• Title/Summary/Keyword: pulse

Search Result 10,382, Processing Time 0.035 seconds

A Study on the Pulse Peak Voltage and Cascading Ratio of Compact Pulse Generator using Cascading Method (Cascading 방식을 적용한 펄스발생기의 펄스전압 변성 및 Cascading 비율 특성)

  • Joung, Jong-Han;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.329-333
    • /
    • 2001
  • The pulsed poser system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNox/DeSOx power system, ozon generator, etc. A pulse energy efficiency for load depends on the rising time, peak value, pulse duration and impedance matching, etc. The pulse generator generally required for short pusle duration and high peak value was forced to consider its volume and economy. In this study, developing a compact pulse generator that applied for cascading method to be made of two pulse transformers, we compared cascading voltage with non cascading one by applying the pulse energy to load. Adopting cascading technique to pulse transformer, we found that average cascading voltage was about 60[%] of theoretical value. Maximum cascading ratio was calculated at 60 times compared with non cascading voltage.

  • PDF

Research on the Variable-Width and Double-Pulse Generator (가변폭 Double-Pulse Generator에 관한 연구)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.7 no.4
    • /
    • pp.6-13
    • /
    • 1970
  • The variable-width and double-pulse generator Here described is completely transistorized so its size is small and it is convenient to handle. The frequency ran be varied from 1 KHz to 500KHz, the pulse width from 0.4$\mu$sec to 8$\mu$sec, amplitude from 1V to 10V, and interval of double pulse from 0$\mu$sec to 12$\mu$sec. Positive and negative signal or double pulse trains can he obtained. An analysis has been carried out for each stage and the design equations are derived. The experimental results are compared with the analysis.

  • PDF

A Study on the Collection Characteristics of a Wide Plate-Spacing Electrostatic Precipitator -II. Effect of Wave Form of Pulse Energization - (광폭 전기집진기의 집진특성에 판한 연구 - II. 펄스 하전 파형의 영향 -)

  • 김용진;하병길;정상현;홍원석;하대홍;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1059-1064
    • /
    • 2001
  • This study Investigates the effect of the wave form of pulse energization on the collection characteristics of a wide plate spacing electrostatic precipitator. For the semi-pulse energization, the peak current and voltage of the energization increases with increase of the pulse period, and the corona current increases, as pulse ratio decreases. For the micro-pulse energization, the corona current increases with increase of the pulse voltage. The collection efficiency of semi-pulse and micro-pulse energization is larger than that of DC charge.

  • PDF

The Methodic Study on a Standard of Classification of Pulse Condition -a Focus of ${\ulcorner}$The Pulse Studies of Bin-Ho(瀕湖脈學)${\lrcorner}$- (맥상 분류 기준에 대한 방법론적 고찰 - "빈호맥학(瀕湖脈學)"을 중심으로 -)

  • Lee, Ju-Ho;Choi, Hwan-Soo;Kim, Chul-Jung
    • Korean Journal of Oriental Medicine
    • /
    • v.10 no.1
    • /
    • pp.49-61
    • /
    • 2004
  • The Standardization of terms in The Pulse studies(脈學) is a need for development of learning. This study, for the correction of existing misused terms in The Pulse studies, we study on modernly and objectively the terms in The Pulse studies. By a focus of ${\ulcorner}$The Pulse Studies of Bin-Ho(瀕湖脈學)${\lrcorner}$, we studies on the new classification of pulse condition. The error of a existing technical books on Pulse studies begin that the classification of pulse condition is not establish a Standardization. For the correction of existing misused terms in The Pulse studies, we study on the pulse condition is expressed objectively a blood vessel that it is a subject of pulse condition. The expression of blood vessel contain a depth of blood vessel, a speed of pulsation, a curve of blood vessel, thickness of blood vessel, a diameter of blood vessel in expand and contract of blood vessel, a interval in expand and contract of blood vessel, a distinctness on a boundary of blood vessel, a speed of blood flow in blood vessel, a volume of blood flow in blood vessel, a condition of blood in blood vessel, a propelling power of blood vessel. These is standard of the new classification of pulse condition.

  • PDF

The Sasang Constitutional Thought of Pulse Diagnosis (맥진(脈診)의 사상의학적(四象醫學的) 고찰(考察))

  • Kim, In-Tae;Lee, Soo-Kyung;Lee, Eui-Ju;Koh, Byung-Hui;Song, Il-Byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.15 no.3
    • /
    • pp.22-32
    • /
    • 2003
  • The pulse diagnosis is the basic method of oriental medicine diagnosis. But in sasang constitutional medicine, it is said that it's not a major diagnotic method. But we don't have any sasang constitutional study of the pulse diagnosis. So I made this study by research of changing concept of the pulse diagnosis in chinese medical history and Dongyi Suse Bowon (longevity and life preservation in oriental medicine). The conclusion as follows. 1. There were many kinds of the pulse diagnosis in the ancient times, it has developed to simple and effective diagnotic method. Simple and effective is the major point of medical development, the 24 pulse is abridged to Floating Pulse(浮), Deep Pulse(沈), Slow Pulse(遲), Rapid Pulse(數) 2. The latter term of Chosun, the practical study was developed. In the view of the practical study, the pulse diagnosis has a lot of cricical point. Jung Yak-Yong, in his writing Mak Lon(脈論), criticize the pulse diagnosis. 3. In the sasang constitutional medicine, the constitutional diagnosis is very important. The methods of the constitutional diagnosis are three, the way of mind and greed, knowledge and deed, external figure and physical traits. But the pulse diagnosis is one of the way of external figure and physical traits, so we can't diagnose the exact constitution by the pulse diagnosis. 4. Dong-mu conclude that the pulse diagnosis is just the diagnostic way of symptom. But in the clinical situation, the ordinary symptoms are more important than the pulse diagnosis, because it is useful to know the condition of the ingestive food metabolism and the Qi-yack metabolism

  • PDF

Mobile PULSE : A Routing Protocol Considering the Power and the Route Recovery Time in Sensor Networks with A Mobile Sink Node (모바일 PULSE : 모바일 싱크 노드를 가진 센서 네트워크에서의 경로 복구 시간과 전력 소모량을 고려한 라우팅 프로토콜)

  • Lee, Chi-Young;Lee, Shin-Hyoung;Yoo, Chuck
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.2B
    • /
    • pp.151-161
    • /
    • 2009
  • The PULSE protocol can greatly reduce power consumption using a node's sleep state. But this protocol does not consider movement of a sink node in a sensor network. In the mobile sensor network a routing protocol must recover path error by movement of a sink node as quickly as possible. Therefore we have to achieve fast path recovery and power saving to support movement of a sink node in a sensor network. This paper proposes the Mobile PULSE protocol which is a improved routing protocol for a mobile sink node. And we evaluate Mobile PULSE and show that the Mobile PULSE reduces the recovery time about 40% compared with original PULSE protocol. Mobile PULSE increases energy consumption than PULSE as a maximum of 0.8%, which means Mobile PULSE is similar to PULSE in energy consumption. This paper shows mobile PULSE's capability in the mobile sensor network through evaluation of path recovery time and power consumption.

The study of non-contact/non-invasive pulse analyzing system using Optical Coherence Tomography (OCT) for oriental pulse diagnosis (비접촉식 광생체단층촬영 기술을 이용한 맥진 연구 -맥의 빠르기, 크기 및 맥력을 중심으로-)

  • Na, Chang-Su;Youn, Dae-Hwan;Kim, Young-Sun;Lee, Chang-Ho;Jung, Woon-Sang;Kim, Jee-Hyun;Choi, Chan-Hun
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.1-13
    • /
    • 2009
  • Objective: Optical Coherence Tomography (OCT) has emerged as an important optical imaging modality in non-invasive medical diagnostics. Hence, the aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by the non-contact/non-invasive pulse analyzing system using OCT on Chon(寸), Kwan(關), Chuk(尺). Method: Four korean medical doctors and the non-contact/non-invasive pulse analyzing system using OCT have measured the rapidity, the dimension, and the power of pulse waves of 25 volunteers. First, four korean medical doctors measured pulse waves of volunteers. During measuring, four doctors were separated from each other and so were volunteers. And then, the pulse waves of volunteers were measured by OCT. This was performed on the right Chon(寸), Kwan(關), Chuk(尺). Results: The study showed that the traditional method and the OCT based method had the 88% matches on the values of the slow and rapid pulse condition (遲數), 64% matches on the values of the small and big pulse condition(微細弱緩大[洪]), and 72% matches on the values of the weak and strong pulse condition(虛實). Conclusions: Based on the high similarities of the measurements of two approaches, we suggest that the OCT based pulse diagnosis method is useful for compensating the traditional method for the pulse diagnosis.

  • PDF

A study on the reason that pulse-feeling method of meridians diagnosis flows into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse -A study on the transition of pulse-feeling method- (경맥진단(經脈診斷)의 맥진법(脈診法)이 기구맥(氣口脈)의 촌관척(寸關尺) 육부정위맥진법(六部定位脈診法)으로 연변(演變)된 연유(緣由)에 관(關)한 연구(硏究) -경맥학설(經脈學說) 및 맥진법(脈診法)의 상관성(相關性)-)

  • Lim, Han-je;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.1-20
    • /
    • 2004
  • Pulse-feeling took its origin from making a diagnosis along meridians in the course of discovering and forming meridians and for a long time its meaning was mixed with meridians in the course of recognizing "The Pulse" then was separated from meridians in the early days of Western Han Dynasty. Ancient pulse-feeling methods are pulse-feeling method by the twelve regular meridians, pulse-feeling method by three regions and nine modes, pulse-feeling method by Inyeong(人迎) and Chon-gu(寸口), etc. Pulse-feeling was changed in proportion to diagnostic purpose and method of treating and if method and region of pulse-feeling is arranged, we will infer correlation between meridians and pulse-feeling and will infer transitional system of past pulse-feeling and will forecast transition of future pulse-feeling. As the result that I study the transition of the above three pulse-feeling methods of meridians diagnosis: 1. Three pulse-feeling methods of meridians diagnosis flowed into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ and were changed into diagnostic method being fit for use of five Su points, The Front-Mo points and Back-Su points that grasp the pathology of mutual internal organs and treat the disease. 2. Today it is suggesting the transition of another pulse-feeling method that do not apply diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ to 19C Sasang(四象) Constitutional Medicine or 20C Eight Constitutional Medicine.

  • PDF

A Study on Characteristics of Pulse Diagnosis in Infertile Women (여성 불임환자의 맥진특성 연구)

  • Yoo, Jeongeun;Jang, Saebyel;Yoo, Dongyoul
    • Journal of Haehwa Medicine
    • /
    • v.23 no.2
    • /
    • pp.15-21
    • /
    • 2015
  • Objective : The purpose of this study is to demonstrate the characteristics of pulse diagnosis in infertile women. Methods : We have studied 38 women infertility patients in the Dunsan oriental hospital by using pulse diagnostic device. Pulsation and pulse types have been analyzed with variables of infertility factors. Statistical analysis was performed by adopting descriptive and inferential tests. Results : Both right and left chi parts were shown different from other parts. In small intestine and gall bladder showed significantly different pulsation according to the infertility factor. Short pulse, fine pulse, skipping pulse, shallow pulse and deep pulse were often representative pulse types for the main organs of woman infertility. In Triple energizers showed significantly different shallow pulse type according to the infertility factor. Conclusion : The results corresponded closely with previous literature on pulse diagnosis about infertile women.

  • PDF

Development of Voltage Regulator and Pulse Charger Using Pulse Current for Reuse of the Waste Lead Acid Battery (폐납축전지 재활용을 위한 펄스전류에 의한 전압조정기와 펄스충전기의 개발)

  • Shin, Choon-Shik;An, Young-Joo;Kim, Dong-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.65-73
    • /
    • 2007
  • In this study, the pulse charger and voltage regulator are proposed that can reuse the waste lead acid battery. The first we develop the voltage regulator that can reuse the waste lead battery. And the pulse current is applied to the terminal of the waste lead acid battery. The voltage regulator is available principle of the pulse current which can reduce the sulfate to incipient material such as Pb and PbO2. Therefore the internal resistance of the lead acid battery is decreased, the performance of the lead acid battery is improved and the durability is prolonged. The second we develop the pulse charger using the voltage regulator. The pulse charger uses the switch mode of the forward convert method. The pulse charger maintain the constant voltage in state removing the lead acid battery and when it connected the pulse charger, it is converted the charge mode of the constant current immediately. It continues the rapid charge until the full state of the lead acid battery. After that the pulse charger is converted to the charge mode of constant voltage automatically, and then it continues the normal charge. The experiment results show that the effectiveness of the voltage regulator and pulse charger such as the good performance and the prolonged durability in lead acid battery of the small and large capacity.