• 제목/요약/키워드: progressive collapse resistance

검색결과 42건 처리시간 0.024초

Effect of unequal spans on the collapse behavior of multi-story frames with reduced beam section connections

  • Zheng Tan;Wei-hui Zhong;Bao Meng;Li-min Tian;Yao Gao;Yu-hui Zheng;Hong-Chen Wang
    • Steel and Composite Structures
    • /
    • 제50권1호
    • /
    • pp.107-122
    • /
    • 2024
  • Following an internal column failure, adjacent double-span beams above the failed column will play a critical role in the load transfer and internal force redistribution within the remaining structure, and the span-to-depth ratios of double-span beams significantly influence the structural resistance capacity against progressive collapse. Most existing studies have focused on the collapse-resistant performances of single-story symmetric structures, whereas limited published works are available on the collapse resistances of multi-story steel frames with unequal spans. To this end, in this study, numerical models based on shell elements were employed to investigate the structural behavior of multi-story steel frames with unequal spans. The simulation models were validated using the previous experimental results obtained for single- and two-story steel frames, and the load-displacement responses and internal force development of unequal-span three-story steel frames under three cases were comprehensively analyzed. In addition, the specific contributions of the different mechanism resistances of unequal-span, double-span beams of each story were separated quantitatively using the energy equilibrium theory, with an aim to gain a deeper level of understanding of the load-resistance mechanisms in the unequal-span steel frames. The results showed that the axial and flexural mechanism resistances were determined by the span ratio and linear stiffness ratio of double-span beams, respectively.

Anti-collapse performance analysis of unequal span steel-concrete composite substructures

  • Meng, Bao;Li, Liangde;Zhong, Weihui;Tan, Zheng;Zheng, Yuhui
    • Steel and Composite Structures
    • /
    • 제39권4호
    • /
    • pp.383-399
    • /
    • 2021
  • In the study, three 1:3-scale unequal span steel-concrete composite substructures with top-seat angle and double web angle connection were designed and identified as specimens GTSDWA-0.6, GTSDWA-1.0, and GTSDWA-1.4. Pseudo-static tests and refined numerical model analysis were conducted to examine the anti-progressive collapse performance of a semi-rigid steel-concrete composite substructure. The results indicated that the failure modes of the three specimens revealed that the fracture occurred in the root of the long leg of the top/seat angle in tension at the connection. With increases in the span ratio of the left and right composite beams, the bearing capacities of the composite substructures decreased, and the corresponding displacement increased. With respect to GTSDWA-0.6 and GTSDWA-1.4, the resistance due to the short composite beam corresponded to 62% and 60%, respectively, and the total resistance provided by the short composite beam exceeded that of the long composite beam. With respect to GTSDWA-1.0, the resistance due to the left and right composite beams was similar. All three specimens underwent the flexure mechanism and flexure-axial mixed mechanism stages. They resisted the external load mainly via the flexure mechanism. Moreover, the addition of stiffeners on both sides of the top and seat angles is advantageous in terms of improving the collapse resistance and ductility of unequal span composite substructures.

A novel design method for improving collapse resistances of multi-story steel frames with unequal spans using steel braces

  • Zheng Tan;Wei-hui Zhong;Bao Meng;Shi-chao Duan;Hong-chen Wang;Xing-You Yao;Yu-hui Zheng
    • Steel and Composite Structures
    • /
    • 제47권2호
    • /
    • pp.253-267
    • /
    • 2023
  • The bearing capacities resisted by the two-bay beams of multi-story planar frames with unequal spans under column removal scenarios differ considerably owing to the asymmetric stress on the left and right beams connected to the failed column and cause the potential for beams with larger span-to-depth ratios to be unable to exert effectively, which is disadvantageous for resisting the vertical load in unequal-span frame structures. To address this problem, the structural measure of adding braces to the weak bays of multi-story unequal-span frames was proposed, with the objective of achieving a coordinated stress state in two-bay beams with unequal spans, thereby improving the collapse resistance of unequal-span frame structures. Before conducting the numerical simulation, the modeling methods were verified by previous experimental results of two multi-story planar frames with and without steel braces. Thereafter, the effects of the tensile and compressive braces on the collapse behavior of the frame structures were elucidated. Then, based on the mechanical action laws of the braces throughout the collapse process, a detailed design method for improving the collapse resistance of unequal-span frame structures was proposed. Finally, the proposed design method was verified by using sufficient example models, and the results demonstrated that the design method has good application prospects and high practical value.

Identification of progressive collapse pushover based on a kinetic energy criterion

  • Menchel, K.;Massart, T.J.;Bouillard, Ph.
    • Structural Engineering and Mechanics
    • /
    • 제39권3호
    • /
    • pp.427-447
    • /
    • 2011
  • The progressive collapse phenomenon is generally regarded as dynamic. Due to the impracticality of nonlinear dynamic computations for practitioners, an interest arises for the development of equivalent static pushover procedures. The present paper proposes a methodology to identify such a procedure for sudden column removals, using energetic evaluations to determine the pushover loads to apply. In a dynamic context, equality between the cumulated external and internal works indicates a vanishing kinetic energy. If such a state is reached, the structure is sometimes assumed able to withstand the column removal. Approximations of these works can be estimated using a static computation, leading to an estimate of the displacements at the zero kinetic energy configuration. In comparison with other available procedures based on such criteria, the present contribution identifies loading patterns to associate with the zero-kinetic energy criterion to avoid a single-degree-of-freedom idealisation. A parametric study over a family of regular steel structures of varying sizes uses non-linear dynamic computations to assess the proposed pushover loading pattern for the cases of central and lateral ground floor column failure. The identified quasi-static loading schemes are shown to allow detecting nearly all dynamically detected plastic hinges, so that the various beams are provided with sufficient resistance during the design process. A proper accuracy is obtained for the plastic rotations of the most plastified hinges almost independently of the design parameters (loads, geometry, robustness), indicating that the methodology could be extended to provide estimates of the required ductility for the beams, columns, and beam-column connections.

Collapse-resistant performance of a single-story frame assembly and multi-story sub-frame under an internal column-removal scenario

  • Zhong, Wei-hui;Tan, Zheng;Tian, Li-min;Meng, Bao;Zheng, Yu-hui;Daun, Shi-chao
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.663-679
    • /
    • 2021
  • To elucidate the differences in the collapse behavior between a single-story beam-column assembly and multi-story frame, two 1/3-scale two-bay composite frames, including a single-story composite beam-column assembly and a three-story composite sub-frame, were designed and quasi-statically tested. The load-displacement responses, failure modes, and internal force development of the two frames were analyzed and compared in detail. Furthermore, the resistance mechanisms of the two specimens were explored, and the respective contributions of different load-resisting mechanisms to the total resistances were quantitatively separated to gain deeper insights. The experimental tests indicated that Vierendeel action was present in the two-dimensional multi-story frames, which led to an uneven internal force distribution among the three stories. The collapse resistance of TSDWA-3S in the flexural stage was not significantly increased by the structural redundancy provided by the additional story, as compared to that of TSDWA-1S. Although the development of the load response was similar in the two specimens at flexural stage, the collapse mechanisms of the multi-story composite frame were much more complicated than those of the single-story beam-column assembly, and the combined action between stories was critical in determining the internal force redistribution and rebalancing of the remaining structure.

Effect of column loss location on structural response of a generic steel moment resisting frame

  • Rezvani, Farshad Hashemi;Jeffers, Ann E.;Asgarian, Behrouz;Ronagh, Hamid Reza
    • Steel and Composite Structures
    • /
    • 제25권2호
    • /
    • pp.217-229
    • /
    • 2017
  • The effect of column loss location on the structural response of steel moment resisting frames (MRF) is investigated in this study. A series of nonlinear static and dynamic analyses were performed to determine the resistance of a generic frame to an arbitrary column loss and detect the structural members that are susceptible to failure progression beyond that point. Both force-controlled and deformation-controlled actions based on UFC 4-023-03 and ASCE/SEI 41-06 were implemented to define the acceptance criteria for nine APM cases defined in this study. Results revealed that the structural resistance against an arbitrary column loss in the top story is at least 80% smaller than that of the bottom story. In addition, it was found that the dynamic increase factor (DIF) at the failure point is at most 1.13.

Determination of limiting temperatures for H-section and hollow section columns

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • 제13권4호
    • /
    • pp.309-325
    • /
    • 2012
  • The risk of progressive collapse in steel framed buildings under fire conditions is gradually rising due to the increasing use of combustible materials. The fire resistance of such steel framed buildings is evaluated by fire tests. Recently, the application of performance based fire engineering makes it easier to evaluate the fire resistance owing to various engineering techniques and fire science. The fire resistance of steel structural members can be evaluated by the comparison of the limiting temperatures and maximum temperatures of structural steel members. The limiting temperature is derived at the moment that the failure of structural member results from the rise in temperature and the maximum temperature is calculated by using a heat transfer analysis. To obtain the limiting temperatures for structural steel of grades SS400 and SM490 in Korea, tensile strength tests of coupons at high temperature were conducted. The limiting temperatures obtained by the tensile coupon tests were compared with the limiting temperatures reported in the literature and the results of column fire tests under four types of loading with different load ratios. Simple limiting temperature formulas for SS400 and SM490 steel based on the fire tests of the tensile coupons are proposed. The limiting temperature predictions using the proposed formulas were proven to be conservative in comparison with those obtained from H-section and hollow section column fire tests.

Column-loss response of RC beam-column sub-assemblages with different bar-cutoff patterns

  • Tsai, Meng-Hao;Lua, Jun-Kai;Huang, Bo-Hong
    • Structural Engineering and Mechanics
    • /
    • 제49권6호
    • /
    • pp.775-792
    • /
    • 2014
  • Static loading tests were carried out in this study to investigate the effect of bar cutoff on the resistance of RC beam-column sub-assemblages under column loss. Two specimens were designed with continuous main reinforcement. Four others were designed with different types of bar cutoff in the mid-span and/or the beam-end regions. Compressive arch and tensile catenary responses of the specimens under gravitational loading were compared. Test results indicated that those specimens with approximately equal moment strength at the beam ends had similar peak loading resistance in the compressive arch phase but varied resistance degradation in the transition phase because of bar cutoff. The compressive bars terminated at one-third span could help to mitigate the degradation although they had minor contribution to the catenary action. Among those cutoff patterns, the K-type cutoff presented the best strength enhancement. It revealed that it is better to extend the steel bars beyond the mid-span before cutoff for the two-span beams bridging over a column vulnerable to sudden failure. For general cutoff patterns dominated by gravitational and seismic designs, they may be appropriately modified to minimize the influence of bar cutoff on the progressive collapse resistance.

Histological and Ultrastructural Study of Susceptible and Age-related Resistance Responses of Pepper Leaves to Colletotrichum cocodes Infection

  • Hong, Jeum-Kyu;Lee, Yeon-Kyeong;Jeun, Yong-Chull;Hwang, Byung-Kook
    • The Plant Pathology Journal
    • /
    • 제17권3호
    • /
    • pp.128-140
    • /
    • 2001
  • Infection of pepper leaves by Colletotrichum cocodes at the two- and eight-leaf stages caused susceptible and resistant lesions 96 h after inoculation, respectively. At the two-leaf stage, progressive symptom development occurred on the infected leaves. In contrast, localized necrotic spots were characteristic symptoms at the eight-leaf stage. Infected leaves at the two-leaf stage exhibited cell death accompanied by the accumulation of autofluorescent compounds. At the eight-leaf stage, pepper leaves infected by the anthracnose fungus displayed localized autofluorescence from the symptoms. Infection of pepper leaves by C. cocodes at the two-leaf stage resulted in its rapidand massive colonization of all the leaf tissues including the vascular tissue, together with cytoplasmic collapse, distortion of chloroplasts, and disruption of host cell walls. However, penetration of C. cocodes was very limited in the older leaf tissues of pepper plants at the eight-leaf stage. Fungal hyphae grew only in the intramural spaces of the epidermal cell walls at this stage. Occlusion of amorphous material in xylem vessels, aggregation of fibrillar material in inter-cellular spaces, and deposition of protein bodies were found as resistance responses to C. cocodes.

  • PDF

주철근의 개수 및 단면비에 따른 폭발하중을 받는 철근콘크리트 기둥의 해석적 연구 (Parametric Study on Reinforced Concrete Columns under Blast Load)

  • 최호순;김민숙;이영학
    • 한국전산구조공학회논문집
    • /
    • 제25권3호
    • /
    • pp.219-226
    • /
    • 2012
  • 기둥은 건물에서 하중을 지지하는 중요한 구성요소이므로 기둥의 손상 또는 파괴는 건물의 연쇄붕괴의 원인이 된다. 특히 폭발하중에 의한 기둥의 거동평가는 연쇄붕괴 방지에 있어 중요한 요소이다. 본 논문에서는 축하중을 받고 있는 기둥이 폭발하중을 받을 때의 거동과 폭발 저항성능을 평가하였다. 이를 위해 동일단면적과 비슷한 철근비를 가지는 기둥에서 주 철근의 개수를 달리하여 각 변수에 따른 폭발하중에 대한 폭발 저항성능을 평가하였다. 또한, 동일한 성능을 지니는 기둥에서 단면비를 달리하여 기둥의 폭발 저항성능을 비교하였다. 해석결과, 폭발 직후 충격량에 대한 수직 변형률은 철근의 개수 및 단면비에 영향을 받지 않는 것으로 나타났다. 그러나 수평변형의 경우 폭발압력을 받는 면의 철근 개수가 증가함에 따라 기둥의 저항성능이 증가하는 것으로 나타났다. 또한, 기둥 단면의 단면 2차모멘트가 클수록 폭발하중에 대한 저항 성능 및 복원력이 더 큰 것을 확인하였다.