• 제목/요약/키워드: prosthetic valve

검색결과 226건 처리시간 0.027초

심초음파도를 이용한 대동맥인공판막치수 예 (Two-Dimensional Echocardiographic Prediction of Prosthetic Aortic Valve Size)

  • 박창권
    • Journal of Chest Surgery
    • /
    • 제20권4호
    • /
    • pp.655-658
    • /
    • 1987
  • Aortic annulus size was measured by two-dimensional echocardiography [2DE] in 29 patients undergoing aortic valve replacement or double valve replacement in order to predict prosthetic aortic valve size. Fifteen patients had aortic stenoinsufficiency, eleven had aortic insufficiency, and three had aortic stenosis. 2DE measurements of aortic annulus diameter, as determined from the parasternal long-axis view, demonstrated a high correlation with actual prosthetic valve size implanted at surgery [r=0.85, p<0.05]. 2DE exactly predicted actual prosthetic valve size in 8 of 29 patients [27.6%], was within 1mm of prosthetic valve size in 11 of 29 patients [37.9%], was within 2mm of prosthetic valve size in 8 of 29 patients, and was within 3mm of prosthetic valve size in 2 patients.

  • PDF

인공심장판막의 재치환술 5례 보고 (Replacement of prosthetic heart valves Report of 5 cases)

  • 신제균
    • Journal of Chest Surgery
    • /
    • 제18권4호
    • /
    • pp.655-662
    • /
    • 1985
  • From January 1985 to July 1985, prosthetic heart valves were replaced in 5 patients at Keimyung University Dongsan Medical Center. The patients included three women and two men ranging in age from 22 to 41 years. Three mitral valve replacements, one aortic valve replacement and one double valve replacement [mitral and aortic valve replacement] were done at the first valve operations. Reoperation were performed 2 to 76 months after the first operations, Prosthetic valve endocarditis occurred in 3 patients, early in one and late in two and primary valve failure occurred in 2 patients. In operative findings, vegetation in prosthetic valve endocarditis and calcification in primary valve failure were found. All except one had relatively successful operative results. One died of early fungal prosthetic valve endocarditis due to relapsed prosthetic valve endocarditis with heart failure and block.

  • PDF

인공심장판막의 재치환수술: 7례 보 (Re-replacement of prosthetic heart valves: report of 7 cases)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • 제17권1호
    • /
    • pp.3-11
    • /
    • 1984
  • Prosthetic valve replacement has resulted in marked improvement in the functional status of many patients with valvular heart disease. But valve failure from various causes has necessitated re-replacement of prosthetic valve in some of these patients. This selective group of patients has many inherent problems. This report presents our experience with seven patients who received re-replacement of prosthetic valve in the Seoul National University Hospital from 1981, to 1983. The patients included one woman and six men in the range of 9 and 49 years old. As the first valve operations, there were five MVR using tissue valves, one DVR [Bjork-Shiley and Ionescu-Shiley valve] and one case of modified Bentall operation with composite graft [Ionescu-Shiley valve]. Reoperations on prosthetic valve failure were performed 17 to 54 months after the first operation [mean 34 months]. Amon8 seven patients, there were two cases of prosthetic valve endocarditis and five cases of primary tissue failure. Gross calcification of the xenograft was found in two children with Ionescu-Shiley valve. All except one had relatively successful operative results. The unsuccessful one died intraoperatively from low output syndrome.

  • PDF

인공 심장판막의 재치환술 -수술 위험인자와 수술 결과의 분석- (Reoperation of Prosthetic Heart Valve; An Analysis of Operative Risks and Late Results)

  • 김관민
    • Journal of Chest Surgery
    • /
    • 제28권1호
    • /
    • pp.23-30
    • /
    • 1995
  • From January 1985 to December 1992, of 1257 patients who underwent a heart valve replacement 210 [16.8% underwent reoperation on prosthetic heart valves, and 6 of them had a second valve reoperation. The indications for reoperation were structural deterioration [176 cases, 81.5% , prosthetic valve endocarditis [25 cases, 11.6% , paravalvular leak [12 cases, 5.6% , valve thrombosis [2 cases, 0.9% and ascending aortic aneurysm [1 case, 0.4% . Prosthetic valve failure developed most frequently in mitral position [57.9% and prosthetic valve endocarditis and paravalvular leak developed significantly in the aortic valve [40%, 75% [P<0.02 . Mean intervals between the primary valve operation and reoperation were 105.3$\pm$28.4 months in the case of prosthetic valve failure, 61.5$\pm$38.5 months in prosthetic valve endocarditis, 26.8$\pm$31.2 months in paravalvualr leak, and 25.0$\pm$7.0 months in valve thrombosis. In bioprostheses, the intervals were in 102.0$\pm$23.9 months in the aortic valve, and 103.6$\pm$30.8 months in the mitral valve. The overall hospital mortality rate was 7.9% [17/26 : 15% in aortic valve reoperation [6/40 , 6.5% in reoperation on the mitral prostheses [9/135 and 5.7% in multiple valve replacement [2.35 . Low cardiac output syndrome was the most common cause of death [70.6% . Advanced New York Heart Association class [P=0.00298 , explant period [P=0.0031 , aortic cross-clamp time [P=0.0070 , prosthetic valve endocarditis [P=0.0101 , paravalvularr leak [P=0.0096 , and second reoperation [P=0.00036 were the independent risk factors, but age, sex, valve position and multiple valve replacement did not have any influence on operative mortality. Mean follow up period was 38.6$\pm$24.5 months and total patient follow up period was 633.3 patient year. Actuarial survival at 8 year was 97.3$\pm$3.0% and 5 year event-free survival was 80.0$\pm$13.7%. The surgical risk of reoperation on heart valve prostheses in the advanced NYHA class patients is higher, so reoperation before severe hemodynamic impairment occurs is recommended.

  • PDF

인공심방판막실패에 대한 임상적 고찰 (Reoperation for prosthetic valve failure -clinical analysis of 15 cases-)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • 제19권4호
    • /
    • pp.584-594
    • /
    • 1986
  • Despite the multivariate improvements in tissue treatment, material, and design of prosthetic heart valves in recent years, numerous complications that may lead to valve dysfunction remain a constant threat after valve replacement. Most common indications for prosthetic valve failure are primary valve failure, infective endocarditis, paravalvular leakage, and thromboembolism. From 1977 to 1986, 15 patients underwent reoperation for prosthetic valve failure in 278 cases of valve surgery. The etiology of prosthetic valve failure were primary valve failure in 12 patients [80 %], infective endocarditis in 2 patients [13.3 %], and a paravalvular leakage [6.7 %]. The average durations of implantation were 45.5 months; 53.9 months in primary valve failure, 16 months in infective endocarditis, and 4 months in paravalvular leakage. The rate of valve failure was high under age of 30 [11/15]. Calcifications and collagen disruption of prosthesis were main cause of primary valve failure in macro- & micropathology. Prosthesis used in reoperation were 5 tissue valves and 10 mechanical valves. Operative mortality were 13.3 % [2/15], due to intractable endocarditis and ventricular arrhythmia.

  • PDF

임신중 발생한 인공승모판 혈전증의 혈전 용해제를 이용한 치료 -치험 1례 보고- (Thrombolytic Therapy for Prosthetic Mitral Valve Thrombosis of Pregnant Patient -A Case Report-)

  • 김영대
    • Journal of Chest Surgery
    • /
    • 제27권10호
    • /
    • pp.858-861
    • /
    • 1994
  • Prosthetic valve thrombosis is rare but it is one of fatal complication after heart valve surgery. Improvements of the valve design and the material have decreased the frequency of thrombosis but have not eliminated completely. And some cases of prosthetic valve thrombosis during pregnancy were reported inspite of adequate anticoagulation therapy.Urgent surgical intervention is indicated for prosthetic valve thrombosis but it is associated with high operative risk, therefore medical thrombolytic therapy such as urokinase or streptokinase therapy is regarded as an alternative therapy. This is a case report of the successful thrombolytic therapy for valve thrombosis in a pregnant patient after mechanical mitral valve replacement.

  • PDF

심장판막 질환 성형술에 대한 임상적 고찰 (Reconstructive Procedures Combined with or Without Prosthetic Valve Replacement for Cardiac Valvular Lesions)

  • 김윤;조범구;홍승록
    • Journal of Chest Surgery
    • /
    • 제9권2호
    • /
    • pp.207-214
    • /
    • 1976
  • Operations for cardiac valvular disease has been progressed in various ways. Since 1949 when Lord Russel operated mitral stenosis by closed technique at Johns Hopkins Hospital then much progress has been achieved and that nowadays severely diseased cardiac valve has been replaced by prosthetic valve, which is almost ideal in hemodynamic aspect, but still it has many problems such as thromboembolism, destruction of red blood cell, pressure gradient, and disturbance of left ventricular function, so in case of delicate situations, valve replacement should be decided carefully. Besides prosthetic valve, there are some kinds of reconstructive procedures and these have been resulted in better prognosis than prosthetic valve replacement in selected cases. So, authors have reviewed 61 Cases of cardiac patients who have been operated reconstructive valvular surgery by cardiopulmonary bypass, at Yonsei University, from Jan. 1963 to Mar. 1976. Out of 61 cases, 9 patients were replaced by prosthetic valve and rest of the patients were operated upon in various reconstructive procedures such as commissurotomy, valvotomy, valvuloplasty, and annuloplasty. Twenty cases of congenital heart diseases with valvular lesion, which had been operated for valvular lesion were also included in this statistics. Out of 9 cases of prosthetic valvular replacement five cases of prosthetic valvular replacement was done combined with other reconstructive procedures after attempted valvuloplasty. Comparative prognosis of both procedures are somewhat variable by reporters, average 19% of mortality after reconstructive surgery and 38% of mortality after prosthetic valve replacement in long term results. Most common cause of death in postoperative period was low output syndrome in both cases. It seems that good preoperative evaluation and proper reconstructive surgery will afford good prognosis in selected cardiac valvular diseased patient.

  • PDF

후천성 심질환의 인공판막치환술에 대한 임상적 고찰 (Clinical Analysis of Prosthetic Valve Replacement on Acquired Heart Disease)

  • 이준영;지행옥
    • Journal of Chest Surgery
    • /
    • 제22권6호
    • /
    • pp.951-959
    • /
    • 1989
  • Between September, 1972 and September, 1989, total 359 patients were operated for acquired heart disease at Department of Thoracic and Cardiovascular Surgery, Hanyang University Hospital. A consecutive series of 293 prosthetic valve replacement was also performed during this period. The results were summarized as follows; 1. There were 141 men and 218 women, whose ages ranged from 6 to 64 years, [mean 35.5 years] 2. Out of 293 cases, mitral valve replacement was 182 cases, aortic valve replacement was 39 cases and double valve replacement was70 cases. 3. Early post-operative death was 30 cases [Mortality; 8.4 %] and late death was 9 cases in the survivors. 4. Re-operation was 30 cases and operative mortality was 10%. 5. Mean post-operative interval was 76 months. [Ranged from 216 months to 2 months] 6. Among re-operation cases, primary prosthetic valve failure was 16 cases and paravalvular leakage was 2 cases. 7. Since January 1988, 79 cases of prosthetic valve replacement were performed and then 1 case was expired. [Mortality; 1.2 %]

  • PDF

승모판막 재건술;인공판륜[prosthetic ring]을 이용한 수술례 (Mitral Valve Reconstruction; Result of Operation Using Prosthetic Ring)

  • 이재원
    • Journal of Chest Surgery
    • /
    • 제26권3호
    • /
    • pp.191-195
    • /
    • 1993
  • Among 25 consecutive cases having undergone mitral valve surgery between March 1991 and June 1992 in Gill General Hospital, 11 patients[44%] who had undergone mitral valve reconstruction using prosthetic rings is evaluated and presented. Patients` mean age is 43 + 19 years[range:16-72], and they are consisted with 4 males and 7 females. Mitral valve insufficiency is due to degenerative disease in 6 cases[55%] and rheumatic disease in 5 patients[45%]. Carpentier`s functional classification I is 2 cases, II is 6 cases, and III is 2 cases. Surgical techniques include prosthetic ring annuloplasty[11 patients, 100%], chorda shortening[6, 55%], leaflet mobilization[4,36%], new chorda formation[2, 18%], chorda transposition[1, 9%] commissurotomy[3, 27%], and papillary muscle splitting[3, 27%]. Average number of mitral anatomic lesions per patient are 2.7 and we used average 2.8 procedures upon mitral valve apparatus per patient. There were no surgical mortality and no late valve related admission during the mean follow up period of 17 months. The mean functional class[NYHA] is 2.81 preoperatively and improved to 1.10 postoperatively. Doppler echocardiography showed much improvement from grade II MR [1 case], grade III MR [1 case] and 9 cases of grade IV MR to 6 cases of patients showed no MR, only trace MR in 4 cases, and grade I MR was found only in one patient with NYHA functional class II postoperatively. The postoperative mean mitral valve area is $2.10+0.28cm^2$. We conclude that mitral reconstruction is a predictable and stable operation.

  • PDF

경식도 심초음파 검사를 이용한 판막대치술 환자의 평가 (Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement)

  • 조건현
    • Journal of Chest Surgery
    • /
    • 제24권3호
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF