Journal of the Society of Naval Architects of Korea
/
v.57
no.5
/
pp.271-277
/
2020
Recoverability and vulnerability of navy ships under underwater explosion are critical verification factors in the acquisition phase of navy ships. This paper aims to establish numerical analysis techniques for the underwater explosion of navy ships. Doubly Asymptotic Approach (DAA) Equation of Motion (EOM) of primary shock wave and secondary bubble pulse proposed by Geers-Hunter was introduced. Assuming a non-compressive fluid, reference solution of the DAA EOM of Geers-Hunter using Runge-Kutta method was derived for the secondary bubble pulse phase with an assumed charge conditions. Convergence analyses to determine fluid element size were performed, suggesting that the minimum fluid element size for underwater explosion analysis was 0.1 m. The spherical and cylindrical fluid domains were found to be appropriate for the underwater explosion analyses from the fluid domain shape study. Because the element size of 0.1 m was too small to be applied to the actual navy ships, a very slender beam with the square solid section was selected for the study of fluid domain existence effect. The two underwater explosion models with/without fluid domain provided very similar results in terms of the displacement and stress processes.
To understand effects of cooling rates of coating layer on microstructures and corrosion behaviors of hot-dip alloy coated steel sheets (Zn-5%Al-2%Mg) in a neutral aqueous condition with chloride ion, a range of experimental and analytical methods were used in this study. Results showed that a faster cooling rate during solidification decreased the fraction of primary Zn, and increased the fraction of Zn-Al phase. In addition, interlamellar spacing became refined under a faster cooling rate. These modifications of the coating structure had higher open circuit potentials (OCP) with smaller anodic and cathodic current densities in the electrochemical potentiodynamic polarization. Surface analyses after a salt spray test showed that the increase in the Zn-Al phase in the coating formed under a faster cooling rate might have contributed to the formation of simonkolleite (Zn5(OH)8Cl2·H2O) and hydrotalcite (ZnAl2(OH)6Cl2·H2O) with a protective nature on the corroded outer surface, thus delaying the formation of red rust.
This paper provides an assessment of fluid transport and mixing processes inside the primary circuit of the test facility ROCOM through the numerical simulation of Test 2.1 with the system code ATHLET. The experiment represents an asymmetric injection of cold and non-borated water into the reactor coolant system (RCS) of a pressurized water reactor (PWR) to restore core cooling, an emergency procedure which may subsequently trigger a core re-criticality. The injection takes place at low velocity under single-phase subcooled conditions and presents a major challenge for the simulation in lumped parameter codes, due to multidimensional effects in horizontal piping and vessel arising from density gradients and gravity forces. Aiming at further validating ATHLET 3-D capabilities against horizontal geometries, the experiment conditions are applied to a ROCOM model, which includes a newly developed horizontal pipe object to enhance code prediction inside coolant loops. The obtained results show code strong simulation capabilities to represent multidimensional flows. Enhanced prediction is observed at the vessel inlet compared to traditional 1-D approach, whereas mixing overprediction from the descending denser plume is observed at the upper-half downcomer region, which leads to eventual deviations at the core inlet.
The Transactions of the Korean Institute of Power Electronics
/
v.27
no.5
/
pp.384-390
/
2022
In this study, a single-stage, four-phase, interleaved, totem-pole AC-DC converter is proposed for a super-fast charger station that requires high power, a wide voltage range, and bidirectional operation capabilities and adopts various types of electric transport vehicles. The proposed topology is based on current-fed push-pull dual active bridge converter combined with the totem-pole operation. Owing to the four-phase interleaving effect, the bridge on the grid side can switch at 0.25, 0.5, and 0.75 to achieve a ripple-free grid current. The input filter can be removed theoretically. Switching methods for the duty of the secondary-side duty cycle are proposed, and they correspond to the primary duty cycle for reducing the circulating power and handling the total harmonic distortion. Therefore, the converter can operate under a wide voltage range. Experimental results from a 7.5 kW prototype are used to validate the proposed concept.
Jo, Gwang Hee;Noh, Jae Hee;Lim, Deok Won;Son, Seok Bo;Hwang, Dong-Hwan;Lee, Sang Jeong
Journal of Positioning, Navigation, and Timing
/
v.10
no.4
/
pp.307-313
/
2021
Modernized GNSS signal structures tend to use tiered codes, and all GNSSs use binary codes as secondary codes. However, recently, signals using polyphase codes such as Zadoff-Chu sequence have been proposed, and are expected to be utilized in GNSS. For example, there is Tiered Differential Polyphase Code (TDPC) using polyphase code as secondary code. In TDPC, the phase of secondary code changes every one period of the primary code and a time-variant error is added to the carrier tracking error, so carrier tracking ambiguity exists until the secondary code phase is found. Since the carrier tracking ambiguity cannot be solved using the general GNSS receiver architecture, a new receiver architecture is required. Therefore, in this paper, we describe the carrier tracking ambiguity and its cause in signal tracking, and propose a receiver structure that can solve it. In order to prove the proposed receiver structure, we provide three signal tracking results. The first is the differential decoding result (secondary code sync) using the general GNSS receiver structure and the proposed receiver structure. The second is the IQ diagram before and after multiplying the secondary code demodulation when carrier tracking ambiguity is solved using the proposed receiver structure. The third is the carrier tracking result of the legacy GPS (L1 C/A) signal and the signal using TDPC.
Rachmawati, Titi Sari Nurul;Widjaja, Daniel Darma;Kim, Sunkuk
Journal of the Korea Institute of Building Construction
/
v.23
no.4
/
pp.497-508
/
2023
Manual estimation of rebar quantities by contractors often yields discrepancies between projected and actual amounts used in the construction phase, leading to cost inaccuracies and potential logistical challenges. To address these issues, there is a clear need for a method that allows precise estimation of rebar quantities during the design phase. Such a method would enhance contractor competitiveness during project bids, promote accurate cost calculations, and avert superfluous rebar purchases on-site. Given that columns are the primary structural components in reinforced concrete(RC) buildings and necessitate considerable amounts of rebar, this study focuses on creating an automated algorithm for estimating column rebar quantities. An analysis of the accurate quantities obtained via the study and those derived from manual estimation reveals a discrepancy of 0.346 tons or 2.056%. This comparison affirms the proposed algorithm's efficacy in eliminating errors from overestimation or underestimation of rebar quantities. The practical implications of this study are significant for construction companies as it fosters efficient and precise estimation of rebar quantities, ensuring compliance with related specifications and governing regulations.
In the present study, an analytical method was proposed for detecting trifluralin in aquatic products at trace concentrations. The method employed QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) and gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) as the sample preparation and measurement, respectively. The effect of the aqueous phase volume used in the QuEChERS was demonstrated, and the ratio of 10:10 (mL) between water and acetonitrile phase was used for 5 g of sample. Besides, dSPE using C18 and primary-secondary amine (PSA) was applied to remove the potential interferences from the food matrices, indicating no remarkable analyte loss. The linear range was built up from 0.50 ㎍ L-1 to 3.0 ㎍ L-1 (R2 = 0.9993). Other criteria, i.e., repeatability (RSDr = 0.86-1.96 %), reproducibility (RSDR = 1.09-2.01 %), and recovery (over 90 %), were in accordance with Appendix F of AOAC (2016) for method performance. Although no trifluralin was detected for the commercial samples (fish, shrimp, and breaded shrimp), the spiked samples performed favorable recoveries and precision.
Journal of the korean academy of Pediatric Dentistry
/
v.36
no.4
/
pp.556-562
/
2009
Ectopic eruption of the maxillary first permanent molar means that the molar erupts out of the normal position and is arrested in its eruption by the second primary molar. This local eruption disturbance results in a premature atypical resorption on the distal part of the second primary molar. In most irreversible cases, the second primary molar is lost prematurely, either by spontaneous exfoliation or by extraction, In cases of doubt as to whether the eruption is of the irreversible type or not, careful radiographic observation period for a few months would be valuable in evaluating the possibilities of the tooth's freeing itself. The purpose of this study was to determine the characteristics and occurrence of the ectopic eruption of the maxillary first permanent molar. A descriptive, observational, retrospective study was done using the radiographs of 25 conseutive patients, who were in the first phase of mixed dentition. A method was designed to evaluate the amount of pathologic resorption of the second maxillary primary molar and the mesial angulation of the first permanent molar. The study showed that the most important etiologic factor was the eruption path or mesial angulation of the first permanent molars relative the chosen reference lines.
Intracellular calcium concentration ($[Ca^{2+}]_i$) may play a crucial role in a variety of neuronal functions. Here we report that in primary culture of mouse cerebellar granule cells nicotinic acetylcholine receptors (nAChRs) are expressed in a specific developmental stage and involved in the regulation of intracellular calcium homeostasis. Nicotine-mediated calcium responses were measured using $^{45}Ca^{2+}$ or fluorometrically using the calcium-sensitive fluorescent dye fura-2. Maximal uptake of $^{45}Ca^{2+}$ evoked by nicotine in mouse cerebellar granule cells were revealed $8{\sim}12$ days in culture. In contrast, nicotine did not alter the basal $^{45}Ca^{2+}$ uptake in cultured glial cells. In cerebellar granule cells nicotine-evoked $^{45}Ca^{2+}$ uptake was largely blocked by the NMDA receptor antagonists. Glutamate pyruvate transaminase (GPT). which removes endogenous glutamate, also prevented nicotine effects, implying the indirect involvement of glutamate in nicotine-mediated calcium responses. Fluorometric studies using fura-2 showed two phases of nicotine-evoked $[Ca^{2+}]_i$ rises: the initial rising phase and the later plateau phase. Interestingly, the NMDA receptor antagonists and GPT appeared to inhibit only the later plateau phase of nicotine-evoked $[Ca^{2+}]_i$ rises. The present results imply that nicotine mediated $^{45}Ca^{2+}$ uptake and $[Ca^{2+}]_i$ rises are attributed to the calcium fluxes through both nAchRs and NMDA receptors in a time-dependent manner. Consequently, nAChRs may play an important role in neuronal development by being expressed in a specific developmental stage and regulating the intracellular calcium homeostasis.
Park, In-Shik;Jung, Chan-Young;Jang, Min-Ki;Kang, Mi-Suk;Lee, Seung-Woo;Kim, Eun-Jung;Lee, Seung-Deok;Kim, Kap-Sung
Journal of Acupuncture Research
/
v.25
no.2
/
pp.227-242
/
2008
Objectives : To compare the efficacy of local acupoint with distal acupuncture at relieving pain and improving function in knee osteoarthritis. Designs : A randomized, single-blinded, crossover clinical trial. Settings : One outpatient clinic(department of acupuncture & moxibustion) located in academic teaching hospital, South Korea. Patients : 17 patients with osteoarthritis of the knee(mean age 62.76[$SD{\pm}4.37$] years). Interventions : The trial had 4 stages : baseline(2weeks), phase I and II(each 2weeks), washout period(2weeks). Patients were randomly assigned to either group A or group B. Group A received acupuncture at local acupoints during phase I, then acupuncture at distal acupoints in phase II. Group B received the treatments in reverse order. In each phase, the patients were treated with acupuncture for 6 times. Measurements : The primary outcome was subjective pain as measured by a 100mm visual analogue scale(VAS) ranging from 0(no pain) to 10(worst pain ever). Secondary outcomes were changes in the Western Ontario and McMaster Universities Osteoarthritis Index(WOMAC) total and pain scores. Measurements were obtained at baseline, 1st day of phase I and II, and 2 days after last treatment of phase I and II. Results : The 17 participants in 2 groups were well matched for age, sex, target knees, baseline VAS score, WOMAC pain score and WOMAC score. Participants in local acupoint group experienced greater improvement than distal acupoint group at 2 days after last treatment in WOMAC total score(mean difference, -10.65[95% CI, -20.56 to -0.74] ; P=0.036) but not in VAS(mean difference, -12.41[95% CI, -29.56 to 4.73] P=0.15) and WOMAC pain score(mean difference, -1.82[95% CI, -3.98 to 0.33] ; P=0.094). Conclusions : Local acupoints are more effective than distal acupoints at relieving pain and improving function in knee osteoarthritis.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.