• 제목/요약/키워드: protection tube

검색결과 198건 처리시간 0.023초

열교환기 관판의 전지작용부식과 방지에 관한 연구 (A Study on the Galvanic corrosion and its Protection on Heat Exchanger Tube Plate)

  • 임우조;홍성희;윤병두
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.344-350
    • /
    • 2001
  • This paper was studied on the characteristics of galvanic corrosion and its protection on heat exchanger tube plate in the sea water. In this paper, behavior of pitting corrosion of Ni-al bronze connected with Ti tube was measured af flow velocity of 0 m/s and 2.4 m/s. To protect galvanic corrosion, the protection characteristics of Ni-Al bronze connected with Ti tube by Zn-base alloys galvanic anode and hexagonal nylon insert was investigated. Main results obtained asre al follows: 1) The galvanic corrosion of Ni-Al bronze connected with Ti-tube is more active than single Ni-al bronze. 2) As the circuit resistance increase under the cathodic protection employing Zn-base alloys galvanic anode, Ni-al bronze connected with Ti tube is cathodically unpolarized. 3) The corrosion of Ni-Al bronze connected with Ti tube by nylon insert controls approximately 73% than not nylon insert.

  • PDF

열교환기 관판의 전지작용부식과 방지에 관한 연구 (A Study on the Galvanic corrosion and its Protection on Heat Exchanger Tube Plate)

  • 임우조;홍성희;윤병두
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.345-345
    • /
    • 2001
  • This paper was studied on the characteristics of galvanic corrosion and its protection on heat exchanger tube plate in the sea water. In this paper, behavior of pitting corrosion of Ni-al bronze connected with Ti tube was measured af flow velocity of 0 m/s and 2.4 m/s. To protect galvanic corrosion, the protection characteristics of Ni-Al bronze connected with Ti tube by Zn-base alloys galvanic anode and hexagonal nylon insert was investigated. Main results obtained asre al follows: 1) The galvanic corrosion of Ni-Al bronze connected with Ti-tube is more active than single Ni-al bronze. 2) As the circuit resistance increase under the cathodic protection employing Zn-base alloys galvanic anode, Ni-al bronze connected with Ti tube is cathodically unpolarized. 3) The corrosion of Ni-Al bronze connected with Ti tube by nylon insert controls approximately 73% than not nylon insert.

The Importance of Corrosion Control and Protection Technology in the Refinery

  • Kim, Byong Mu;Oh, Sung Lyong
    • Corrosion Science and Technology
    • /
    • 제6권3호
    • /
    • pp.112-119
    • /
    • 2007
  • This paper presents the importance of corrosion control and protection technology with a real case study of heater tube rupture damaged by High temperature H2S-H2 corrosion in the refinery. The heater was operated at the Hydrocracking unit and the operation temperature and pressure was $340^{\circ}C$ and $18kg/cm^{3}$ respectively. Top side of the convection tube was thinned by high temperature hydrogen sulfide and hydrogen gas as a uniform corrosion and finally ruptured under operation pressure. Damaged area (Convection tube zone) was blocked by protection wall, so it was impossible to inspect with conventional nondestructive examination. Instead the elbow area which is out of the protection wall was inspected regularly to evaluate the corrosion rate of convection tube indirectly. However the operation temperature and the phase of the process stream was different between inside the chamber and outside the chamber. As a result, it caused severe corrosion to the horizontal convection tube inside the chamber comparing to the elbow outside the chamber. Finally convection tube was corroded more rapidly than the elbow and ruptured after 13 years operation. Because of the rupture, the heater was totally burned and the operation was stopped for 3 months until it has been reconstructed. To prevent this kind of corrosion problem and accident, corrosion control should be strengthened and protection technology should be improved.

발전용 보일러 주증기 튜브 과열방지용 오리피스 설계기법 (The design method of overheat protection orifice for power plant boiler super heated tube)

  • 김범신;유성연;하정수;김의현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.373-378
    • /
    • 2003
  • It is important that overheat protection of super heated tube in boiler operation and maintenance. The overheat of super heat tube can make damage and rupture of tube material, which causes accidental shutdown of boiler. The super heated tube overheat is almost due to the lack of uniformity of gas temperature distribution. There are two ways to protect overheat of super heated tube. The one is to control hot gas operation pattern which is temperature or flow distribution. the other is to control super heated steam flow distribution. The former is difficult than the later, because of control device design. In this paper steam flow control method which uses orifices is proposed to protect overheat of super heat tube.

  • PDF

Nonlinear Buckling Analysis of H-Type Honeycombed Composite Column with Rectangular Concrete-Filled Steel Tube Flanges

  • Ji, Jing;Xu, Zhichao;Jiang, Liangqin;Yuan, Chaoqing;Zhang, Yunfeng;Zhou, Lijian;Zhang, Shilong
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1153-1166
    • /
    • 2018
  • This paper was concerned with the nonlinear analysis on the overall stability of H-type honeycombed composite column with rectangular concrete-filled steel tube flanges (STHCC). The nonlinear analysis was performed using ABAQUS, a commercially available finite element (FE) program. Nonlinear buckling analysis was carried out by inducing the first buckling mode shape of the hinged column to the model as the initial imperfection with imperfection amplitude value of L/1000 and importing the simplified constitutive model of steel and nonlinear constitutive model of concrete considering hoop effect. Close agreement was shown between the experimental results of 17 concrete-filled steel tube (CFST) specimens and 4 I-beams with top flanges of rectangular concrete-filled steel tube (CFSFB) specimens conducted by former researchers and the predicted results, verifying the correctness of the method of FE analysis. Then, the FE models of 30 STHCC columns were established to investigate the influences of the concrete strength grade, the nominal slenderness ratio, the hoop coefficient and the flange width on the nonlinear stability capacity of SHTCC column. It was found that the hoop coefficient and the nominal slenderness ratio affected the nonlinear stability capacity more significantly. Based on the results of parameter analysis, a formula was proposed to predict the nonlinear stability capacity of STHCC column which laid the foundation of the application of STHCC column in practical engineering.

슈퍼 섬유를 활용한 일체형 Shock Energy Absorber Lanyard Protection Tube 제조 및 특성분석 (Characteristic and Development of All-in-one Shock Energy Absorber Lanyard Protection Tube used Super Fibers)

  • 조진원;권상준;김상태;염정현;강지만;지병철
    • 한국염색가공학회지
    • /
    • 제26권2호
    • /
    • pp.106-113
    • /
    • 2014
  • Work-related falls are a major problem in the construction and roofing industries. To avoid serious injury to the worker caused by high decelerations or forces, different systems to absorb the energy of a fall are implemented in personal protective equipment. In this study, shock energy absorber lanyard protection tube was prepared using high tenacity PET fiber, P-aramid fiber, and UHMWPE fiber, respectively. Dynamic load test and static load test, bursting strength test based on the Korea fall protection equipment standard(Korea Occupational Safety & Health Agency standard 2013-13) or conformity European safety test(CE : EN355) were conducted. Especially maximum arrest force by dynamic load test of energy absorber showed below 6,000N.

Al-황동의 응력부식균열 특성에 미치는 인가전위의 영향 (Effect of Impressed Potential on the SCC of Al-Brass)

  • 정해규;임우조
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.69-74
    • /
    • 2004
  • In general, the protection method of Shell and Tube Type heat exchanger for a vessel has been applied as a sacrificial anode, which is attached at the inner side of the shell. However, this is an insufficient protection method for tube. Therefore, a more suitable method, such as the impressed current cathodic protection for tube protection, is required. Al-brass is the raw material of tubes for heat exchanger of a vessel where seawater is used for cooling the water. It has a high level of heat conductivity, excellent mechanical properties, and a high level of corrosion resistance, due to a cuprous oxide (Cu$_2$O) layer against th seawater. However, in actuality, it has been reported that Al-brass tubes for heat exchanger of a vessel can produce local corrosion, such as stress corrosion cracking (SCC). This paper studied the effect of impressed potential on the stress corrosion cracking of Al-brass for impressed current cathodic protection in 3.5% NaCl +0.1% NH$_4$OH solution, under flow by a constant displacement tester. Based on the test results, the latent time of SCC, stress corrosion crack propagation, and the dezincification phase of Al-brass are investigated.

무연 방사선 차폐 시트에 대한 몬테카를로 전산모사 (Monte Carlo Simulation for Radiation Protection Sheets of Pb-Free)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.189-195
    • /
    • 2017
  • 방사선 특히, 엑스선 또는 감마선으로부터 인체를 보호하기 위해 납(Pb)으로 된 보호 장구를 광범위하게 사용해왔다. 최근 납 중독 및 환경오염의 문제로 납을 대신하는 무연 방사선 차폐재의 개발이 활발히 이루어지고 있다. 차폐재의 성능 확보를 위해서는 제작 및 평가의 순환 사이클을 반복하게 된다. 본 연구는 실제 무연 방사선 차폐소재의 제작에 앞서 차폐재의 성능을 몬테카를로 전산모사를 통해 확인함으로써 가능한 차폐소재의 조합을 연구하였다. 방사선 차폐소재의 평가에 사용되는 조건으로 엑스선관을 Geant4를 이용하여 전산모사하고 획득된 광자 스펙트럼을 이용하여 텅스텐과 비스무스의 조합에 따른 차폐소재의 성능을 평가하였다. 차폐소재의 공극에 따른 성능 저하도 평가하였다. 방사선 차폐 소재 개발 시 공극률을 줄이는 것이 중요한 인자라는 것을 알 수 있었다.

Effect of Zinc Addition in Filler Metal on Sacrificial Anode Cathodic Protection of Fin-Tube Aluminum Heat Exchanger

  • Yoon-Sik So;Eun-Ha Park;Jung-Gu Kim
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권4호
    • /
    • pp.349-360
    • /
    • 2023
  • This study investigated the tri-metallic galvanic coupling of different metals in the tubes, fillers, and fins of a heat exchanger. The goal was to prevent corrosion of the tubes using the fin as a sacrificial anode while ensuring that the filler metal has a more noble potential than the fin, to avoid detachment. The metals were arranged in descending order of corrosion potential, with the noblest potential assigned to the tube, followed by the filler metal and the fin. To address a reduction in protection current of the fin, the filler metal was modified by adding Zn to decrease its corrosion potential. However, increasing the Zn content of filler metal also increases its corrosion current. The study examined three different filler metals, considering their corrosion potential, and kinetics. The results suggest that a filler metal with 1.5 wt.% Zn addition is optimal for providing cathodic protection to the tube while reducing the reaction rate of the sacrificial anode.

해저케이블용 유연보호튜브의 기계적 성능 연구 (Mechanical Performance Study of Flexible Protection Tube for Submarine Cables)

  • 안경수;김윤재;최진욱;임진석;최성웅
    • Composites Research
    • /
    • 제37권2호
    • /
    • pp.101-107
    • /
    • 2024
  • 해저케이블은 케이블의 손상 시 높은 유지 보수 비용과 문제점들을 해결하기 위해 다양한 종류의 보호기 자재를 사용한다. 특히 파랑 및 해류 등의 외력 요소 들로부터 케이블을 보호하기 위해 사용되는 대표적인 보호기자재로 유연보호튜브를 들 수 있다. 유연보호튜브는 폴리우레탄 85A 초 탄성 재료로 구성되어 있어 기계적 거동을 계산하기 위해 실험 결과를 기반으로 한 물성치를 이용한다. 본 연구에서는 유연 보호 튜브를 대상으로 해석적 방법을 사용하여 휨 성능과 인장 성능을 살펴보았다. 해석에 사용된 물성치는 폴리우레탄 85A의 다축인장 실험을 통해 확보된 물성 값을 이용하였다. 유연보호튜브는 최대 굽힘 모멘트 기준치인 15 kN·m와 인장하중의 기준치인 50 kN에 대해 휨 성능과 인장 성능을 분석하였다. 해석 결과 유연 보호 튜브의 최대 굽힘 모멘트가 15 kN·m일 때 MBR은 13 m로 휨 성능이 확보되었으며, 인장하중이 50 kN일 때 최대 수직 변위가 968 mm를 나타내 인장성능이 확보됨을 확인할 수 있었다.