• Title/Summary/Keyword: properties of expansion

Search Result 1,555, Processing Time 0.025 seconds

Application of In-Situ Mixing Hydration Accelerator on Polymer Modified Concrete for Bonded Concrete Overlay (접착식 콘크리트 덧씌우기를 위한 초속경화 첨가재 현장 혼합 폴리머 개질 콘크리트의 적용성 연구)

  • Kim, Young Kyu;Hong, Seong Jae;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.85-95
    • /
    • 2015
  • PURPOSES : Recently, bonded concrete overlay has been used as an alternative solution in concrete pavement rehabilitation since its material properties are similar to those of the existing concrete pavements. Deteriorated concrete pavements need rapid rehabilitation in order to prevent traffic jams on Korean expressways. Moreover, speedy and effective repair methods are required. Therefore, the use of bonded concrete overlay with ultra-rapid hardening cement has increased in an effort to reopen promptly the expressways in Korea. However, mobile mixer is required for ultra-rapid hardening cement concrete mixing in the construction site. The use of mobile mixer causes various disadvantages aforementioned such as limitation of the construction supply, open-air storage of mixing materials, increase in construction cost, and etc. In this study, therefore, hydration accelerator in-situ mixing on polymer modified concrete produced in concrete plant is attempted in order to avoid the disadvantages of existing bonded concrete overlay method using ultra-rapid hardening cement. METHODS : Bonded concrete overlay materials using ultra-rapid hardening cement should be meet all the requirements including structural characteristics, compatibility, durability for field application. Therefore, This study aimed to evaluate the application of hydration accelerator in-situ mixing on polymer modified concrete by evaluating structural characteristics, compatibility, durability and economic efficiency for bonded concrete overlay. RESULTS : Test results of structural characteristics showed that the compressive, flexural strength and bond strength were exceed 21MPa, 3.15MPa and 1.4MPa, respectively, which are the target strengths of four hours age for the purpose of prompt traffic reopening. In addition, tests of compatibility, such as drying shrinkage, coefficient of thermal expansion and modulus of elasticity, and durability (chloride ions penetration resistance, freezing-thawing resistance, scaling resistance, abrasion resistance and crack resistance), showed that the hydration accelerator in-situ mixing on polymer modified concrete were satisfied the required criteria. CONCLUSIONS : It was known that the hydration accelerator in-situ mixing on polymer modified concrete overlay method was applicable for bonded concrete overlay and was a good alternative method to substitute the existing bonded concrete overlay method since structural characteristics, compatibility, durability were satisfied the criteria and its economic efficiency was excellent compare to the existing bonded concrete overlay methods.

A Study on the Prolonged Time Heat Resistance of Shielding Materials Based on Modified and Novolac Type Epoxy Resin (개질 및 노블락형 에폭시수지 차폐재의 장기내열성에 관한 연구)

  • Cho, Soo-Haeng;Oh, Seung-Chul;Do, Jae-Bum;Ro, Seung-Gy;Park, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.884-888
    • /
    • 1998
  • Effects of heating time under high temperature on the thermal and mechanical properties of neutron shielding materials based on modified (KNS-102), hydrogenated(KNS-106) bisphenol-A type epoxy resin and phenol-novolac(KNS-611) type epoxy resin for radioactive material shipping casks have been investigated. At early stages, the initial decomposition temperatures of the shielding materials of KNS-102, KNS-106 and KNS-611 increased with the heating time under high temperature, but it was rarely affected by the heating time in the later stages. In addition, the thermal conductivities of KNS-102 and KNS-106 decreased with heating time, but that of KNS-611 increased with the heating time. On the contrary, the thermal expansion coefficients of neutron shielding materials decreased with increase of heating time. At the high temperature, the tensile strength and flexural strength of the shielding materials of KNS-102 and KNS-611 increased with heating time, but those of KNS-106 decreased with increase of heating time. And the heating time under high temperature on the neutron shielding materials did not show measurable loss of weight and hydrogen content.

  • PDF

Model for fiber Cross-Sectional Analysis of FRP Concrete Members Based on the Constitutive Law in Multi-Axial Stress States (다축응력상태의 구성관계에 기초한 FRP 콘크리트 부재의 층분할 단면해석모델)

  • 조창근;김영상;배수호;김환석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.892-899
    • /
    • 2002
  • Among the methods for enhancement of load-carrying capacity on flexural concrete member, recently, a concept is being investigated which replaces the steel in a conventional reinforced concrete member with a fiber reinforced polymer(FRP) shell. This study focuses on modeling of the structural behavior of concrete surrounded with FRP shells in flexural bending members. A numerical model of fiber cross-sectional analysis is proposed to predict the stress and deformation state of the FRP shell and concrete. The stress-strain relationship of concrete confined by a FRP shell is formulated to be based on the constitutive law of concrete in multi-axial compressive stress state, in assuming that the compression response is dependent on the radial expansion of the concrete. To describe the FRP shell behavior, equivalent orthotropic properties of in-plane behavior from classical lamination theory are used. The present model is validated to compare with the experiments of 4-point bending tests of FRP shell concrete beam, and has well predicted the moment-curvature relationships of the members, axial and hoop strains in the section, and the enhancement of confinement effect in concrete surrounded by FRP shell.

Microstructures and Hardness of Al-Si Coated 11%Cr Ferritic Stainless Steel, 409L GTA Welds (Al-Si 용융도금된 11%Cr 페라이트 스테인리스강, STS409L GTA 용접부의 미세조직과 경도)

  • Park, Tae-Jun;Kong, Jong-Pan;Na, Hye-Sung;Kang, Chung-Yun;Uhm, Sang-Ho;Kim, Jeong-Kil;Woo, In-Su;Lee, Jong-Sub
    • Journal of Welding and Joining
    • /
    • v.28 no.3
    • /
    • pp.92-98
    • /
    • 2010
  • Ferritic stainless steels, which have relatively small thermal expansion coefficient and excellent corrosion resistance, are increasingly being used in vehicle manufacturing, in order to increase the lifetime of exhaust manifold parts. But, there are limits on use because of the problem related to cosmetic resistance, corrosions of condensation and high temperature salt etc. So, Aluminum-coated stainless steel instead of ferritic stainless steel are utilized in these parts due to the improved properties. In this investigation, Al-8wt% Si alloy coated 409L ferritic stainless steel was used as the base metal during Gas Tungsten Arc(GTA) welding. The effects of coated layer on the microstructure and hardness were investigated. Full penetration was obtained, when the welding current was higher than 90A and the welding speed was lower than 0.52m/min. Grain size was the largest in fusion zone and decreased from near HAZ to base metal. As welding speed increased, grain size of fusion zone decreased, and there was no big change in HAZ. Hardness had a peak value in the fusion zone and decreased from the bond line to the base metal. The highest hardness in the fusion zone resulted from the fine re-precipitation of the coarse TiN and Ti(C, N) existed in the base metal during melting and solidification process and the presence of fine $Al_2O_3$ and $SiO_2$ formed by the migration of the elements, Al and Si, from the melted coating layer into the fusion zone.

Durability Properties of Ultra Rapid Hardening Mortar Produced with Alumina-based Binder for Repairing Sewage Treatment Pipes (하수관거 보수용 알루미나계 결합재 초속경 모르타르의 내구 특성)

  • Eun-Ho, Kim;Byung-Jae, Lee;Sun-Mok, Lee;Yun-Yong, Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.482-488
    • /
    • 2022
  • In this study, the durability of ultra rapid hardening mortar for sewage pipe was evaluated by type of mortar binder. As a result of analyzing the internal structure for each type of mortar, it was confirmed that Al2(OH)3 was generated in the internal structure of the CAC-based mortar, and its corrosion resistance was superior to that of other types of mortar. As a result of the compressive strength test, OPC had the tsmallest strength, followed by CAC100 > CAC100P > CAC80. This trend was similar to the previous study results. Chloride ion penetration resistance and freeze-thaw test showed similar trends. That is, CAC and C12A7 were better than OPC, and CSA was worse than OPC. This is mostly beacuse of cracks caused by expansion of CSA-based mortar. CAC100P mix showed the best chemical resistance. It is thought that this is because the alumina gel formed inside the mortar and the polymer combine to make the internal structure more dense.

The Configuration and Polyelectrolyte Behavior of Carboxymethyl Chitin in Low Concentration Solution (저농도 용액에서의 Carboxymethyl Chitin의 사슬배좌와 전해질 거동)

  • PARK Seong-Min;LEE Keun-Tae;KIM Sang-Moo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.4
    • /
    • pp.451-456
    • /
    • 1995
  • To elucidate the intrinsic rheological properties of carboxymethyl chitin (CM-chitin) from the shell of red snow cyab (Chinonecetes japonicus), the configuration and polyelectrolyte behavior of CM-chitin in low concentration solution were investigated. Unperturbed dimensions were ranged from $127{\AA}\;to\;113{\AA}$ as root mean square end-to-end distance$(r_0)$, $52{\AA}$ to $46{\AA}$ as radius of gyration$(S_0)$. The intramolecular expansion tarter(a) was not varied with molecular weight and was 2.1. And effective bond length $(b_0)$ was $14.5{\AA}$. In perturbed condition, Flory constant was $2.35\times10^{21}$. When ionic strength were 0.02 and 1.0, intrinsic viscosity were 1.95dl/g and 1,06 dl/g, respectively. These results suggested that CM-chitin is a polyelectrolyte in aqueous media. At infinite ionic strength, intrinsic viscosity was 0.91dl/g. The intrinsic stiffness of CM-chitin backbone was estimated by evaluating the stiffness parameter (B) as 0.11 and agreed well with the results of k-carrageenan.

  • PDF

Behavior of Fire Resistance Engineered Cementitious Composites(FR-ECC) under Fire Temperature (화재 온도를 받는 고인성.고내화성 시멘트 복합체의 거동)

  • Han, Byung-Chan;Kwon, Young-Jin;Kim, Jae-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.189-197
    • /
    • 2007
  • Concrete tunnel lining must be designed to having the fireproof performance because the lining are sometimes exposed to very high temperature due to traffic accident. Such fire temperature may cause explosion of concrete, or collapse of tunnel structure. The purpose of this study is to obtain the fundamental fireproof behavior of fire resistance-engineered cementitious composites(FR-ECC) under fire temperature in order to use the fire protection material in tunnel lining system. The present study conducted the experiment to simulate fire temperature by employing 2 types of FR-ECC and investigated experimentally the explosion and cracks in heated surface of these FR-ECC. Employed temperature curve were hydro carbon(HC, ECl) criterion, which are severe in various criterion of fire temperature. The numerical analysis is carried out the nonlinear transient heat flow analysis and verified against the experimental data. The complex features of behavior in fire conditions, such as thermal expansion, plasticity, cracking or crushing, and material properties changing with temperature are considered. By the use of analytical model, the concrete tunnel subjected to fire loads were analyzed and discussed. With comparison of current concrete materials and FR-ECC, the experimental and analytical results of FR-ECC shows the better fire resistance performance than the other.

Effect of Binder and Electrolyte on Electrochemical Performance of Si/CNT/C Anode Composite in Lithium-ion Battery (리튬이온 이차전지에서 Si/CNT/C 음극 복합소재의 전기화학적 성능에 대한 바인더 및 전해액의 효과)

  • Choi, Na Hyun;Kim, Eun Bi;Yeom, Tae Ho;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.327-333
    • /
    • 2022
  • In this study, silicon/carbon nanotube/carbon (Si/CNT/C) composites for anode were prepared to improve the volume expansion of silicon used as a high-capacity anode material. Si/CNT were prepared by electrostatic attraction of the positively charged Si and negatively charged CNT and then hydrothermal synthesis was performed to obtain the spherical Si/CNT/C composites. Poly(vinylidene fluoride) (PVDF), polyacrylic acid (PAA), and styrene butadiene rubber (SBR) were used as binders for electrode preparation, and coin cell was assembled using 1.0 M LiPF6 (EC:DMC:EMC = 1:1:1 vol%) electrolyte and fluoroethylene carbonate (FEC) additive. The physical properties of Si/CNT/C anode materials were analyzed using SEM, EDS, XRD and TGA, and the electrochemical performances of lithium-ion batteries were investigated by charge-discharge cycle, rate performance, dQ/dV and electrochemical impedance spectroscopy tests. Also, it was confirmed that both capacity and rate performance were significantly improved using the PAA/SBR binder and 10 wt% FEC-added electrolyte. It is found that Si/CNT/C have the reversible capacity of 914 mAh/g, the capacity retention ratio of 83% during 50 cycles and the rate performance of 70% in 2 C/0.1 C.

Formation of a large-scale quasi-circular flare ribbon enclosing three-ribbon through two-step eruptive flares

  • Lim, Eun-Kyung;Yurchyshyn, Vasyl;Kumar, Pankaj;Cho, Kyuhyoun;Kim, Sujin;Cho, Kyung-Suk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.42.1-42.1
    • /
    • 2016
  • The formation process and the dynamical properties of a large-scale quasi-circular flare ribbon were investigated using the SDO AIA and HMI data along with data from RHESSI and SOT. Within one hour time interval, two subsequent M-class flares were detected from the NOAA 12371 that had a ${\beta}{\gamma}{\delta}$ configuration with one bipolar sunspot group in the east and one unipolar spot in the west embedded in a decayed magnetic field. Earlier M2.0 flare was associated with a coronal loop eruption, and a two-ribbon structure formed within the bipolar sunspot group. On the other hand, the later M2.6 flare was associated with a halo CME, and a quasi-circular ribbon developed encircling the full active region. The observed quasi-circular ribbon was strikingly large in size spanning 650" in north-south and 500" in east-west direction. It showed the well-known sequential brightening in the clockwise direction during the decay phase of the M2.6 flare at the estimated speed of 160.7 km s-1. The quasi-circular ribbon also showed the radial expansion, especially in the southern part. Interestingly, at the time of the later M2.6 flare, the third flare ribbon parallel to the early two-ribbon structure also developed near the unipolar sunspot, then showed a typical separation in pair with the eastern most ribbon of the early two ribbons. The potential field reconstruction based on the PFSS model showed a fan shaped magnetic configuration including fan-like field lines stemming from the unipolar spot and fanning out toward the background decayed field. This large-scale fan-like field overarched full active region, and the footpoints of fan-like field lines were co-spatial with the observed quasi-circular ribbon. From the NLFF magnetic field reconstruction, we confirmed the existence of a twisted flux rope structure in the bipolar spot group before the first M2.0 flare. Hard X-ray emission signatures were detected at the site of twisted flux rope during the pre-flare phase of the M2.0 flare. Based on the analysis of both two-ribbon structure and quasi-circular ribbon, we suggest that a tether-cutting reconnection between sheared arcade overarching the twisted flux rope embedded in a fan-like magnetic field may have triggered the first M2.0 flare, then secondary M2.6 flare was introduced by the fan-spine reconnection because of the interaction between the expanding field and the nearby quasi-null and formed the observed large-scale quasi-circular flare ribbon.

  • PDF

Quality Characteristics of Jeungpyun Prepared by Rice Sourdough (Rice Sourdough를 첨가한 증편의 품질특성)

  • Oh, Chul-Hwan;Oh, Nam-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1215-1221
    • /
    • 2009
  • The purpose of this work was to improve the quality of Jeungpyun made with rice sourdough, which was prepared using a mixed culture of Saccharomyces cerevisiae (S. cerevisiae) and Leuconostoc mesenteroides (L. mesenteroides) strains, and to also develop a new process for Jeungpyun preparation using the rice sourdough. The Jeungpyun was manufactured through proofing for 3 hr at $30^{\circ}C$ and steaming steps after mixing the ingredients, including pre-fermented rice sourdough, rice powder and water. After proofing, the expansion ratio of the Jeungpyun dough ranged from 109 to 135% and the pH was decreased to pH 3.80$\sim$4.09. The volumes of the Jeungpyun samples prepared with rice sourdough were 18$\sim$45% greater than that of the control. In particular, the Jeungpyun made with rice sourdough containing 10% brown rice (CM-10) had a significantly greater volume (266 mL). Also the rice sourdough Jeungpyun samples had well developed dense porous structures compared to the control. According to sensory evaluations, the sample prepared with rice sourdough containing 10% brown rice was preferred. Finally, the physical quality (texture properties) and microbiological shelf-life of the Jeungpyun was improved by using the rice sourdough.