• Title/Summary/Keyword: prestress load

Search Result 128, Processing Time 0.024 seconds

Seismic Resistance of Masonry Walls Strengthened with Unbonded Prestressed Steel Bars and Glass Fiber Grids (강봉 및 유리섬유로 비부착 보강된 조적벽체의 내진 저항성 평가)

  • Baik, Ji-Sung;Yang, Keun-Hyeok;Hwang, Seung-Hyeon;Choi, Yong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.17-26
    • /
    • 2020
  • This study examined the structural effectiveness of the unbonded technique originally developed for seismic strengthening of unreinforced masonry walls on the basis of the prestressed steel bars and glass fiber (GF) grids. The masonry walls were strengthened by using individual steel bars or GF grids and their combination. Test results showed that the proposed technique was favorable in enhancing the strength, stiffness, and ductility of the masonry walls. When compared with the lateral load capacity, stiffness at the ascending branch of the lateral load-displacement curve, and energy dissipation capacity of the unstrengthened control wall, the increasing ratios were 110%, 120%, and 360%, respectively, for the walls strengthened with the individual GF grids, 140%, 130%, and 510%, respectively, for the walls strengthened with the individual steel bars, and 160%, 130%, and 840%, respectively, for the walls strengthened with the combination of steel bars and GF grids. The measured lateral load capacities of masonry walls strengthened with the developed technique were in relatively good agreement with the predictions by the equations proposed by Yang et al. Overall, the developed technique is quite promising in enhancing the seismic performance of unreinforced masonry walls.

Analysis and Design of Support Strut in Innovative Prestressed Scaffolding(IPS) System (혁신적 프리스트레스트 가시설 구조시스템(IPS)에 적용되는 중간 버팀보의 해석 및 설계)

  • Kim, Sung Bo;Han, Man Yop;Kim, Moon Young;Kim, Nak Kyung;Han, Jin Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.627-636
    • /
    • 2005
  • The analysis and design procedure of intermediate support strut for the innovative prestressed scaffolding (IPS) system was presented in this paper. The stability check of intermediate support strut is required as the behavior of the strut system is similar to that of the built-up column. The computer analysis model of the support strut was constructed for in-plane and out-of-plane buckling analysis, and the design of the support strut was performed. Using the eigenvalue for the buckling load and the member forces of support strut under design earth pressure, the effective buckling length was estimated. The allowable axial and bending stresses were calculated considering the effective buckling length. The combined stresses due to these axial forces and bending moment were estimated to be satisfied the safety condition of the intermediate support strut.

Numerical Analysis of Curling Behavior of Prestressed Approach Slab Subjected to Environmental Loads (환경하중에 의한 교량 프리스트레스 접속슬래프의 컬링 거동 수치 해석적 분석)

  • Park, Hee-Beom;Eum, In-Sub;Kim, Seong-Min;Rhee, Suk-Keun
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.7-14
    • /
    • 2011
  • The numerical analyses were performed to investigate the curling behavior of the post-tensioned prestressed concrete approach slab (PTAS) under environmental loads. A technique to include properly the boundary conditions of one end of PTAS that was connected to the bridge abutment using hinges was proposed for the numerical model. The applicability of a simplified model not having hunches was also investigated. By using the developed models, the curling behavior of PTAS was analyzed when the foundation settlement occurred. The analysis results showed that the maximum tensile stress obtained from the simplified model involving a simplified hinge connection was very closed to that obtained from a rigorous model. When the slab curled up, the maximum tensile stress occurred in the model including no foundation settlement, but when the slab curled down, the maximum stress occurred in the model including partial settlement of the foundation. Therefore, the design of PTAS should be performed considering those maximum tensile stresses.

Prediction of Cracking and Ultimate Loads of Prestressed Concrete Anchorage Zones in Box-Girder Bridges (프리스트레스트 콘크리트 박스거더 교량 부재의 정착부 균열하중 및 극한하중의 예측)

  • 임동환;오병환
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.5
    • /
    • pp.171-182
    • /
    • 1994
  • Recently, several prestressed concrete box girder bridges have experienced severe cracking along the tendon path when prestress force has been transferred to the anchorage zone. The purpose of the present study is therefore to explore characteristics of the local stress distribution, to study the effects of section geometry of anchorage zones, i.e., tendon inclination, tendon eccentricity and concrett. cover thickness anti to develop recornrncnd;itions for specific design criteria for post~tensioned a:lchorage zones. 7'0 accomplish these objectives, a cc~mprehen sive nonlinar finite element study has been conducted. From this study, realistic forrnulas for crackinq and ultimate load capacities are proposed. 'These equations reasonably well predict the crackinq and ultimate loads of prestressed concrete anchorage zones.

Experimental Evaluation for Ultimate Flexural Behaviors of PSC beams with A Corroded Tendon (PS강연선이 부식된 PSC보의 극한휨거동 평가실험)

  • Youn, Seok-Goo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.843-854
    • /
    • 2013
  • This paper presents experimental research work for the evaluation of ultimate flexural behaviors of prestressed concrete beams with a corroded tendon. In order to evaluate the effects of loss of prestress or loss of tendon area on the ultimate flexural strength of prestressed concrete beams, static load tests are conducted using five prestressed concrete beams. After exposing prestressing tendons in two test beams using 25mm drill bit, the exposed tendons were corroded using an accelerating corrosion equipment to simulate loss of tendon area. During the tests, steel strains, concrete strains and displacements at the center of test beams were measured, and acoustic emission measurements were conducted to detect wire fractures. Based on the test results, evaluation method for predicting flexural strength of prestressed concrete beams with corroded tendons is investigated. In addition, evaluation methods for predicting the existence of corroded tendons in post-tensioned prestressed concrete beams at service loads are discussed.

Structural Capacity of Poles Using Crack Self-healing Concrete (균열자기치유용 콘크리트를 사용한 전주의 구조 성능)

  • Yoo, Sung-Won;Kim, Sang-Jun;Park, Hong-Gi
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.222-227
    • /
    • 2018
  • Recently, due to the deterioration and various natural disasters caused by the passage of concrete pole for 20~30 years or more, damage and destruction of the poles have increased the demand for maintenance. In this paper, 10 flexural strength test specimens were fabricated by using crack self - healing concrete of Fly ash, GGBS, CA, etc. The compressive strength of the concrete with slag was found to be excellent, but the concrete with fly ash was slightly below the reference strength. In addition, the crack loadings of the specimens satisfied the criteria of KS F 4304. In the case of the load-deflection and strain relations, the behavior of the fly ash specimens was similar, but in the specimens containing the blast furnace slag, The results showed that a large amount of strain occurred.

Fatigue Capacity of Concrete Beams Prestressed with Partially Bonded CFRP Tendons (CFRP 긴장재로 긴장된 부분비부착 콘크리트 보의 피로 성능)

  • Jeong, Sang-Mo;Lee, Cha-Don;Park, Sang-Yeol;Jeong, Yo-Sok;Park, Dong-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.333-336
    • /
    • 2008
  • CFRP tendons have been attempted in concrete structures as a substitute for steel tendons considering their many advantages such as the corrosion-resistance, light weight etc. However, the elastic behavior up to failure is likely to result in ductility problems. To overcome such problems, prestress concrete beams with partially bonded tendons have been developed and suggested. In this new system, the un-bonded part near the mid-span contributes to the improvement of ductility. And the bonded parts at both ends play a role as a safe anchorage. According to the previous research on the static behavior, the suggested method has demonstrated enough ductility and strength. However it is essential to verify the long-term safety for repetitive fatigue loads under service states. For this purpose, flexural fatigue loading tests were carried out in this research. This paper includes an experimental investigation on the static load-carrying capacities of the beams with or without fatigue tests. The results showed that the beams prestressed with partially bonded CFRP tendons possessed good fatigue capacity under the constant cyclic loads.

  • PDF

Experimental Study of Structural Behavior of Two-Way Beam String Structures (양방향 하중 저항 언더 텐션 시스템의 구조 성능에 대한 실험 연구)

  • Seo, Minhee;Lee, Seunghye;Baek, Kiyoul;Jeong, Jinwoo;Kim, Sun-Myung;Lee, Jaehong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.93-103
    • /
    • 2018
  • This study showed that experimental study of inelastic nonlinear behavior of two-way beam string structures. General large span structures consisting of beam members have large moment and long cross section of area. In order to decrease these excessive moment and deflection, the two-way beam string structures composed of H-Beam, strut, and cable elements were proposed. In the two-way string beam, the cable with the prestress improves force distribution of some weight reduction. Two systems made of structural steel and cables were tested. The nonlinear behaviour of the two-way beam string structures studied by using finite element model and compared to experimental results. The displacement of the LVDT in the center of the beam correspond with the ABAQUS results. 2,200MPa cable can afford to bear breaking load than 1,860MPa cable. The two-way beam string structures is correlated to the finite element model and the experimental results. In consequence, It showed that the system with two-way cables exhibits much better structural performances than H-Beam structures and beam with cable.

An Experimental Study on Behavior of Multi-Spliced Girder with Dry Joint (건식접합부를 갖는 Multi Spliced 주형의 거동에 관한 실험적 연구)

  • Kim Kwang-Soo;Seo Bong-Won;Park Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.229-236
    • /
    • 2005
  • To cope with increasing requirements of cost reduction, labor saving, and rapid construction, the purpose of this study is to investigate the structural behavior of PSC monolithic and spliced girders. Three tests were conducted on reduced-scale girder specimens having same type. This paper presents the result of experimental studies on the load-deflection behavior in which different joint and amount of tendon as major variables were investigated. The first one used a monolithic girder was arranged with three tendons. The second one used a spliced girder was joined with three tendons after producing five segments. And the third girder was produced in same conditions with the second girder and arranged with additional tendons. The experimental results show the difference of behavior between monolithic and spliced girders.

Experimental Analysis of Prestressed Approach Slab Behavior (프리스트레스가 도입된 접속슬래브의 실험적 거동 분석)

  • Park, Hee-Beom;Eum, In-Sub;Kim, Seong-Min
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.157-164
    • /
    • 2010
  • This research was conducted to analyze the behavior of Single-PTAS (Single Post-Tensioned Approach Slab) under tensioning and environmental loads by performing field tests when the demonstration Single-PTAS was being constructed. The temperature measurement sensors were installed at different depths, and the displacements in the approach slab under environmental loads and tensioning were measured using displacement transducers. As an experimental result, an abrupt change in the longitudinal displacement due to tensioning was not observed. The daily temperature change in the approach slab was negligible where the depth is over about 35cm. The temperature gradient in the approach slab adjacent to bridge was smaller than that adjacent to pavement. The patterns and magnitudes of vertical displacements were directly related to the temperature gradient at the measuring location. The behavior of Single-PTAS was very similar to that of concrete pavement. Therefore, a new design methodology for approach slabs is needed to include the pavement concept and to overcome drawback of current design procedures based on the simple beam concept.