• Title/Summary/Keyword: pulse/respiration ratio

Search Result 13, Processing Time 0.018 seconds

Correlation between Pulse-respiration Ratio and Heart Rate Variability (맥솔(脈率)과 심박변이도(心搏變移度)의 상관성(相關性) 연구(硏究))

  • Yang, Dong-Hoon;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.104-120
    • /
    • 2006
  • Background : Pulse-respiration ratio has been used for estimating subject's status in oriental medicine. Pulse and respiration is strongly associated with autonomic nerve system. But there is no research about correlation between pulse-respiration ratio and autonomic nerve system. Objectives : We performed this study to know correlation between pulse-respiration ratio and HRV(heart rate variability) that shows autonomic nerve system status well and to clarify clinical meaning of pulse-respiration ratio. Methods : After subject's 10 minutes rest, we measured subject's ECG, respiration pattern and HRV. In this research, subject's number is 95(Male 50/Female 45). We calculated pulse-respiration ratio from ECG and respiration pattern. Then, we analyzed correlation between pulse-respiration ratio and HRV parameters in all subjects, 2 group divided by Wan-Maek(P-R ratio 4.28). We tried to compare HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek group. Correlation analysis between pulse-respiration Ratio and Pulse rate, respiration rate is performed. Finally correlation analysis between Respiration and HRV parameters in all subjects, 2 group divided by Wan-Maek(4.28) is studied. Results : 1. Mean pulse-respiration is 4.10${\pm}$0.67, Mean pulse rate is 68.06${\pm}$7.82bpm, Mean respiration rate is 16.81${\pm}$2.72 times per minute in all subjects. 2. Correlation analysis between pulse-respiration ratio and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm(correlation coefficient 0.306, p= 0.018), lnHF (0.308, p=0.002) is significantly correlated with pulse-respiration ratio. 3. Comparison of HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek Group is not significant. 4. Pulse-respiration ratio is more affected by respiration rate(correlation coefficient-0.17, p=0.000) than pulse rate (correlation coefficient 0.396, p=0.000). 5. Correlation analysis between respiration rate and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm (correlation coefficient -0.327, p=0.011), LF/HF(0.346, p=0.007), lnHF (-0.355, p=0.006) are significantly correlated with respiration rate. Conclusion : Pulse-respiration ratio and parasympathetic index has positive correlation. The closer Wan-Maek, The higher parasympathetic index in low pulse-respiration ratio group. Respiration rate is more related with pulse-respiration ratio than pulse rate. Respiration is negatively correlated with autonomic parameters. And the slower respiration, the higher parasympathetic index in low pulse-respiration ratio group.

  • PDF

Detection and interpretation of wan-maeck by the pulse diagnostic apparatus -on the pulse/respiration rate- (완맥(緩脈)의 동서의학적(東西醫學的) 해석 -맥율(脈率)을 중심으로-)

  • Park, Young-Bae;Kang, Sung-Keel;Kim, Chang-Hwan;Koh, Hyung-Kyun;Kim, Yong-Suk;Lee, Yun-Ho;Kim, Sung-Woon;Huh, Wung;Youn, Chung-Hwa
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.143-156
    • /
    • 1997
  • This report was conducted to quantify the pulse/respiration ratio and set up the normal range of wan-maeck(緩脈). In order to objectify the pulse diagnosis and use as basic clinical index of Cold-Hot diagnosis, we developed the hardware and software for detection and interpretation of pulse/respiration ratio, pulse/expiration ratio, pulse/respiration ratio, inspiration time, expiration time, respiration frequency, respiration time, duration of one pulse and pulse and pulse rate per minute, The results were as follows; pulse/respiration ratio is $4.30{\pm}1.03$ times, pulse/respiration ratio is $1.60{\pm}0.32$ times, pulse/respiration ratio is $2.37{\pm}0.75$ times, inspiration time is $1.35{\pm}0.20$ sec, expiration time is $1.89{\pm}0.39$ sec, respiration frequency is $17.16{\pm}3.49$ times/min, total respiration time is $3.63{\pm}0.71$ sec, duration of a pulse is $0.86{\pm}0.15$ sec, pulse rate is $71.51{\pm}12.30$ times/min.

  • PDF

The Analysis on the Reliability of Measuring Pulse-Respiration Ratio (맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析))

  • Kim, Dong-Hoon;Yang, Dong-Hoon;Huh, Woong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

A Feasibility Study of Pulse Rate Per Respiration as an Indicator for the Reaction to Cold Stress (냉자극에 대한 맥율 변화 예비 연구)

  • Bae, Jang Han;Jeon, Young Ju;Kim, Hyunho;Kim, Jaeuk U.
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.668-673
    • /
    • 2014
  • Cold and Heat pattern identification(CHPI) in traditional East Asian medicine(TEAM) is one of the major indicator to distinguish characteristics of disease and to determine treatment method. Basic parameters to determine CHPI include the pulse rate, respiration rate, and pulse power. Studies to associate physiological responses of human body by cold stress(CS) with CHPI in TEAM were rarely done so far. This study aims to explore the effects of cold stress on pulse signal via a feasibility study for three subjects and investigate some indices which can reflect autonomic nerve reaction(ANR). We measured radial pulse signals and respiration signal of the investigated subjects before the CS, during the CS which continues for 5 minutes, and immediately after the CS, respectively. Finally, we analyzed the pulse rate (P), respiration rate (R), pulse power, pulse depth, and pulse rate per respiration (P/R ratio). As a result, the P/R ratio showed a consistently decreasing tendency through the CS stimulation process, while other parameters behaved more complex and in subject-specific ways. It implies that, among candidate parameters, the P/R ratio is a simple but the most probable parameter that can be used as the ANR indicator. This result is also consistent with the theory in TEAM scripts, in which the P/R ratio is predicted to be a direct indicator for the CHPI. This pilot study shows that P/R ratio can be more appropriately associated with the ANR than heart rate or respiration rate alone. Extensive studies will be necessary to verify or confirm the P/R ratio as an appropriate and well defined parameter for ANR.

Correlation Results of Pulse/Respiration Ratio and Body Composition Analysis (맥솔(脈率)과 체성분(體成分) 분석(分析)의 상관성(相關性) 연구(硏究))

  • Park, Jae-Sung;Park, Young-Bae;Kim, Min-Yong;Park, Young-Jae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.132-150
    • /
    • 2006
  • Objectives : The objective is that we measure and analyze Pulse-Respiration Ratio and Body Composition Analysis to study the correlation between both. Methods : First, after subjects take a rest over 10 minutes, we measure their electrocardiogram and respiration pattern through which we take average peak interval to calculate an average pulse cycle and a respiration cycle. An average respiration cycle divided by an average Pulse Rate gives Pulse-Respiration Ratio. Next, we draw out 22 Body Composition Analysis indicators by using In-Body 720 model. Last, we analyze and take statistics on them by using SPSS 13.0 program. Results : Negative is the correlation between P/R Ratio and Body Composition Analysis indicator like fatness degree, body fat volume, body fat rate, abdominal fatness, BMI. Conclusions : 1. The higher P/R Ratio the more likely to be thin, the lower P/R Ratio the more likely to be fat. 2. We separately analyze P/R Ratio depending on each breathing frequency and pulse frequency to find out that breathing frequency has great influence and that breathing frequency decides the fatness degree. 3. In study on the correlation between P/R Ratio and Body Composition Analysis, fatness degree, in-body fat volume, in-body fat rate, BMI are the related indicators, which shows the connection with the fatness indicators. 4. In study on the correlation between Han-Yeol [寒熱] grade and Body Composition Analysis indicators, the result is that Han[寒] has no connection and that only Yeol[熱] grade has something to do with it, which means the higher heat symptom subjects have, the more basic metabolism volume and muscular build they have.

  • PDF

A STUDY ON PULSE RATE SYSTEM

  • Kim, H. K.;S. C. Han;K. K. Min;W. Huh
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.535-537
    • /
    • 1998
  • In this paper, we devised a pulse rate detection system to provide basic clinical index of cold-hot diagnosis of oriental medicine. The system consists of pulse signal detection, respiration signal detection, electrocardiograph detection, A/D conversion and computer system parts. We define a pulse rate by a pulse count to the respiration period inspiration pulse rate by a pulse count to the inspiration period, and expiration pulse rate by a pulse count to the expiration period. The clinical experiments for normal Person to evaluate the pulse rate detection system show the pulse/respiration ratio of 4.30${\pm}$1.03, the pulse/inspiration ratio of 1.60${\pm}$0.32, the pulse/expiration ratio of 2.37${\pm}$0.75.

  • PDF

A Study of Correlation between Pulse-Respiration Ratio and Characteristics of Thermal Temperature (체표온도특성(體表溫度特性)과 맥율(脈率)의 상관성(相關性) 연구(硏究))

  • Lee, Hyuk-Jae;Park, Young-Jae;Park, Young-Bae;Oh, Hwan-Sup
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.103-130
    • /
    • 2008
  • Background: For standardizing of Han-Yeol [寒熱], which is a kind of diagnosis method in oriental medicine, it is necessary to investigate into relationship of symptoms and signs representative of Han-Yeol [寒熱] to the biofunctional medical signals; thermal temperature by Thermography, Pulse-Respiration Ratio and so on. By correlation analysis of these data items acquired from patients, it could be provides the fundamental data for standardizing of Han-Yeol [寒熱]. Objectives: We performed this study to check the characteristics of thermal temperature with Han-Yeol [寒熱] statue by pulse-respiration ratio. Methods: We selected nine regions around acupoints including Yin dang[印堂], Sugu[水溝, GV26], Ch'ondol[天突, CV22], Chonjung[CV17], Chung-wan[中脘, CV12], Chonchu[天樞 S25], No-gung[勞官, P8], and calculated based on the utility of R.O.I.(Region of Integer) by IR-2000 these points temperature from 68 subjects. In practicing pulse-respiration ratio over 4.0 means the statues of Yeol [熱], pulse-respiration ratio below 4.0 means the statues of Han [寒]. To optimum conditions thermal temperature, which are not effected by internal and external variables, we studied preceding research. The results shows that optimal time period is 20minutes after undressed and the optimal region is the region around acupoints including Sugu [水溝, GV26]. Based on a preceding research results, we analyzed these data by Paired T-test between GV26 Region and 8-Thermography Regions and two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio. Results: 1. In applying of two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio, Sugu [水溝穴, GV26] - [印堂穴, HN1], Sugu 水溝, GV26] - Chonjung[CV17], Sugu [水溝, GV26] -Chung-wan[中脘, CV12]had significant differences. 2. In applying of Paired T-test between Sugu [水溝穴, GV26] Region and 8- Thermography Regions, there were significant differences except of Sugu [水溝穴, GV26] -Chondolp[天突, CV22]. 3. In the difference of Sugu [水溝, GV26] -Chung-wan[中脘, CV12], thermal temperature increases a lot in the statues of Yeol [熱], thermal temperature decreases a lot in the statues of Han [寒]. Conclusions: On the analysis of Thermography, we obtain the measurement conditions were considered the individual variations. And it is different that the thermal temperature change on Thermography according to Han-Yeol [寒熱] statue by pulse-respiration ratio.

  • PDF

Physiologic changes on the rescuer and efficiency of CPR in the increased chest compression (흉부압박의 횟수증가가 구조자에게 미치는 생리학적 변화와 심폐소생술 정확도에 미치는 영향)

  • Choi, Uk-Jin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.43-53
    • /
    • 2008
  • Purpose : This study was designed to examine physiological changes in the body of rescuers conduct CPR according to the 2005 new guideline from American Heart Association. The ratio of artificial respiration has changed from 15 : 2 into 30 : 2 in 2005. The researcher tried to know the correlation between the physiological changes and the accuracy of CPR. Method : The examinees of this study were 26 students (Dept. of Emergency Medical Service). After the training, participants conducted 10 minute CPR and soon after the CPR, their vital signs were checked, and lactic acid and concentration of ammonia were analysed from their blood samples. Questionnaires to ask their subjective fatigue level were filled out after blood samples and 10 minute - CPR was performed. Results : 1) After the CPR, concentrations of ammonia were $149.71{\mu}{\ell}/d{\ell}$ and $162.17{\mu}{\ell}/d{\ell}$ in 15 : 2 and 30 : 2, respectively. The number was higher in 30 : 2 but it wan not statistically meaningful (p = .493). Log value of lactic acid was a little higher in 30 : 2 with 42 log($mmol/{\ell}$) and 54 log($mmol/{\ell}$) in 15 : 2 and 30 : 2, respectively but it was not statistically meaningful (p = .113). 2) Blood pressure in 15 : 2 and 30 : 2 were 118.50 mmHg and 125.08 mmHg while pulse in two different cases were 96.14 and 97.25, showing no statistically significant differences (blood pressure : p = .155, pulse : p = .841). 3) Subjective fatigue was a bit high in 30 : 2 with 5.93 and 6.92 points in 15 : 2 and 30 : 2 respectively but it was not statistically meaningful (p = .142). 4) In the 10 minute CPR, respiration accuracy was 96.21% in 15 : 2 and 94.79% in 30 : 2. There was no statistical significances between the two(p = .225). In the meanwhile, chest compression accuracy was 92.57% in 15 : 2 and 91.83% in 30 : 2. From the beginning to the end of chest compression, there showed no difference(p = .425). the type of CPR did not influence upon the accuracy of chest compression(p = .756). Conclusion : In the CPR conducted by skilled rescuers for 10 minutes, there were no statistically meaningful differences between 15 : 2 and 30 : 2 in the concentration of fatigue element in a blood, subjective fatigue, vital signs and accuracy of CPR. Therefore, 30 : 2 CPR recommended by American Heart Association need to be recommended and performed in scene size up.

  • PDF

Development of Animal Health Monitoring System Model V. Analysis of Risk Factors in Clinical Part (동물(젖소)건강 Monitoring system 모델 개발 V. 임상학적 위해요소 분석)

  • 최민철;김종수;김곤섭;김용환;이효종;손우진;원현희
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.439-442
    • /
    • 1999
  • An animal health monitoring system in Gyeongnam area (near-Chinju) was studied to evaluate the environmental risk factors, physical examinations and 4 disease entities(abomasal displacement, traumatic reticulopericarditis & -peritonitis, milk fever and lameness) in 40(34 in second year)dairy herds (total 1253 dairy cattle). In feeding environments, we examined housing system, forage percentage in ration, stall types, playground, cleanness of stall. In housing system, most of herds (60%) have tie-stall types and 36 herds are open-type housing. The forage ratio of ration was less than 50% in most of herds (67%). 39 herds had their own playgrounds and the frequency of playground cleanness was irregular, Physical examinations included the T(temperature), P (pulse), R (respiration), abnormalities of superficial lymph nodes, claw examination and total CBC with blood from tail veins. T, P, R are within normal limits (T : 38.1$\pm$0.6$^{\circ}C$, P : 84.6$\pm$12.9/min., R : 24.0$\pm$7.6/min. ,respectively), the swelling of lymph nodes were shown in 13 cattle and overall claw trimming was required in 3 herds. In blood examination, 23 cattle showed leuko-cytosis and 7 cattle showed low RBC and hemoglobin level, the other cattle were within normal limits (WBC : 8.90$\pm$2.06 10$^3$/ul., RBC : 6.36$\pm$1.02 10$^{6}$ ul, Hb : 9.83$\pm$ 1.20 g/dl PCV : 27.43$\pm$5.67 %, respectively). In 4 disease entities, we found some metallic foreign bodies in men of 13 cattle, which had predisposing factors of traumatic reticulopericarditis and reticuloperitonitis, 13 abomasal displacement, 51 milk fever and lameness in 39 cattle.

  • PDF

Enhanced PHB Accumulation in Photosystem- and Respiration-defective Mutants of a Cyanobacterium Synechocystis sp. PCC 6803 (Synechocystis sp. PCC 6803의 에너지 대사 결함 돌연변이 균주에서의 Poly(3-hydroxybutyrate) 축적량 증진)

  • Kim Soo-Youn;Choi Gang Guk;Park Youn Il;Park Young Mok;Yang Young Ki;Rhee Young Ha
    • Korean Journal of Microbiology
    • /
    • v.41 no.1
    • /
    • pp.67-73
    • /
    • 2005
  • Photoautotrophic bacteria are promising candidates for the production of poly(3-hydroxybutyrate) (PHB) since they can address the critical problem of substrate costs. In this study, we isolated 25 Tn5-inserted mutants of the Synechocystis sp. PCC 6803 which showed enhanced PHB accumulation compared to the wild-type strain. After 5-days cultivation under nitrogen-limited mixotrophic conditions, the intracellular levels of PHB content in these mutants reached up to $10-30\%$ of dry cell weight (DCW) comparable to $4\%$ of DCW in the wild-type strain. Using the method of inverse PCR, the affected genes of the mutants were mapped on the completely known genome sequence of Synechocystis sp. PCC 6803. As a result, the increased PHB accumulation in 5 mutants were found to be resulted from defects of genes coding for NADH-ubiquinone oxidoreductase, O-succinylbenzoic-CoA ligase, photosystem II PsbT protein or histidine kinase, which are involved in photosystem in thylakoid inner membrane of the cell. The values of $NAD(P)H/NAD(P)^+$ ratio in the cells of these mutants were much higher than that of the wild-type strain as measured by using pulse-amplitude modulated fluorometer, suggesting that PHB synthesis could be enhanced by increasing the level of cellular NAD(P)H which is a limiting substrate for NADPH-dependent acetoacetyl-CoA reductase. From these results, it is likely that NAD(P)H would be a limiting factor for PHB synthesis in Synechocystis sp. PCC 6803.