• Title/Summary/Keyword: proton beam

Search Result 266, Processing Time 0.025 seconds

Thin film acoustooptic beam deflector in proton-exchanged LiNbO$_{3}$ (양자교환된 LiNbO$_{3}$에서 박막도파형 음향광학 광변위기)

  • 김성국;백운석;김광택;정성갑;송재원
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.7
    • /
    • pp.94-103
    • /
    • 1995
  • Thin film acoustooptic beam deflector in proton-exchanged Y-cut LiNbO$_{3}$ was fabricated and measured. The planar waveguide was fabricated by using the proton-exchanged and annealing method in Y0cut LiNbO$_{3}$. Interdigital transducer for SAW(surface acoustic wave) was made by the laser lithography. Using above method, the thin film acoustooptic beam deflector was constructed. Its SAW wavelength was 20.mu.m at 174MHz center frequency. The interaction length between guided optical wave and SAW was 2.16mm. The measured 3dB bandwidth was 17MHz using He-Ne laser. And 70% diffraction efficiency was obtained at 970mW RF driving power.

  • PDF

Improvement of Proton Beam Quality from the High-intensity Short Pulse Laser Interaction with a Micro-structured Target

  • Seo, Ju-Tae;Yoo, Seung-Hoon;Pae, Ki-Hong;Hahn, Sang-June
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.22-27
    • /
    • 2009
  • Target design study to improve the quality of an accelerated proton beam from the interaction of a high-intensity short pulse laser with an overdense plasma slab has been accomplished by using a two-dimensional, fully electromagnetic and relativistic particle-in-cell (PIC) simulation. The target consists of a thin core part and a thick peripheral part of equivalent plasma densities, while the ratio of the radius of the core part to the laser spot size, and the position of the peripheral part relative to the fixed core part were varied. The positive effects of this core-peripheral target structure could be expected from the knowledge of the typical target normal sheath acceleration (TNSA) mechanism in a laser-plasma interaction, and were apparently evidenced from the comparison with the case of a conventional simple planar target and the case of the transversal size reduction of the simple planar target. Improvements of the beam qualities including the collimation, the forward directionality, and the beam divergence were verified by detailed analysis of relativistic momentum, angular directionality, and the spatial density map of the accelerated protons.

Experimental Evaluation of Proton Dose Calculations in Phantoms Simulating a Clinical Heterogeneity in Patients

  • Kohno, Ryosuke;Takada, Yoshihisa;Sakae, Takeji;Terunuma, Toshiyuki;Matsumoto, Keiji;Nohtomi, Akihiro;Matsuda, Hiroyuki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.208-210
    • /
    • 2002
  • In a treatment planning for actual patients with a complex internal structure, we often expect that proton beams, which pass through both a bolus and the heterogeneity in body, will form complex dose distributions. Therefore, the accuracy of the calculated dose distributions has to be verified for such a complex object. Then dose distributions formed by proton beams passing through both the bolus and phantoms simulating a clinical heterogeneity in patients were measured using a silicon semiconductor detector. The calculated results by the range-modulated pencil beam algorithm (RMPBA) produced large errors compared with the measured dose distributions since dose calculation using the RMPBA could not predict accurately the edge-scattering effect both in the bolus and in clinical heterogeneous phantoms. On the other hand, in spite of this troublesome heterogeneity, calculated results by the simplified Monte Carlo (SMC) method reproduced the experimental ones well. It is obvious that the dose-calculations by the SMC method will be more useful for application to the treatment planning for proton therapy.

  • PDF

Evaluation of Hitachi 3D Treatment Planning version 1.6

  • Fukuda, Shigekazu;Yokohama, Noriya;Maruyama, Ichiro;Kume, Kyo;Kagiya, Go;Yamamoto, Kazutaka
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.298-299
    • /
    • 2002
  • WERC (Wakasa Wan Energy Research Center) has started the proton cancer therapy since June 2002. We use Hitachi 3D treatment planning (version 1.6) that can calculate the proton dose distribution by use of the pencil beam algorithm as well as the broad beam algorithm practically fast. This treatment planning software satisfies almost functions required in the proton therapy and includes some advanced techniques such as the 3D region glowing function that can search the target region three-dimensionally based on the CT-values. In this paper, we will introduce this planning system and present our evaluation from point of view of both clinical usage and QA.

  • PDF

Fabrication and Optimization of a Fiber-optic Dosimeter for Proton Beam Therapy Dosimetry (의료용 양성자선 계측을 위한 광섬유 방사선량계의 제작 및 최적화)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Seo, Jeong-Ki;Lee, Bong-Soo;Hwang, Eui-Jung;Shin, Dong-Ho;Park, Sung-Yong
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 2010
  • In this study, we have fabricated a fiber-optic dosimeter for a proton beam therapy dosimetry. We have measured scintillating lights with the various kinds of organic scintillators and selected the BCF-12 as a sensor-tip material due to its highest light output and peak/plateau ratio. To determine the optimum diameter of BCF-12, we have measured scintillating lights according to the energy losses of proton beams in a water phantom. Also, we determined the adequate length of organic scintillator by measuring scintillating lights according to the incident angles of proton beam. Using an optimized fiber-optic dosimeter, we have measured scintillating lights according to the dose rates and monitor units of proton accelerator.

Investigating the effects of a range shifter on skin dose in proton therapy

  • Ming Wang;Lei Zhang;Jinxing Zheng;Guodong Li;Wei Dai;Lang Dong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.215-221
    • /
    • 2023
  • Proton treatment may deliver a larger dose to a patient's skin than traditional photon therapy, especially when a range shifter (RS) is inserted in the beam path. This study investigated the effects of an RS on skin dose while considering RS with different thicknesses, airgaps and materials. First, the physical model of the scanning nozzle with RS was established in the TOol for PArticle Simulation (TOPAS) code, and the effects of the RS on the skin dose were studied. Second, the variations in the skin dose and isocenter beam size were examined by reducing the air gap. Finally, the effects of different RS materials, such as polymethylmethacrylate (PMMA), Lexan, polyethylene and polystyrene, on the skin dose were analysed. The results demonstrated that the current RS design had a negligible effect on the skin dose, whereas the RS significantly impacted the isocenter beam size. The skin dose was increased considerably when the RS was placed close to the phantom. Moreover, the magnitude of the increase was related to the thickness of the inserted RS. Meanwhile, the results also revealed that the secondary proton primarily contributed to the increased skin dose.

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo;Han, Youngyih;Kim, Jinsung;Ahn, Sung Hwan;Ju, Sang Gyu;Jung, Sang Hoon;Chung, Yoonsun;Cho, Sungkoo;Jo, Kwanghyun;Shin, Eun Hyuk;Hong, Chae-Seon;Shin, Jung Suk;Park, Seyjoon;Kim, Dae-Hyun;Kim, Hye Young;Lee, Boram;Shibagaki, Gantaro;Nonaka, Hideki;Sasai, Kenzo;Koyabu, Yukio;Choi, Changhoon;Huh, Seung Jae;Ahn, Yong Chan;Pyo, Hong Ryull;Lim, Do Hoon;Park, Hee Chul;Park, Won;Oh, Dong Ryul;Noh, Jae Myung;Yu, Jeong Il;Song, Sanghyuk;Lee, Ji Eun;Lee, Bomi;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • v.33 no.4
    • /
    • pp.337-343
    • /
    • 2015
  • Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.

Measurements of X-Ray Production Cross-Sections for 0.5¡­1.2-MeV Proton Beam (0.5~l.2-MeV 양성자빔에 대한 X-선 발생단면적의 측정)

  • Hae-ill BAK;Jun-Gyo BAK
    • Nuclear Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.108-115
    • /
    • 1990
  • The measurements of X-ray production cross-sections for 0.5~1.2-MeV proton beam are carried out on Cu and Au. For this experiment, the proton tram generated from the SNU 1.5-MV Tandem Van do Graaff accelerator is Incident on the target. The X-rays and the backscattered protons from the irradiated target are detected simultaneously by the Si(Li) X-ray detector and the SSB (Silicone Surface Barrier) charged particle detector The measured values of X-ray production cross-sections are compared with other experimental values and theoretical values such as the PWBA (Plane Wave Born Approximation) and the ECPSSR(Perturbed Stationary State corrected Energy loss, Coulomb deflection, Relativistic effects) values. For measured cross-sections near 1.0- MeV proton energy, the ECPSSR (D.D. Cohenet al., 1985) shows better agreement than the PWBA. Particularly, that of Au for 1.2 MeV proton beam is 9.69$\pm$ 0.39 barns which deviates from the ECPSSR by less than 5%. and the experimental data for 0.5~1.2- MeV proton agree with most of other experimental values within 30%.

  • PDF

Investigation of Proton Irradiated Effect on n, p type Silicon by Positron Annihilation Method (양전자 소멸 측정에 의한 n, p형 실리콘 구조 특성)

  • Lee, C.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.225-232
    • /
    • 2012
  • It is described that the proton beam induceds micro-size defects and electronic deep levels in n or p type single crystal silicon. Positron lifetime and Coincidence Doppler Broadening Positron Annihilation Spectroscopy were applied to study of characteristics of p type and n type silicon samples. In this investigation the numerical analysis of the Doppler spectra was employed to the determination of the shape parameter, S, defined as the ratio between the amount of counts in a central portion of the spectrum and the total counts of whole spectrum. The samples were exposed by 3.98 MeV proton beams ranging between 0 to ${\sim}10^{14}$ particles. The S-parameter values strongly depend on the irradiated proton beam, that indicated the defects generate more. Positron lifetime shows that positrons trapped in vacancies and lifetime ${\tau}_2$ increased according to proton irradiation.