• Title/Summary/Keyword: primary element

Search Result 760, Processing Time 0.029 seconds

Design Simulation of Epoxy Mold Type PT using Finite Element Method (유한 요소법을 이용한 에폭시 몰드형 PT의 설계 시뮬레이션)

  • Park, Geon-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.119-122
    • /
    • 2005
  • In this study, the design simulation for optimal wire batch around service line was made to improve the dielectric strength at the primary winding using Finite Element Method. The automatic convergence algorithm for finding of limit object value using loop circulation method was developed to make the optimal design simulator. The modulation method was suggested to make division time faster which was very important for full simulation efficiency. As a result, the simulation time was reduced and the optimal wire batch design was obtained.

  • PDF

3D Finite Element Analysis of Contactless Power Supply with Linear Servo Motor (선형 서보 전동기가 결합된 비접촉 전력 전달 장치의 3차원 유한요소 해석)

  • Woo, Kyung-Il;Park, Han-Seok;Park, Hyong-Bum;Jung, Hong-Seob;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.819-820
    • /
    • 2006
  • This paper presents the 3D finite element analysis of contactless power supply with linear servo motor. The voltage source is used to analyze the characteristics of contactless power supply. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the previous finite element analysis are used. Also the driving circuit to supply the power to the linear servo motor is designed. The characteristics analysis of contactless power supply considering the linear servo motor is done.

  • PDF

An Implicit Stress Integration for the Constitutive Relationship of Clays (점토의 구성관계에 대한 내재적인 응력적분)

  • 오세붕
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.92-98
    • /
    • 1998
  • Nonlinear finite element analyses of one dimensional consolidation problem were performed using an anisotropic hardening constitutive model. For the analyses, the anisotropic hardening elasto-plastic constitutive model based on the generalized isotropic hardening(GIH) rule was implemented into a nonlinear finite element analysis program, PLASTIC. In order to preserve the accuracy of the finite element solution for nonlinear problems, an implicit stress integration algorithm was employed. A consistent tangent moduli could also ensure the quadratic convergence of Newton's method. As a result, the nonlinear solution was accurately calculated and was converged to be asymptotically quadratic. In a consolidation problem, the relationship between load and settlement and between settlement and time vertical was analyzed comparing with results using the Cam-clay type model and the final consolidation settlement and the duration of primary consolidation could be evaluated rigorously using the GIH constitutive model.

  • PDF

Characteristic analysis of contact-less energy transmission system using 3D finite element method (3차원 유한요소법을 이용한 비접촉 전력 전달 장치 특성 해석)

  • Woo Kyung il;Park Han Seok;Cho Yun Hyun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.803-805
    • /
    • 2004
  • This paper proposes the calculation method of magnetic coupling coefficient of the contact-less energy transmission system by 3D finite element method with a variation of the secondary core positions. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the finite element analysis results. From these values, the magnetic coupling coefficients are obtained. The secondary voltages and currents at the secondary core positions are calculated by using the resonant circuit and compared.

  • PDF

Electromagnetic Analysis of Angular Position Detector for SMART Control Element Drive Mechanism (SMART용 제어봉구동장치에 장착되는 위치측정기의 전자장해석)

  • Huh, Hyung;Kim, Kern-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.309-311
    • /
    • 2000
  • An advanced angular position detector (APD) for the SMART CEDM (control element drive mechanism) was designed. The APD is required to be small size with high resolution for angular displacement of rotary step motor. Unfortunately the proximity sensors can not be adopted to SMART CEDM because the motor shaft is located in the pressure boundary cylinder filled with the primary coolant under high temperature and pressure. This paper describes the electromagnetic finite element analysis for the design of advanced angular position detector for the SMART CEDM. The electromagnetic properties obtained will be used as Input for the optimization analysis of the APD.

  • PDF

The characteristic analysis of contact-less Power supply by 3D finite element method

  • Park, Han-Seok;Cho, Yun-Hyun;Jung, Hong-Sub;Woo, Kyung-il;Kim, Kyung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.145-151
    • /
    • 2004
  • This paper proposes the calculation method of magnetic coupling coefficient of contact-less power supply by the 3D finite element method with a variation of the secondary core position. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the finite element analysis results. The magnetic coupling coefficients are obtained also. The power factors are obtained by simulation for the magnetic coupling coefficients and compared.

Finite Element Analysis for the Contact Behavior in Double-Type Mechanical Face Seals Used for Small Hydro Power Turbine (소수력 터빈용 복수 기계평면시일의 접촉거동에 관한 유한요소해석)

  • Kim, Chung-Kyun;Kang, Hyun-Joon
    • Tribology and Lubricants
    • /
    • v.21 no.5
    • /
    • pp.201-208
    • /
    • 2005
  • This paper presents the FEM analysis on the contact behavior characteristics of mechanical face seals in a small hydro-power turbine. Especially, the axial displacement and contact normal stress between a seal ring and a seal seat of a primary sealing unit have been analyzed as functions of rotating speed of a hydro-turbine, sealing gap, water and cooling fluid temperature. Those are strongly related to a leakage of water and wear between a seal ring and a seal seat. The FEM computed results present that the rotating speed of a hydro-turbine may be kept less than 800 rpm, and the sealing gap in a primary sealing unit is restricted $0.5\~5$. The coolant temperature in which is most influential parameter to the contact behaviors of a sealing unit may be kept less than $15^{\circ}C$ for a safe operation of a sealing unit without a leakage and wear.

Analysis of Heat Generation Induced by Electron Impact in X-Ray Tube Using FEM and Monte Carlo Method (유한요소법과 몬테카를로법을 이용한 X선 튜브에서 전자빔 충격에 의한 열 발생 해석)

  • Kim, Heungbae;Yoo, Tae Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.4
    • /
    • pp.387-394
    • /
    • 2015
  • We analyze heat generation as well as temperature distribution induced by accelerated electron impact on a target in a closed x-ray tube. For the sake of accuracy, we use Monte carlo analysis. This method gives accurate energy deposit in a medium with additional information such as secondary and backscattered electron as well as their paths. A Tungsten coated layer is divided by small rectangular cell which accumulate energy loss of primary electron beam. The cells and their accumulated energy datum are used for the input of finite element analysis. The Maximum temperature rising and temperature distribution were analyzed by transient heat analysis. Some temperature parameters such as target size and coating thickness were varied to investigate temperature sensitivity. Temperatures were compared each other to find primary variable that affect temperature rising on the x-ray target. The results will be helpful in development highresolution x-ray tube and related industries.

A Study on The Space Depth For Hospital Architecture Planning Focused on System (체계 중심 병원건축계획을 위한 공간 깊이에 관한 연구)

  • Kim, Eun-Seok;Yang, Nae-Won
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.6
    • /
    • pp.221-228
    • /
    • 2015
  • This study aims to define concepts on Hospital Design Focused on System to respond to the development and change by comparing general design methods of the General hospital architecture in Korea and analyze elements suitable to concepts on Hospital Design Focused on System in the General hospital architecture through examining the transformation of General hospitals in Korea. Essential architectural elements composing the Hospital Design Focused on System are as follows. First of all, the elements which can react to development of hospital architecture are HOSPITAL STREET and site situation. Secondly, core, equipment shaft, column, MAIN STREET and air handling unit room are elements of great importance as the location of these elements determines the dimensions and scale of the space which hospital functions are assigned to. Third, the area in regard to the rate of change is formed by MAIN STREET, which is the primary element, and envelope. The depth between MAIN STREET and envelope is defined as space depth. The flexible area is determined depending on this space depth and thus how to set up this flexible area determines the degree of readiness in responding to the change.

Root Cause Analysis and Structural Integrity Evaluation for a Crack in a Reactor Vessel Upper Head Penetration Nozzle (원자로 상부헤드 관통노즐 균열에 대한 원인분석 및 건전성 평가)

  • Lee, Kyoung-Soo;Lee, Sung-Ho;Lee, Jeong-Seog;Lee, Jae-Gon;Lee, Seung-Gun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.56-61
    • /
    • 2013
  • This paper presents the results of integrity assessment for the cracks happened in reactor vessel upper head penetration nozzles. The crack morphology for a boat sample from crack area was analyzed through microscope. The stress condition including weld residual stress around crack was analyzed using finite element analysis. From the results of crack morphology and stress condition, the crack was concluded as primary water stress corrosion cracking. The integrity of the cracked nozzle was assessed by the methodology provided in ASME Section XI. According to the assessment results, the remaining life of the cracked nozzle was 1.43 yrs. and the plant decided to repair it.