• Title/Summary/Keyword: prism

Search Result 831, Processing Time 0.029 seconds

High Brightness Prism Light-guide Plate for TFT-LCDs Using Optical Simulation and Novel Injection Mold Process (광학시뮬레이션과 새로운 사출성형법을 사용한 TFT-LCD용 고휘도 프리즘 도광판)

  • Han, Jeong-Min;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.2
    • /
    • pp.93-96
    • /
    • 2012
  • We have designed high performance prism light-guide plate (LGP) in 17 inch TFT-LCD. In test result to embody high brightness BLU in case of LGP of base and upper surface with 17 inch, thickness 8mm adding prism construct. Using optical simulation, we forecast the brightness and uniformity in LGP with prism structure. And we adopted novel injection mold method and Nickel stamper to make actual evolution sample. Novel injection mold process has steady heating time zone in heat cycle time of injection mold process. For this novel heat cycle control, we achieved above 90[%] height prism structure as our design. It is superior brightness improvement than previous that of printing form about some 20[%] and in this course to embody actual material it succeeded prism LGP production by 17 inch injection form process.

Subjective Visuoperception to Vertical Yoked Prisms (수직동향프리즘의 자각적 시감각에 관한 연구)

  • Kim, Jae-Do;Kim, Dae-Hyun;Lee, Ik-Han;Kim, Bong-Whan;Kim, Young-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.95-99
    • /
    • 2008
  • Purpose: Even refractive error is perfectly corrected by glasses power, the glasses wearer can feel imbalance and uncomfortable by prism effects. The purpose of this study was to investigate subjective imbalance to vertical yoked prism in visually normal subjects. Methods: Visually normal 37 subjects (aged 20 to 31 y) were fully corrected by soft contact lens and worn vertical yoked prism, base up and base down 1, 2, 4, 6, 8 prism diopter(pd) at random order. A rating scale questionnaire was administered to assess quantitatively subjective imbalance to the yoked prism. The near phoria tests were done using Howell-Kim phoria card at 40 cm distance. Results: For the subjective response of imbalance, base up yoked prism was higher than base down yoked prism (t-test: t=4.67, p=0.00) in over 2 prism diopters. The frequency of subjects who feel imbalance by base up vertical yoked prism is higher for near esophoric group than for exophoric group. Conclusions: To reduce subjective imbalance caused by glasses such as dizzy, it needs to make the minimum prism effect, and base down yoked prism is more effective than base up yoked prism in prism effects.

  • PDF

Optimization of PRISM Parameters and Digital Elevation Model Resolution for Estimating the Spatial Distribution of Precipitation in South Korea (남한 강수량 분포 추정을 위한 PRISM 매개변수 및 수치표고모형 최적화)

  • Park, Jong-Chul;Jung, Il-Won;Chang, Hee-Jun;Kim, Man-Kyu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.3
    • /
    • pp.36-51
    • /
    • 2012
  • The demand for a climatological dataset with a regular spaced grid is increasing in diverse fields such as ecological and hydrological modeling as well as regional climate impact studies. PRISM(Precipitation-Elevation Regressions on Independent Slopes Model) is a useful method to estimate high-altitude precipitation. However, it is not well discussed over the optimization of PRISM parameters and DEM(Digital Elevation Model) resolution in South Korea. This study developed the PRISM and then optimized parameters of the model and DEM resolution for producing a gridded annual average precipitation data of South Korea with 1km spatial resolution during the period 2000-2005. SCE-UA (Shuffled Complex Evolution-University of Arizona) method employed for the optimization. In addition, sensitivity analysis investigates the change in the model output with respect to the parameter and the DEM spatial resolution variations. The study result shows that maximum radius within which station search will be conducted is 67km. Minimum radius within which all stations are included is 31km. Minimum number of stations required for cell precipitation and elevation regression calculation is four. Optimizing DEM resolution is $1{\times}1km$. This study also shows that the PRISM output very sensitive to DEM spatial resolution variations. This study contributes to improving the accuracy of PRISM technique as it applies to South Korea.

The Visualization of the Flowfield around Square Prism Having Fences Using the PIV (PIV를 이용한 펜스를 가진 정방형주 주위의 유동장 가시화)

  • Ro, Ki-Deok;Kim, Kwang-Seok;Oh, Se-Kyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.94-99
    • /
    • 2008
  • The characteristics of the flowfield of a square prism having fences on the corner was investigated by the PIV. Strouhal numbers, velocity vectors and velocity profiles around the square prism were observed at various positions of the fences, and Reynolds number of $Re=0.6{\times}10^4{\sim}1.0{\times}10^4$. As the results in case of the prism having fences the Strouhal numbers were all smaller than in case of the prototype prism. In case of the prism having vertical fences on the front corners the concentrated intensity of the vorticity was the strongest and the size of separated shear layer was the largest. While in case of the prism having vertical fences on the rear corners the concentrated intensity of the vorticity was the weakest and the size of separated shear layer was the smallest. Also in this case, the flow separated in front corner was reattached around the rear corner and made circulation.

Continuous Viewing Angle Distribution Control of Liquid Crystal Displays Using Polarization-Dependent Prism Array Film Stacked on Directional Backlight Unit

  • Park, Min-Kyu;Park, Heewon;Joo, Kyung-Il;Jeong, Hee-Dong;Choi, Jun-Chan;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.799-806
    • /
    • 2016
  • We present a polarization-dependent prism array film for controlling the viewing angle distribution of liquid crystal (LC) display panels without loss of light efficiency. On a directional backlight unit, our polarization-dependent prism array film, made into a stacked bilayer with a well-aligned liquid crystalline reactive mesogen (RM) layer on the UV-imprinted prism structure, can continuously control the light refraction function of the prism array by electrically switching incident polarization states of a polarization-controlling layer prepared by a twisted nematic LC mode. The viewing angle control properties of the polarization-dependent prism array film are analyzed under different prism angle and refractive index conditions of the RM layer. A simple analytic model is also presented to describe the intermediate viewing angle distributions with continuously varying applied voltages and incident polarization states.

Experiments of flowfield of a square prism having a front vertical plate (정면에 수직 평판을 가진 정방형주의 유동장 특성실험)

  • Ro, Ki-Deok;Jo, Dong-Bae;Yoon, Young-Jun;Park, Seo-Jin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.900-908
    • /
    • 2014
  • The Characteristics of the flowfields of a square prism having a small vertical plate at the upstream side was investigated by measuring of fluid force on the square prism and by visualization of the flow fields using PIV. The experimental parameters were the width ratios(H/B=0.2~0.6) of vertical plates to the prism width and the gap ratios (G/B=0~3) between the prism and the vertical plate. The drag reduction rate of the square prism was increased with H/B in case of the same G/B, and was increased and then decreased with G/B in case of the same H/B. The lift reduction rate of the square prism was hardly not affected by the width and gaps ratios, the average value was about 48.1%. In case of a square prism having a small vertical plate, the stagnation regions were represented in the upstream and downstream sides of the square prism.

Estimation of Fine-Scale Daily Temperature with 30 m-Resolution Using PRISM (PRISM을 이용한 30 m 해상도의 상세 일별 기온 추정)

  • Ahn, Joong-Bae;Hur, Jina;Lim, A-Young
    • Atmosphere
    • /
    • v.24 no.1
    • /
    • pp.101-110
    • /
    • 2014
  • This study estimates and evaluates the daily January temperature from 2003 to 2012 with 30 m-resolution over South Korea, using a modified Parameter-elevation Regression on Independent Slopes Model (K-PRISM). Several factors in K-PRISM are also adjusted to 30 m grid spacing and daily time scales. The performance of K-PRISM is validated in terms of bias, root mean square error (RMSE), and correlation coefficient (Corr), and is then compared with that of inverse distance weighting (IDW) and hypsometric methods (HYPS). In estimating the temperature over Jeju island, K-PRISM has the lowest bias (-0.85) and RMSE (1.22), and the highest Corr (0.79) among the three methods. It captures the daily variation of observation, but tends to underestimate due to a high-discrepancy in mean altitudes between the observation stations and grid points of the 30 m topography. The temperature over South Korea derived from K-PRISM represents a detailed spatial pattern of the observed temperature, but generally tends to underestimate with a mean bias of -0.45. In bias terms, the estimation ability of K-PRISM differs between grid points, implying that care should be taken when dealing with poor skill area. The study results demonstrate that K-PRISM can reasonably estimate 30 m-resolution temperature over South Korea, and reflect topographically diverse signals with detailed structure features.

Characteristics of Fluid Force Reduction for Two Different Square Prisms in a Tandem Arrangement (직렬배열에 놓인 크기가 다른 정방형주의 유체력 저감특성)

  • Ro, Ki Deok;Kang, Chang Whan;Park, Kwon Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.7
    • /
    • pp.435-443
    • /
    • 2017
  • The Characteristics of the flowfields of a square prism having a small square prism were investigated by measuring of lift and drag on the square prism and visualizing the flowfield using PIV. The experimental parameters were the width ratios(H/B=0.2~0.6) of small square prisms to the prism width and the gap ratios (G/B=0~3) between the prism and the small square prism. The drag reduction rate of the square prism initially increased and then decreased with the G/B ratio for the same H/B ratio, and increased with the H/B ratio for the same G/B ratio. The maximum drag reduction rate of 98.0% was observed at H/B=0.6 and G/B=1.0. The lift reduction rate of the square prism was not affected by the width and gap ratios; the total average value was approximately 66.5%. In case of a square prism having a small square prism, the stagnation regions were represented in the upstream and downstream sides of the square prism.

FHD Flexible Endoscopy Design Using Wedge Prism (Wedge Prism을 이용한 FHD급 연성 내시경 광학계 설계)

  • Park, Sung-Woo;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.295-302
    • /
    • 2022
  • In this paper, a wedge prism application method was studied to design a full-high-definition (FHD)-class high-resolution flexible endoscope. In the case of the conventional flexible endoscope optical system, the F number is made large or a liquid lens is applied to obtain the same imaging performance in a wide depth of field. However, there is a problem in that the diameter of the optical system increases because an additional light guide and equipment are required. To solve this problem, two wedge prisms were applied to the flexible endoscope optical system to adjust the image distance for each object distance. First, two wedge prisms were symmetrically placed on the designed endoscopic optical system. An image distance satisfying the target imaging performance according to each objective distance was derived. Next, the wedge prism decenter value for controlling the image distance was derived. By combining these two data, a wedge prism decenter value that satisfied the target imaging performance at each object distance was applied in multi configurations. As a result of the optimal design applied with the wedge prism, a target imaging performance of more than 20% of the modulation transfer function for a resolution of 178 cycles/mm was satisfied in the entire depth of field of 100 mm-7 mm.

Silicon Prism-based NIR Spectrometer Utilizing MEMS Technology

  • Jung, Dong Geon;Son, Su Hee;Kwon, Sun Young;Lee, Jun Yeop;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.91-95
    • /
    • 2017
  • Recently, infrared (IR) spectrometers have been required in various fields such as environment, safety, mobile, automotive, and military. This IR dispersive sensor detection method of substances is widely used. In this study, we fabricated a silicon (Si) prism-based near infrared (NIR) spectrometer utilizing micro electro mechanical system (MEMS) technology. Si prism-based NIR spectrometer utilizing MEMS technology consists of upper, middle, and lower substrates. The upper substrate passes through the incident IR ray selectively. The middle substrate, acting as a prism, disperses and separates the incident IR beam. The lower substrate has an amorphous Si (a-Si)-based bolometer array to detect the IR spectrum. The fabricated Si prism-based NIR spectrometer utilizing MEMS technology has the advantage of a simple structure, easy fabrication steps, and a wide NIR region operating range.