis of the effective optical pulse stream generation. This is different from conventional approaches, which use fiber or waveguide delay line circuits. The optical pulse multiplication phenomenon occurs when the optical pulse's spectral width is greater than the transfer bandwidth of the coupler used. Therefore, the effective optical pulse stream generation can be controlled by using fiber couplers with different equivalent transfer bandwidths. The pulse separation spacing is controlled by number of cascaded coupler in optical loop mirror coupler scheme.

Integrated Structural Dynamic Response Analysis considering the UNDEX Shock Wave and Gas Bubble Pulse (수중폭발 충격파와 가스구체 압력파를 함께 고려한 구조물의 동적응답해석)

  • Lee, Sang-Gab;Hwon, Jeong-Il;Chung, Jung-Hoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.2 s.152
    • /
    • pp.148-153
    • /
    • 2007
  • Two typical impact loadings, shock wave and gas bubble pulse, due to UNDEX(UNDerwater EXplosion), should be considered together for the closest response analysis of structure subjected to UNDEX to a reality. Since these two impact loadings have different response time bands, however, their response characteristics of structure are different from each other. It is impossible to consider these effectively under the current computational environment and the mathematical model has not yet been developed. Whereas Hicks model approximates the fluid-structure interaction due to gas bubble pulse as virtual mass effect, treating the flow by the response of gas bubble after shock wave as incompressible ideal fluid contrary to the compressible flow due to shock wave, Geers-Hunter model could make the closest response analysis of structure under UNDEX to a real one as a mathematical model considering the fluid-structure interaction due to shock wave and gas bubble pulse together using acoustic wave theory and DAA(Doubly Asymptotic Approximation). In this study, the application and effectiveness of integrated dynamic response analysis of submerged structure was examined with the analysis of the shock wave and gas bubble pulse together.

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Load Transfer on Pulsed Power Discharge Anchors (펄스방전 확공형 앵커의 하중전이에 관한 연구)

  • Kim, Sung-Kyu;Kim, Nak-Kyung;Kim, Jae-Won;Joo, Yong-Sun;Kim, Sun-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.832-839
    • /
    • 2010
  • The pulse discharge anchor is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which is also known as pulse discharge and electric-spark technologies. The pulse discharge anchor has bulbed bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea and attached strain gauge at 10 anchors. The numerical predictions by Beam-Column analysis were compared with observed measurements in a field load test.

  • PDF

Numerical Analysis of a Double Inlet Pulse Tube Refrigerator (이중입구 맥동관냉동기의 수치적 해석)

  • Chai, W.B.;Jeong, K.S.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.501-511
    • /
    • 1995
  • A numerical model for predicting the performance of gas distrubutor type double inlet pulse tube refrigerators has been developed. The model was based on adiabatic analysis and the losses of heat exchangers and regenerator were considered. Thermodynamic behavior of working fluid within a double inlet pulse tube refrigerator was investigated and the effects of design parameters, such as valve and orifice openings, cold heat exchanger temperature, frequency and pulse tube length, on the cooling capacity and COP were shown.

  • PDF

Theoretical Study of Brillouin OTDA using Two Pulse Insets (두 대의 펄스 레이저를 사용한 Brillouin OTDA의 이론적 분석)

  • Hong, Yong-Hyun;Lee, Ho-Joon
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.3
    • /
    • pp.196-201
    • /
    • 2007
  • A theoretical study of Brillouin optical time domain analysis (BOTDA) using two pulse lasers is performed. Even though a point detection is made for a pump pulse period, the dynamic range of BOTDA using two pulse lasers is approximately 5 dB more than that of a pulse and a CW laser when the fiber length is 140 km and the Stokes power is 1 mW.