• 제목/요약/키워드: primary vortex

검색결과 76건 처리시간 0.021초

전개확산제트화염의 시간 발달 거동 (Temporally developing behavior of an evolving jet diffusion flame)

  • 박정;신현동
    • 대한기계학회논문집B
    • /
    • 제21권4호
    • /
    • pp.486-493
    • /
    • 1997
  • Experimental investigations on the comparison of developments between transient jets and evolving jet diffusion flames have been made in initial injection period. To achieve this experiment, an ignition technique using a residual flame as the ignition source is devised. High speed Schlieren visualizations, and measurements including jet tip penetration velocities and jet widths of the primary vortex are employed to examine the developing processes for several flow conditions. It is seen that the developing behaviors in the presence of flame are greatly different from those in transient jet, and thus the flow characteristics in the transient part are also modified. The discernible differences are shown to consist of the delay of the rollup of the primary vortex, the faster spreading after the rollup due to exothermic expansion, and the survival of only a primary vortex. The growth of primary vortex in the transient jet is properly explained through an impulsively started laminar vortex prior to the interaction. It is also found that the jet tip penetration velocity varies with elapsed time and an increase in Res gives rise to a higher tip penetration velocity.

Characteristics of Vortex Structure and Its Shear Velocity in a Scour Hole

  • 김진홍
    • 한국농공학회지
    • /
    • 제34권E호
    • /
    • pp.45-59
    • /
    • 1992
  • At downstream part of the hydraulic structures such as spiliway or drainage gate, jet flow can occur by gate opening. If stream bed is not hard or bed protection is not sufficient, scour hole will be formed due to high shear stress of the jet flow. We call this primary scour. Once the scour hole is formed, a vortex occurs in it and this vortex causes additional scour. We call this secondary scour. The primary scour proceeds to downstream together with flow direction but the secondary one proceeds to upstream direction opposite to it. If the secondary one continues and reaches to the hydraulic structure, it can undermine the bottom of hydraulic structure and this will lead to failure of structure itself. Thus, it is necessary to know the physical features of the vortex structure in a scour hole, which is the main mechanism of the secondary scour. This study deals with the characteristics of the vortex structure and its shear stress which causes the secondary scour.

  • PDF

반와류 홀의 형상 변화가 막냉각 효율에 미치는 영향 (Effects of Geometry of Anti-Vortex Holes on Film-Cooling Effectiveness)

  • 김준희;김선민;김광용
    • 한국유체기계학회 논문집
    • /
    • 제17권2호
    • /
    • pp.12-23
    • /
    • 2014
  • A parametric study on anti-vortex holes for turbine blade cooling was investigated numerically. Three-dimensional Reynolds-averaged Navier-Stokes equations and shear stress transport turbulence model were used for analysis of anti-vortex film cooling. Validation of numerical results was carried out comparing with experimental data. The cooling performance of anti-vortex holes was assessed by two geometric variables, the ratio of diameters of holes and the lateral distances between the primary hole and anti-vortex hole at blowing ratios of 0.5 and 1.0. The results showed that the spatially-averaged film-cooling effectiveness increases as the ratio of the diameters increases and the distance between the primary hole and anti-vortex hole decreases.

건물협곡에서의 2차 역회전 소용돌이 형성에 관한 연구 (A Study on Development of the Secondary Reverse Vortex in Building Canyon)

  • 손민우;김도용
    • 한국환경기술학회지
    • /
    • 제19권6호
    • /
    • pp.528-535
    • /
    • 2018
  • 본 연구에서는 전산유체역학(CFD) 모델을 이용하여, 건물 외관비에 따른 건물협곡에서의 소용돌이 현상을 재현하고 정량적인 해석을 시도하였다. 이를 위하여 건물협곡의 폭(W)을 기준으로 건물의 길이(L) 및 높이(H) 증가에 따른 민감도 실험을 수행하였으며, 건물협곡에서의 바람 벡터장과 2차 역회전 소용돌이의 형성 등을 분석하였다. 수평소용돌이의 경우에는 건물의 길이 증가에 따라 성장하다가 L/W=2.5부터 건물협곡의 중앙부에서 벡터의 크기 약화 및 방향 변화 등의 조짐이 보이기 시작하였고, L/W=3.0 이상에서 흐름이 분리되어 1차 소용돌이는 약화되고 건물협곡의 안쪽에서 2차 역회전 소용돌이가 형성되었다. 연직소용돌이의 경우에는 건물의 높이 증가에 따라 성장하다가 H/W=2.5부터 건물협곡의 하부에서 벡터의 방향전환 현상이 나타나기 시작하였고, H/W=3.5 이상의 조건에서 1차 소용돌이는 약화되고 2차 역회전 소용돌이가 형성되었다.

Numerical Analysis of Unsteady Flow around a Transversely Oscillating Circular Cylinder

  • Moon, Ji-Soo;Kim, Jae-Soo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권1호
    • /
    • pp.27-33
    • /
    • 2012
  • The relationship between the excitation frequency and the vortex shedding frequency is analyzed during the oscillation of the circular cylinder. Two-dimension unsteady Navier-Stoke's equation is calculated by using the Optimized High Order Compact (OHOC) scheme. The flow condition is Mach number 0.3 and Reynold's number 1000. From the results acquired by calculation, it can be inferred that, when the excitation frequency is near the vortex shedding frequency at the fixed cylinder wake, the oscillation frequency of lift and drag coefficients appears to lock-on. The lock-on refers to a phenomenon in which the aerodynamic coefficient appears as one primary oscillation frequency through excitation and its amplitude is amplified. In the non-lock-on zone, the excitation frequency is not in the lock-on mode anymore and beat is formed in which two or more primary oscillation frequencies of the aerodynamic coefficient are mixed together.

반와류 홀의 각도가 평판의 막냉각 효율에 미치는 영향 연구 (Effect of Anti-Vortex Hole Angle on the Flat Plate Film Cooling Effectiveness)

  • 박순상;박정신;이상훈;문영기;곽재수
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.5-10
    • /
    • 2014
  • In this paper, the experimental study was carried to investigate the effect of angle of the anti-vortex holes on the film cooling effectiveness on a flat plate. The pressure sensitive paint technique was applied to measure the film cooling effectiveness. Two anti-vortex hole angles of $0^{\circ}$ and $15^{\circ}$ with respect to the primary hole were considered, and the simple cylindrical hole case was also tested. The blowing ratio based on the cylindrical hole was 0.5 and the same flow rate was kept for all anti-vortex hole cases. Results showed that the film cooling effectiveness for the anti-vortex hole cases were much higher than that of the cylindrical case. Among the anti-vortex hole cases, $15^{\circ}$ angle anti-vortex hole case showed higher film cooling effectiveness than that by the $0^{\circ}$ angle anti-vortex hole case.

Evolution of Tip Vortices Generated by Two Bladed Rotor in Hover at Early Wake Ages

  • Park, Byung-Ho;Han, Yong-Oun
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제10권2호
    • /
    • pp.106-116
    • /
    • 2009
  • In order to investigate change of vortex structures and its evolving proceses, two dimensional LDV system was used for measurement of velocity vectors of tip vortex, and PIV system was also used for visualizations of tip vortex array for two bladed rotor, respectively. Experiments provided vortex locations, tangential and axial velocity components of tip vortex at six wake ages of 9.5, 10.5, 60.5, 99.5, 129.5, 169.5 and corresponded six wake ages shifted with 180 degrees per each. It was resulted that tip vortices generated by the first blade satisfy Landgrebe's model for their vortex locations even after they were accelerated by the second blade in downstream. Tangential velocity components of tip vortices follow Vatistas' n=2 model on both inside and outside regions of rotor slipstream without loss of vortex circulation. Axial velocity profiles revealed that there were small but significant perturbations just outside the primary vortex core which implies the second blade affects the wake substantially. It was also found that tip paths of each blade were not willing to be coincided intrinsically.

평판 위에 부착된 실린더 주위의 말굽와류 시스템에 관한 실험적 연구 (Experimental Study on the Horseshoe Vortex Systems Around Surface-Mounted Obstacles)

  • 양준모;유정열
    • 대한기계학회논문집
    • /
    • 제16권10호
    • /
    • pp.1979-1989
    • /
    • 1992
  • 본 연구에서는 말굽와류에 대한 전반적인 사항을 고찰하는 한편, 실린더의 기 하학적 형상이 말굽와류에 미치는 영향을 정성적으로 고찰하는 데 있다. 그러므로 본 실험에서는 먼저 경계층이 형성되어 있는 평판에 원형 실린더를 설치하여, 말굽와 류에 의한 3차원 유동현상을 고찰하고, 또한 동일한 평판에 쐐기형상의 실린더를 설치 하여, 그 주위에서 발생하는 3차원 유동현상과 원형 실린더 주위에서 일어나는 3차원 유동현상과의 정성적인 비교를 통하여, 말굽와류에 의한 3차원 유동손실을 줄일 수 있 는 가능성을 제시하고자 한다.

Inlet Cone Vortex에 의한 500 MW급 발전용 보일러 홴-덕트 시스템의 과대진동 (Excessive Vibration of the Fan-duct Systems in 500 MW Power Plant Boilers Due to Inlet Cone Vortex)

  • 김철홍;주영호;변형현
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.116-121
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure Pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

수평 원통 관에서 선회를 동반한 유동각에 대한 실험적 연구 (An Experimental Study on Flow Angle with Swirl in a Horizontal Circular Tube)

  • 장태현
    • 한국기계가공학회지
    • /
    • 제2권4호
    • /
    • pp.82-87
    • /
    • 2003
  • Flow angle with Swirl in a horizontal circular tube and a cylindrical annuli were experimentally studied for its visualization. This present investigation deals with flow angle, flow visualization studies and vortex core by using oil smoke and a hot wire anemometer for Re = 40,000 and 50000 at X/D = 41, 59 and 71 in a horizontal circular tube. In the swirl air flow, a vortex core was formed at high swirl intensity along the test tube. The flow angle and the vortex core depended on the swirl intensity along the test tube. The results of flow angles with swirl measured by flow visualization and hot wire reasonably agree with those of Sparrow One of the primary objectives of this research was to measure the flow angle with swirl in a cylindrical annuli along the test tube for different Reynolds numbers. The Reynolds number for these measurements ranged from 60,000 to 100,000 with L/D = a to 4.

  • PDF