• Title/Summary/Keyword: protection rate

Search Result 1,707, Processing Time 0.036 seconds

Effects of fermented Taraxacum mongolicum by Dongchimi on protection of liver cell and immune activity (포공영(민들레)의 동치미 발효에 의한 간세포 보호 및 면역증진 효과)

  • Choi, Bog-Soo;Kim, Hye-Ja
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.11-21
    • /
    • 2014
  • Objective : This study set out to combine the treatment efficacy of Taraxacum with Dongchimi fermentation and investigate Taraxacum's effects on protection of liver cell and controlling nitric oxide(NO) through experiments, thus checking whether it had values as a physiological active matter. The experimental materials include Taraxacum Dongchimi (TD) and Taraxacum fermented by Dongchimi (TDF). As for methodology, experiments were carried out to compare TD and TDF in components, protection effects for liver cells, anticancer effects on liver cells, and protection effects for brain cells in the aspects of liver function and immunity enhancement. Method : The experimental materials include Taraxacum Dongchimi (TD) and Taraxacum fermented by Dongchimi (TDF). As for methodology, experiments were carried out to compare TD and TDF in components, protection effects for liver cells, anti-cancer effects on liver cells, and protection effects for brain cells in the aspects of liver function and immunity enhancement. Results : As shown in the chromatogram results, each valid component content increased in Taraxacum fermented by Dongchimi (TDF) for each time section. Of them, the valid component content at 36.80 minutes was approximately 2.7 times higher in TDF at 21.8% than in Taraxacum Dongchimi (TD) at 8.28%. TDF generated more excellent protection effects against the toxicity that caused oxidative damage to the liver cell(HepG2) with t-BHP than TD. The survival rate was low in TD of $100{\mu}g/m{\ell}$ and $300{\mu}g/m{\ell}$ and increased to 23.3% in TDF of $100{\mu}g/m{\ell}$. The survival rate was the highest at $300{\mu}M$ with a significant difference of 68.1%(P<0.05). Both TD and TDF showed effects of controlling nitric oxide production according to concentration with TDF recording a higher rate of controlling nitric oxide production than TD. There were significant differences(P<0.05) in the effects of controlling nitric oxide production at 200 ug/ml, 400 ug/ml in both groups. Especially the result TDF of $400{\mu}g/m{\ell}$ was thus similar to those of butein, the positive control group. Conclusion : The result of this studies is that Taraxacum fermented by Dongchimi (TDF) increased the valid component content compared with the simple mixture(TD). The findings clearly show that it is a material with the effects of improving immunity and liver cell protection. If fermentation methods are further developed to use it as a functional material, it will be subject to more opportunities of being used in other functional foods and make a contribution to integrated medicinal food development.

Dyeing Fastness and Functional Properties of Cotton Dyed with Astringent Persimmon Juice

  • Jung, Jin-Soun
    • International journal of advanced smart convergence
    • /
    • v.8 no.3
    • /
    • pp.27-38
    • /
    • 2019
  • I reviewed about dyeing fastness and functional properties of the non-mordant dyed cotton and iron mordant dyed cotton with astringent persimmon juice. In the UV-VIS spectrum of astringent persimmon juice, the maximum absorption wavelength of the juice was 272.0 nm, which was a characteristic peak of tannin. In dyeing fastness, light fastness of the non-mordant dyed cotton was a little low at grade 2~3. But by the iron mordant treatment, the light fastness was good at grade 4. Dry cleaning fastness to discoloration and contamination was excellent at grade 4~5 for both the non-mordant dyed cotton and iron-mordant dyed cotton. Their rub fastness were grade 3 and grade 2~3 respectively, in the dry condition, and grade 2~3 and grade 3 respectively, in the wet condition. In the perspiration fastness of the non-mordant dyed cotton, the discoloration from acidity and alkalinity was grade 3~4 and grade 3, respectively, and contamination from acidity and alkalinity was relatively good at grade 4. Meanwhile, in the perspiration fastness of the non-mordant dyed cotton, discoloration from acidity and alkalinity was fair, both recording grade 3~4, and contamination from acidity and alkalinity was very good, both recording grade 4~5. In the ultraviolet protection effect of the non-mordant dyed cotton and iron-mordant dyed cotton, the ultraviolet protection factor was both 50+, both of which showed an excellent ultraviolet blocking effect. And the protection rate of UV-A appeared 98.4% and 99.1%, respectively, and the protection rate of UV-B showed 98.7% and 99.2, respectively. In addition, both exhibited an excellent deodorization rate over 99.9% or more, irrespective of the passage of time. Also, both showed an excellent antimicrobial activity over 99.9% or more against Staphylococcus aureus and Klebsiella pneumoniae.

Corrosion Rate of Buried Pipeline by Induced Alternating Current (교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구)

  • Song H. S.;Kim Y. G.;Lee S. M.;Kho Y. T.;Park Y. S.
    • 한국가스학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.45-57
    • /
    • 2001
  • An alternating current (AC) corrosion using coupon has been studied. Coupons were applied in terms of AC voltage from high value to low value through the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion(: below -850mv vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relationship could be obtained statistically, in which AC corrosion rate increased linearly with effective AC current density and its slope was 0.619.

  • PDF

Characteristics of Specific Absorption Rate (SAR) in Electromagnetic (EM) Dosimetry

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.109-114
    • /
    • 2000
  • The SI unit of specific absorption rate (SAR) in W/kg in the electromagnetic (EM) field as non-ionizing radiation is exactly same as the SI unit of absorbed dose rate in Gy/s in the ionizing radiation field. The SI unit of both physical quantities can be expressed in $[m^{\cdot}s^{-3}]$. Where, the unit of absorbed dose, Gy stands for Gray. In EM biological interactions, the SAR equations are derived and the characteristics of EM field energy absorption in terms of the SAR are discussed and described on the mathematical basis.

  • PDF

Correlation Between Exposure Rate and Quasi-Effective Energy of Natural Radiation in Japan -TLD Application-

  • Nakajima, Toshiyuki
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.54-60
    • /
    • 1987
  • The quasi-exposure rate and the quasi-effective energy of the natural radiation in the field at 47 monitoring points around nuclear power plants have been studied with the pair filter thermoluminescence dosimeter system. The results of the six years observation showed that the relationship between the quasi-exposure rate $X_q$, and quasi-effective energy $E_q$ can be represented as a hyperbolic function: $X_q=A+C/(E_q-B)$, where the constants A and B correspond to the quasi-exposure rate of cosmic-rays and the minimum quasi-effective energy of natural radiation, respectively. Furthermore, the constant A is in close agreement with the values obtained by using ionization chambers and scintillation detectors. The constant B is approximately 0.68 MeV, closely corresponding to the mean energy of the photons emitted from natural uranium.

  • PDF

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.

Analysis of Effect of Surface Temperature Rise Rate of 72.5 Ah NCM Pouch-type Lithium-ion Battery on Thermal Runaway Trigger Time (72.5 Ah NCM계 파우치형 리튬이온배터리의 표면온도 상승률이 열폭주 발생시간에 미치는 영향 분석)

  • Lee, Heung-Su;Hong, Sung-Ho;Lee, Joon-Hyuk;Park, Moon Woo
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.1-9
    • /
    • 2021
  • With the convergence of the information and communication technologies, a new age of technological civilization has arrived. This is the age of intelligent revolution, known as the 4th industrial revolution. The 4th industrial revolution is based on technological innovations, such as robots, big data analysis, artificial intelligence, and unmanned transportation facilities. This revolution would interconnect all the people, things, and economy, and hence will lead to the expansion of the industry. A high-density, high-capacity energy technology is required to maintain this interconnection. As a next-generation energy source, lithium-ion batteries are in the spotlight today. However, lithium-ion batteries can cause thermal runaway and fire because of electrical, thermal, and mechanical abuse. In this study, thermal runaway was induced in 72.5 Ah NCM pouch-type lithium-ion batteries because of thermal abuse. The surface of the pouch-type lithium-ion batteries was heated by the hot plate heating method, and the effect of the rate of increase in the surface temperature on the thermal runaway trigger time was analyzed using Minitab 19, a statistical analysis program. The correlation analysis results confirmed that there existed a strong negative relationship between each variable, while the regression analysis demonstrated that the thermal runaway trigger time of lithium-ion batteries can be predicted from the rate of increase in their surface temperature.

An Improved Short Circuit Protection Scheme for IGBT Inverters (IGBT 인버터를 위한 향상된 단락회로 보호기법)

  • 서범석;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.426-436
    • /
    • 1998
  • Identification of fault current during the operation of a power semiconductor switch and activation of suitable remedial actions are important for reliable operation of power converters. A short circuit is a basic and severe fault situation in a circuit structure such as voltage source converters. This paper presents a new active protection circuit for fast and precise clamping and safe shutdown of fault currents of the IGBTs. This circuit allows operation of the IGBTs with a higher on-state gate voltage, which can thereby reduce the conduction loss in the device without compromising the short circuit protection characteristics. The operation of the circuit is studied under various conditions, considering variation of temperature, rising rate of fault current, gate voltage value, and protection circuit parameters. An evaluation of the operation of the circuit is made using IGBTs from different to confirm the effectiveness of the protection circuit.

  • PDF

Investigation on optimum protection potential of Al-Mg alloy for small ship application in sea water solution (소형선박용 Al-Mg 합금의 해양환경 중 최적 방식 전위결정에 관한 연구)

  • Kim, Seong-Jong;Jang, Seok-Ki;Kim, Jeong-Il;Ko, Jae-Yong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.23-24
    • /
    • 2005
  • This paper investigated the mechanical and electrochemical properties of Al alloys in a slow strain rate test under various potential conditions. In general, Al and Al alloys do not corrode on formation of a film that has resistance to corrosion in neutral solutions. In seawater, however, $Cl^-$ ions lead to the formation and destruction of a passive film. In a potentiostatic experiment, the current density after 1200 sec in the potential range of $-0.68{\sim}-1.5 V$ was low. Comparison of the maximum tensile strength, elongation, and time to fracture indicated that the optimum protection potential range was from -1.5 to -0.7 V(SSCE).