• Title/Summary/Keyword: pressure pulse

Search Result 1,215, Processing Time 0.034 seconds

Experiment and adiabatic analysis of miniature inertance pulse tube refrigerator (소형 관성관형 맥동관 냉동기의 실험 및 단열 해석)

  • 남중원;남관우;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.53-58
    • /
    • 2004
  • A Miniature inertance pulse tube refrigerator was designed and tested with a 10 W compressor. Erperiments were carried out for different pulse tube length and inertance tube length. An adiabatic model which considered the pressure drop in the regenerator was used to analyze the performance of the pulse tube refrigerator. Among various design parameters which should be optimized, the pulse tube length and the inertance tube length were optimized. PdV work and several different loss mechanism were included in the analysis to simulate more accurately the physical phenomena in the pulse tube refrigerator. Nevertheless, the simulation program could not completely predict the porformance of the refrigerator. The possible reason for the difference of the optimal point between the simulation and the experiment was explained.

A study on Radial pulse diagnosis of the korean medicine (한방 맥 진단에 관한 연구)

  • Lee, H.J.;Kim, J.W.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.71-74
    • /
    • 1992
  • This paper describes research about the realization of computerized radial pulse diagnosis system in order to remove the subjectivity of a diagnostician, when diagnostician diagnoses a sickness using tactile percept ion in korean traditional medicine. Using radial pulse wave detection system, we effectively measured pressure radial pulse rave and after analyzing it, we detected the characteristic parameters and also quantified it and then we objectified more or less the judgement standard of radial pulse diagnosis by the aids of a clinical expert. on this base, we confirmed the possibility for realizing of automatic radial pulse diagnosis by radial pulse diagnosis system.

  • PDF

Effect of Auxiliary Address Pulse on Face-to-face Sustain Electrode Structure in AC-PDP

  • Kim, Bo-Sung;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.605-608
    • /
    • 2007
  • The discharge characteristics of the face-to-face sustain electrode structure employing auxiliary address pulse are investigated under a sustain driving frequency of 20 kHz and various auxiliary address pulse widths (500 ns, $1{\mu}s$, $2\;{\mu}s$) in the 6-in. test panel (42-in. Full HD grade) with a pressure of 450 Torr and a 4 % Xe-content. The luminance and the luminous efficiency at the auxiliary address pulse width of 500 ns are improved more than these of $1\;{\mu}s$ and $2\;{\mu}s$. At the auxiliary address pulse width of 500 ns, the luminous efficiency shows about 0.96 lm/W at the auxiliary pulse of 90 V and the sustain voltage of 260 V.

  • PDF

Effects of Acupuncture Stimulation on the Radial artery's Pressure Pulse Wave in Healthy Young Participants: Protocol for a prospective, single-Arm, Exploratory, Clinical Study

  • Shin, Jae-Young;Ku, Boncho;Kim, Tae-Hun;Bae, Jang Han;Jun, Min-Ho;Lee, Jun-Hwan;Kim, Jaeuk U.
    • Journal of Pharmacopuncture
    • /
    • v.19 no.3
    • /
    • pp.197-206
    • /
    • 2016
  • Introduction: This study aims to investigate the effects of acupuncture stimulation on the radial artery's pressure pulse wave, along with various hemodynamic parameters, and to explore the possible underlying mechanism of pulse diagnosis in healthy participants in their twenties. Methods and analysis: This study is a prospective, single-arm, exploratory clinical study. A total of 25 healthy participants, without regard to gender, in their twenties will be recruited by physicians. Written informed consent will be obtained from all participants. The participants will receive acupuncture once at ST36 on both sides. The radial arterial pulse waves will be measured on the left arm of the subjects by using an applicable pulse tonometric device (KIOM-PAS). On the right arm (appearing twice), electrocardiogram (ECG), photoplethysmogram (PPG), respiration and cardiac output (CO) signals, will be measured using a physiological data acquisition system (Biopac module), while the velocity of blood flow, and the diameter and the depth of the blood vessel will be measured using an ultrasonogram machine on the right arm (appearing twice). All measurements will be conducted before, during, and after acupuncture. The primary outcome will be the spectral energy at high frequencies above 10 Hz ($SE_{10-30Hz}$) calculated from the KIOM-PAS device signal. Secondary outcomes will be various variables obtained from the KIOM-PAS device, ECG, PPG, impedance cardiography modules, and an ultrasonogram machine. Discussion: The results of this trial will provide information regarding the physiological and the hemodynamic mechanisms underlying acupuncture stimulation and clinical evidence for the influence of acupuncture on the pressure pulse wave in the radial artery. Ethics and dissemination: This study was approved by the Institutional Review Board (IRB) of Kyung Hee University's Oriental Medical Center, Seoul, Korea (KOMCIRB-150818-HR-030). The study findings will be published in peer-reviewed journals and presented at national and international conferences. Trial registration number: This trial was registered with the Clinical Research Information Service (CRIS) at the Korea National Institute of Health (NIH), Republic of Korea (KCT0001663), which is a registry in the World Health Organization's (WHO's) Registry Network.

The Effect of Pain Relieving Intervention During Infiltration among Gamma Knife Surgery Patients for Stereotactic Frame Fixation (감마나이프 수술 환자의 정위적 틀 고정을 위한 침윤 마취 시 통증 완화 중재의 효과)

  • Jang, Young Jun;Kim, Hyeon Ok
    • Journal of Korean Academy of Nursing
    • /
    • v.48 no.2
    • /
    • pp.221-231
    • /
    • 2018
  • Purpose: This study aimed to compare the effects of three interventions on pain, blood pressure, and pulse rate during infiltration anesthesia in patients about to undergo gamma knife surgeries. Methods: The three interventions employed in a university-affiliated Hospital in J City, South Korea were as follows: EMLA cream plus Vapocoolant spray (Vapocoolant, n=30), EMLA cream plus 10.0% Lidocaine spray (Lidocaine, n=30), and EMLA cream only (EMLA, n=30). The equivalent control-group pre test - post test study design was used. Pain was assessed subjectively using the numeric rating scale (NRS) and objectively using a Galvanic Skin Response (GSR) tester. NRS scores were assessed after infiltration anesthesia and the GSR was assessed during infiltration anesthesia. Blood pressure and pulse rate were assessed twice: before and after infiltration anesthesia. Data were collected between August 3, 2016 and March 24, 2017. Results: NRS scores after infiltration anesthesia and the GSR during infiltration anesthesia were significantly lower in the Vapocoolant group than in the Lidocaine and EMLA groups (F=13.56, p<.001 and F=14.43, p<.001, respectively). The increase in systolic blood pressure (F=4.77, p=.011) and in pulse rates (F=4.78, p=.011) before and after infiltration anesthesia were significantly smaller in the Vapocoolant group than in the Lidocaine and EMLA groups; however, no significant differences were observed in diastolic blood pressures (F=1.51, p=.227). Conclusion: EMLA cream plus Vapocoolant spray was the most effective intervention to relieve pain and to lower increase in systolic blood pressure and pulse rate caused by infiltration anesthesia for stereotactic frame fixation. Thus, application of Vapocoolant spray in addition to EMLA cream is highly recommended as a nursing intervention for patients undergoing gamma knife surgeries.

A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit (지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.1
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF

Body Systemic Circulation Assessment Method through Analysing the Radial, Dorsalis Pedis, Temporal Arterial Pulse Wave (3부위 최적맥파의 주파(h1) 비율 분석을 통한 전체 체순환 평가방법)

  • Yu, Seung-Yeon;Park, Eun-Sung;Choi, Ye-Bin;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.33 no.3
    • /
    • pp.121-130
    • /
    • 2016
  • Objectives : Recently, people who have normal brachial blood pressure(BP) are being threatened by high-risk disease such as stroke. The aim of this study is to suggest that new method to assess systemic circulation. It can be performed by analyzing optimal blood pulse wave on 3 sites belonging to subjects that have normal BP. Methods : We respectively extracted main peaks(h1) of optimal blood pulse wave on left/right temporal artery(LR1=h1), radial artery(LR2=h1) and dorsalis pedis artery(LR3=h1). We obtained h1 from 30 subjects who are discreetly chosen and have normal BP. Main peak(h1) can be extracted by using 3D pulse imaging analyser(DMP-1000+, DAEYOMEDI Co., Korea) that has 5-level pressure method. We analyzed the ratio of [LR1/LR2] and [LR3/LR2]. Results : In the case of male group, the results are [LR1/LR2=0.7100.177] and [LR3/LR2=0.9290.317]. In the case of female group, the results are [LR1/LR2=0.6680.121] and [LR3/LR2=0.7050.195]. Especially, it is statistically verified that the result of ratio [LR3/LR2] is much higher in male group than in female group(p<0.05). Conclusions : We suggested the standard ratio of [LR1/LR2] and [LR3/LR2] for normal subjects, respectively. It can be adopted as a new method to evaluate the systemic circulation.

Effects of Aerobic Exercise on Middle-aged Male Smokers' Blood Vessel Health (유산소 운동이 중년흡연남성의 혈관건강에 미치는 영향)

  • Kim, Jong-In;Jeong, Hae-Cheon;Won, Jun-Yeon;Ka, Sung-Soon;Oh, Bok-Sil
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.349-356
    • /
    • 2014
  • This research is aimed to prove if harmful effects of smoking, as the main reason for recently elevated blood vessel disease, could be reduced by aerobic exercise, and identify the positive effects of the aerobic exercise on smokers' blood vessel health(blood pressure, pulse pressure, and blood vessel elasticity. Experiments were performed on 40 male smokers aged between 40 and 55, which was equally divided into two groups of Aerobic Exercise Group (AEG) and Non Exercise Group (NEG). After measuring each group's blood pressure, pulse pressure, and blood vessel elasticity, AEG practiced aerobic exercise program for 50 minutes for each trial, three times a week, sustaining 12 weeks while NEG continued daily-life patterns without any special treatment. In 12 weeks, blood pressure, pulse pressure, and blood vessel elasticity of both groups were measured as the same way. As a result, the difference of systolic blood pressure between the two groups was not significant, while that of diastolic blood pressure was meaningful. The difference of pulse pressure between the two groups was meaningful, and that of blood vessel elasticity was also meaningful in all measuring points including left hand, right hand, left foot and right foot. As a consequent, it was found that aerobic exercise had positive effects on middle aged male smokers' blood vessel health.

Implementation and evaluation of the sensor assessing pressure and photoplethysmogram (압력맥파 및 광전용적맥파 검출용 일체형 센서의 구현 및 평가)

  • Kim, Gi-Ryon;Kim, Gwang-Nyeon;Choi, Byeong-Cheol;Jeon, Gye-Rok;Ham, Ki-Young;Suh, Duk-Joon;Jung, Dong-Keun
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.106-111
    • /
    • 2006
  • Pulse sensors generally have characteristics that cause a analytical error by the interference of signals according to tiny motion of body and pressure applied to skin. To resolve this problem, we implemented the sensor that is capable of simultaneously measuring pressure and PPG(photoplethymogram) in a state attached to skin. Pressure and PPG was recorded at the finger and wrist respectively to evaluate the usefulness of the implemented sensor. Then, it was observed that the shape of PPG from sensor changed by pressure pushing down skin. Results of this study suggested that it is possible to monitor a degree of skin pressurization and to guarantee a reliable measurement by simultaneously measuring pressure and PPG using implemented integrated sensor when measuring PPG on the wrist or the finger.

Study on the Radial Pulse Wave Variables and Heart Rate Variability after Acupuncture Stimulation (침자극이 좌관맥상과 심박수 미세변화에 미치는 영향)

  • Won, Jae-Kyun;Jung, Soon-Kwan;Kim, Dong-Eun;Lim, Jin-Young;Kwon, Young-Dal;Yeom, Seung-Ryong;Lee, Su-Kyung;Song, Yung-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.237-244
    • /
    • 2009
  • We investigated the effects of acupuncture stimulation on pulse wave variables and heart rate variability (HRV) in healthy adults. To evaluate twenty healthy volunteers (10 men, 10 women) had acupuncture into both Hapkok (Ll4) and Taechung (Liv3) for 15 minutes. Radial pulse, Heart Rate Variability, body temperature and blood pressure were checked before and after acupuncture to evaluate Pulse Wave Variability and Autonomous Function. The results were as follows; Heart rate was significantly increased while systolic blood pressure (mmHg) and diastolic blood pressure (mmHg) were significantly increased after acupuncture treatment. Sixteen subjects didn't change representative pulse wave variables after acupuncture treatment. Energy, height of main peak (H1), height of pre-dicrotic valley (H2) and height of descending valley (H4) were decreased while height of dicrotic peak (H5) was significantly decreased after acupuncture treatment. Time to main peak (T1), time to pre-dicrotic valley (T2), time to dicrotic peak (T5), total time (T) and T-T4 were decreased while time to descending valley (T4) was increased after acupuncture treatment. Total area (At), area of main peak (Aw) and ratio of diastolic period area (Ad) were decreased while ratio of systolic period area (As) and angle of main peak (MPA) were increased after acupuncture treatment. The standard deviation of all normal RR intervals (SDNN) was increased while the root mean square of successive differences between the normal heart beats (RMSSD) was significantly increased after acupuncture treatment by time domain analysis. Low frequency power (LF) and LF/HF ratio were decreased while high frequency power (HF) was significantly increased after acupuncture treatment by frequency domain analysis. This study suggests that acupuncture treatment changes pulse wave variability and heart rate variability. Further study on various acupuncture treatment for pulse wave variability and heart rate variability is required.