Electric Shock Risk Assessment of the Human Body and Potential Distribution Analysis by FLUX3D in a Public Bathtub (공중욕조에서의 FLUX3D에 의한 전위분포 해석 및 인체의 전격위험성 평가)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kim, Han-Sang;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.2 s.80
    • /
    • pp.41-46
    • /
    • 2007
  • This paper considers the electrical shock risk of the human body due to underwater leakage current in such places of public baths. Many submerged electric facilities in a public bath may create a severe electric shock hazard for the human body, since wet body in an accidentally energized bathtub can result in low electrical resistance through the human body for leakage or fault currents. Therefore a major consideration, in the context of electrical safety underwater, is the shock risk to the bather as a result of electric current flowing through the water in bathtub. To assess the electric shock risk and to analyze the potential distribution in a bathtub, 2 different situation cases are set up, then experimental and simulation methods are adopted. The validity of 2 cases of simulation and experiment data in a bathtub for electric distribution underwater are compared and analyzed. Also electric shock risk assessment underwater in a real public bathtub by simulation program package, Flux 3D, was conducted herein, and the results are presented and discussed.

Evaluation on Electric Shock Risk due to the Electric Potential Distribution in Bathtub (욕조에서의 전위분포 해석을 통한 전격재해 위험성 평가)

  • Kim, Chong-Min;Kim, Han-Sang;Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.1 s.79
    • /
    • pp.40-46
    • /
    • 2007
  • It is evaluated that electric shock risk in bath so that we made and designed a bathtub which is the same size in real public bath. And then, we did an experiment, provided of electric leakage in various conditions, so we measured how to form an electric potential and knew the electric potential is formed variously under exposed conductor in bath. Also, we made certain that electric shock risk is down if we insert an insulated pipe in bathtub pipe which is prevent from being formed the electric field sharply. The results show that the increased shock risk and safe distance are estimated by the bathtub of limited width and depth, and the voltage simulated on the basis of Flux 3D concept is compared with the measured value.

Analysis of the Electric Potential distribution and Evaluation of Electric Shock Risk in Bathtub (욕조에서의 전위분포 해석 및 전격재해 위험성 평가)

  • Kim, Chong-Min;Kim, Han-Sang;Jung, Jong-Wook;Jung, Jin-Soo;Kim, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.37-40
    • /
    • 2006
  • This paper presents the evaluation electric shock risk In bath so that we made and designed a bathtub which is the same size in real public bath. and then we did an experiment, provided of electric leakage in various conditions so, we measured how to form an electric potential and knew the electric potential is formed variously under exposed conductor in bath. also we made certain that electric shock risk is down if we insert an insulated pipe in bathtub pipe which is prevent from being formed the electric field sharply.

  • PDF

Study of the Electric Shock Risk in Water at the Waterpark, Public Bath (물놀이.입욕시설에서의 수중 감전 위험성 연구)

  • Kim, Chong-Min;Kim, Han-Sang;Kim, Gi-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.93-94
    • /
    • 2006
  • This paper presents the evaluation electric shock risk in water so that we made and designed a bathtub which is the same size in real public bath. and then we did an experiment, provided of electric leakage in various conditions so, we measured how to form an electric gradient and knew the electric gradient is formed variously under exposed conductor in water. also we made certain that electric shock risk is down if we insert an insulated pipe in bathtub pipe which is prevent from being formed the electric field sharply.

  • PDF

Analysis of Electric Shock Risk of the Human Body in Underwater (수중에서의 인체에 대한 전격위험성 분석)

  • Kim, Sung-Chul;Kim, Doo-Hyun;Lee, Chong-Ho;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.26-32
    • /
    • 2006
  • The paper considers the electrical shock risk of the human body due to underwater leakage current in electric field. The characteristics of electric shock in fresh water due to the leakage of submerged electric facility in the bathtub in public baths were conducted. The exposed live electrode is modeled as a point source of electric current source. It is assumed that divergent monopole field exists in the vicinity of the current source, regardless of the presence of return electrode and insulating boundary. The electric potentials in the steel bathtub, Diesen and Mole and Flux3D program one are measured according to the distance from leakage source. The results show that the increased shock risk and safe distance are estimated by the bathtub of limited width and the voltage calculated on the basis of a divergent monopole field concept is compared with the measured value.

A Study of the Using Pattern of the Bathroom Shown in the Rural Apartment Houses (농촌공동주택(農村共同住宅) 욕실공간(浴室空間)의 이용(利用) 행태(行態) 연구(硏究))

  • Cho, Il-Howan;Choi, Hyo-Seung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.1 no.1
    • /
    • pp.129-138
    • /
    • 1999
  • The aim of this study is to obtain new design factors which can be applied to the constructing design of bathrooms. This study was especially focused on the using patterns of the bathrooms of the rural apartment houses in Chungbuk Province which have been constructed by the public program to improve old farm houses. To carry out this study, field study, questionnaire survey and personal interview have been made. The results are as follows. 1) It is essential to lay out a bathtub, because farmers need to relieve their fatigue caused by manual labor, and mostly they don't find a bathhouse in the neighborhood. 2) With the drainage way, it is necessary to equip an apparatus to collect and remove the fallen hair and garbage which usually stop up the beak. 3) Considering the using patterns of the bathrooms as the place of washing one's face, foot, hair and clothes, one more hydrant is needed in the bathroom besides the two hydrants in the washstand and bathtub.

  • PDF

A Study on the Physical Environment in 24 Hours Child Care Centers (보육환경의 방향제시를 위한 야간 보육시설에 대한 실태조사)

  • 장상옥;안경온
    • Journal of the Korean housing association
    • /
    • v.14 no.5
    • /
    • pp.47-55
    • /
    • 2003
  • This project, conducted in Korea, sought to investigate the physical environment of 24 hurs child care centers in order to suggest desirable perspective on it. For this study, documentary research, interviews and survey methods were used. Materials of the 24 hurs child care center were reviewed. The interviews and survey were conducted in 25 public and private centers in Seoul, Busan, Ulsan and Jinju. Caregivers were surveyed children's daily living and regarding the evaluation of physical environment of kitchen, bathroom and restroom of the center. The result of the documentary review indicates that there need to be increased the number of the 24 hr child care centers with quality. Mostly, caregivers were satisfied with the physical indoor environment of the center. However, they wanted the sleeping room and bathroom with bathtub for 24 hurs caring children. This result would be helpful to create useful database for planning the 24 hrs child care center.

Characterization of Legionella Isolated from the Water System at Public Facilities in Chungcheongnam-do Province (충남지역 다중이용시설의 환경수계에서 분리한 레지오넬라균의 특성 분석)

  • Cheon, Younghee;Lee, Hyunah;Nam, Hae-Sung;Choi, Jihye;Lee, Dayeon;Ko, Young-Eun;Park, Jongjin;Lee, Miyoung;Park, Junhyuk
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.472-478
    • /
    • 2021
  • Background: The Legionella case detection and notification rate have increased in public artificial water environments where people visit, including large buildings, public baths, and hospitals. Objectives: In this study, the distribution of Legionella and its epidemiologic characteristics were analyzed in the water systems of public facilities in Chungcheongnam-do Province in South Korea. Methods: Culture and PCR analysis were performed on 2,991 environmental water system samples collected from 2017 to 2019, and associations with year, facilities, seasons, and temperature of water system were statistically analyzed by using R-Studio for Windows. Descriptive data was compared using chi-square tests and independent t-tests. Results: The detection rate of Legionella increased from 3.1% in 2017 to 10.3% in 2019, appearing most frequently in the order of public baths, large-scale buildings, hospitals, and apartments. It was detected mainly in summer from June to August, over 1.0×103 CFU/L on average in 133 cases (66.5%). Lots of germs were detected in bathtub water, cooling tower water, and warm water (p<0.001), and it was detected at higher rates in the cities where multipurpose facilities were concentrated than in rural areas (p=0.018). Conclusions: This study suggests that continuous monitoring and control are required for Legionella in the water system environment of high risk facilities. Moreover, these results will be helpful to prepare efficient management plans to prevent the Legionellosis that occurs in Chungcheongnam-do Province.

Development of a Bath Assistive System with Water Temperature Monitoring to Prevent Heart Attack (수온 모니터링 기능을 탑재한 심장마비 방지용 목욕 보조 시스템)

  • Kang, So Myoung;Wei, Qun
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.242-249
    • /
    • 2019
  • Old people and patients with cardiovascular disease could die of a heart attack in the bath with heated water for a long time. Various researches have been studied to prevent these accidents from happening such as measuring the ECG signal when taking bath. However, these devices are hard to use and the higher price is not easily accepted by the public. In this paper, a low-cost and use-friendly, real time high precision water temperature monitoring device to prevent heart attack in the bath was developed. The device with waterproof design that lets the device can float on the surface of the water, and an accurate way to make water temperature measurement method was proposed by this paper that is immerging the sensor into water with 4cm depth to measure the temperature of underwater. The manufactured device was conducted to two experiments; one was to verify the basic functions of the device, and another one was for compare the proposed device with commercial products for monitoring the water temperature in the bathtub. As the experimental results shown, the proposed device has stable performance for the water temperature measurement and communicating with laptop in wireless.

Deterministic Estimation of Typhoon-Induced Surges and Inundation on Korean Coastal Regions (국내 연안 태풍 해일의 결정론적 추정 및 침수 영역 예측)

  • Ku, Hyeyun;Maeng, Jun Ho;Cho, Kwangwoo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • This research mainly focuses on examining the applicability of the deterministic model SLOSH (Sea, Lake and Overland Surges from Hurricanes) on Seas covering South Korea. Also, a simple bathtub approach which estimates coastal inundation area is validated as a first step of estimating effects of sea-level rise on the coastal cities of South Korea according to climate change. Firstly, the typhoon-induced surges are obtained from the model SLOSH by adopting historical typhoons MAEMI (0314) and BOLAVEN (1215). The results are compared to observational, typhoon-induced surge heights at several tidal stations. The coastal inundation area is estimated by comparing the maximum envelop of waves (MEOW) and the elevation of coastal land. It reproduces well the inundation area. It can be seen that this research gained applicability for estimating further potential coastal inundation with climate changes.