• Title/Summary/Keyword: projection geometry

Search Result 80, Processing Time 0.018 seconds

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF

AN ASSESSMENT OF THE SHORT-TERM EFFECT OF PERIODONTAL FLAP SURGERY BY DIGITAL SUBTRACTION RADIOGRAPHY (계수공제영상 방사선 측정법을 이용한 치주판막술 후 치조골 변화의 평가)

  • Jin, Yoo-Nam;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.595-604
    • /
    • 1993
  • Since $Gr{\"{o}}nadhl$ et al introduced a digital subtraction radiography into periodontal dignosis in 1983, many reports using this system has aimed to assess the peroiodontal disease activity and the alveolar bone changes after periodontal treatment. The present study was performed to evaluate the usefulness of digital subtraction radiography for asessing an alveolar bone changes in 3 months after periodontal flap surgery. Serial intraral raiographs were taken from 5 normal subjects and 6 periodontally diseased patients using customized bite blocks attached to film holder in fxation device and digitized by image processing system(consisting of IBM 386, digital frame grabber, CCD camera, Image-pro II software). And the reference parameters were measured by pixel unit and compared with respective radiographs. The serial radiographs showed a little and statistically insignificant difference in reference paramenters. The conventional intraoral radiographs, the subtraction images and the clor enhanced subtraction images were reviewed by 4 examiners and the examiner's agreement rates were compared. The subtraction images and its color enhanced images showed higher examiner's agreement rate than the conventional radiographs. And the propotions of sites diagnosed with bone loss or gain after periodontal surgery were highter in the subtraction images and its color enhanced images than in the conventional radiographs. Especially, in color enhanced images, the unber of bone agin sites tended to increase according to post-surgery periods. These results indicate that projection geometry could be standardized with the divice used in this study, and the subtraction radiography may be useful to assess an alveolar bone changes after periodntal flap surgery.

  • PDF

Efficient Determination of Iteration Number for Algebraic Reconstruction Technique in CT (CT의 대수적재구성기법에서 효율적인 반복 횟수 결정)

  • Joon-Min, Gil;Kwon Su, Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.141-148
    • /
    • 2023
  • The algebraic reconstruction technique is one of the reconstruction methods in CT and shows good image quality against noise-dominant conditions. The number of iteration is one of the key factors determining the execution time for the algebraic reconstruction technique. However, there are some rules for determining the number of iterations that result in more than a few hundred iterations. Thus, the rules are difficult to apply in practice. In this study, we proposed a method to determine the number of iterations for practical applications. The reconstructed image quality shows slow convergence as the number of iterations increases. Image quality 𝜖 < 0.001 was used to determine the optimal number of iteration. The Shepp-Logan head phantom was used to obtain noise-free projection and projections with noise for 360, 720, and 1440 views were obtained using Geant4 Monte Carlo simulation that has the same geometry dimension as a clinic CT system. Images reconstructed by around 10 iterations within the stop condition showed good quality. The method for determining the iteration number is an efficient way of replacing the best image-quality-based method, which brings over a few hundred iterations.

Bone changes around the maxillary posterior teeth opposing the implants in mandible: a clinical study (하악 임플란트에 대합되는 상악 구치의 주변골 변화에 대한 임상연구)

  • Park, Chan-Jin;Huh, Yoon-Hyuk;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.301-309
    • /
    • 2015
  • Purpose: When the edentulous area is restored by implant prostheses, the opposing hypofunctioned teeth will receive physiologic mechanical stimuli. This study evaluated the bone changes around the maxillary teeth opposing an implant restoration installed in the mandibular posterior area. Materials and Methods: Radiographs of the opposing teeth were taken at prostheses delivery (baseline), 3 and 6 months later. A customized film holding device was fabricated to standardize the projection geometry for the serial radiographs of the opposing teeth. The gray values of the region of interest of each digital image were compared according to time. Repeated measured analysis of variance was performed at the 95% significance level. Results: The gray values of the alveolar bone around the antagonist teeth of implants increased with time. The changes in gray values of the middle area were greater than those of the crestal area. However, the gray values of the mesial and distal areas were not different. The changes in gray values were different according to the unloaded time. Conclusion: A change in bone tissue will occur if a proper physiologic load is again applied to the bone tissues around a hypofunctioned tooth.

ALVEOLAR BONE CHANGES AROUND THE NATURAL TEETH OPPOSING THE POSTERIOR IMPLANTS IN MANDIBLE (임플랜트로 수복된 하악 구치부에 대합되는 자연치 주변의 골변화)

  • Jung, Won-Mo;Kim, Dae-Gon;Yi, Yang-Jin;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.263-273
    • /
    • 2007
  • Statement of problem: Alteration of tooth function is assumed to be changed by stress/strain on the adjacent alveolar bone, producing changes in morphology similar to those described for other load-bearing bones. When teeth are removed, opposing teeth will not be functioned. When edentulous area is restored by implant prostheses, opposing teeth will be received physiologic mechanical stimuli. Purpose: The aim of this study was to evaluate the bone changes around the teeth opposing implant restoration installed mandibular posterior area. Material and method: Eight patients who had mandibular posterior edentulous area were treated with implants. Radiographs of the opposing teeth were taken at implant prostheses delivery(baseline), 3 months, and 6 months later. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of opposing teeth. Direct digital image was obtained. Gray values of region of interest at each digital image were measured and compared according to time lapse. Repeated measured analysis of variance and post-hoc Scheffe's test were performed at the 95% significance level. Results: Alveolar bone changes around the natural teeth opposing the posterior implant in mandible showed statistically significant difference compared to control group(P<0.05). And gray values of alveolar bone around the teeth opposing implants were increased. There were no statistically significant differences of alveolar bone changes between crestal group and middle group and between mesial group and distal group according to time lapse(P>0.05). There were no statistically significant differences of alveolar bone changes among mesial-crestal group, mesial-middle group, distal-crestal group, distal-middle group, and control group(P>0.05). Conclusion: Alveolar bone around the natural teeth opposing the implant prosthesis showed gradual bony apposition.

Identification of Subsurface Discontinuities via Analyses of Borehole Synthetic Seismograms (시추공 합성탄성파 기록을 통한 지하 불연속 경계면의 파악)

  • Kim, Ji-Soo;Lee, Jae-Young;Seo, Yong-Seok;Ju, Hyeon-Tae
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.457-465
    • /
    • 2013
  • We integrated and correlated datasets from surface and subsurface geophysics, drilling cores, and engineering geology to identify geological interfaces and characterize the joints and fracture zones within the rock mass. The regional geometry of a geologically weak zone was investigated via a fence projection of electrical resistivity data and a borehole image-processing system. Subsurface discontinuities and intensive fracture zones within the rock mass are delineated by cross-hole seismic tomography and analyses of dip directions in rose diagrams. The dynamic elastic modulus is studied in terms of the P-wave velocity and Poisson's ratio. Subsurface discontinuities, which are conventionally identified using the N value and from core samples, can now be identified from anomalous reflection coefficients (i.e., acoustic impedance contrast) calculated using a pair of well logs, comprising seismic velocity from suspension-PS logging and density from logging. Intensive fracture zones identified in the synthetic seismogram are matched to core loss zones in the drilling core data and to a high concentration of joints in the borehole imaging system. The upper boundaries of fracture zones are correlated to strongly negative amplitude in the synthetic trace, which is constructed by convolution of the optimal Ricker wavelet with a reflection coefficient. The standard deviations of dynamic elastic moduli are higher for fracture zones than for acompact rock mass, due to the wide range of velocities resulting from the large numbers of joints and fractures within the zone.

Influence of Regularization Parameter on Algebraic Reconstruction Technique (대수적 재구성 기법에서 정규화 인자의 영향)

  • Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.679-685
    • /
    • 2017
  • Computed tomography has widely been used to diagnose patient disease, and patient dose also increase rapidly. To reduce the patient dose by CT, various techniques have been applied. The iterative reconstruction is used in view of image reconstruction. Image quality of the reconstructed section image through algebraic reconstruction technique, one of iterative reconstruction methods, was examined by the normalized root mean square error. The computer program was written with the Visual C++ under the parallel beam geometry, Shepp-Logan head phantom of $512{\times}512$ size, projections of 360, and detector-pixels of 1,024. The forward and backward projection was realized by Joseph method. The minimum NRMS of 0.108 was obtained after 10 iterations in the regularization parameter of 0.09-0.12, and the optimum image was obtained after 8 and 6 iterations for 0.1% and 0.2% noise. Variation of optimum value of the regularization parameter was observed according to the phantom used. If the ART was used in the reconstruction, the optimal value of the regularization parameter should be found in the case-by-case. By finding the optimal regularization parameter in the algebraic reconstruction technique, the reconstruction time can be reduced.

Structural Geometry, Kinematics and Microstructures of the Imjingang Belt in the Munsan Area, Korea (임진강대 문산지역의 구조기하, 키네마틱스 및 미세구조 연구)

  • Lee, Hyunseo;Jang, Yirang;Kwon, Sanghoon
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.271-283
    • /
    • 2021
  • The Imjingang Belt in the middle-western Korean Peninsula has tectonically been correlated with the Permo-Triassic Qinling-Dabie-Sulu collisional belt between the North and South China cratons in terms of collisional tectonics. Within the belt, crustal-scale extensional ductile shear zones that were interpreted to be formed during collapsing stage with thrusts and folds were reported as evidence of collisional events by previous studies. In this study, we tried to understand the nature of deformation along the southern boundary of the belt in the Munsan area based on the interpretations of recently conducted structural analyses. To figure out the realistic geometry of the study area, the down-plunge projection was carried out based on the geometric relationships between structural elements from the detailed field investigation. We also conducted kinematic interpretations based on the observed shear sense indicators from the outcrops and the oriented thin-sections made from the mylonite samples. The prominent structures of the Munsan area are the regional-scale ENE-WSW striking thrust and the N-S trending map-scale folds, both in its hanging wall and footwall areas. Shear sense indicators suggest both eastward and westward vergence, showing opposite directions on each limb of the map-scale folds in the Munsan area. In addition, observed deformed microstructures from the biotite gneiss and the metasyenite of the Munsan area suggest that their deformation conditions are corresponding to the typical mid-crustal plastic deformation of the quartzofeldspathic metamorphic rocks. These microstructural results combined with the macro-scale structural interpretations suggest that the shear zones preserved in the Munsan area is mostly related to the development of the N-S trending map-scale folds that might be formed by flexural folding rather than the previously reported E-W trending crustal-scale extensional ductile shear zone by Permo-Triassic collision. These detailed examinations of the structures preserved in the Imjingang Belt can further contribute to solving the tectonic enigma of the Korean collisional orogen.

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry ($PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발)

  • Cho, Woong;Lee, Jaegi;Kim, Hyun Suk;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.233-241
    • /
    • 2014
  • The aim of this study is to develop a new software tool for 3D dose verification using $PRESAGE^{REU}$ Gel dosimeter. The tool included following functions: importing 3D doses from treatment planning systems (TPS), importing 3D optical density (OD), converting ODs to doses, 3D registration between two volumetric data by translational and rotational transformations, and evaluation with 3D gamma index. To acquire correlation between ODs and doses, CT images of a $PRESAGE^{REU}$ Gel with cylindrical shape was acquired, and a volumetric modulated arc therapy (VMAT) plan was designed to give radiation doses from 1 Gy to 6 Gy to six disk-shaped virtual targets along z-axis. After the VMAT plan was delivered to the targets, 3D OD data were reconstructed from 512 projection data from $Vista^{TM}$ optical CT scanner (Modus Medical Devices Inc, Canada) per every 2 hours after irradiation. A curve for converting ODs to doses was derived by comparing TPS dose profile to OD profile along z-axis, and the 3D OD data were converted to the absorbed doses using the curve. Supra-linearity was observed between doses and ODs, and the ODs were decayed about 60% per 24 hours depending on their magnitudes. Measured doses from the $PRESAGE^{REU}$ Gel were well agreed with the TPS doses at central region, but large under-doses were observed at peripheral region at the cylindrical geometry. Gamma passing rate for 3D doses was 70.36% under the gamma criteria of 3% of dose difference and 3 mm of distance to agreement. The low passing rate was resulted from the mismatching of the refractive index between the PRESAGE gel and oil bath in the optical CT scanner. In conclusion, the developed software was useful for 3D dose verification from PRESAGE gel dosimetry, but further improvement of the Gel dosimetry system were required.