• 제목/요약/키워드: prostatectomy

검색결과 57건 처리시간 0.039초

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • 제21권6호
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

Incidentally Detected Adenocarcinoma Prostate in Transurethral Resection of Prostate Specimens: a Hospital Based Study from India

  • Varghese, Jophy;Kuruvilla, Priya Mariam;Mehta, Nisarg;Rathore, Ranjeet Singh;Babu, Manas;Bansal, Devesh;Pillai, Biju;Sam, Mohan P;Krishnamorthy, H
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권4호
    • /
    • pp.2255-2258
    • /
    • 2016
  • Background: Awareness about prostate cancer has increased in the community, and prostate cancer screening examinations, including prostate specific antigen (PSA) assays, are now widely available. Prior to the PSA era, up to 27% of prostate cancers were detected incidentally at the time of transurethral resection of prostate (TURP). After PSA testing became widely available, the incidence of incidentally detected carcinoma prostate in TURP specimens without prior diagnosis reduced to 5-13%. However, the incidence of incidentally detected carcinoma prostate has been reported to vary across the globe since various factors can influence the identification of this malignancy in TURP specimens. In this paper, we focus on rates of incidentally detected prostate cancer in TURP specimens in our hospital and correlate it with various parameters. Materials and Methods: This retrospective study of histopathological findings of biopsy specimens was conducted for patients undergoing TURP during a period of 5 years from April 2010. The inclusion criteria were patients diagnosed with benign prostatic hyperplasia (BPH) (digital rectal examination (DRE) not showing any abnormally hard areas and normal age adjusted PSA values). Patients with elevated PSA, abnormal DRE, documented urinary tract infection and proved adenocarcinoma prostate (CaP) were excluded from the study. The total weight of prostatectomy specimen, occurrence of carcinoma prostate in the chips, percentage of total tissue resected showing malignancy and Gleason's scores were recorded. Results: A total of 597 patients belonging to the inclusion criteria were studied. The incidence of occult CaP in the study group was 5.2 % (31/597). Out of these, 8 belonged to T1a and 23 belonged to T1b stages. The age group 70 - 79 years had the maximum incidence of occult CaP. It was observed that the clinical grading of prostate did not have a bearing on the incidence of occult CaP whereas the weight of resected specimen correlated with the incidence of CaP. The incidence of occult CaP was greater with low volume prostates (<20 g). (P=0.15). Conclusions: The rate of incidentally detected adenocarcinoma prostate in patients undergoing TURP for clinically diagnosed BPH was found to be only 5.2 % in our study which is low when compared with similar studies done elsewhere. The age of the patient and weight of the resected specimen correlated with incidence of occult prostate cancer. The clinical grading of prostate by DRE however, demonstrated no correlation.

한국에서 Biochemical Recurrence의 진단에 대한 혈액 및 영상의학적 검사에 관한 비뇨기종양을 전공하는 의사의 트렌드에 대한 고찰 (The Trend of Uro-Oncologist About Blood Test and Imaging Studies for the Diagnosis of Biochemical Recurrence in Korea)

  • 서성필;김원태;강호원;김용준;이상철;김원재;김소영;박종혁;윤석중
    • 대한비뇨기종양학회지
    • /
    • 제15권3호
    • /
    • pp.131-136
    • /
    • 2017
  • Purpose: The aim of this study is to investigate the criteria of biochemical recurrence (BCR) and follow-up periods and methods with and without blood and imaging test of urologic oncology before established guidelines of prostate cancer in Korea. Materials and Methods: In December 2015, we sent the questionnaire to urologic oncologist in academic hospital and received the answer from 108 urologic oncologist (50%). Also, we analyzed the data of 1,141 patients underwent radical prostatectomy in 2005 from Korean Medical Insurance. Results: In follow-up, 72 physicians (66.7%) performed blood test every 3 months, 51 physicians (47.2%) performed imaging study in case of BCR. Bone scan was the most common imaging study in the follow-up (74 physicians, 68.5%). But, bone scan was only performed in case of BCR (43 physicians, 39.8%). The criteria of BCR was PSA 0.2 ng/mL (75 physician, 69.4%), 76 physicians (70.4%) was performed different follow-up according to risk of patients. In Korean Medical Insurance data analysis, PSA were performed average 2 times every year and magnetic resonance imaging, computed tomography, Bone scan were performed average 0.1, 0.2, 0.1 times every year, respectively. Conclusions: The criteria of BCR and the follow-up of prostate cancer patients in Korea were similar Korean prostate cancer guidelines. Blood and imaging test might be increased compared to 10 years ago, it is necessary to compare the Korean Medical Insurance data between 10 years ago and present.

면역방사계수측정법의 민감도 향상을 위한 변법의 평가 (Evaluation of Variation Method to Improve the Sensitivity of Immunoradiometric Assay)

  • 권원현;강미지;김나경;박지솔;김정인;이경재
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose The concentration of PSA (Prostate Specific Antigen) after radical prostatectomy in prostate cancer patients is a predictor of biochemical recurrence, and the AUA (American Urological Association) is defined as biochemical recurrence when the concentration of PSA is measured at 0.2 ng/mL or more, and when the concentration is measured at 0.2 ng/mL or more at the retest. This standard is also applied our hospital. In this laboratory, the PSA reagent using IRMA (Immunoradiometric Assay) is used, and the sensitivity at a very low value was not as good as the reagent used in the department of laboratory medicine. This study aims to increase the reliability of the results by improving the precision and sensitivity of very low values. Materials and Methods As a reagent for the study, PSA reagent using IRMA was used. As a method to improve the precision and sensitivity of very low values, a variation method on the serum volume(25 uL, 50 uL, 100 uL, 200 uL) was studied, and variation usefulness evaluation was conducted. The evaluation items were compared the results of precision, analytical sensitivity, recovery rate, dilution test, high-dose hook effect test, parallel test and very low concentration values(n = 20). Results The validation results were displayed in the order of 25 uL, 50 uL, 100 uL, 200 uL. As the serum volume increased, it was confirmed that CV (Coefficient of Variation)(%) improved. Analytical sensitivity(ng/mL) was 0.038, 0.041, 0.017, 0.015 and recovery rate(%) was 101±3, 101±3, 99±2, 97±4. very low concentration values(ng/mL) between each volume(n=20) were 0.135±0.068, 0.076±0.050, 0.048±0.034, 0.046±0.034. and high dose hook effect appeared as the serum volume increased. Conclusion Through the variation usefulness evaluation, it was confirmed that as the serum volume increased, the precision and sensitivity improved at very low concentration values. However, it is necessary to pay special attention to the occurrence of high-dose hook effect as the serum volume increases. In the case of tests that requires very low concentration values, it is thought that the reliability of the result will be increased if the variation method is properly used after the variation usefulness evaluation.

  • PDF

Use of Imaging and Biopsy in Prostate Cancer Diagnosis: A Survey From the Asian Prostate Imaging Working Group

  • Li-Jen Wang;Masahiro Jinzaki;Cher Heng Tan;Young Taik Oh;Hiroshi Shinmoto;Chau Hung Lee;Nayana U. Patel;Silvia D. Chang;Antonio C. Westphalen;Chan Kyo Kim
    • Korean Journal of Radiology
    • /
    • 제24권11호
    • /
    • pp.1102-1113
    • /
    • 2023
  • Objective: To elucidate the use of radiological studies, including nuclear medicine, and biopsy for the diagnosis and staging of prostate cancer (PCA) in clinical practice and understand the current status of PCA in Asian countries via an international survey. Materials and Methods: The Asian Prostate Imaging Working Group designed a survey questionnaire with four domains focused on prostate magnetic resonance imaging (MRI), other prostate imaging, prostate biopsy, and PCA backgrounds. The questionnaire was sent to 111 members of professional affiliations in Korea, Japan, Singapore, and Taiwan who were representatives of their working hospitals, and their responses were analyzed. Results: This survey had a response rate of 97.3% (108/111). The rates of using 3T scanners, antispasmodic agents, laxative drugs, and prostate imaging-reporting and data system reporting for prostate MRI were 21.6%-78.9%, 22.2%-84.2%, 2.3%-26.3%, and 59.5%-100%, respectively. Respondents reported using the highest b-values of 800-2000 sec/mm2 and fields of view of 9-30 cm. The prostate MRI examinations per month ranged from 1 to 600, and they were most commonly indicated for biopsy-naïve patients suspected of PCA in Japan and Singapore and staging of proven PCA in Korea and Taiwan. The most commonly used radiotracers for prostate positron emission tomography are prostate-specific membrane antigen in Singapore and fluorodeoxyglucose in three other countries. The most common timing for prostate MRI was before biopsy (29.9%). Prostate-targeted biopsies were performed in 63.8% of hospitals, usually by MRI-ultrasound fusion approach. The most common presentation was localized PCA in all four countries, and it was usually treated with radical prostatectomy. Conclusion: This survey showed the diverse technical details and the availability of imaging and biopsy in the evaluation of PCA. This suggests the need for an educational program for Asian radiologists to promote standardized evidence-based imaging approaches for the diagnosis and staging of PCA.

Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구 (A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006)

  • 김진희;김재성;하성환;신성수;박원;조재호;서창옥;오영택;신세원;김재철;장지영;남택근;최영민;김일한
    • Radiation Oncology Journal
    • /
    • 제26권2호
    • /
    • pp.96-103
    • /
    • 2008
  • 목적: 한국인의 비뇨기암 중 1990년 말부터 발병률이 빠르게 증가되고 있는 전립선암의 치료에 있어 전국 각 병원의 방사선종양학과에서 시행되고 있는 방사선치료의 현황을 조사, 분석하고 이를 바탕으로 전립선암의 Patterns of care study(PCS) 개발의 기본 자료로 이용하고자 한다. 대상 및 방법: 전국 13개 대학병원의 방사선종양학과 전문의들의 설문조사를 통하여 각 의사들의 전립선암에 대한 치료 현황과 치료원칙을 수집, 분석하였다. 결과: 진단은 초음파유도 조직생검을 적게는 6개에서 12개 부위, 평균 9개 부위에서 얻고 있으며 진단당시의 영상학적 검사는 대부분에서 자기공명영상과 전신골스캔을 사용하고 있다. 방사선치료를 시행할 때 내부고정물과 외부고정물은 각각 61.5%, 76.9%에서 사용하며 방사선치료의 임상표적부위는 병원마다 다양하게 시행하고 있었다. 전골반 방사선치료는 76.9%에서 $45{\sim}50.4$ Gy를, 정낭의 방사선치료는 92.3%에서 시행하고 있으나 총방사선량은 $54{\sim}73.8$ Gy로 다양하였다. 근치적인 방사선치료의 방사선량은 저위험군에서 고위험군으로 갈수록 증가하였으나 병원간의 차이가 $60{\sim}78.5$ Gy로 넓었다. 세기조절 방사선치료를 시행하는 병원은 53.8%로 반 수 이상에서 시행하고 있으며 총방사선량은 70 Gy이상 이었다. 동시추가분할선량법(SIB; simultaneous integrated boost)을 시행하는 병원은 3곳으로 표적부피와 방사선량이 다양하였다. 전립선 전적출술 후 생화학적 재발의 경우 84.6%의 병원에서 방사선치료를 시행하고 있으며 방사선치료 조사야는 전골반와부터 전립선부위까지 다양하며 총방사선량도 다양하였다. 결론: 전국 13개 병원의 전립선암의 방사선 치료현황을 볼 때 계속 증가하는 전립선암에 대한 전국병원의 방사선치료의 patterns of care study가 필요하며 이를 토대로 전립선암 방사선치료의 guideline을 제시할 필요가 있겠다.

전립선암 발견을 위한 계산형 확산강조영상 b2000과 실제 획득한 b2000 영상의 비교 (Comparison of Computed Diffusion-Weighted Imaging b2000 and Acquired Diffusion-Weighted Imaging b2000 for Detection of Prostate Cancer)

  • 김연정;김승호;백태욱;박형인;임윤정;정현경;김주연
    • 대한영상의학회지
    • /
    • 제83권5호
    • /
    • pp.1059-1070
    • /
    • 2022
  • 목적 계산형 확산강조영상 b2000과 실제 획득한 확산강조영상 b2000 사이에 전립선암 발견을 위한 민감도 및 관찰자 간 일치도를 비교하였다. 대상과 방법 근치적 전립선 절제술 및 확산강조영상(b, 0, 100, 1000, 2000 s/mm2)을 포함한 수술 전 3 Tesla 자기공명영상을 통해 전립선암으로 진단받은 총 88명의 환자가 연구에 포함되었다. 계산형 확산강조영상 b2000은 실제 획득한 확산강조영상 b0, 100, 1000으로부터 단일 지수 감쇠 모델에 의해 계산되었다. 두 명의 독립된 검토자가 4주 간격으로 무작위 순서로 두 영상 세트를 검토하여, 가장 큰 종양에 대해 관심 영역을 그렸고, Prostate Imaging-Reporting and Data System 2.1에 기반한 점수를 기록하였다. 전층 절편 조직 검사가 참고 기준으로 제공되었다. 결과 연구에 포함된 환자의 글리슨 점수는 6 (n = 16), 7 (n = 53), 8 (n = 9), 9 (n = 10)로 구성되었다. 두 명의 검토자 모두 계산형 확산강조영상 b2000과 실제 획득한 확산강조영상 b2000 간 전립선암 발견에 대한 민감도 차이는 없었다(검토자 1, 모두 94% [83/88]; 검토자 2, 모두 90% [79/88], 모두 p = 1.000). 관찰자 간 PI-RADS 점수에 대한 일치도는 계산형 확산강조영상에서 0.422 (95% 신뢰구간, 0.240-0.603), 실제 획득한 확산강조영상에서 0.495 (95% 신뢰구간, 0.308-0.683)였다. 결론 계산형 확산강조영상 b2000과 실제 획득한 확산강조영상 b2000은 전립선암 발견 민감도에 차이가 없고, 관찰자 간 일치도는 유지되었다.