• Title/Summary/Keyword: prosthetic knee

Search Result 34, Processing Time 0.028 seconds

Systematic Review and Comparative Meta-Analysis of Outcomes Following Pedicled Muscle versus Fasciocutaneous Flap Coverage for Complex Periprosthetic Wounds in Patients with Total Knee Arthroplasty

  • Economides, James M.;DeFazio, Michael V.;Golshani, Kayvon;Cinque, Mark;Anghel, Ersilia L.;Attinger, Christopher E.;Evans, Karen Kim
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.124-135
    • /
    • 2017
  • Background In cases of total knee arthroplasty (TKA) threatened by potential hardware exposure, flap-based reconstruction is indicated to provide durable coverage. Historically, muscle flaps were favored as they provide vascular tissue to an infected wound bed. However, data comparing the performance of muscle versus fasciocutaneous flaps are limited and reflect a lack of consensus regarding the optimal management of these wounds. The aim of this study was to compare the outcomes of muscle versus fasciocutaneous flaps following the salvage of compromised TKA. Methods A systematic search and meta-analysis were performed to identify patients with TKA who underwent either pedicled muscle or fasciocutaneous flap coverage of periprosthetic knee defects. Studies evaluating implant/limb salvage rates, ambulatory function, complications, and donor-site morbidity were included in the comparative analysis. Results A total of 18 articles, corresponding to 172 flaps (119 muscle flaps and 53 fasciocutaneous flaps) were reviewed. Rates of implant salvage (88.8% vs. 90.1%, P=0.05) and limb salvage (89.8% vs. 100%, P=0.14) were comparable in each cohort. While overall complication rates were similar (47.3% vs. 44%, P=0.78), the rates of persistent infection (16.4% vs. 0%, P=0.14) and recurrent infection (9.1% vs. 4%, P=0.94) tended to be higher in the muscle flap cohort. Notably, functional outcomes and ambulation rates were sparingly reported. Conclusions Rates of limb and prosthetic salvage were comparable following muscle or fasciocutaneous flap coverage of compromised TKA. The functional morbidity associated with muscle flap harvest, however, may support the use of fasciocutaneous flaps for coverage of these defects, particularly in young patients and/or high-performance athletes.

The Effect of Total Patellectomy in the Prosthetic Replacement of Proximal Tibia (경골 근위부 종양에서 인공 삽입물 사용시 슬개골 전적출술이 관절기능 회복에 미치는 영향)

  • Park, Il-Hyung;Kim, Jae-Do;Ihn, Joo-Chul;Chun, In-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.8-17
    • /
    • 1996
  • The purpose of this study is a comparative evaluation of range motion, especially extension deficit between the group of total patellectomy and that of intact patella, after reconstruction of the patellar tendon in the prosthetic replacement of a proximal tibia. Between 1990 and 1994, 15 patients who had a primary malignancy on proximal tibia were operated on. All patients were evaluated clinically and radiographically. Two patients were excluded because one had a deep infection treated with arthrodesis of the knee and the other was a composite allograft. The mean follow-up of the 13 patients was 27 months(15-47), including 10 osteosarcomas, 1 chondrosarcoma, 1 malignant fibrous histiocytoma and 1 malignant giant cell tumor. Eleven patients had a resection of the proximal tibia and 2 had an extracapsular total knee resection with distal femur. Reconstruction of the defect was done in 8 cases with a custom-made Link Endo-Model Total Rotation Knee Joint Prosthesis, and in 5 with How Medica Modular Resection System (HMRS). We used two methods to reconstruct the ligamentum patellae. Fixation of the patellar tendon to the prosthesis only with suturing and/or stapling(group SS) was done in 7. Transposition of gastrocnemius muscle to enhance fixation and to cover the prosthesis(group TG) was done in 6. Regardless of fixation methods, total patellectomy was done in 5 either to lengthen the patellar tendon or to make primary skin closure easier or for both. In 8 cases, patella was left intact or resurfaced with polyethylene prosthesis. Active extension was measured while the patient was in a sitting position. There is no statistically meaningful difference in terms of extension deficit (Wilcoxon rank test, p=0.8800) between patellectomy group and intact patella group, and between group of fixation only with suturing and that of gastrocnemius transposition. Two cases of extension deficit over 30 degree were seen in group SS and in the group of intact patella. Conclusively, total patellectomy could be an option without increasing the risk of extension deficit when primary skin closure is difficult or patellar tendon is a little bit short to be fixed. There is no rating in the Enneking system of functional evaluation that this finding into consideration.

  • PDF

Reconstruction of Extensor Mechanism After Prosthetic Replacement of The Proximal Tibia (근위 경골에 발생한 악성종양 절제 후 슬관절 신전력 재건술 -증례 보고-)

  • Park, Jong-Hoon;Oh, Jung-Moon;Kim, Jin-Wook;Lee, Soo-Yong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.120-123
    • /
    • 2004
  • Benign and malignant bone tumors occur most commonly around the knee. The proximal tibia is the most technically demanding site for limb salvage surgery. The most difficult problem using an endoprothesis for proximal tibial resection has been reconstruction of the extensor mechanism. After excision of proximal tibia, we resected distal femur and made a composite with resected distal femur, low heat treated autogenous proximal tibia and endoprothesis. Patella was fixed into the resected down-loaded distal femur. This article shows the new technique and the results of reconstruction of extensor mechanism after prosthetic replacement of the proximal tibia.

  • PDF

Gait Analysis of Patients with Tumor Prosthesis around the Knee (인공 종양대치물을 이용한 사지구제술후의 보행 분석)

  • Lee, Sang-Hoon;Chung, Chin-Youb;Kim, Han-Soo;Kim, Byung-Sung;Lee, Han-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.1
    • /
    • pp.18-25
    • /
    • 1997
  • Prosthetic replacement is one of the most common methods of reconstruction after resection of malignant tumor around the knee. Gait analysis provides a relative objective data about the gait function of patients with prosthesis. The purpose of this study was to compare the gait pattern of the patients who underwent limb salvage surgery with prosthesis for distal femur and that of patients with prosthesis for proximal tibia. This study included ten patients (4 males, 6 females, mean age 22.7 years, range 14-36) who underwent a wide resection and Kotz hinged modular reconstruction prosthesis replacement and six normal adult(Control). The site of bone tumor was the distal femur (Group 1) in six patients and proximal tibia (Group 2) in 4 patients. The follow-up period ranged from 15 to 82 months (mean : 33 months). The evaluation consisted of clinical assessment, radiographic assessment, gait analysis using VICON 370 Motion Analysis System. The gait analysis included the linear parameters such as, walking velocity, cadence, step length, stride length, stance time, swing time, single support and double support time and the three-dimensional kinematics (joint rotation angle, velocity of joint rotation) of ankle, knee, hip and pelvis in sagittal, coronal and transverse plane. For the kinetic evaluation, the moment of force (unit: Nm/kg) and power (unit: Watt/kg) of ankle, knee and hip joint in sagittal, coronal and transverse plane. In the linear parameters, cadence, velocity, step time and single support were decreased in both group 1 and group 2 compared with control. Double support decreased in group 2 compared with control significantly(p<.05). In contrast to our hypothesis, there was no significant difference between group 1 and group 2. In Kinematics, we observed significant difference (p<.05) of decreased knee flexion in loading response (G2

  • PDF

Design and Optimization of an Knee Joint of Fully-active Transfemoral Prosthesis for Stair Walking (계단 보행을 위한 능동형 대퇴의지 무릎 관절의 설계 및 최적화)

  • Ahn, Hyoung-Jong;Lee, Kwang-Hee;Hong, Yi;Lee, Chul-Hee
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2016
  • In this study, a fully active transfemoral prothesis with a knee joint is designed considering stair walking conditions. Since the torque at the knee joint required for stair walking condition is relative high compared with the one in normal walking condition, the proposed design has high torque generating mechanism. Moreover, the transfemoral prothesis is designed in compact size to reduce its weight, which is related to comfortable fit and fatigue of patients. Flat type BLDC motor is used for simple and compact structure and various components are used to generate required torque with target working angle and speed. The weight reduction of structure is carried out using optimization method after the initial design process is complete. The optimization is conducted under the load conditions of stair walking. The optimized design is validated via finite element analysis and experiments. As a result, the weight is reduced using topology and shape optimization but maintaining the safety of structure. Also the space efficiency is improved due to its compact size.

Development of Multi-rotational Prosthetic Foot for Lower Limb Amputee (하지 절단자를 위한 다축 회전이 가능한 인공발의 개발)

  • Shin, Hyunjun;Park, Jin-Kuk;Cho, Hyeon-Seok;Ryu, Jei-Cheong;Kim, Shin-Ki
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.305-313
    • /
    • 2016
  • Movements of the lower limb are important for normal walking and smooth oscillation of the center of gravity. The ankle rotations such as dorsi-flexion, plantar-flexion, inversion and eversion allows the foot to accommodate to ground during level ground walking. Current below knee (B/K) prostheses are used for replacing amputated ankle, and make it possible for amputees to walk again. However, most of amputees with B/K prostheses often experience a loss of terrain adaptability as well as stability because of limited ankle rotation. This study is focused on the development of multi-rotational prosthetic foot for lower limb amputee. Our prosthesis is possible for amputees to easily walk in level ground by rotating ankle joint in sagittal plane and adapt to the abnormal terrain with ankle rotation in coronal plane. The resistance of ankle joint in the direction of dorsi/plantar-flexion can be manually regulated by hydraulic damper with controllable nozzle. Furthermore, double layered rubber induce the prosthesis adapt to irregular ground by tilting itself in direction of eversion and inversion. The experimental results highlights the potential that our prosthesis induce a normal gait for below knee amputee.

Utility of Gait Analysis and Functional Assessment of Prosthetic Reconstruction in Bone Tumor around the Knee (슬관절 주위에 발생한 골종양 환자에서 종양 대치물을 이용한 재건술 후 기능적 평가 및 보행 분석의 유용성)

  • Lee, Jin-Ho;Seol, Young-Jun;Jung, Sung-Taek
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.18 no.2
    • /
    • pp.51-58
    • /
    • 2012
  • Purpose: This study attempts to know functional results and gait analysis usefulness in patients with bone tumor around knee joint tumors who underwent prosthesis knee joint reconstruction. Materials and Methods: Retrospective study was conducted with 7 patients out of 30 patients who underwent prosthesis knee joint reconstruction after wide marginal excision for bone tumor around knee in orthopedics of this hospital from 2001 to 2010. Functional assessment and gait analysis were perforemed. Results: For the SF-36 score, while 'role physical' and 'role emotional' items showed 100% (100 points) high scores individually, general health, physical function, vitality, and social function showed low scores. The mean score of MSTS was 88.1% (23.8 points [17-27]), indicating a relatively high score. For the gait analysis, mean gait velocity was 97.2 m/s, mean cadence was 105.6 step/min, mean stride length was 111.3 m, mean step length was 61.5 cm, swing phase was 39.8%cycle, stance phase was 60.1%cycle, mean single limb support was 37.1%cycle, mean double limb support was 13.0%cycle, and mean push off was 60.7%cycle. Conclusion: It is expected that prosthesis reconstruction after wide marginal excision for bone tumor around knee has relatively good functional results. Gait analysis was considered one of method which showed gait phase and assessed functional ability objectively by quantitative assessment post operative patient condition. It might help treatment and post operative rehabilitation planning with the functional assessment.

$^{99m}Tc$-HMPAO-labelled Leucocyte Scintigraphy in the Diagnosis of Infection after Total Knee Replacement Arthroplasty (인공슬관절 전치환술 환자에서 $^{99m}Tc$-HMPAO-백혈구 스캔을 이용한 인공관절 감염의 진단)

  • Park, Dong-Rib;Kim, Jae-Seung;Ryu, Jin-Sook;Moon, Dae-Hyuk;Bin, Seong-Il;Cho, Woo-Shin;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.413-421
    • /
    • 1999
  • Purpose: This study was performed to evaluate the usefulness of $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy Materials and Methods: The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age. 65 years) who had total knee replacement arthroplasty. After injection of $^{99m}Tc$-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection. Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Results: Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positives, one false positive and three true negatives in Group B, and six true negatives and two false positives in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively Conclusion: $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  • PDF

Visually Indistinguishable Intractable Neuroma Management after Below Knee Amputation: A Case Report (하퇴부 절단술 후 육안적으로 발견하기 어려운 난치성 신경종 처치: 증례 보고)

  • Shin, Seong Kee;Kim, Ki Chun;Roh, Youngju;Kim, Jongkyu
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.212-215
    • /
    • 2019
  • Symptomatic neuromas after amputation can be troublesome to treat and make it difficult to properly fit a brace. Surgical management is required when conservative management such as prosthetic socket modification or local injections fail. However, small cutaneous nerves adhere to adjacent soft tissue and they are difficult to locate. The authors suggest that ultrasonography guided tattoo localization using a charcoal suspension is useful to find a visually indistinguishable neuroma.

Evaluation of Intralimb Coordination in Transfemoral Amputee during Level Walking (대퇴절단인의 보행 시 하지 내 협응성 평가)

  • Chang, Yoon-hee;Jeong, Bo-ra;Kang, Sung-jae;Ryu, Jei-cheong;Mun, Mu-seong;Ko, Chang-Yong
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 2016
  • The aims of this study were to evaluate the joint coordination between hip and knee joints in the transfemoral amputees, and its symmetry between sound and prosthetic limbs. Seven transfemoral amputees ($46.4{\pm}10.7-year-old$, $174.8{\pm}3.5cm$, $78.3{\pm}9.7kg$) and 7 able bodies ($24.0{\pm}4.5-year-old$, $174.5{\pm}5.9cm$, $66.9{\pm}9.4Kg$) participated in this study. They walked at a self-selected walking speed across a 10m level ground. Simultaneously angle and angular velocity in the hip and knee joint were measured by motion analysis system. Then continuos relative phase(CRP), standard deviations of CRP (CRP_SD) and symmetry index(SI) were calculated. In able bodies, there were no differences of the parameters between left and right limb(all p>0.05). However, significant differences between sound and prosthetic limb in most of the parameters, except for CRP for stance phase were shown (all p<0.05). There were differences in all SI between transfemoral amputees and able bodies (p<0.05). In conclusion, joint coordination was altered in transfemoral amputee during level walking and shown in interlimb asymmetry.