• Title/Summary/Keyword: protection potential

Search Result 1,225, Processing Time 0.026 seconds

Mg 합금유전양긍에 의한 온수보일러의 음극방식거동에 관한 연구 (Study on the Cathodic Protectioin Behavior of Hot Water Boiler by Mg-Alloy Galvanic Anode)

  • 정기철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 춘계학술대회 논문집(Proceeding of the KOSME 2000 Spring Annual Meeting)
    • /
    • pp.115-121
    • /
    • 2000
  • As the development of industry water quality of river is going to bad because of waste water of an industrial complex and general home agricultural chemicals exhaust of $SO_3$ and CO gas acid rain and so on. Corrosion damage of boiler factory equipment and so forth occur quickly due to using of the polluted water resulting in increasing leak accident. Especially working life of hot water boiler using the polluted water becomes more short and energy loss increases. The cathodic protection method is the most economical and reliable one to prevent corrosion damage of steel structures. Mg-base alloys galvanic anode protection of cathodic protection method is suitable for than application of hot water boiler using water with high specific resistance such as tap water. This paper is studied on the cathodic protection characteristics of how water boiler. In tap water and 0.001mol/$\ell$ NaCl solution the characteristics of anodic polarization of Mg-base alloys galvanic anode and tube material is investigated the measurement of cathodic protection potential according to the time elaspsed is carried out.

  • PDF

콘크리트 중의 철근 부식 억제를 위한 외부전원법의 효과 (Effect of Impressed Current System for Corrosion Protection of Rebars in Concrete)

  • 문한영;김성수;김홍삼
    • 콘크리트학회지
    • /
    • 제11권2호
    • /
    • pp.221-230
    • /
    • 1999
  • 콘크리트 구조물에 균열이 생겨 물과 산소의 침투확산이 용이해 지거나 또는 외부로부터 염소이온과 같은 염화물이 침투확산되어 콘크리트 중의 철근까지 도달할 경우 및 콘크리트의 중성화가 철근위치까지 진행될 경우 철근의 부동태 피막은 파괴되어 부식이 급진전 되며 콘크리트의 박리 및 탈락현상이 수반될 뿐만 아니라 구조물의 내구성이 크게 저하된다. 본 연구에서는 콘크리트 중의 철근부식을 억제하기 위한 한 방안으로 적용되는 전기방식의 이론적인 고찰과 콘크리트 내부에 다량의 염화물을 함유시키거나 또는 균열을 발생시킨 시험체에 대하여 외부전원법을 활용한 실내실험을 실시하여 철근의 방식효과에 대해 고찰하였다. 외부전원법에 의한 전기방식을 실시하여 복극량을 측정한 결과 대상 시험체 모두 NACE의 방식기준을 만족하였으며, 부식면적율의 측정결과 34 ~84%, 단면감소의 경우 84 ~ 86%의 방식효과를 확인하였다.

A Study on the Post-Weld Heat Treatment Effect to Mechanical Properties and Hydrogen Embrittlement for Heating Affected Zone of a RE 36 Steel

  • Moon, Kyung-Man;Lee, Myung-Hoon;Kim, Ki-Joon;Kim, Jin-Gyeong;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • 제2권6호
    • /
    • pp.283-288
    • /
    • 2003
  • The cathodic protection method is being widely used in marine structural steel, however a high tensile steel like RE 36 steel for marine structural steel is easy to get hydrogen embrittlement due to over protection during cathodic protection as well as preferential corrosion of HAZ(Heating Affected Zone) part. In this paper, corrosion resistance and mechanical properties such as elongation and hydrogen embrittlement were investigated with not only in terms of electrochemical view but also SSRT(Slow Strain Rate Test) method with applied constant cathodic potential, analysis of SEM fractography in case of both As-welded and PWHT(Post-Weld Heat Treatment) of $550^{\circ}C$. The best effect for corrosion resistance was apparently indicated at PWHT of $550^{\circ}C$ and elongation was increased with PWHT of $550^{\circ}C$ than that of As-welded condition. On the other hand. Elongation was decreased with applied potential shifting to low potential direction which may be caused by hydrogen embrittlement, however the susceptibility of hydrogen embrittlement was decreased with PWHT of $550^{\circ}C$ than that of As-welded condition and Q.C(quasi cleavage) fracture mode was also observed significantly according to increasing of susceptibility of hydrogen embrittlement. Eventually it is suggested that an optimum cathodic protection potential range not causing hydrogen embrittlernent is from -770 mV(SCE) to -850 mV(SCE) in As-welded condition while is from -770 mV(SCE) to -875 mV(SCE) in PWHT of $550^{\circ}C$.

매설가스배관의 음극방식이 배관의 파괴인성에 미치는 영향 (The Effects of cathodic protection on fracture toughness of buried gas pipeline)

  • 김철만;김우식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.573-578
    • /
    • 2001
  • For the corrosion protect ion of the natural gas transmission pipelines, two methods are used, cathodic protection and coating technique. In the case of cathodic protection, defects are embrittled by occurring hydrogen at the crack tip or material surface. It is however very important to evaluate whether cracks in the embrittled area can grow or not, especially in weld metal. In this work, on the basis of elastic plastic fracture mechanics, we performed CTOD test ing with varying test conditions, such as the potential and current density. The CTOD of the base steel and weld metal showed a strong dependence of the test conditions. The CTOD decreased with increasing cathodic potential and current density. The morphology of the fracture surface showed quasi-cleavage. Hydrogen introduced fractures, caused by cathodic overprotection.

  • PDF

일점접지방식을 이용한 전자교환기 방호의 실제 (Engineering Practice for ESS Protection by means of One Point Grounding System)

  • 김수형;서정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.502-505
    • /
    • 1988
  • This paper is to demonstrate the effectiveness of one point grounding in support of ESS protection. One point grounding provides for the dispatching of excess energy for protection of switching equipment and personnel from lightning discharge hazards and for a natural sink for noise from atmospheric lightning and power transients. In most ESS installations there are a number of different items that must be maintained at a common ground potential for safety, fault protection or noise reduction. The items typically consist of power systems, heating and ventilating systems, distributing frames, repeating equipmets, switching equipments, etc. Grounding system of an ESS Office is most effective when all the ground points are connected to a single, common earth. The one point grounding prvides a common reference potential, keeping all the items of telecommunications facility free from the earth current and voltage hazards.

  • PDF

사고 영향 분석을 이용한 성능위주의 내화설계 (Performance Based Design of Passive Fire Protection Using Consequence Analysis)

  • 한동훈;이종호
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.102-107
    • /
    • 2004
  • Performance based design is a recent evolutionary step in the process of designing fire protection systems. In essence, it is a logical design process resulting in a solution that achieves a specified performance. Sometimes the prescriptive solutions presented in various codes and standards are too expensive or inflexible. Often the solutions do not and enables optimization of a solution for cost and function. In this study, performance based design was carried out to determine the extent of passive fire protection for oil terminal facilities. The results of performance based design were compared with those of prescriptive code based design. Performance based design is not always more economic than prescriptive code based design but provides more reliable and effective design that is fit for the purpose.

장기간 자연 부식된 항만부두 강구조물의 방식특성 연구 (On the Corrosion Protection Characteristics of Port Steel Structures Corroded Naturally for a Long Period of Time)

  • 김기준;최영선
    • 한국항만학회지
    • /
    • 제12권1호
    • /
    • pp.145-154
    • /
    • 1998
  • Protection characteristics of the corroded steel pile which was served as a pier structure over 8 years in seawater have been examined in terms of corrosion potential, electrochemical impedance spectroscopy(EIS) and anodic/cathodic polarization curves. The steel structure was sectioned into two parts, waterline(splash zone, just above the seawater surface) and in-water(underwater), and protection characteristics for the two parts were investigated with the application of cathodic protection(CP) by sacrificial anodes using Zn and Al alloys. The main results obtained were as follows; (1) The corrosion potential of waterline zone was higher than that of in-water, which implied that the corrosion of waterline was more severe than that of in-water, (2) As a result of EIS examination, the transition period from the apparent CP to the substantial CP took about twenty to thirty days according to the corrosion condition.

  • PDF

해양구조물 RE36강의 용접부 부식거동 및 SSRT법에 의한 기계적 특성에 관한 연구 (A Study on the Corrosion Rehavior and Mechanical Property by SSRTTest of Welding Part of RE36 Steel for Marine Structure)

  • 김종성;김진경;김종호;이명훈;김영식;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.460-469
    • /
    • 2000
  • A study on the corrosion behavior of RE36 steel for marine structure was investigated with parameters such as micro-Vickers hardness, corrosion potential and corrosion current density measurement of weld metal(WM), base metal (BM) and heat affected zone(HAZ), Al anode generating current and Al anode weight loss quantity in case of cathodic protection. And we carried out slow strain rate test(SSRT) in order to research mechanical properties such as stress at maximum load, percent strain, time to fracture and strain to failure ratio etc and to find out limiting cathodic polarization potential for hydrogen embrittlement with applied cathodic polarization potential. Hardness of HAZ part was the highest among those three parts and also galvanic corrosion susceptibility was the highest in HAZ part among those three parts due to the lowest corrosion potential than other parts. However corrosion current density was the highest in WM part among those three parts. And the optimum cathodic polarization potential showing the best mechanical properties obtained by SSRT method with applied constant cathodic potential was from - 770mV to - 875mV(SCE). However it is suggested that limiting cathodic polarization potential indicating hydrogen embrittlement on the mechanical properties was under - 900mV(SCE).

  • PDF

사이버정보보호의 경제적 효과에 관한 연구 - 경제적 효과 추정방법론 수립을 중심으로 - (A Study on Economic Effects on Cyber Protection)

  • 신진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.475-478
    • /
    • 2012
  • 사이버 공간의 중요성이 커지고 그에 대한 의존성이 높아지면서 부수적으로 산업기밀유출, 사이버 테러, 개인정보유출의 문제 뿐 아니라 국가 간의 사이버 전쟁의 우려가 커지는 등 사이버 공간의 잠재적 위험성과 그에 따른 피해범위와 규모도 커지고 있는 실정이다. 그러므로 이에 대한 대비는 국가의 안보와 직결될 만큼 중요성이 커지고 있다. 따라서 정보보호체계의 확립이 시급하며 사이버 피해에 대한 체계적 이해가 필요하다. 이를 위하여 피해규모 및 피해액 추정 방법을 정리하고 이를 바탕으로 사이버 보호 대책을 수립해야 한다. 사이버보호의 경제적 효과는 사이버 보호 정책을 수립하는 기초적인 자료가 될 것이다. 본 연구에서는 사이버 피해의 체계적 이해를 바탕으로 사이버 보호의 경제적 효과에 대한 합리적인 추정방안을 연구하고자 한다.

  • PDF

Infection Risks Faced by Public Health Laboratory Services Teams When Handling Specimens Associated With Coronavirus Disease 2019 (COVID-19)

  • Wong, Chun-Kwan;Tsang, Dominic N.C.;Chan, Rickjason C.W.;Lam, Edman T.K.;Jong, Kwok-Kwan
    • Safety and Health at Work
    • /
    • 제11권3호
    • /
    • pp.372-377
    • /
    • 2020
  • Infection risks of handling specimens associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by public health laboratory services teams were assessed to scrutinize the potential hazards arising from the work procedures. Through risk assessments of all work sequences, laboratory equipment, and workplace environments, no aerosol-generating procedures could be identified except the procedures (mixing and transfer steps) inside biological safety cabinets. Appropriate personal protective equipment (PPE) such as surgical masks, protective gowns, face shields/safety goggles, and disposable gloves, together with pertinent safety training, was provided for laboratory work. Proper disinfection and good hand hygiene practices could minimize the probability of SARS-CoV-2 infection at work. All residual risk levels of the potential hazards identified were within the acceptable level. Contamination by gloved hands was considered as a major exposure route for SARS-CoV-2 when compared with eye protection equipment. Competence in proper donning and doffing of PPE accompanied by hand washing techniques was of utmost importance for infection control.