• 제목/요약/키워드: pressure pulse

검색결과 1,214건 처리시간 0.03초

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

  • Kang, Hee-Jung;Lee, Yong-Heum;Kim, Kyung-Chul;Han, Chang-Ho
    • 대한한의학회지
    • /
    • 제30권3호
    • /
    • pp.98-105
    • /
    • 2009
  • Objective: Increased aortic and carotid arterial augmentation index (AI) is associated with the risk of cardiovascular disease. The most widely used approach for determining central arterial AI is by calculating the aortic pressure waveform from radial arterial waveforms using a transfer function. But how the change of waveform by applied pressure and the pattern of the change rely on subject's characteristics has not been recognized. In this study, we use a new method for measuring radial waveform and observe the change of waveform and the deviation of radial AI in the same position by applied pressure. Method: Forty-six non-patient volunteers (31 men and 15 women, age range 21-58 years) were enrolled for this study. Informed consent in a form approved by the institutional review board was obtained in all subjects. Blood pressure was measured on the left upper arm using an oscillometric method, radial pressure waves were recorded with the use of an improved automated tonometry device. DMP-3000(DAEYOMEDI Co., Ltd. Ansan, Korea) has robotics mechanism to scan and trace automatically. For each subject, we performed the procedure 5 times for each applied pressure level. We could thus obtain 5 different radial pulse waveforms for the same person's same position at different applied pressures. All these processes were repeated twice for test reproducibility. Result: Aortic AI, peripheral AI and radial AI were higher in women than in men (P<0.01), radial AI strongly correlated with aortic AI, and radial AI was consistently approximately 39% higher than aortic AI. Relationship between representative radial AI of DMP-3000 and peripheral AI of SphygmoCor had strongly correlation. And there were three patterns in change of pulse waveform. Conclusion: In this study, it is revealed the new device was sufficient to measure how radial AI and radial waveform from the same person at the same time change under applied pressure and it had inverse-proportion to applied pressure.

  • PDF

토노메트리 방식 맥파 측정의 가압 각도와 가압력에 따른 AIx 변화 (AIx Change According to Pressing Angle and Pressing Force of the Radial Artery Pulse by Tonometry)

  • 조정희;전영주;전민호;김영민
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.259-263
    • /
    • 2018
  • A radial artery pulse wave is measured while pressing an artery with constant force. However, pulse waveform measurements vary depending on pressing force and direction. Accurate pulse waveform measurements are important for analysis. Thus, it is necessary to define the measurement range of the permissible force and direction from which a correct pulse waveform is derived. In this study, pulse waves were generated by a pulse wave generator for accurate control. The pulse waves generated for different angles and pressing forces were analyzed. The augmentation index (AIx), which is the most commonly used index for evaluating vascular stiffness, was analyzed. The AIx was measured within ${\pm}6^{\circ}$ of the vessel direction and within ${\pm}8^{\circ}$ perpendicular to the vessel direction with a force that was 25% or more of the pressing force at which the maximum pressure wave was generated. We identified the applicable pressing force and angle range by analyzing the effect of pressing angle on the pulse wave. The AIx analysis performed using the pulse wave measurement device is reliable and reproducible.

극박 다이아프램의 펄스 GTAW 공정 최적화에 관한 연구 (Study on the Optimization of Pulse GTAW Process for Diaphragm with Thin Thickness)

  • 박형진;황인성;강문진;이세헌
    • Journal of Welding and Joining
    • /
    • 제26권1호
    • /
    • pp.63-68
    • /
    • 2008
  • This paper has aimed to prevent excessive heat input by controlling arc distribution and heat input capacity with pulse GTAW in order to improve weld quality in 0.08mm pressure gauge diaphragm and flange welding parts. A design of experiment was designed using Box-Behnken method to optimize a welding process. The pulse GTAW parameters such as pulse current, base current, pulse duty, frequency and welding speed were set to input variables while hydraulic pressure that represents welding characteristics in diaphragm and flange joint were set to output variables. Based on the test result, a second regression equation was obtained between input and output variables and turned out significant. Besides, an influence of parameters has been confirmed through response surface analysis using the second-order regression equation and optimum welding condition was obtained through a grid-search method. The optimum welding condition was set to pulse current 84.4(A), base current 29.6(A), pulse duty 58.8(%), frequency 10(%), and welding speed 596(mm/min). Then, decent bead shape was acquired with no excessive heat input under the $2.3kgf/cm^2$ of hydrostatic pressure.

고혈압 환자에서 화침법(和針法)의 혈압강하 효과 (The Depressive Effect of Hwa-acupuncture Treatment in Hypertension Patients)

  • 한창현;박경호;신미숙;신선화;최선미
    • Journal of Acupuncture Research
    • /
    • 제23권6호
    • /
    • pp.165-176
    • /
    • 2006
  • Objectives : Aim of this study was to investigate the antihypertensive effect of Korean Hwa-Acupuncture in hypertensive patients. Methods: We measured the blood pressure of 14 patients who were admitted in the Oriental Medical Clinic of Balance & Harmony Korean Acupuncture Association from 25th March 2006 to 21th July 2006. Eligible participants had systolic blood pressure ${\geq}120mmHg$ diastolic blood $pressure{\geq}80mmHg$. Blood pressure and pulse rate measurements were after the patient had been bed rest for at least 30 min. 10 times of Hwa-Acupuncture treatment over 3 weeks period were performed in the patiants. To evaluate the effect of the Hwa-Acupuncture, the blood pressure, pulse rate were measured 2 times before and after each acupuncture treatment for total of 10 times. Results : After 3 weeks, there were significant decreased in the systolic blood pressure(P<0.0297) and significant decreased in diastolic blood pressure(P<0.0223) treated by Hwa-Acupuncture 10 times but pulse rate was failed to decreased. The effects of Hwa-Acupuncture by measuring time on blood pressure were as follows : systolic blood pressure were deceased significantly from 1st to 10th visit (P<0.0207) but diastolic blood pressure and pulse rate was not decreased significantly. Conclusion : The results suggest that Hwa-Acupuncture is effective in decreasing the systolic blood pressure.

  • PDF

고혈압 환자에서 곡운침법의 혈압강하 효과 (Gogoon acupuncture for hypertension)

  • 한창현;송태원;신미숙;신선화;최선미
    • Korean Journal of Acupuncture
    • /
    • 제24권1호
    • /
    • pp.27-41
    • /
    • 2007
  • Objectives : The aim of this study was to investigate the antihypertensive effect of Korean Gogoon Acupuncture in hypertensive patients. Methods : We measured the blood pressure of 17 patients who were admitted in the Oriental Medical Clinic of Gogoon Institute from 14th April 2006 to 29th August 2006. Eligible participants had systolic blood pressure ${\geq}120$ mmHg or diastolic blood $pressure{\geq}80$ mmHg. Blood pressure and pulse rate measurements were after the patient had been in bed rest for at least 30 min. Six sessions of Gogoon Acupuncture treatment over three weeks were performed in the patients. Blood pressure and pulse rate were measured twice before and after each acupuncture treatment. Results : After 3 weeks, there were significant decreases in systolic blood pressure(p=0.0028), diastolic blood pressure (p=0.0111) and pulse rate (p=0.0150). The effects of Gogoon Acupuncture by measuring time on blood pressure were as follows : In a systolic blood pressure (p<.0001) and diastolic blood pressure (p=0.0028) was gradually deceased significantly from 1st to 6th but pulse rate was not significantly decreased. Conclusions : Controlled trials investigating the efficacy of Gogoon acupuncture for lowering blood pressure are warranted.

  • PDF

사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구 (Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system)

  • 박승욱;김태형;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권3호
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

출혈을 일으킨 흰쥐에서의 PTT와 수축기 혈압 비교 (The Comparison of PTT and Systolic Blood Pressure in a hemorrhaged Rat)

  • 심영우;이주형;양동인;김덕원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.138-140
    • /
    • 2009
  • Hemorrhage shock occupies high rate in trauma patient's mortality and blood pressure is the variance that judges early diagnosis and the effect of remedy. Systolic blood pressure is related to pulse transit time(PTT). PTT means the time that is required to flow from the heart to peripheral artery. PTT is influenced from the length, cross section and stiffness of the blood vessels. It is hard to evaluate the correlation between systolic blood pressure and PTT because they are variable in human body. In this paper, we evaluated the correlation between the systolic blood pressure and PTT in normal and hemorrhage states using standardized rat. PTT is defined as the time differences between the R peak and the peak of pulse wave. The analyzed time differences of ECG and blood pressure are analyzed every 5minutes for 30 seconds when there is before and after bleeding. Before bleeding, systolic blood pressure and PTT are steadily preserved but when the bleeding comes started, systolic blood pressure is declined. However PTT was increased and decreased. Under the circumstance that the standardized rat is controlled by age, the length of the blood vessels, and any disease, it shows that PTT measurement using systolic blood pressure of bleeding is impossible.

  • PDF

충격기류식 여과집진장치에서 벤츄리가 압력손실에 미치는 영향 (Prediction of Venturi Effect on Pressure Drop in Pulse Air Jet Bag Filter)

  • 정문섭;김정권;정용현;서정민
    • 한국환경과학회지
    • /
    • 제32권9호
    • /
    • pp.659-669
    • /
    • 2023
  • The purpose of this study is to predict the pressure drop due to the installation of venturi under diverse operating conditions such as dust concentration, pulse interval and pressure, and filtration velocity using algebraic-linear regression model and use it as an economic data and efficient operating condition for a pulse air jet bag filter. A pilot scale bag filter with a filter a filter size(Ø140 × 850ℓ, 12) was used, and the filters used in the experiment were the polyester filters most commonly used in real industrial sites. The SAS 9.4 program (SAS Institute, USA) was used to predict and to determine the effects of inlet concentration (Ci), pulse interval (Pi) and pressure (Pp), filtration velocity (Vf), presence or absence of venturi, etc. The results are shown below. The variation in pressure drop with or without venturi installation was 38.8 mmAq when venturi is installed and 47.6 mmAq when venturi is not installed, indicating a difference in pressure drop of 8.8 mmAq depending on venturi installation. It is estimated that the efficiency can be improved by about 18.5% if the venturi is installed.

SHPB 기법에서 Pusle shpaer 가 내유 고무(NBR)의 동적 변형 거동에 미치는 영향 (Effect of pulse shaper in SHPB technique on dynamic deformation behavior of an NBR rubber)

  • 김성현;이억섭;이종원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.634-637
    • /
    • 2004
  • This paper presents a Split Hopkinson Pressure Bar(SHPB) technique to obtain compressive stress-strain data for rubber materials. An experimental technique that modifies the conventional Split Hopkinson Pressure Bar(SHPB) has been developed for measuring the compressive stress-strain responses of materials with low mechanical impedance and low compressive strengths such as rubber. This paper introduces an all-polymeric pressure bar which achieves a closer impedance match between the pressure bar and the specimen materials. In addition, we are a pulse shaper to lengthen the rising time of the incident wave to ensure stress equilibrium and homogeneous deformation of a rubber materials. It is found that the modified technique can be determine the dynamic deformation behavior of an NBR rubber more accurately.

  • PDF

측정 자세 및 상완 혈압에 의한 맥파 특성 변화 (Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure)

  • 남기창;김은근;허현;허영
    • 감성과학
    • /
    • 제12권3호
    • /
    • pp.299-306
    • /
    • 2009
  • 본 연구에서는 비침습적으로 압력 맥파를 검출하는 토노메트리 방식의 맥파 측정 장비인 SphygmoCor(AtCor, Australia)를 사용하여 측정자세에 따라 맥파를 측정하였다. 측정 결과를 통해 선 자세, 앉은 자세, 누운 자세에 따른 맥파의 분석 지표들의 변화를 분석하였다. 또한 측정된 데이터를 저혈압군, 정상혈압군, 고혈압군으로 구분하여 혈압군에 따른 맥파의 비교를 수행하였다. 그 결과 자세에 따른 요골동맥의 파형에서 유의차를 보인 분석지표는 맥파의 진폭에 해당되는 압력 보다 주요 피크가 발생되는 시간에서 나타났다. 맥압의 경우 맥파증대계수(AI)나 중심동맥압과 요골동맥압의 비율과 같이 맥압 간의 비율이 자세에 따른 변별력이 있었다. 사후검정에 따라 각 자세별로 상호 간에 모두 유의한 차이를 보인 분석지표는 주파(P_$T_1$)와 반사파(P_$T_2$)의 시간, 심박출지속시간(ED), 심박수(HR)로 나타났다. 혈압군에 대한 비교에서 대부분 맥파의 시간에 해당되는 지표보다 주요 피크의 진폭에 해당되는 맥파의 압력을 나타내는 지표가 혈압군에 따른 유의차를 보였다.

  • PDF