• 제목/요약/키워드: pressure tube

검색결과 2,124건 처리시간 0.031초

BTA드릴가공의 절삭성능에 관한 연구 (A Study on Cutting Performance of the BTA Drilling)

  • 장성규;김순경;전언찬
    • 한국정밀공학회지
    • /
    • 제15권10호
    • /
    • pp.65-72
    • /
    • 1998
  • The BTA drilling chip is better for deep hole drilling than other self-piloting with pad drilling chips because the large length to diameter ratio allows a unique cutting force dispersion and better supplies the high pressure fluid. Therefore the BTA is useful for many tasks, such as coolant hole drilling of large scale dies, as well as tube seat drilling, which is essential for the heat exchanger, and variable component drilling for automobiles. Deep hole drilling has several significant problems, such as hole deviation, hole over-size, circularity, straightness, and surface roughness. The reasons for these problems, which often result in quality short comings, are an alignment of the BTA drilling system and the unbalance of cutting force by work piece and tool shape. This paper analyzes the properties through an experiment which com¬pared single-edge BTA drills with multiple-edge BTA drills, as well as the shapes of the tools to cause an unbalance of cutting force, and its effect on the precision of the worked hole. Conclusions are as follows. 1) In SMSSC drilling, 60m/min of BTA with single and multi-edged tools proved the best cutting condition and the lowest wear character. 2) The roundness got a little worse as cutting speed was increased, but surface roughness was hot affected. 3) It was proved that the burnishing torque of both drills approached 26%. which is almost the same as the 24% insisted on by Griffiths, and the dispersion characteristic of the multi-edged BTA drill proved better than the single-edge BTA drill.

  • PDF

CFT 기둥의 축력비 및 압축강도 변화에 따른 화재거동 영향인자에 관한 실험적 연구 (An Experimental Study on the Fire Resistance effect on load ratio and compressive strength of the CFT Column under loading in fire)

  • 조경숙;김흥열;김형준;권인규;박경훈
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.371-376
    • /
    • 2010
  • The strength of steel material in a concrete filled steel tube (CFT) is reduced in fire, but the filled interior concrete structurally ensures the fire resistance due to its high thermal capacity. More, the contractibility of CFT is excellent since it can be constructed without form work. This research analyzed the interior concrete strength and deformation characteristics, which are the influence factors of the fire resistance of CFT, in proportion to the axial load ratio. The fire resistance performance according to changes of the axial load ratio showed great fluctuation. As $280{\times}280{\times}6$ CFT columns with the concrete strengths of 24 MPa and 40 MPa and the axial load ratios of 0.9, 0.6, and 0.2 in accordance with KS F 2257-1 and 7 were heated with loading to examine the fire resistance performance, the 24 MPa concrete exhibited the fire resistance time as 27, 113, and 180 minutes for the axial load ratios, 0.9, 0.6, and 0.2 respectively. In case of 40 MPa concrete, the fire resistance time were turned out to be 19 and 28 minutes for the axial load ratios, 0.9 and 0.6 respectively. The results of 40 MPa concrete showed the much lower fire resistance performance when comparing with those of 24 MPa concrete. The fire resistance performance was not increased significantly when the axial load ratio was reduced. Therefore, the deceased fire resistance performance of high strength concrete is assumed to be caused by the internal pressure increase upon the heat application.

  • PDF

The detection of cavitation in hydraulic machines by use of ultrasonic signal analysis

  • Gruber, P.;Farhat, M.;Odermatt, P.;Etterlin, M.;Lerch, T.;Frei, M.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권4호
    • /
    • pp.264-273
    • /
    • 2015
  • This presentation describes an experimental approach for the detection of cavitation in hydraulic machines by use of ultrasonic signal analysis. Instead of using the high frequency pulses (typically 1MHz) only for transit time measurement different other signal characteristics are extracted from the individual signals and its correlation function with reference signals in order to gain knowledge of the water conditions. As the pulse repetition rate is high (typically 100Hz), statistical parameters can be extracted of the signals. The idea is to find patterns in the parameters by a classifier that can distinguish between the different water states. This classification scheme has been applied to different cavitation sections: a sphere in a water flow in circular tube at the HSLU in Lucerne, a NACA profile in a cavitation tunnel and two Francis model test turbines all at LMH in Lausanne. From the signal raw data several statistical parameters in the time and frequency domain as well as from the correlation function with reference signals have been determined. As classifiers two methods were used: neural feed forward networks and decision trees. For both classification methods realizations with lowest complexity as possible are of special interest. It is shown that two to three signal characteristics, two from the signal itself and one from the correlation function are in many cases sufficient for the detection capability. The final goal is to combine these results with operating point, vibration, acoustic emission and dynamic pressure information such that a distinction between dangerous and not dangerous cavitation is possible.

다공관 출구로부터 방사된 충격성 소음의 전파특성에 관한 실험적 연구 (An Experimental Study on the Propagation Characteristics of the Impulse Noise from the Exit of a Perforated Pipe)

  • 허성욱;이명호;이동훈;황윤
    • 한국추진공학회지
    • /
    • 제7권3호
    • /
    • pp.15-21
    • /
    • 2003
  • 본 연구에서는 다공관의 출구로부터 전파하는 충격성 소음의 전파특성을 실험적으로 파악하였다. 다공관은 공극율, 구멍지름 그리고 관의 길이를 각기 다르게 제작하여 충격파 관 출구에 부착하여 실험하였다. 충격파 전파마하수는 실제의 적용조건을 참고하여 1.02-1.2의 범위로 하였다. 지향성은 근음장과 원음장으로 구분하여 측정하였다. 또한 충격성 소음원인 펄스파의 전파과정을 조사하기 위하여 쉴리렌 광학장치를 이용하였다. 실험결과로부터 다공관의 소음저감 성능은 음장조건에 좌우됨을 알았다. 즉 근음장 조건에서는 다공관의 공극율과 관의 길이가 소음저감에 다소간의 영향을 미치지만, 원음장 조건에서는 다공관이 충격성 소음의 저감에 거의 기여하지 못하였다. 이와 같이 음장조건에 따라 충격성 소음의 저감성능이 다르게 되는 것은 근음장 조건에서는 관축방항으로 강한 지향성을 보이지만, 원음장 조건에서는 모든 방향으로 같은 세기로 전파하는 무지향성이기 때문이다.

ROLE OF PASSIVE SAFETY FEATURES IN PREVENTION AND MITIGATION OF SEVERE PLANT CONDITIONS IN INDIAN ADVANCED HEAVY WATER REACTOR

  • Jain, Vikas;Nayak, A.K.;Dhiman, M.;Kulkarni, P.P.;Vijayan, P.K.;Vaze, K.K.
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.625-636
    • /
    • 2013
  • Pressing demands of economic competitiveness, the need for large-scale deployment, minimizing the need of human intervention, and experience from the past events and incidents at operating reactors have guided the evolution and innovations in reactor technologies. Indian innovative reactor 'AHWR' is a pressure-tube type natural circulation based boiling water reactor that is designed to meet such requirements, which essentially reflect the needs of next generation reactors. The reactor employs various passive features to prevent and mitigate accidental conditions, like a slightly negative void reactivity coefficient, passive poison injection to scram the reactor in event of failure of the wired shutdown systems, a large elevated pool of water as a heat sink inside the containment, passive decay heat removal based on natural circulation and passive valves, passive ECC injection, etc. It is designed to meet the fundamental safety requirements of safe shutdown, safe decay heat removal and confinement of activity with no impact in public domain, and hence, no need for emergency planning under all conceivable scenarios. This paper examines the role of the various passive safety systems in prevention and mitigation of severe plant conditions that may arise in event of multiple failures. For the purpose of demonstration of the effectiveness of its passive features, postulated scenarios on the lines of three major severe accidents in the history of nuclear power reactors are considered, namely; the Three Mile Island (TMI), Chernobyl and Fukushima accidents. Severe plant conditions along the lines of these scenarios are postulated to the extent conceivable in the reactor under consideration and analyzed using best estimate system thermal-hydraulics code RELAP5/Mod3.2. It is found that the various passive systems incorporated enable the reactor to tolerate the postulated accident conditions without causing severe plant conditions and core degradation.

고온, 고압 알칼리 수용액에서의 Alloy 600 산화막 특성에 미치는 납 농도 영향 (Effect of Lead Concentration on Surface Oxide Formed on Alloy 600 in High Temperature and High Pressure Alkaline Solutions)

  • 김동진;김현욱;문병학;김홍표;황성식
    • Corrosion Science and Technology
    • /
    • 제11권3호
    • /
    • pp.96-102
    • /
    • 2012
  • 0.1 M NaOH 용액에 PbO첨가양이 증가함에 따라 Alloy 600에 형성되는 산화막의 부동태 피막 특성이 열화되었다. 또한 뚜렷한 2중층 구조의 산화막이 점차 사라지고, 산화막내 존재하는 납의 양이 증가하였다. 산화막 내부 납의 양이 증가함에 따라 산화막 내부 니켈의 결핍이 점차 커졌다. 납에 의해 산화막의 부동태 특성이 약화됨에 따라, 응력부식균열 저항성 또한 급감하였을 것으로 판단된다.

개의 초기 원발성 녹내장안에서 Ahmed valve 이식술의 적용 (Ahmed Valve Implantation for Early Glaucoma Treatment in Dogs)

  • 박신애;정만복;박영우;김원태;김세은;서강문
    • 한국임상수의학회지
    • /
    • 제25권5호
    • /
    • pp.385-390
    • /
    • 2008
  • The purpose of this study was to compare the long term prognosis of Ahmed valve implantation and medical therapy in dogs with early primary glaucoma. The medical records of dogs with early primary glaucoma from the Veterinary Medical Teaching Hospital of Seoul National University between January 2005 and May 2008 were reviewed. Five dogs underwent Ahmed valve implantation and medical therapy was performed in six dogs. Breeds of the dogs included Shih Tzu(n = 7), American cocker spaniel(n = 2), and miniature poodle(n = 2). Adequate intraocular pressure(IOP) was better maintained in the Ahmed valve implantation group than in the medical treatment group throughout the follow-up period. Mean time for vision loss to develop after treatment in the Ahmed valve implantation group($198.0{\pm}115.4$ days) was significantly longer than that in medical treatment group($43.2{\pm}30.4$ days, p < 0.05). Post-operative complications included occlusion of the tube by fibrin in the anterior chamber (n = 1), fibrous capsule about the episcleral base of the device(n = 1), and dislocation of the valve body(n = 1). It is considered that Ahmed valve implantation is more effective strategy to control IOP and maintain vision than medical treatment in early glaucomatous dogs.

The Kwinana Shoreline Fumigation Experiment in Western Australia, Australia

  • Yoon, I.H.;Sawford, B.L;Manins, P.C.
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 1996년도 봄 학술발표회 초록집
    • /
    • pp.22-22
    • /
    • 1996
  • ;The Kwinana Shoreline Fumigation Experiment(KSFE) took place in Fremantle, WA, Australia between 23 January and 8 February, 1995. All measurement systems performed to expectation. The CSIRO DAR(Division of Atmospheric Research) LIDAR measured plume sections from near the Kwinana Power Station(KPS) stacks to up to about 5 km downstream. It also measured boundary layer aerosols and the structure of the boundary layer on some occasions. Both stages A and C of KPS were used as tracers at different times. Radiosonde and double theodolite sounding systems measured temperature, humidity, air pressure and wind structure at the coast(Woodman Point) and at the inland(ALCOA residue dump) site at intervals of roughly two hours. These were supplemented by mid afternoon soundings(radiosonde and single theodolite) by Department of Environmental Protection(DEP) at Swanbourne. The Flinders aircraft measured wind, turbulence and temperature structure of the atmospheric boundary layer, concentrations of $C0_2,\;0_3,\;S0_2\;and\;NO_x$ in the smoke plumes and surface radiation over both land and sea. CSIRO DCET(Division of Coal and Energy Technology) vehicle successfully interceptde many smoke plumes and using a range of tracers will be able to identify the various sources much of the time. Routine data from the DEP and Kwinana Industrial Council(KIC) air quality monitoring networks were also automatically logged. Murdoch University measured surface heat flux at Hope Valldy monitoring station and also at Wattleup monitoring station for the last five days. The heart of the LIDAR system is a Neodymium-doped Yttrium-aluminumgarnet(Nd:Y AG) laser operating at a fundamental wavelength of 1064 nm, with harmonics fo 532 nm and 355 nm. A small fraction of the laser beam is scattered back to the LIDAR, collected by a telescope and detedted by a photomultiplier tube. The intensity of the signal as a function of time is a measure of the particle concentration as a function of distance along the line of the laser shot. The results of nine days special field observations are summarized in detail.etail.

  • PDF

이중 분지관내 혈액 및 혈액대용유체의 3차원 유동해석 (3-D Flow Analysis of Blood and Blood Substitutes in a Double Branching Model)

  • 서상호;유상신;노형운
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권2호
    • /
    • pp.187-196
    • /
    • 1997
  • The three-dimensional flow analysis using the finite volume method is presented to compare the steady flow characteristics of blood with those of blood substitutes such as water and aqueous polymer solution in an idealized double branching model. The model is used to simlllate the region of the abdominal aorta near the celiac and superior mesenteric branches. Apparent viscosities of blood and the aqueous Separan solution are represented as a function of shear rate by the Carreau model, Water and aqueoiu Separan AP-273 500wppm solution are frequently used as blood substitutes in vitro experiments. Water is a typical Newtonian fluid and blood and Separan solution are non-Newtonian fluids. Flow phenomena such as velocity distribution, pressure variation and wall shear stress distribution of water, blood and polymer solution are quite different due to differences of the rheological characteristics of fluids. Flow phenomena of polymer solution are qualitatively similar to those of blood but the phenomena of water are quite different from those of blood and polymer solution. It is recommended that a lion-Newtonian fluid which exhibits very similar rheological behavior to blood be used in vitro experiments. A non-Newtonian fluid whose rheological characteristics are very similar to those of blood should be used to obtain the meaninylll hemodynamic data for blood flow in vitro experiment and by numerical analysis

  • PDF

선천성 심장질환을 가진 다운증후군환자에서 치과치료를 위한 전신마취 시 산소포화도 하강 -증례보고- (DECREASE OF OXYGEN SATURATION DURING DENTAL TREATMENT UNDER GENERAL ANESTHESIA OF DOWN SYNDROME PATIENT WITH CONGENITAL HEART DISEASE -A CASE REPORT-)

  • 서광석;장주혜;신터전;김현정
    • 대한장애인치과학회지
    • /
    • 제5권1호
    • /
    • pp.18-22
    • /
    • 2009
  • A 26-year-old female patient with Down syndrome visited to recieve dental treatment under gnenral anesthesia 6 years ago. The patient had difficulties in oral examination, radiograph taking and laboratory test. The patient had congenital heart disease and medical consultation based on the echocardiography was provided by a cardiologist indicating that the patient could tolearte general anesthesia during dental treatment. And two times of general anesthesia were administered during a dental treament with the interval of 3 years and no postoperpative complicaton was reported. At the third dental operation, the patient had a relatively good condition and her prescreening test revealed no abnormalities. Without further consultation with a cardiologist, general anesthesia was administered to the patient. Anaesthesia was based on thiopental and ventilation of desflurane and $N_2O$ in oxygen via an endotracheal tube with an appropriate monitoring. During the maintenance of anesthesia, the blood pressure of the patient started to drop and the oxygen saturation also began to decrease. Consequently, the proceding operation was discontinued and also inhalation anesthesia was ceased. As the patient was recovered from anesthesia, her systemic conditions were alleviated. After the complete recovery of the patient, she visited the cardiologist, and the cardiologic test revealed her severe right ventricular dilatation. In the anesthesia of patients with congenital heart disease, information on their systemic conditions needs to be undated from the medical consultation, which assures the safety of treatment.

  • PDF