• 제목/요약/키워드: public wastewater treatment plant

검색결과 50건 처리시간 0.023초

축산폐수 중의 난분해성 물질 및 암모니아 제거를 위한 Fenton 산화와 Zeolite 이온교환 공정의 적용 가능성 (Applicable Feasibility of Fenton Oxidation and Zeolite Ion Exchange Processes for Removal of Non-Biodegradable Matters and Ammonia in Livestock Wastewater)

  • 조창우;김병용;채수천;정팔진
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.600-606
    • /
    • 2007
  • Livestock wastewater containing concentrated organic matters and nutrients has been known as one of the major pollutants. It is difficult to apply the conventional activated sludge process to treat livestock wastewater because of high Non-biodegradable (NBD) matter and ammonia. The objectives of this study are to remove NBD matters including aromatic compounds and ammonia in livestock wastewater using Coagulation-Fenton oxidation-Zeolite (CFZ) processes and ascertain applicable feasibility in the field through pilot plant experiment. NBD matters and color remained in the treated water were removed over 92% by Fenton oxidation as the second treatment process. Ammonia was removed by over 99.5% in the zeolite ion exchange process as the last treatment method. From $UV_{254}$, $E_2/E_3$ ratio and GC/MS analyses of treated water at each process, the aromatic compound was converted to aliphatic and aromaticity was decreased. In pilot scale test, organics and ammonia removal efficiencies were not much different from the result of lab-scale test at various operation conditions. Furthermore, reaction time and dosage of Fenton reagent in pilot scale experiment reduced by 40 min and 50% rather than in lab-scale test. $BOD_5$, $COD_{Mn}$, SS, T-N and T-P of treated water in the pilot-scale experiment also met the effluent standards.

발포기술을 이용한 폐 LCD유리 여재의 수질정화능력 평가 (Evaluation of the Water Purification Efficiency of Waste LCD Glass Media by Using Foaming Technology)

  • 안태웅;최이송;오종민
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.369-376
    • /
    • 2010
  • The purpose of this study is to reprocess Waste-LCD(Liquid Crystal Display), to widely increase specific surface-area by foaming agent in the process of reprocessing and to use as a substrate of water treatment which is increased the ability of biological treatment, as well as to control non-point source pollutants produced by surface run off during rainfall with using this substrate, and to improve water quality of public watershed as developing substrate for water treatment to be able to purify second treated water which is exhausted at the wastewater treatment plant. The average removal efficiency of Waste-LCD that using the foaming technology was SS 71.2%, BOD 55.7%, COD 58.4%, T-N 29.5% and T-P was 50.3%. Almost Media, early stage showed low removal efficiency of SS and BOD. However, it became high when the microorganism adhered the Media. The variation of SS removal efficiency was high by inflow concentration of SS. The reason for the Media 4 showed high SS removal efficiency is that it has wide specific surface-area, and also it has a pore. All in all, it shows floating matter treatment ability not only inside but it also works outside of the substrate.

이상혐기공정의 축산폐수 공공처리시설 적용 가능성에 관한 실험적 연구 (A Study on the Evaluation of Two-Phase Anaerobic Process for Public Livestock Wastewater Treatment Plant)

  • 오성모;김문호;배윤선;박철휘
    • 상하수도학회지
    • /
    • 제21권3호
    • /
    • pp.331-339
    • /
    • 2007
  • The purpose of this study was to investigate the biodegradability and performance of organic removal and methane production rate when treating piggery wastewater using a pilot scale two-phase anaerobic system operated up to a volumetric rate of $10m^3/day$. The pilot scale two-phase anaerobic process is consisted of a continuous-flow stirred-tank reactor (CFSTR) for the acidification phase and an Upflow Anaerobic Sludge Blanket reactor (UASB) for the methanogenesis. The acidogenic reactor played key roles in reducing the periodically applied shock-loading and in the acidification of the influent organics. The acidogenic CFSTR was operated at organic loading rates (OLR) between 1.8 and $14.4kgCOD/m^3{\cdot}day$, and the UASB reactor was operated between 0.5 and $5.6kgCOD/m^3{\cdot}day$. A stable maximum biogas production rate was $81m^3/day$ and the methane conversion rate of the organic matter varied from 0.30 to $0.42L\;CH_4/g\;COD_{removed}$(0.40) at hydraulic retention time (HRT) above 3.5days. The methane contents ranged from 73 to 82% during the experimental period. It is known that most of the removed organic matter was converted to methane gas, and the produced biogas might be high quality for its subsequent use.

부산시 남부하수처리시설과 인근 하천에서 발생하는 악취물질 확산 특성 (Dispersion Characteristics of Odorous Elements from Nambu Wastewater Treatment Plant and a Nearby Streams in Busan)

  • 문성만;이형돈;조상원;강동효;박해식;오광중
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.953-962
    • /
    • 2011
  • The covered stream of cities are considered an odor source. Also, the public do not want a wastewater treatment plant(WWTP) near their properties due to the emission of odor emanating from such sources, although they play an important role in urban development. The purpose of this study is to analyze the pattern distribution of the odorous compounds from the Nambu WWTP and Youngho stream in Busan. odor sampled four times were analyzed by instrumental analysis method and indirect olfactory method. The kinds of offensive odorous compounds examined are acetaldehyde, propion aldehyde, hydrogen sulfide, methyl mercaptan, dimethyl sulfide and ammonia. Also, Concentration of air pollutants has been calculated by ISCST3 models. At the result of this study, The Nambu WWTP releases sulfur compounds. And the major odorous were hydrogen sulfide (1,475 ppb) and acetaldehyde (95 ppb) at Youngho stream. The stink which residents feel will point out the Nambu WWTP mainly if the odor is removed with the improvement of a Youngho stream. Accordingly, we should pay more attention to appropriate components to processes in odor reducing plan at Nambu WWTP.

가축분뇨처리시설과 연계한 상향류식 인공습지의 자연형 후속처리공정 적용방안에 관한 연구 (A study on application of eco-friendly follow-up process connected with livestock wastewater treatment plant using the upflow constructed wetland)

  • 최한나;조은하;강호근;박주현;강선홍
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.359-370
    • /
    • 2015
  • This study developed an up-flow wetland providing either an eco-friendly follow-up process of medium-sized public treatment facility for livestock manure or a non-point source pollution controller near livestock farms. The four bench-scale up-flow wetlands were operated with four different bed media sets. The removal efficiencies of the wetland effluent for CODCr, TN, TP, SS were 35.2 %, 29.5 %, 31.2 % and 52.2 % for set 1(Blank, without reed, with bio-ceramic), 40.6 %, 43.4 %, 42.2 % and 55.4 % for set 2(with bio-reed & without bio-ceramic), 45.2 %, 48.7 %, 46.6 % and 66.3 % for set 3(with bio-reed & bio-ceramic), 32.9 %, 27.3 %, 29.3 % and 54.1 % for Set 4(with reed & bio ceramic), respectively. The set 3 condition having a mixture of bio-reed and bio-ceramic showed the highest efficiency in the bench-scale evaluation. This study suggests a mixture of bio-reed and bio-ceramic as suitable bed media in the construction of artificial wetlands near livestock farms. Soils including the bed media were monitored during the evaluation for trace elements. Soil analysis results were satisfied with the Korean Soil Contamination Standard. This study showed that the up-flow constructed wetland was feasible to treat the effluent livestock wastewater treatment facility.

PCR-RFLP 방법을 이용한 활성 슬러지의 세균군집 분석 (Molecular Characterization of the Bacterial Community in Activated Sludges by PCR­RFLP)

  • 이현경;김준호;김치경;이동훈
    • 미생물학회지
    • /
    • 제40권4호
    • /
    • pp.307-312
    • /
    • 2004
  • 폐수처리에 중요한 역할을 담당하고 있는 세균 군집의 다양성과 폐수종류에 따른 군집차이를 알아보기 위해 분자생물학적 분석방법을 사용하였다. 국내 폐수처리장 슬러지 시료로부터 16S rDNA 클론 라이브러리를 구축하였고, HaeIII RFLP pattern과 염기서열을 분석하였다. 하수처리장 시료에서는 총 1,151개의 클론에서 699개의 서로 다른 RFLP pattern이, 화학산업 폐수처리장 시료에서는 총 1,228개의 클론에서 300개의 서로 다른 RFLP pattern이 관찰되었다. Shannon-Weiner diversity index의 계산결과 하수처리장 슬러지 시료는 8.7,화학산업 폐수처리장 슬러지 시료는 6.1로 하수처리장시료가 더 다양한 군집을 구성하고 있었다. 두 시료에서 우점하는 RFLP pattern에 해당되는 40개의 클론을 선정하여 염기서열 분석과 상동성 검색을 수행하였다. 분석된 서열의 $70\%$인 28개의 클론은 배양이 보고되지 않은 균주의 16S rRNA와 유사도가 높았고, 두 시료 모두 ${\beta}-Proteobacteria$가 우점하였다. 그러나, 하수처리장의 경우 활성슬러지에서 분리된 균주들과 유사한 군집이 많았던 반면, 화학산업 페수처리장의 경우 고온이며, 혐기성이고,탄화수소나 황이 많이 존재하는 환경에서 분리된 균주들과 유사한 군집이 많았다. 이러한 결과는 유입수의 조성에 따른 차이로 생각된다.

국내 하수처리장 관리대행 현황 및 제도 개선 방안 (The Investigation and Improvement plan of Contracting-out municipal wastewater treatment plant system in Korea)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제19권2호
    • /
    • pp.211-215
    • /
    • 2017
  • 하수처리장 운영 시장 규모는 전세계적으로 증가하고 있는 추세이다. 이에 하수처리장 관리 대행 제도는 국내 하수처리장의 효율적인 운영을 위해 도입되었지만 지속적으로 개선의 필요성이 제기되고 있다. 본 연구에서는 하수처리장 관리 제도의 활성화를 위해 현행 하수처리장 운영비용 현황 조사 및 개선 방안을 연구하였다. 하수처리장 용량이 클수록 하수처리단가가 감소하는 하는 경향을 보였다. 전체 하수처리장 운영 단가는 공기업이 가장 저렴하였지만, 유사 하수 처리장(유사 용량, 유사 공법, 유사 운영 기간)의 운영비용을 비교하였을 경우 민간 기업이 가장 저렴한 것으로 나타났다. 하수처리장 관리 및 운영 관계자들과의 면담 조사 결과 관리대행업자 선정 및 운영 비용 산정 방법 개선이 필요하다는 의견이 제시되었다. 본 연구는 하수처리장 관리 대행 활성화를 위한 방안 제시를 위한 기초 자료로 활용 될 수 있을 것으로 판단한다.

하수처리시설에서 인 고도처리를 위한 일체형 침전부상공정(SeDAF)의 응집제 주입농도 자동제어기법 검토 (Automatic control of coagulant dosage on the sedimentation and dissolved air flotation(SeDAF) process for enhanced phosphorus removal in sewage treatment facilities)

  • 장여주;정진홍;김원재
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.411-423
    • /
    • 2020
  • To remove phosphorus from the effluent of public wastewater treatment facilities, hundreds of enhanced phosphorus treatment processes have been introduced nationwide. However, these processes have a few problems including excessive maintenance cost and sludge production caused by inappropriate coagulant injection. Therefore, the optimal decision of coagulant dosage and automatic control of coagulant injection are essential. To overcome the drawbacks of conventional phosphorus removal processes, the integrated sedimentation and dissolved air flotation(SeDAF) process has been developed and a demonstration plant(capacity: 100 ㎥/d) has also been installed. In this study, various jar-tests(sedimentation and / or sedimentation·flotation) and multiple regression analyses have been performed. Particularly, we have highlighted the decision-making algorithms of optimal coagulant dosage to improve the applicability of the SeDAF process. As a result, the sedimentation jar-test could be a simple and reliable method for the decision of appropriate coagulant dosage in field condition of the SeDAF process. And, we have found that the SeDAF process can save 30 - 40% of coagulant dosage compared with conventional sedimentation processes to achieve total phosphorus (T-P) concentration below 0.2 mg/L of treated water, and it can also reduce same portion of sludge production.

수정된 MLE 공정을 이용한 Full-Scale에서의 돈사분뇨처리 (Piggery Waste Treatment using Improved MLE Process in Full-Scale)

  • 황인수;민경석
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.895-904
    • /
    • 2006
  • The improved MLE (modified Ludzack-Ettinger) process was operated for piggery waste treatment in full-scale public livestock waste treatment plant. The treated waste from bioreactor was suitable for the strict effluent standard of 200 mgCOD/L and 60 mgTN/L as it was dewatered chemically without settling tank and passed through filtration process. Though this treatment method produced a great deal of sludge ($6.4m^3\;per\;m^3$ dewatered piggery waste) it was able to accomplish predominant effluent quality by removing non-biodegradable COD and color without advanced oxidation process as ozone, fenton and etc.. The nitrogen removal efficiency of bioreactor was rapidly declined from March to May (from 0.016 to 0.005 kgN/kgVSS-day) when disinfection is in earnest as well as from warm season when reactor temperature rises higher than $35^{\circ}C$(from 0.016 to 0.008 kgN/kgVSS-day). This study proves that counterplanes for infection residuals, bioreactor temperature and dewatering sludge reduction are necessary for piggery waste treatment.

요인분석기법을 활용한 공공하수처리시설 성과평가 지표의 구성 타당성 연구 (A study on the composition validity of performance indicators for public sewage treatment plant by using factor analysis)

  • 윤여천;구자용
    • 상하수도학회지
    • /
    • 제29권5호
    • /
    • pp.583-590
    • /
    • 2015
  • Evaluation and comparison for the performance on the contracting-out became possible after the introduction of the performance indicators(PIs) in 2012 in Korea, And local governments and private companies are utilizing them as evaluation data to enhance the performance of the contracting-out. Several revisions on performance indicator were carried out by expert group on contents validity of PIs, But the review of the composition validity of PIs was not sufficient. In this study, the applicability, distinction ability and composition validity of PIs is evaluated by statistical method. From the results, Improvement of indicator is required in order to increase the interrelationship among indicators to enhance the compostion validity of indicators related with operation, sludge and water reuse.