• Title/Summary/Keyword: pressure rise rate

Search Result 280, Processing Time 0.025 seconds

An Experimental Study on Expansion of Operation Range by Lean Boosting for a HCCI H2 Engine (희박과급에 의한 수소 예혼합 압축착화 기관의 운전영역 확장에 관한 실험적 연구)

  • Ahn, Byunghoh;Lee, Jonggoo;Lee, Jongmin;Lee, Jongtai
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.6
    • /
    • pp.573-579
    • /
    • 2013
  • Hydrogen engine with homogeneous charged compression ignition can achieve high efficiency by high compression ratio and rapid chemical reaction rates spatially. However, it needs to expansion of the operation range with over-all load conditions which is very narrow due to extremely high pressure rise rate. The adoption of the lean boosting in a HCCI $H_2$ engine is expected to be effective in expansion of operation range since minimum compression ratio for spontaneous ignition is decreased by low temperature combustion and increased surround in-cylinder pressure. In order to grasp its possibility by using lean boosting in the HCCI $H_2$ engine, compression ratio required for spontaneous ignition, expansion degree of the operation range and over-all engine performance are experimentally analyzed with the boosting pressure and supply energy. As the results, it is found that minimum compression ratio for spontaneous ignition is down to the compression ratio(${\varepsilon}$=19) of conventional diesel engine due to decreased self-ignition temperature, and operation range is extended to 170% in term of the equivalence ratio and 12 times in term of the supply energy than that of naturally aspirated type. Though indicated thermal efficiency is decreased by reduced compression ratio, it is over at least 46%.

A Numerical Study on Performance Improvement of Canopy Hood in Melting Process (용해공정의 캐노피 후드 성능 개선에 관한 수치 해석적 연구)

  • Jung, Yu-Jin;Shon, Byung-Hyun;Lee, Sang-Man;Jung, Jong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1519-1526
    • /
    • 2013
  • This study reviewed the capturing performance of a canopy hood used in some melting processes of a casting manufacturing factory through a site survey. In addition, this study compared and evaluated the flow field and pressure field for the plans to enhance the hazardous air pollutants collection capacity by using CFD model. The case-2(flange attached + double hood) can be improved in terms of collection performance, but is expected to increase in hood static pressure by about 70% more than the existing structure, so it was shown that its site applicability is not good. It is judged that the shape of case-3(flange attached + double cone attached) is most suitable to improve the suction efficiency. This is because a double cone is installed at the center of the opening to concentrate the flow rate on the edge of the hood and control the hume rising to the center of the hood without a static pressure rise via the slope of the cone.

The Kientic Study of Ozone$(O_3)$ with Sulfur Trioxide#(SO_3)$ in the Gas Phase (기체상태에서의 오존$(O_3)$과 삼산화황$(SO_3)$의 반응연구)

  • Kwon Young Sik
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.644-651
    • /
    • 1992
  • The kinetics of the gas phase reaction of ozone(∼0.5 torr) with sulfur trioxide was investigated in the range of 6∼12 torr pressure at 69∼150${\circ}C$. The reaction rate of ozone with sulfur trioxide was faster than the reaction rate of $O_3 in the presence of CO_2 alone. No evidence for a molecular reaction of O_3 with SO_3 was found and the faster rate is probably due to impurity (HX) from the SO_3 reactant which gives rise to a chain reaction initiated by O_3 + HX → OH + O_2 + X and also SO_3 has a larger collision diameter, which may be attributed to the O3 thermal decomposition more feasibly. The proposed experimental law [-d(O_3)/dt] = k_a(SO_3)(O_3) + k_b(O_3)^{3/2} gives a rate constant ka(M-1 s-1) = (1.55 {\pm} 0.67) {\times} 105 e-{(9.27 0{\pm}0.43)kcal/RT}.$

  • PDF

Effects of Nonequilibrium Condensation on an Oblique Shock Wave in a Supersonic Nozzle of Constant Expansion Rate (팽창률이 일정한 초음속 노즐흐름에 있어서 비평형 응축이 경사충격파에 미치는 영향)

  • 강창수;권순범;김병지;홍종우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1311-1319
    • /
    • 1990
  • For the purpose of preventing the flow undulation in the cascade of steam turbine, the blades are made into a constant expansion rate in static pressure. And the flow in those cascades is transonic or supersonic in the range of 0.7-2.0 in Mach number. As a consequence, an oblique shock wave, known as inner or outer edge shock wave, arises in the flow of cascades. Especially when the steam in cascades is in a state of high wetness, nonequilibrium condensation and condensation shock wave occur, and they give rise to an interference with oblique shock wave. In the present study the case of expansion of moist air through a supersonic nozzle of constant expansion rate, which behaves similar to that of wet steam, was adopted. The effect of nonequilibrium condensation on the oblique shock wave generated by placing the wedge into the supersonic part of the nozzle was investigated. Furthermore, the relationship between nonequilibrium condensation zone and incident point of the oblique shock wave, oblique shock wave angle, the variations of angles of incident and reflected shock waves due to the variation of initial stagnation supersaturation and the relationship between the height of Mach stem and initial stagnation supersaturation are discussed.

A Pulser System with Parallel Spark Gaps at High Repetition Rate

  • Lee, Byung-Joon;Nam, Jong-Woo;Rahaman, Hasibur;Nam, Sang-Hoon;Ahn, Jae-Woon;Jo, Seung-Whan;Kwon, Hae-Ok
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.305-312
    • /
    • 2011
  • A primary interest of this work is to develop an efficient and powerful repetitive pulser system for the application of ultra wide band generation. The important component of the pulser system is a small-sized coaxial type spark gap with planar electrodes filled with SF6 gas. A repetitive switching action by the coaxial spark gap generates two consecutive pulses in less than a microsecond with rise times of a few hundred picoseconds (ps). A set of several parameters for the repetitive switching of the spark gap is required to be optimized in charging and discharging systems of the pulser. The parameters in the charging system include a circuit scheme, circuit elements, the applied voltage and current ratings from power supplies. The parameters in the discharging system include the spark gap geometry, electrode gap distance, gas type, gas pressure and the load. The characteristics of the spark gap discharge, such as breakdown voltage, output current pulse and recovery rate are too dynamic to control by switching continuously at a high pulse repetition rate (PRR). This leads to a low charging efficiency of the spark gap system. The breakthrough of the low charging efficiency is achieved by a parallel operation of two spark gaps system. The operational behavior of the two spark gaps system is presented in this paper. The work has focused on improvement of the charging efficiency by scaling the PRR of each spark gap in the two spark gaps system.

The Motility of Esophagus in Acute Hemorrhage (급성실혈시의 식도운동)

  • Park, Soon-Il;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.6 no.2
    • /
    • pp.39-48
    • /
    • 1972
  • Two polyethylene tubes were inserted into the esophagus of anesthetized rabbit in order to record the fluctuation of the intraluminal pressure through the orifices located near the tips of the tubes. The orifice of the first tube was 10 cm apart from the incisor of the rabbit and the orifice of the second tube was 5 cm below that of the first one. The tubes were filled with saline solution running at various rates ranging from 1.5 ml/min. to 4.2 ml/min. The tubes were connected to the pressure transducers and the electrical signals were recorded by the physiograph. When the peristaltic wave approached to the orifice a rise in the pressure was recorded, returning to the base line when the portion of the orifice was quiescent. The frequency of the peristaltic motion and the velocity of the wave were studied in connection with the flow rate of saline solution through the tubes and in the case of massive acute hemorrhage. The results obtained were as follows: 1. There was reflux of fluid induced during the procedure of the experiment. This outwrad flow through the pharynx seemed to elicite swallowing reflexes. Accordingly, the frequency of peristalsis of the esophagus was largely dependent on the flow rate of the fluid through the inserted tubes. By the flow rate of 1.5 ml/min., 2.5 ml/min., or 4.2 ml/min., the frequencies of the peristalsis were revealed to be $8.6{\pm}3.6/10min.,\;14.5{\pm}4.8/10min.\;or\;21.1{\pm}6.3/10min.,$ respectively. The velocity of peristalsis also coincided with the enhanced motility of the esophagus, showing $6.6{\pm}1.5\;cm/sec.,\;8.9{\pm}3.9\;cm/sec.,\;or\;12.4{\pm}4.6\;cm/sec.,$ respectively. 2. By acute hemorrhage, amounting to 2% of the body weight, the frequency of the peristalsis increased to twofold of the control and the propagation velocity also increased by 52 percent. 3. Retransfusion of the shed blood resulted in divergent responses. In some cases there were noticable ameliorations of the effects brought by acute hemorrhage, and in the others there were still increasing tendenies of the motility after the transfusion. 4. Some speculation was made about the possibility of a kind of relationship between the irreversibility of the hemorrhagic shock and the absence of responses by transfusion. 5. The peristalsis persisted even after complete disconnection at the midportion of the esophagus, reaffirming the view of a central regulation of the spatiotemporally coordinated motility, peristalsis.

  • PDF

Comparative Study on the Efficiency of the Gas Discharge Lasers - Limiting Efficiency of Metal Vapor Lasers - (기체방전 레이저의 효율에 관한 연구 -금속증기레이저의 한계효율-)

  • 이재경
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.47-56
    • /
    • 1993
  • Practical efficiencies of pulsed gas discharge lasers utilizing vaporized Au, Ba, Cu, Fe, Mn, Pb, TI atoms are numerically optimized for a discharge pulse of 30 ns rise time at 5 kHz pulse repetition rate. Calculated optimum operating temperatures are close to the values at which the vapor pressure of each atom is about 1 Torr and are in good agreement with experimental values reported elasewhere. The optimum charging voltage was about 4 kV for all atomic vapor lasers except the TI laser. The calculated maximum efficiencies that have been discussed for possible limiting efficiencies for each laser were considerably higher than the reported experimental values. Especially, they were as high as 6.8% for Mn laser and 15% for Ba laser that were comparable to the 8.5% of copper vapor laser, from which considerably higher efficiencies can be expected for these two lasers experimentally. But, the present calculation shows a very low efficiency of 0.058% and requires an exceptional operating condition for the TI laser.

  • PDF

Development of Production Performance Forecasting Model Considering Pressure Dependent Permeability at Coalbed Methane Reservoir (석탄층 메탄가스전에서 압력 의존 투과도를 고려한 생산거동 예측 모델 개발)

  • Kim, Sangho;Kwon, Sunil
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.7-19
    • /
    • 2019
  • In this study, a model was developed for estimating deliverability considering the pressure dependent permeability and predicting production profile with Material Balance Equation(MBE) for Coalbed Methane(CBM) fields. The estimated deliverability was compared with the conventional deliverability based on CBM well testing data with coefficient of determination($R^2$). As a result, the former was 0.76 and the latter was 0.69. It was confirmed that the deliverability which consider the pressure dependent permeability is more adoptable when representing the productivity of CBM fields. Through this process, in order to calculate pressure dependent permeability when well testing data exist, a method to infer reservoir pressure within the radius of investigation was proposed. The production profile of 31 gas wells was predicted for 15 years, using the estimated deliverability and the MBE. After that, the results was compared with simulation results of the literature. The simulation results did not account the pressure dependent permeability and the developed model results considered that. As the applied field permeability rised 1.17 times, field production rate was increased approximately 15% than the literature results. According to other researches, the permeability of CBM fields can be rise 6 ~ 25 times. For these cases, the production profiles may have significant difference with conventional gas fields.

The Effects of Acute Hemorrhage on Cardiopulmonary Dynamics in the Hypothermic Dog (급성사혈이 저온견의 심폐동태에 미치는 영향)

  • Lee, Jae Woon
    • Journal of Chest Surgery
    • /
    • v.2 no.1
    • /
    • pp.85-104
    • /
    • 1969
  • This experiment was carried out to study the effect of rapid hemorrhage on cardiopulmonary hemodynamics of the cooled dogs. Hypothermia was induced by means of body surface cooling with ice water. Lowest esophageal temperatures ranged from 24 to 26 degree. Dogs were bled via the femoral artery into a reservoir in amount of the equivalent blood volume of 3% of body weight of the dogs. Some dogs were reinfused with the same amount of blood which they lost and others infused with 5% dextrose solution. Fourty adult mongrel dogs were divided into three groups: group I[15 dogs]; dogs were bled in normothermic state. Five dogs had no further treatment, but five dogs were reinfused with blood and five infused with 5% dextrose solution 30 minutes after bleeding. GroupII[10 dogs]; dogs were bled as group I after having been cooled. Five dogs were reinfused with blood as group I. Group III[15 dogs]; dogs were first bled and then cooled. Reinfusion procedures were the same as in group l Results were as follow: 1. The heart rate showed a slight decrease after bleeding in group I and then increased over the control level after 60 minutes. After reinfusion and infusion, the heart rate was also increased gradually and after three hours almost returned to the control level. In group II and groupIll, the heart rate decreased remarkably and after reinfusion showed a light increase but after infusion tended to decrease cotinually. 2. The stroke volume showed remarkable decrease after bleeding in group I., and recovered to control level after reinfusion and infusion,and then gradually decreased again. In group III, the stroke volume showed no remarkable change after hypothermia, and tended to decrease after reinfusion. In group III, the stroke volume decreased remarkably after bleeding and hypothermia,and clearly increased after reinfusion and infusion and then returned to control level. 3. Femoral mean pressure declined very rapidly and significantly right after bleeding and showed a remarkable prompt rise after reinfusion and infusion in group I [67% recovery]. On the other hand, it declined remarkably after hypothermia and bleeding and showed a slight rise after reinfusion and infusion in group II[46% recovery] and III [41% recovery]. 4. Venous pressure declined slightly after bleeding and tended to return to the control level after reinfusion and infusion,in group I. In group II, it did not change significantly during hypothermia but showed a slight decline after bleeding and returned toward control level after reinfusion. In group III, it declined slightly after bleeding and showed no significant change after hypothermia and rose over the control level after reinfusion and infusion. 5. Right ventricular systolic pressure decreased markedly after bleeding and then increased progressively after 30 minutes. It increased after reinfusion and infusion as well, approaching the control level in group I. In group II, it showed no significant change during hypothermia, but decreased remarkably after bleeding and then returned to near control level after reinfusion. In group III, it was decreased markedly after bleeding but did not change significantly during hypothermia and showed a slight increase after reinfusion. 6. The respiratory rate increased gradually after bleeding and decreased gradually after reinfusion but did not return to the control level, whereas it decreased near to the control level after infusion,and tended to increase in group I. In group II, it decreased significantly after hypothermia and bleeding but returned near to the control level after reinfusion. In group III, it showed a remarkable decrease after hypothermia and increased slightly after reinfusion and infusion but did not returned to the control level. In group I, the tidal volume decreased slightly after hemorrhage, and increased gradually to near the control level after 3 hours following reinfusion.

  • PDF

Clinical Efficacy of Bevacizumab Concomitant with Pemetrexed in Patients with Advanced Non-small Cell Lung Cancer

  • Zhang, Yu-Mei;Li, Yong-Qiang;Liu, Zhi-Hui;Liao, Xiao-Li;Liang, Rong;Lin, Yan;Yuan, Chun-Ling;Liao, Si-Na;Liang, Chao-Yong;Li, Qian;Li, Le-Qun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3447-3450
    • /
    • 2014
  • Objective: To observe the clinical efficacy of bevacizumab concomitant with pemetrexed in patients with advanced non-small cell lung cancer (NSCLC). Materials and Methods: A total of 72 patients were randomly divided into a combination group (pemetrexed+bevacizumab, n=36) and a pemetrexed group (n=36) and assessed for disease control (CR+PR+SD) after 4-cycles of first-line GP chemotherapy (gemcitabine+cisplatin). Clinical efficacy, progression-free survival time (PFS), overall survival time (OS), overall response rate (ORR), disease control rate (DCR) and rate of adverse responses between two groups were observed and compared. Results: ORR and DCR were 27.8% and 83.4% in combination group, and 16.7% and 69.5% in the pemetrexed group, respectively, but there were no significant differences (P>0.05). PFS in combination group and pemetrexed group were 4.6 months and 3.9 months respectively (P=0.09), whereas OS in the combination group was 14 months, evidently higher than in the pemetrexed group (11 months, P=0.004). Adverse responses in both groups included high blood pressure, bleeding, thrombocytopenia, anemia, elevated transaminase, diarrhea, vomiting and proteinuria, but there were no significant differences (P>0.05). Conclusions: Bevacizumab concomitant with pemetrexed has better clinical efficacy and safety, giving rise to prolonged survival time in patients with advanced NSCLC.