• Title/Summary/Keyword: pulse analysis

Search Result 2,090, Processing Time 0.029 seconds

Performance Analysis of Noncoherent OOK UWB Transceiver for LR-WPAN (저속 WPAN용 비동기 OOK 방식 UWB 송수신기 성능 분석)

  • Ki Myoungoh;Choi Sungsoo;Oh Hui-Myoung;Kim Kwan-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.11A
    • /
    • pp.1027-1034
    • /
    • 2005
  • IEEE802.15.4a, which is started to realize the PHY layer including high precision ranging/positioning and low data rate communication functions, requires a simple and low power consumable transceiver architecture. To satisfy this requirements, the simple noncoherent on-off keying (OOK) UWB transceiver with the parallel energy window banks (PEWB) giving high precision signal processing interface is proposed. The flexibility of the proposed system in multipath fading channel environments is acquired with the pulse and bit repetition method. To analyze the bit error rate (BER) performance of this proposed system, a noise model in receiver is derived with commonly used random variable distribution, chi-square. BER of $10^{-5}$ under the line-of-sight (LOS) residential channel is achieved with the integration time of 32 ns and signal to noise ratio (SNR) of 15.3 dB. For the non-line-of-sight (NLOS) outdoor channel, the integration time of 72 ns and SNR of 16.2 dB are needed. The integrated energy to total received energy (IRR) for the best BER performance is about $86\%$.

OVERVIEW OF KSTAR INTEGRATED CONTROL SYSTEM

  • Park, Mi-Kyung;Kim, Kuk-Hee;Lee, Tae-Gu;Kim, Myung-Kyu;Hong, Jae-Sic;Baek, Sul-Hee;Lee, Sang-Il;Park, Jin-Seop;Chu, Yong;Kim, Young-Ok;Hahn, Sang-Hee;Oh, Yeong-Kook;Bak, Joo-Shik
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.451-458
    • /
    • 2008
  • After more than 10 years construction, KSTAR (Korea Superconducting Tokamak Advanced Research) had finally completed its assembly in June 2007, and then achieved the goal of first-plasma in July 2008 through the four month's commissioning. KSTAR was constructed with fully superconducting magnets with material of $Nb_3Sn$ and NbTi, and their operation temperatures are maintained below 4.5K by the help of Helium Refrigerator System. During the first-plasma operation, plasmas of maximum current of 133kA and maximum pulse width of 865ms were obtained. The KSTAR Integrated Control System (KICS) has successfully fulfilled its missions of surveillance, device operation, machine protection interlock, and data acquisition and management. These and more were all KSTAR commissioning requirements. For reliable and safe operation of KSTAR, 17 local control systems were developed. Those systems must be integrated into the logically single control system, and operate regardless of their platforms and location installed. In order to meet these requirements, KICS was developed as a network-based distributed system and adopted a new framework, named as EPICS (Experimental Physics and Industrial Control System). Also, KICS has some features in KSTAR operation. It performs not only 24 hour continuous plant operation, but the shot-based real-time feedback control by exchanging the initiatives of operation between a central controller and a plasma control system in accordance with the operation sequence. For the diagnosis and analysis of plasma, 11 types of diagnostic system were implemented in KSTAR, and the acquired data from them were archived using MDSpius (Model Driven System), which is widely used in data management of fusion control systems. This paper will cover the design and implementation of the KSTAR integrated control system and the data management and visualization systems. Commissioning results will be introduced in brief.

A Theoretical Approach to the Nursing of Tae-Yang Symptom (한방에서의 태양병환자 간호를 위한 이론적 접근)

  • Jang Hye-Sook;Yang Koung-Hee;Kim Su-Jin
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.2 no.1
    • /
    • pp.45-53
    • /
    • 1995
  • In order to nursing practice of the patient in Oriental medicine, it is suggested that the fundamental recognition of Oriental medicine should be preceded. It is, however, difficult that we comprehend Oriental medicine generally since it is different from Western medicine in the point of th symptom. We have thought that is to be carried out to select and analyze a disease by the sense of Oriental medicine for the establishment of Oriental medical nursing. So we have tried out the analysis of Tae-Yang In view of the results so far achieved, it has been suggested that Tae-Yang Symptom applies to the first step of Sanghan Yug Kyung Symptom and consists of Palsy, Sanghan, Onbyung, Dropsy, and Congestion. In the Oriental medicine, Tae-Yang Symptom is recognized to be concerned with a common cold and the respiratory, renal and hepatic diseases. In the points of Orintal medicine, it is noticed that Tae-Yang Symptom is caused by the wind and cold evil, is related to human resisting force, and is fused with each other. And the treatment of Tae-Yang Symptom is various by the cause and the pathological mechanism. In the points of Western medicine. it is difficult to comprehend that various disease germs revolving each disease are implied by identical symptom. The summary of this study are as follows ; 1. In the outer-caused diseases. so called Tae-Yang Symptom, it is an important index to the patient's resisting force and the type of a disease whether he sweats, chills and the pulse is tense or not. 2. The treatments are various according the body's resisting force and the type of symptoms; harmonizing Yung & Wee(調榮衛) to Weaknees of surface(表虛證), sudorifics flourishing of evils(表實證), and antifebriles to On-byung(溫病). 3. If Tae-Yang Symptom is not cured, it progresses to develop complications ; Dropsy(蓄水) & congestion(蓄血), the former brings about renal diseases and the latter hepatic diseses. According to the resuslts mentioned above, we have come to the conclusion that the Oriental - medical nursing must emphasis the body's sesiting force and the type of symptoms rather than the name of a disease.

  • PDF

A Study on the Variation of Rn-222 Concentration in Groundwater at Busan-Geumjeong area (부산 금정구지역의 지하수에 포함된 라돈농도 변화 연구)

  • Cho, Jungg-Sook;Lee, Hyo-Min;Kim, Sun-Woong;Kim, Jin-Seop
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.149-158
    • /
    • 2012
  • In this paper, we measured the variations of radon concentrations in groundwater using low-level Liquid Scintillation Counter (LSC), an instrument for analyzing the alpha and beta radionuclides at its 10 sites around the Kumjung-Gu, north-western of Busan. Optimization of Pulse Shape Analyzer (PSA) to determinate the highest value of figure of merit (FM) was decided using Quantulus 1200 LSC with radium-226 source, the optimal PSA level was shown in the range of 100 to 110. The results show that the Minimum Detectable Activity (MDA) of radon concentrations is 0.61 $Bq{\cdot}L^{-1}$ for 20 minutes in PSA level. We find that the average radon concentration in groundwater is high in granitic rock area and low in volcanic rock area. (Biotite granite : 191.39 $Bq{\cdot}L^{-1}$, Micro graphic granite : 141.88 $Bq{\cdot}L^{-1}$, Adamellite : 92.94 $Bq{\cdot}L^{-1}$, Andesite (volcanic) : 35.35 $Bq{\cdot}L^{-1}$). No significant seasonal variation pattern is observed from the long-term variation analysis from 10 selected sites. We have not seen the significant correlation of radon concentration to groundwater temperature, atmospheric temperature, atmospheric pressure and rainfall. The concentration variation is probably caused by more complex factors and processes.

Shake Table Response and Analysis of RC Bridge Piers with Lap-Spliced Steel under NFGM (주철근 겹침이음된 RC교각의 근단층지반운동에 대한 진동대 응답과 분석)

  • Chung, Young-Soo;Park, Chang-Young;Hong, Hyun-Ki;Park, Ji-Ho;Shim, Chang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.451-458
    • /
    • 2008
  • The near-fault ground motion (NFGM) is characterized by a single long period velocity pulse of large magnitude. NFGM's have been observed in recent strong earthquakes, Izmit Turkey (1999), Kobe Japan (1995), Northridge USA (1994), etc. These strong earthquakes have caused considerable damage to infrastructures because the epicenter was close to the urban area, called as NFGM. Extensive research for the near-fault ground motion (NFGM) have been carried out in strong seismic region, but limited research have been done for NFGM in low or moderate seismic regions because of very few records. The purpose of this study is to investigate and analyze the effect of near-fault ground motions on reinforced concrete (RC) bridge piers with lap-spliced longitudinal reinforcing steels. The seismic performance of four RC bridge piers under near-fault ground motions was investigated on the shake table. In addition, a RC bridge pier is subjected to pseudo-dynamic loadings. Test results showed that large residual displacements were observed in RC bridge piers under NFGM. RC specimens on the shake table failed at relatively low displacement ductility, compared with the displacement ductility of RC bridge pier subjected to pseudo-dynamic loadings.

Low Temperature CO Oxidation over CuO Catalyst Supported on Al-Ce Oxide Support (Al-Ce 산화물에 담지된 CuO 촉매상에서 저온 CO산화반응)

  • Park, Jung-Hyun;Yun, Hyun Ki;Shin, Chae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.156-162
    • /
    • 2017
  • CuO(x)/0.3Al-0.7Ce catalysts with different CuO loadings (x = 2~20 wt%) were prepared by impregnation method and investigated the effects of CuO loadings on the low temperature CO oxidation. Of the used catalysts, the CuO(10)/0.3Al-0.7Ce catalyst showed the highest catalytic performance in the absence or presence of water vapor. In the presence of water vapor, the catalytic performance was drastically decreased, with a temperature of 50% CO conversion ($T_{50%}$) shifted to higher temperature by $50^{\circ}C$ compared to the those in dry conditions because of the competitive adsorption of water vapor on the active sites. The copper metal surface area calculated from $N_2O$-titration analysis and the oxygen capacity from CO-pulse experiments were increased with the CuO loadings and showed a maximum at 10 wt%CuO/0.3Al-0.7Ce catalyst. These trends are in good agreement with the tendency of $T_{50%}$ of the catalysts. From these characteristic aspects, it could be deduced that the catalytic performance was closely related to the oxygen capacity and the copper metallic surface area.

Electrochemical Properties of Pentadentate Binucleated Schiff Base Cobalt(Ⅱ) and Manganese(Ⅱ) Complexes in Nonaqueous Solvent (비수용매에서 이핵성 다섯자리 Schiff Base Cobalt(Ⅱ) 및 Manganese(Ⅱ) 착물들의 전기화학적 성질)

  • Ki-Hyung Chjo;Yong-Kook Choi;Song-Ju Lee;Seong-Seop Seo
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.3
    • /
    • pp.428-441
    • /
    • 1992
  • We synthesized a series of binuclear pentadentate Schiff base complexes such as $Co(Ⅱ)_2$ (BSPP)($H_2O)_2$, $Co(Ⅱ)_2$ (BSPD)($H_2O)_2$, $Mn(Ⅱ)_2$ (BSPP)($H_2O)_2$ and $Mn(Ⅱ)_2$ (BSPD)($H_2O)_2$, mononuclear pentadentate Schiff base complexes such as Co(Ⅱ)(BSP)($H_2O)$ and Mn(Ⅱ)(BSP)($H_2O)$. The composition of these complexes identified by IR, UV-visible spectrum, T.G.A., DSC, and elemental analysis. The electrochemical redox processes have been examined by cyclic voltammetry and differential pulse polarography with glassy carbon electrode in 0.1M TEAP-Py(-DMSO and -DMF) as a supporting electrolyte solution. As a result of electrochemical measurements, the reduction processes for pentadentate binuclear Schiff base cobalt(Ⅱ) and manganese(Ⅱ) complexes occurred to four steps in $M(Ⅲ)_2$ / $Mn(Ⅱ)_2$ and $Mn(Ⅱ)_2$ / $M(Ⅰ)_2$ (M; Co, Mn) two processes through each two reduction steps with one electron, by contrast, the mononuclear pentadentate Schiff base cobalt(Ⅱ) and manganese(Ⅱ) complexes occurred to two steps in M(Ⅲ) / M(Ⅱ) and M(Ⅱ) / M(Ⅰ) (M; Co, Mn) two processes with one electron reduction steps.

  • PDF

Characterization of a Revertant that Restroes the Export of Ribose-Bnding Potein to the Priplasm in Echerichia coli (리보스 결합 단백질을 페리플라슴으로 수송하는 복귀변이주의 분석)

  • ;;Randall, Linda L.
    • Korean Journal of Microbiology
    • /
    • v.26 no.4
    • /
    • pp.283-290
    • /
    • 1988
  • A spontaneous revertant of mutation rbsB103 that is ribose taxis-positive was characterized. This revertant was found to be export-competent in the export of ribose-binding protein shown by the disappearance of accumulated mutant precursor protein and the export of mature ribose-binding protein to the periplasm. The reversional change was shown to be in the region of risB gene that codes for the amino terminal portion of ribose-binding protein. Analysis by high-performance liquid chromatography of peptide patterns of ribose-binding proteins confirmed the relationship between the wild-type and the revertant proteins as shown for the mutant previously (Iida et al., 1985). When the processing rate of presursor proteins from the wild type and the revertant strain in vivo was compared by pulse-chase experiment, it was found that processing is less efficient than normal in the revertant. Purified mature proteins from both wild-type and revertant were subjected to amino acid sequencing. The results confirmed the amino acid changes deduced from the DNA sequencing and showed that processing of the revertant precursor occured in the correct position even though there are two different amino acids present in the signal sequence.

  • PDF

Molecular Characterization of Clinically Isolated Staphylococcus aureus (인천지역에서 분리된 황색포도상구균의 분자생물학적 특성 분석)

  • Oh, Bo-Young;Kim, Jung-Hee;Gong, Young-Woo;Lee, Jae-Mann;Go, Jong-Myoung;Kim, Yong-Hee
    • Korean Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.305-310
    • /
    • 2008
  • Staphylococcus aureus is one of the most significant pathogens and a causative agents of nosocomial infections. The emergence of methicillin resistant S. aureus (MRSA), in particular, has become a major clinical and epidemiological problems worldwide. In this study, we analyzed the toxin genes and investigated molecular epidemiological characteristics of S. aureus isolated from stools of diarrheal patients at the hospitals in Incheon. Of the 609 strains from 2,281 specimens, 173 strains retained enterotoxin; 68 isolates (39.30%), 100 isolates (57.80%) were classified to A and C type, respectively. In the antibiotic susceptibility, all of enterotoxin positive isolates were resistant to oxacillin. Eighty eight strains (50.86%) of 173 MRSA isolate possessed tsst gene, but eta and eth genes were not detected at all. In the detection of MRSA associated genes by PCR method, mecA genes were detected in 167 strains (96.53%). From the result of PFGE analysis, we classified tsst-positive MRSA to 10 types and 24 subtypes. Type A, H and F were the major strains comprised of 57.95% (51 strains), 10.22% (9 strains) and 9.09% (8 strains) respectively.

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF