• 제목/요약/키워드: pulse analysis

검색결과 2,090건 처리시간 0.032초

Analysis of Output Pulse of High Voltage and Nanosecond Blumlein Pulse Generator

  • Roh, Young-Su;Jin, Yun-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.150-155
    • /
    • 2013
  • A high voltage and nanosecond Blumlein pulse generator has been developed to produce an output pulse whose voltage level is greater than 250 kV and pulse duration 5 ns. The generator consists of various components such as a charging circuit, a pulse transformer, and a spark gap switch. As a heart of the generator, a Blumlein pulse forming line has been constructed in the cylindrical form using three cylindrical aluminum electrodes that are placed concentrically. Unlike the ideal Blumlein line, the output pulse of an actual Blumlein line may be affected by stray inductances and capacitances of switching and charging components, thereby degrading the performance of the generator. In this paper, PSPICE simulations have been performed to examine effects of stray inductances and capacitances on waveforms of output pulses. Simulation results show that the pulse waveform is significantly distorted mainly by the stray inductance of the spark gap switch.

Pulsed-field Gel Electrophoresis를 이용한 Mycobacterium fortuitum의 유전형 분석 (Genomic analysis of Mycobacterium fortuitum by pulsed-field gel electrophoresis)

  • 이태윤;도인아;김성광
    • Journal of Yeungnam Medical Science
    • /
    • 제12권2호
    • /
    • pp.366-385
    • /
    • 1995
  • 항산균 감염증의 예방 및 치료를 위하여는 역학적인 연구가 중요하다. 본 연구에서는 감염증의 분자역학적 연구를 위한 기법중 아직 항산균을 대상으로 pulsed-field gel electrophoresis (PFGE) 분석법을 확립하고자 하였다. PFGE분석에 적절한 제한효소는 DraI, AsnI 및 XbaI 등이었고 각 제한효소마다 최적의 PFGE조건은 서로 달랐다. DraI의 경우는 두단계로 나누어 전기영동을 시행하였다. 제1단계의 initial pulse는 10초 final pulse는 15초였으며 제2단계는 initial pulse는 60초 final pulse는 70초이었다. 전기영동시간은 각 단계마다 각각 14시간씩이었다. XbaI의 경우는 제2단계 없이 initial pulse가 3초 final pulse가 12초였고 전기영동시간은 22시간이었다. AsnI의 경우는 제2단계 없이 initial pulse가 5초 final pulse가 25초였고 전기영동시간은 22시간이었다. 모든 경우에 있어서 전압은 200V로 하였다. 표준균주로는 M. bovis BCG, M. tuberculosis 및 M. fortuitum등을 사용하였는데 PFGE분석상 동일균종내에서 표준균주들 간의 차이는 발견할 수 없었다. 임상에서 분리된 9주의 M. fortuitum 균주를 대상으로 AsnI 제한효소로 PFGE분석을 시행한 결과 2주만을 제외하고는 서로 간의 유전형 분류가 가능하였다. 균주간의 유전적 거리를 결정하기 위하여 cluster analysis를 시행한 결과 M. fortuitum 균주들은 크게 두 집단으로 나뉘었다. 제한효소 AsnI으로 동일 균종의 분류가 안되는 M. fortuitum 균주들은 XbaI 제한효소을 사용한 PFGE분석으로 유전형의 구분이 가능하였다. Cluster analysis를 시행한 결과 크게 두 집단으로 나뉘었던 M. fortuitum 균주들은 보다 복잡한 집단으로 분류되어 XbaI을 사용한 PFGE분석법이 M. fortuitum 균주분류를 위하여는 보다 적절함을 알 수 있었다. Cluster analysis에서 얻은 최대 % dissimilarity 값은 0.74(AsnI) 및 0.75(XbaI)로서 이 값은 arbitrarily primed polymerase chain reaction(AP-PCR)법보다는 높고 restriction fragment length polymorphism(RFLP) 법보다는 낮아 PFGE법이 RFLP를 보완하거나 대치할 수 있는 세균 유전형 분석법임을 알 수 있었다.

  • PDF

Parameter Estimation of The Distributed System via Improved Block Pulse Coefficients Estimation

  • Kim, Tai-hoon;Shim, Jae-sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.61.6-61
    • /
    • 2002
  • In these days, Block Pulse functions are used in a variety of fields such as the analysis and controller design of the systems. In applying the Block Pulse function technique to control and systems science, the integral operation of the Block Pulse series plays important roles. This is because differential equations are always involved in the representations of continuous-time models of dynamic systems, and differential operations are always approximated by the corresponding Block Pulse series through integration operational matrices. In order to apply the Block Pulse function technique to the problems of continuous-time dynamic systems more efficiently, it is necessary to find th...

  • PDF

비선형 시뮬레이션에 의한 리니어 펄스모터의 특성해석 (Linear Pulse Motor Characteristics Analysis using Non-linear Simulation)

  • 이제희;허욱렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.584-587
    • /
    • 1992
  • Because linear motor directly drives linear motion, it does not need conversion equipment such as belt and gear. Especially linear pulse motor provide more precise positioning and large force of linear pulse motors. As current manufacture technic of linear pulse motor is much to be desired at home. This motor lay out to make use of computer aided design program, In this paper the experimental motor is 2-phases 4-poles hybrid pulse motor which has teeth per pole Simulation program is divided its function into 4 parts - air gap permeance analysis, permanent magnet & non-linear core operating point determine, winding configuration, leakage flux analysis. It is possible to make motor static and magnetic characteristics for this simulation program. Also, by varying input parameters of the program, experimental motor is to be compared to motor characteristics.

  • PDF

맥동관의 엔탈피유동에 대한 2차원 해석 (Two-Dimensional Analysis of Enthalpy Flow in a Pulse Tube)

  • 백상호;장승철;정은수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권1호
    • /
    • pp.42-47
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass. momentum an energy equations of the gas as well as energy conservation of the tube wall. The mean temperature of the gas and the tube wall was obtained directly by assuming that the outer surface of a pules tibe wall is adiabatic. Axial profile of mean temperature is small. but it deviates significantly from linear profile when the dimensionless frequency is large. Effect of operating frequency. tube wall thickness, velocity ratio and velocity phase angle between both ends of a pulse tube on net enthalpy flow were shown.

  • PDF

동하중을 받는 복합재료 원통셸의 동적거동 해석 (On the Dynamic Response of Laminated Circular Cylindrical Shells under Dynamic Loads)

  • 이영신;이기두
    • 대한기계학회논문집
    • /
    • 제17권11호
    • /
    • pp.2684-2693
    • /
    • 1993
  • The free vibration and dynamic response of cross-ply for CFRP and GFRP laminated circular cylindrical shells under dynamic loadings are investigated by using the first-order shear deformation shell theory. The modal analysis technique is used to develop the analytical solutions of simply supported cylindrical shells under dynamic load. The analysis is based on an expansion of the loads, displacements and rotations in a double Fourier series which satisfies the and boundary conditions of simply support. Analytical solution is assumed to be separable into a function of time and a function of position. In this paper, the considered load forces are step pulse, sine pulse, triangular(1, 2, 3) pulse and exponential pulse. The solution for a given loading pulse can be found by involving the convolution integral. The results show that the dynamic response are governed primarily by the natural period of the structure.

중풍환자의 변증에 사용되는 맥진 지표에 관한 연구 (Study on the Basic Pulse Indicators for Pattern Identifications in Stroke)

  • 이정섭;고미미;강병갑;김소연;김정철;오달석;이인;김윤식;방옥선
    • 동의생리병리학회지
    • /
    • 제23권5호
    • /
    • pp.964-968
    • /
    • 2009
  • The purpose of this study is to select the major pulse indicators and evaluate their significance in discriminating the subtypes of Pattern Identifications (PI) from stroke patients. Decision tree analysis was carried out using clinical data collected from 835 stroke patients with the same subtypes diagnosed identically by two experts with more than 3 year clinical experiences. Among the 10 pulse indicators, 6 major pulse indicators (slow, rapid, strong, weak, slippery, and fine pulse) were selected by decision tree analysis. The accumulated distributions of six pulse indicators in each PI showed that strong was major pulse indicator in Fire-Heat pattern, slippery in Dampness Phlegm pattern, weak in Qi Deficiency pattern. But there were two major combinations in Yin deficiency pattern, weak or fine with rapid pulse and weak or fine without rapid pulse. Therefore, it is suggested that 6 pulse indicators can be used for discrimination of PI in stroke patients, though the combination studies between these pulse indicators and the other PI indicators are left for further study.

웹기반 임상 맥파 데이터 분석 시스템에 관한 연구 (The Study on the Web-Based Analysis System of Oriental Pulse Waveform)

  • 이준영
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.9-12
    • /
    • 2012
  • This paper analyzes a web-based clinical management system and conducts research on the pulse. Pulse analysis and the clinical study management system proposed by the web-based research holds significance in that it improves the objectivity and accuracy of pulse diagnosis. In particular, exact data must be analyzed through the clinical interpretation of these studies. Eventually oriental pulse standardization work will be continuously sustained. The findings of this study will help achieve remote diagnosis and consultation and updating of database. Research must be expanded to the development of telemedicine technology to create u-Health that will lead this present era.

마이크로스트립 선로상 가우시안 펄스신호의 전파특성 해석 및 측정 (Propagation characteristic analysis and measurement of gaussian pulse signals on the microstrip line)

  • 이승엽;신호섭;김남;권원현
    • 한국통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.1425-1432
    • /
    • 1998
  • The propagation properties of Gaussian pulse signals on the microstrip line are investigated by the Kirschning & Jansen's approximated equation to meet the frequency range of a pulse, accuracy, and geometrical requiremtns of the microstrip line. The dispersion of pulse signals is analyzed regarding to the relative permittivity .epsilon.$_{r}$, substrate height h and strip width w of the microstrip line. To verify theoretical results, several samples of 50.OMEGA. microstrip lines are fabricated. And the characteristics of pulse propagation along these lines are simple measured using VNA(Vector Network Analyzer) with time-domain analysis function. A fairly good agreement has been found between the measured pulse waveforms and computer simulations.

  • PDF